Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
21-A032
APPROVED Y R U0'H I I R N CLERK,. QYArt yo TOWN OF YARMOUTH �� MAR 22 2021 2 z 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451 '2114P-7.25 ,13:99 RFC YARMOUTH Telephone(508)398-2231 Ext. 1292-Fax(508)398-0836 OLD KING'S p,' IL,; i G'S HIGHWAY HISTORIC DISTRICT COMMITTEE APPLICATION FOR CERTIFICATE OF APPROPRIATENESS Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as amended, for proposed work as described below&on plans,drawings, photographs, &other supplemental info accompanying this application. PLEASE SUBMIT 4 COpieS OF SPEC SHEET(S), ELEVATIONS, PHOTOS,&SUPPLEMENTAL INFORMATION. Check All Categories That Appl : Indicate type of Building: Commercial XI Residential 1) Exterior Buildin Construction: 'New Building FI Addition Iterations Reroof _Garage Shed Solar Panels I Other: 2) Exterior Painting: _ Siding I Shutters Doors , Trim I 'Other: 3)Signs/Billboards: New Sign Change to Existing Sign 4) Miscellaneous Structures: Lifence Wall IIFlagpole Pool Other: Please type or print legibly: Address of proposed work: 35 Avon Rd Yarmouth MA 02675 Map/Lot# 143-12 Owner(s): Vincent Guardia Phone#:508-737-9388 All applications must be submitted by owner or accompanied by letter from owner approving submittal of application. Mailing address: 35 Avon Rd Yarmouth MA 02675 Year built: 1982 Email: vinceguardia@gmail.com Preferred notification method: IX Phone LI Email Agent/contractor: Sunrun Installation Services Phone#: 978-793-7881 Mailing Address: 734 Forest ST STE 400 Marlborough MA 01752 (� �( Email: mapermlts@Sunrun.COm Preferred notification method: I I Phone I� Email Description of Proposed Work: Installation of an interconnected rooftop PV system. Black on black panels on front and rear of home 33 (Longi 315W HPB) Panels 10.395 KW DC Signed(Owner or agent): Date: 02/04/2021 Owner/contractor/agent is aware that a permit is require rom the Building Department. (Check other departments,also.) If application is approved,approval is subject to a 10-day appeal period required by the Act. This certificate is good for one year from approval date or upon date of expiration of Building Permit,whichever date shall be later. All new construction will be subject to inspection by OKH.OKH-approved plans MUST be available on-site for framing&final inspections. For Committee use only: © Approved Approved with Modifications Denied Applicant shall seek OKH approval for any changes Rcvd Date: Reason for Denial: - Amount to these plans prior to the change being incorporated into the project. Cash/CK#: Rcvd by: signed Approved by: 45 Days: Richard Gegenwarth Robert Wilkins Rosemary Nicholls Date Signed: Paula Morrison APPLICATION#: GENERAL SPECIFICATION SHEET Project Address: ____________________ FOUNDATION: Material: ______________________________________ Exposure (Not to exceed 18”): _____________ CHIMNEY: Material/Color: ___________________________GUTTERS: Material/Color:___________________________ ROOF: Material: ___________________Pitch (7/12 min)___________Height to Ridge:__________ Color: ____________ SIDING: Material/Style: Front: _____________________ Sides/Rear: ____________________ COLOR CHIPS Color: Front: ___________________________ Sides/Rear: ___________________ TRIM: All windows & doors to be trimmed with: 1x 4 1x5 (Circle one.) Material: ________________________________ Color: _____________________ DOORS: Qty: _______ Material: ____________________ Color: _____________________ Style/Size (if not listed/shown on elevations): ________________________________________ STORM DOORS: Qty: _____ Material: __________________ Color: _____________________ GARAGE DOORS: Qty: ____ Mat’l: _______________ Style: ___________ Color: __________ WINDOWS: Qty/side:: Front: ______ Left: ______ Right: ______ Rear: _____ Color: ___________ Manufacturer/Series: __________________________________ Material: ________________________ Grilles (Required): Pattern (6/6, 2/1, etc.) __________ Grille Type: True Divided Lite: _________ Snap-In: __________ Between Glass: _____ Permanently Applied: ____Exterior ____Interior STORM WINDOWS: Qty: _________ Material: ______________________ Color: __________ SHUTTERS: Mat’l: ______________Style: Paneled______ Louvered ______ Color: _________ SKYLIGHTS: Qty:________ Fixed_____ Vented ______ Size _________ Color: _________ DECK: Size:____________ Decking Mat’l:__________________________ Color: __________ Railing Mat’l:__________________ Style: ___________________ Color: __________ WALLS/FENCES* (Max 6’ height): Height: _______________ Mat’l: __________________________ St yle: ___________________________ Color: ________________________________ (Show running footage & location on plot plan.) *Finished side of fence must face out from fenced in area. UTILITY METERS/HVAC UNITS: Location: ____________________ Screening: ___________ LIGHTS: Qty: ___________ Style: ___________________________ Color: _______________ Location(s): __________________________________________________________ LIGHT POSTS: Qty: ___________ Material: ___________________________ Color: _______________ Location(s): __________________________________________________________ Additional information: _______________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ 2-General APPLICATION #: ________________ Solar Panels- Black on black - roof mounted. TOWN OF YARMOUTH 1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451 Telephone (508) 398-2231 Ext. 1292 Fax (508) 398-0836 OLD KING’S HIGHWAY HISTORIC DISTRICT COMMITTEE WAIVER OF 45-DAY DETERMINATION The applicant/applicant’s agent understands and agrees that due to the current declared National and State public health emergencies the determination of our Application for a Certificate of Appropriateness/Demolition/Exemption may not be made within 45 days of the filing of such application. The applicant agrees to extend the time frame within which a determination is to be made as required by the Old King's Highway Regional Historic District Act. SECTION 9 -Meetings, Hearings, Time for Making Determinations “As soon as convenient after such public hearing; but in any event within forty-five (45) days after the filing of application, or within such further time as the applicant shall allow in writing, the Committee shall make a determination on the application.” Applicant understands that the review of this application will be scheduled as soon as the situation allows. Applicant/Agent Name (please print):______________________________________________ Applicant/Agent signature:_____________________________________Date:_____________ Application #: ___________________ 3/2020 Stephen A Kelly 02/04/2021 TOWN OF YARMOUTH OLD KING’S HIGHWAY HISTORIC DISTRICT COMMITTEE ABUTTERS’ LIST Applicant’s (Owner) Name: __________________________________________ Property Address/Location: __________________________________________ Hearing Date: ________________ Notices must be sent to the Applicant and abutters (including owners of land on any public or private street or way) who’s property directly abuts or is across the street from the Applicant. Please provide the Assessor’s Tax Map and Lot numbers only. The OKH Office will send out notices using the addresses as they appear on the most recent applicable tax list. Note: Instructions for obtaining the abutters Map and Lot numbers can be found on the Old King’s Highway Department page on the Town website: www.yarmouth.ma.us Map Number Lot Number Applicant Information: Abutter Information: Application #: _______________________ 3 8.2018 143 12 143 23 143 38 143 44 143 45 143 11 143 10 143 13 Sunrun Installation Services (Vincent Guardia) 35 Avon Rd Yarmouth MA 02675 OWNER’S AUTHORIZATION FORM For Permit Application(s) The sole purpose of this form is to provide Sunrun, Inc. with thenecessary permission from the Owner to file permit a pplication(s) for suchproject