HomeMy WebLinkAboutZELCH-9of9HIGH RAFTER TIES;
1 " x 8" RAFTER TIE
TIGHT TO UNDERSIDE
OF RIDGE
OR SIMPSON LSTA18 STRAP
TIE OVER RIDGE - EACH
RAFTER SET
SHORT GABLE RAFTERS;
2" x 10" KD SPF
® 16" O.C.
RIM JOIST; CONT.
1.75" x 11.875"
BCI VERSA -LAM LVLs
RUN THE FULL FACE
OF THE 2ND. FLOOR
BOX ONLY
PITCH
15 : 12
ASPHALT SHINGLES/
5/8" PLYWOOD
SHEATHING
CEILING JOISTS;
2" x 8" KID SPF
16" O.C.
3/4" T & G ADVANTECH
SUB FLOOR (N & G)
PITCH
4 : 12
2" x 6" x 7'-9" KID SPF
16" O.C. PROVIDE
SINGLE SHOE AND DOUBLE
TOP PLATES.
HEADERS IN -WALL TO
BE 2/ 2" x 10"
W/ I" CDX FLITCH PLATES
@ HEIGHTS SPECIFIED
SECOND FL. JOISTS;
11 J" TJI FLOOR JOISTS
12" O.C.
SEE FOUNDATION PLAN
24'-2"
ALL CONSTRUCTION TO BE PERFORMED IN STRICT
COMPLIANCE WITH THE MASSACHUSETTS STATE BUILDING
CODE, NINTH EDITION AND WOOD FRAME CONSTRUCTION
MANUAL FOR ONE- AND TWO-FAMILY DWELLINGS
FOR EXPOSURE C WIND LOADS - 110 MPH
ARC Designs , LLC ANY STRUCTURAL ENGINEERING REVIEW, IF NECESSARY,
ALAN R. CABRAL IS AT THE DISCRETION OF THE BUILDING COMMISSIONER
508.737.8281 AND WILL BE THE RESPONSIBILITY OF THE OWNER
INSULATION:
6" FIBERGLASS INSUL. =
R20 (WALLS)
9" FIBERGLASS INSUL. =
R30 (FLOORS)
COMBINATION OF
7 4" CLOSED CELL SPRAY
FOAM INSUL.
& 14" FIBERGLASS INSUL.
= R51 (CEILING)
CONTINUOUS RIDGE
BOARD; 1.75" x
11.875" LVL
(NON -BEARING)
PROVIDE SOLID BLOCKING AT
PANEL EDGES PERPENDICULAR
TO FRAMING MEMBERS IN THE
FIRST TWO JOIST BAYS
4'-0" O.0 (FLOORS & ROOF)
SHORT GABLE RAFTERS;
2" x 10" KID SPF
® 16" O.C.
1 /2" PLYWOOD
-
EXT. SHEATHING Cn
"ol
(RUN CONTINUOUS
TO ENGAGE TOP PLATE J
°'
TO TOP PLATE) j
PROVIDE SOLID BLOCKING z
O
FOR FULL PERIMETER
PLYWOOD NAILING
z
g
O
ADD (3) 2" x 4" ~
TOP PLATES TO w
EXISTING STUD WALL =
C)
z
w
J
-i
I
0
EXISTING STUD
WALL -
FRAMING
J SECTION "N"
( 1/4" = 1' )
* VERIFY ALL DETAILS WITH BUILDER
ADJUST AS REQUIRED
2" x 10" PT SPF
DECK JOISTS
® 16" O.C."
x 6" AZEK
DECKING
SOLID
f BLOCKING
MID -SPAN
OPENING HEADERS
& TRIMMERS;
2/ 2" x 10" PT SYP
S1
14'-0" (JOIST SPAN)
Roof Deck
Scale: 1/4"=1'
AREA = 196 ± SF.
42" HAND RAIL
- 4" x 4" PT SYP POSTS
- POST CAPS
- J" x 6" TOP RAIL
2" x 4" TOP & BOTTOM
RAIL
1 J" x 1 J" "CAPTURED"
BALLUSTERS @ 5" O.C.
4" x 4" PT SYP THRU-DECK POSTS
(3 EACH SIDE). LET THRU DECKING
TIGHT TO LVL RIDGE AND VALLEY
BEAMS ATTACHED W/ PAIRS OF
SIMPSON LSTA18 STRAP TIES
FLUSH DOUBLE PT BOX JOISTS.
THRU POSTS W/ PAIRS OF a"
GALV. CARRIAGE BOLTS (TO
INCLUDE DEPTH OF BACK
BLOCKING)
— DOUBLE HANGERS;
SIMPSON LUS28-2 ZMAX
OR GALVANIZED
PP,,, � � I M I N A P-, Y
PROPOSED RENOVATION AND ADDITIONS
slim No . .
51 PARK AVENUE
J ESSICA ZELCH
—FRAMING SECTION "M"
—ROOF DECK FRAMING PLAN
OCTOBER , 2020
WEST YARMOUTH
9 OF 9