HomeMy WebLinkAbout117 Pawkannawkut Dr Air Leakage Report (2)180 State Rd Suite 2U, Sagamore Beach, MA 02562 • 508-833-3100 • energycodehelp.com • info@energycodehelp.com www.gocanvas.com 6FF5C52F-2253-432A-85EA-DFD75C3B9615 Duct Leakage Report 117 pawkannawkut dr. Yarmouth 11/11/2020 2015 IECC Energy Code Test Mode Pressurization Test Pressure 25.0 Pascals Testing Equipment Minneapolis Total CFM@25 0.00 Total Square Footage 2450.00 Maximum Allowable Leakage 98.00 or Total Duct Leakage Percentage 0.00 System Exemption Section R403.3.3 Exception - Duct Air Leakag test is not required where ducts and air handlers are entirely within the Building Thermal Envelope. HVAC Duct Test 180 State Rd Suite 2U, Sagamore Beach, MA 02562 • 508-833-3100 • energycodehelp.com • info@energycodehelp.com www.gocanvas.com 6FF5C52F-2253-432A-85EA-DFD75C3B9615 Location Sqft Served Ring CFM@25 Gauge Duct Leakage % 1 conditioned space 1600 C 0 0.00 2 conditioned space 850 C 0 0.00 180 State Rd Suite 2U, Sagamore Beach, MA 02562 • 508-833-3100 • energycodehelp.com • info@energycodehelp.com www.gocanvas.com 6FF5C52F-2253-432A-85EA-DFD75C3B9615 All testing results recorded in this report have been verified by: Chris Mazzola RTIN# - 8873503 ICC - 8344213 All testing was conducted in compliance with RESNET standards and protocols, the 780 CMR 51 Massachusetts Base Code, Stretch Code requirements and ASHRAE 62.2. In low infiltration homes, ventilation systems are vital to indoor air quality. Each newly constructed home must meet the 2013 ASHRAE 62.2 minimum ventilation specifications. Ventilation testing completed measures and ensures a healthy natural air exchange in the home. The fans installed in this home do not meet ASHRAE specifications and would require a programmable timer control to operate the fan independent of the on/off switch. Relative humidity levels in the home can have negative effects of the indoor quality. Testing contained in this report only verifies Fan Flow Rate, it is the Licensed CSL's Responsibility to ensure the required systems are installed.