Loading...
HomeMy WebLinkAboutsite plan 3-3-21LEGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 MIN. SIDE SETBACK TEST HOLE 2YY%' SLOPE OF GROUND 20' UTILITY POLE BUILDING COVERAGE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM DCE #20-174 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A- 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (73.8) (.74) = 109 GPD BOTTOM 315 (.74) = 233 GPD TOTAL: 462 S.F. 342 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH STONE AROUND (SEE DETAIL) APPROVED FIRST FLOOR EL. 19.4' PRECAST H-20 RISERS (TYP.) 2'0 15.16' SYSTEM PROFILEALL MARKED WITHCOMPONENTS MAGNETIC T EOR BE (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. H-20 CAST IRON COVERS TO GRADE 2" PEASTONE OR GEOTEXTILE H-20 CAST IRON COVER TO GRADE FILTER FABRIC OVER STONE n18-OO'INIMUM .75' OF COVER OVER PRECAST 2X SLOPE REQUIRED OVER SYSTEM 18.0' BLOCKS OR PRECAST RISERS 4"OSCH40 PVC MORTAR ALL INVERT IN 14.5' PIPES LEVEL 1ST 2' 4' COMPONENTS ENDS SDES U 10" 1500 GAL H-20 14" TEE SEPTIC TANK TEE °°°°°°°° ®®®®0 ®®®® ® 14.91 ®®®®®®®®®®® ® ° ° ° ° 0 0 6" MIN. SUMP GAS BAFFLE;: °s°°°o°°°° o' o. ®®®®®®®®®®® ®®®®®®® 0 0 0„0 0_ 12" MIN. INT. DIM. 00000°°° ®®®®®®®�®®® ®®®®®®®®®® o„a. o N> o 0 o°o 0 0 0 0 4' LIQ. LEVEL (ACME OR EQUAL) 14.77' } 14.6' °�__"__"__�•o _ ° (-A--% SLOPE) " •• WATERTEST D'BOX FOR LEVELNESS i00000000000000e0000000o MIN. 2' WALL THICKNESS ioo0oo0�0�0„0„0„0000000. I 3/4"-1-1/2" DOUBLE WASHED STONE APPROX. H-20 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUAL (2) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL AP RIOX.ALL DIMENSOONS TOECAST OUTSIDER OFTURES STONE: 25.00' X 12.83' (SEE DETAIL) COMPACTION. (15.221 (21) LO (-Lx X SLOPE) (-J-X SLOPE) H-20 FOUNDATION- 21 SEPTIC TANK 14' D' BOX 12' LEACHING 7.5' BOTTOM TH-1 FACILITYNO GROUNDWATER FOUND *THE INSTALLER SHALL VERIFY THE MA LOCATIONS OF ALL UTILITIES AND ALL DATE BOARD OF HEALTH BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM 25.0' LO Cn r A `' 22.0' LEACHING DETAIL 1 "=10' 00 CV r NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -2Q 5. PIPE JOINTS TO BE MADE WAlER11GHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) ' 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO . BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. TEST HOLE LOGS ENGINEER:DANIEL E. GONSALVES, SE #13587 WITNESS: MALLORY LANGLER DATE: 2/3/2021 PERC. RATE _ < 2 MIN/INCH CLASS 12" I SOILS 4 ELEV. 18.0' FI LL B LS 2099 1OYR 4/6 16.3' C PERC MS 2.5Y 6/3 126" 7.5' NO GROUNDWATER ENCOUNTERED A�NOFMgss OFn�gZ ���v icy~ DA IEL �����, � DRNIELA. 11 No. 40'980, o. 46502 �G- ESS\O s \nr �G/STE' z�����a (gNQSURI �N`ONAL DATE DANIEL A. OJALA, P.E., P.L.S. TITLE LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 49 PARCEL 217 LOCUS IS WITHIN FEMA FLOOD ZONE AE EL. 11 AS SHOWN ON COMMUNITY PANEL #25001 CO587J DATED 7/16/2014 ZONING SUMMARY ZONING DISTRICT: R-25 RESIDENTIAL DISTRICT MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 0 � MIN. _ �0 30' MIN. SIDE SETBACK 15' MIN. a 20' MAX. BUILDING COVERAGE L ocu ornin (. ga LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 49 PARCEL 217 LOCUS IS WITHIN FEMA FLOOD ZONE AE EL. 11 AS SHOWN ON COMMUNITY PANEL #25001 CO587J DATED 7/16/2014 ZONING SUMMARY ZONING DISTRICT: R-25 RESIDENTIAL DISTRICT MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. BUILDING COVERAGE 25% PROP. BUILDING COVERAGE 13.2% OF 756 SWAN LAKE ROAD WEST YARMOUTH, MA PREPARED FOR JOHN CIFELI DATE: MARCH 3, 2021 Scale:1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 I fax 508-362-9880 downcape.com down cope engineering, I VA ci vil engineers land surveyors 939 Main Street ( Rte 6A) YARMOU THPOR T MA 02675 19-174 CIFELLI.DWG