HomeMy WebLinkAbout19-0716.1- 742 Route 28, S. Yarmouth - compressedASBESTOS INSPECTION
742 Route 28
South Yarmouth MA 02664
Prepared for:
Pirates Cove Adventure Golf
728 Main Street
South Yarmouth, MA 02664
August 24, 2019
Attn.: Derrick Rodrique
Prepared by:
SOUTH SHORE ENVIRONMENTAL SERVICES, LLC
________________
Richard Charpentier. Director
South Shore Environmental Services, LLC
P.O. Box 9130, Fall River, MA 02720 . Phone: 508 567-5298. Cell: 508 558-2138
Project Address: 742 Route 28South Yarmouth, MA 02664
Inspection Date (s): August 16 2019
Inspected By: Richard Charpentier, MA Certification No.: AI 900210
Job Number: 19-0716.2
Report Date: August 24, 2019
Report Requested by: Derrick RodriquesPhone:508 280-6428
Email: DerrickRoderiques@gmail.com
PURPOSE
The enclosed evaluation is to thoroughly inspect the property where demolition or renovationoperations will occur for the presence of asbestos, including Category I and Category II nonfriable ACM in accordance with the EPA National Emission Standards for Hazardous Air Pollutants
(NESHAP) Standard for Demolition and Renovation as described in 40 CFR Part 61.145 (a).
INSPECTION PROFILE
The property is an active Amusement Center where a market building (shown on cover page) is
proposed for demolition. The building is set on a concrete pad and the exterior is covered with various troweled stucco, cedar shingles and wood planking. The main roof is an EPDM and the lower roofs are asphalt shingled. The interior walls and ceilings contain sheetrock with joint compound and /or plaster skim coat. Ceilings are also sheetrock finished with joint compound and/ or suspended ceiling tiles.
No thermal system insulation (TSI) was detected throughout the building.
SAMPLING METHOD
Samples of suspect asbestos containing material (ACBM) were collected in accordance with the EPA NESHAP Standard for Demolition and Renovation as described in 40 CFR Part 61.145, labeled, placed in leak-tight containers and recorded on a ‘Chain of Custody’ (See AppendixA).The Chain of Custody includes the date collected, the location where the sample was taken andthe color of the material. The samples were delivered to EMSL Analytical, Inc., in Woburn, MA,
for analysis and logged in with the date and time the samples were relinquished by the inspector and received by the laboratory technician.
The MassDEP has issued a directive to all certified Asbestos Inspectors to follow the strict sampling methodology as set forth below that requires the collection of multiple samples of each homogeneous grouping of suspect asbestos containing material (SACM) as follows:
Friable Surfacing Material (SM) – 3 samples <1000ft2 - 5 samples 1000ft2 to 5000ft2- 7 samples
>5000ft2.
Thermal System Insulation (TSI) – 3 samples from each homogeneous area – Sufficient #for each mechanical system for fittings, tees, etc.
Miscellaneous Material (MM) - Sufficient # to determine if ACM or non-ACM for each homogeneous area – minimum 2 samples.
TESTING PROCEDURE
All samples were analyzed by Polarized Light Microscopy (PLM) Bulk Asbestos Analysis in
accordance with ERA 600/M4-82-020 per CFR 763 (NVLAP # 102079-0).
SAMPLING RESULTS
Sampling results are described in two categories: “Friable Asbestos Containing Material” and “Category I and Category II Non-friable Asbestos Containing Material” that is determined to
contain equal to or greater than 1% asbestos.
Samples are identified by the following asbestos types: (1) Thermal System Insulation (TSI) whichincludes any and all material used for heat/cold control, i.e. pipe insulation, boiler or tank insulation,breech insulation, etc.; (2) Surfacing Material (SFM) which includes any and all sprayed-on or
troweled-on material. i.e., spray-on insulation, textured paint, stucco, joint compounds, mastics,
etc.; (3) Miscellaneous Material (MM) which includes vinyl floor tiles, vinyl sheet goods, ductwrap insulation, wallboard, cementitious materials including transite panels, roofing, etc.
Sample results are reported by sample number, location, sample description, sample color, type of
asbestos and % of asbestos content of the homogeneous material represented by the sample.
Twenty-eight (28) samples were collected and twenty-eight (28) samples were analyzed by Asbestos Analytical Laboratory in Woburn, MA.
SUMMARY OF ASBESTOS CONTAINING MATERIAL (ACM)
NO ASBESTOS DETECTED
(SEE TABLES on next pages)
A licensed and trained asbestos inspector has made an effort to characterize visible and readily accessible suspect ACBM within the interior/exterior areas of the subject property building using
destructive methods. However, no survey can be all encompassing. As such, should construction
workers encounter and/or need to disturb product(s) suspected as being ACM, that have not been previously identified or sampled, during any renovation activities in the future, all proper precautions should be taken to ensure these materials are appropriately characterized and handled accordingly.
Table 1
Suspect Homogeneous Asbestos Containing Material Collected
Sample # Sample Description Color Sample Location FootageAmount SF/L
0716.1 - B1 Sheetrock -1 Gray 0716.1 - B1
0716.1 - B2 Associated Joint Compound -1 White 0716.1 - B2
0716.1 - B3 Sheetrock -2 Gray 0716.1 - B3
0716.1 - B4 Associated Joint Compound -2 White 0716.1 - B4
0716.1 - B5 Sheetrock Gray
0716.1 - B6 Associated Joint Compound White
0716.1 - B7 Sheetrock -1 Gray
0716.1 - B8 Associated Joint Compound -1
White
0716.1 - B9 Sheetrock -2 Gray
0716.1 - B10 Associated Joint Compound -2 White
Rear Storage Room, Ceiling
Rear Kitchen Storage Room, Ceiling
0716.1 - B11 Plaster Gray Rear Storage Room, Wall Behind Plastic Wall Panels
0716.1 - B12 Sheetrock Gray
0716.1 - B13 Plaster Skim Coat White Main Sales Area, Wall
0716.1 - B14 Associated Joint Compound White
0716.1 - B15 Unfinished Sheetrock Grey Main Sales Area, Left Side Nook, Above Wood Panel Ceiling Tiles
0716.1 - B16 Adhesive Tan Main Sales Area, Left Side Nook, Behind Wood Panel Ceiling Tiles
0716.1 - B17 2'x4' Suspended Ceiling Tile Gray Main Sales Area
0716.1 - B18 Sheetrock Gray Side Sales Area by Rest Rooms, Ceiling
0716.1 - B19 Stucco -1
0716.1 - B20 Stucco -2
0716.1 - B21 Roofing -1
0716.1 - B22 Roofing -2
0716.1 - B23 Roofing -1
0716.1 - B24 Roofing -2
0716.1 - B25 Asphalt Shingle -1
0716.1 - B26 Associated Tar Paper -1
0716.1 - B27 Asphalt Shingle -2
0716.1 - B28 Associated Tar Paper -2
Gray Exterior - Siding
Brown/Black EPDM Flat Roof - Field
Brown/Black EPDM Flat Roof -
Perimeter
Brown/Black Lower Shed Roofs
Highlighted samples indicate asbestos containing material (ACM)
Table 2
Friable Asbestos Containing Material Collected
Sample #Sample Description Color Sample Location Type % Asbestos
NONE DETECTED
Table 3
Non-Friable Asbestos Containing Material Collected
Sample #Sample Description Color Sample Location Type % Asbestos
NONE DETECTED
PHOTOS
APPENDIX A
LABORATORY
ANALYSIS
APPENDIX B
CHAIN OF CUSTODY