Loading...
HomeMy WebLinkAbout4872 12 Town Brook Rd Site Plan 11.23.20PEF SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE 25.0' MINIMUM .75' OF COVER OVER PRFCACT ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 25.0' NOTE: 2" MIN. WALL PRECAST H-10 RISERS (TYP.) THICKNESS REQUIRED BLOCKS OR 2'0 4"0SCH40 PVC PRECAST RISERS MORTAR ALL �,. :.: :..,, 6" MIN. SUMP PIPES LEVEL 1ST 2' 12" MIN. INT. DIM. COMPONENTS H-10 (NP•) EL 4'- �SIDES ENDS 10" 1500 GAL H-10 14" ➢o�o��. ° ° ° ° .. � , .. . ° ° ° 21.84' TEE SEPTIC TANK TEE �o�a o®aa MF= Joao >00000000 1.59' O O O O O O • O O O O O O WATERTEHT D'BOX °�°�°�°� . O°° O oo�oa�ao�o� a0000amm r im >°°°°O°O° °O°O°°°O GAS BAFFLE::: 000000000000 �_o�o�o�o,o_ FOR LEVELNESS O >°°°°°°°O N �j �j I�I�IJ IJ OI�I�I�I�I�I� MMMMI�I�I MMF-7M >oo°o°o°o '°O°°°°°° �0���0000�0 ;00000000 4' LIQ. LEVEL (ACME OR EQUAL) 21.47' 21.30' °°°°°°°° ° ' °°�°°°'° 22.03' 19.20' �000000�00000000000000 000oOonoo(o,000,000�000000° LH-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. ALL AROU (2) UNITS REQUIRED ( 2.5 % SLOPE) FOUNDATION 14' LEGEND- - 99 — EXISTING CONTOUR x 99• ' EXIST. SPOT ELEV. —[991-- PROPOSED CONTOUR 198•41 PROPOSED SPOT EL. TH 1 TEST HOLE SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: RON CADILLAC WITNESS: AMY VON HONE, RS DATE: 8/23/2011 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 4 ELEV 1 0" 26' a ND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [21) ( 1 % SLOPE) SEPTIC TANK 12' (1 % SLOPE) 12' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ZONING SUMMARY ZONING DISTRICT: R-25 DISTRICT MIN. TEST HOLE LOGS ENGINEER: RON CADILLAC WITNESS: AMY VON HONE, RS DATE: 8/23/2011 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 4 ELEV 1 0" 26' a ND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [21) ( 1 % SLOPE) SEPTIC TANK 12' (1 % SLOPE) 12' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ZONING SUMMARY ZONING DISTRICT: R-25 DISTRICT MIN. LOT SIZE 25,000 S.F MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. BUILDING COVERAGE 25% MAX. BUILDING HEIGHT 35' 4 ELEV. oil z 25.5' NO GROUNDWATER ENCOUNTERED DCE #20-30 Scale: 1 "= 20' 0 10 20 30 40 50 FEET LEACHING FACILITY N Lri 14.0' BOTTOM TH-2 NO GROUNDWATER FOUND DATE NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS PROPOSED 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. a O O T � BokPRoute 28 Locus 0 Q �m /eu o d oy .m 0 LOCUS MAP SCALE 1 "=2000'f ASSESSORS MAP 37 PARCEL 90 SITE IS NOT LOCATED WITHIN A ZONE II SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 2 BEDROOMS 0 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ' ALL AROUND , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #12 TOWN BROOK ROAD WEST YARMOUTH, MA PREPARED FOR 'r\ OF Ahy�s9 DANIELA. yes (\ No 46502 S T ER���w C_�? J DANIEL A. OJALA, P.E., P.L.S. KEN TOMASIAN DATE: NOVEMBER 23, 2020 off 508-362-4541 I fax 508-362-9880 downcope.com down cope engineering, knit. civil engineers land surveyors 939 Main Street ( R to 6A) YARMOUTHPORT MA 02675 20-301