work as agreed upon between the Owner and the Owner’s Authorized Company and its designated subcontractors. Owner’s Name:_____________________________________________ Solar Project Address:________________________________________ Signature:__________________________________________________ Owner’s Authorized Company: Sunrun, Inc. Company’s Address: 595 Market St 29th Floor, San Francisco, CA 94105 Affiliation: Contractor Applicable License: State: MA \n1\ \s1\ DocuSign Envelope ID: 4799626A-4022-41FD-BCD3-80ACAD9159C8 Vincent Guardia 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 Avon Street Here Aerial View for rooftop Solar Black on black panels Page 1 ARB Rendering 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 Right side view from Avon St Left Side View from Avon St Page 2 ARB Rendering 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 Aerial View of home with two other homes in area with Solar on the front of the house Page 3 ARB Rendering 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 Above View from Oxford Rd to the side of the home to the left Above view of the home from Oxford Rd coming down the road with home to the righ View from corner of Oxford Rd and Avon Rd. Home is behnd the Trees Page 4 ARB Rendering COVER SHEET SCOPE OF WORK GENERAL NOTES REV NAME DATE COMMENTS A AC AFCI AZIM COMP DC (E) ESS EXT INT MAG MSP (N) NTS OC PRE-FAB PSF PV RSD TL TYP V W AMPERE ALTERNATING CURRENT ARC FAULT CIRCUIT INTERRUPTER AZIMUTH COMPOSITION DIRECT CURRENT EXISTING ENERGY STORAGE SYSTEM EXTERIOR INTERIOR MAGNETIC MAIN SERVICE PANEL NEW NOT TO SCALE ON CENTER PRE-FABRICATED POUNDS PER SQUARE FOOT PHOTOVOLTAIC RAPID SHUTDOWN DEVICE TRANSFORMERLESS TYPICAL VOLTS WATTS PAGE REV: A 2/1/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 (415) 580-6920 ex3 TABLE OF CONTENTS PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE PV-1.0 LEGEND AND ABBREVIATIONS SCALE: NTS MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) PV LOAD CENTER SUB-PANEL CB ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS SUNRUN METER METAL PIPE VENT DEDICATED PV METER SERVICE ENTRANCE IQ COMBINER BOX HARDSCAPE PROPERTY LINEINTERIOR EQUIPMENT SHOWN AS DASHED PL SNR MOUNT& SKIRT SNR MOUNT RAIL SOLAR MODULES STANDOFFS & FOOTINGS MP SP SM PM INV AC DC LC SE VICINITY MAP #SSTAMPCS #ESTAMPCS • ALL WORK SHALL COMPLY WITH MA 9th Ed. CMR 780 (2015 IRC/IBC/IEBC), MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.94 AMPS MODULE SHORT CIRCUIT CURRENT. • 15.53 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. • PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION • SYSTEM SIZE: 10395W DC, 7920W AC • MODULES: (33) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPB-315M • INVERTERS: (33) ENPHASE ENERGY: IQ7-60-2-US • RACKING: SNAPNRACK RLU; RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE DETAIL SNR-DC-00436 • RACKING: SNAPNRACK SERIES UR; ULTRA RAIL FLUSH STANDOFF, 8-1/2 IN. SEE UR40-PEN-D10. PL PL PL PL PL PL PL PL PL PL PL P L P L P L PAGE REV: A 2/1/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 (415) 580-6920 ex3 SITE PLAN ARRAY PITCH PV AREA (SQFT) AR-01 41°288.7 AR-02 10°306.7140° TRUE AZIM MAG AZIM 334°320° 154° PV-2.0 #SSTAMPSP #ESTAMPSP PM SITE PLAN - SCALE = 3/64" = 1'0" (N) ARRAY AR-01 (N) ARRAY AR-02 (E) RESIDENCE (E) DRIVEWAY SE MP CB AC AVON R D NOTE: MICRO-INVERTERS INSTALLED UNDER EACH MODULE PAGE REV: A 2/1/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 (415) 580-6920 ex3 PV-3.0 LAYOUT #SSTAMP DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 30 PSF WIND SPEED: 140 MPH 3-SEC GUST. STRUCTURAL NOTES: ·INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. ·IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ··ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% ··ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS S.S. LAG SCREWS: 5/16"X4.5": 2.5" MIN EMBEDMENT D1 - AR-01 - SCALE: 3/16" = 1'-0" PITCH: 41° AZIM: 320° D2 - AR-02 - SCALE: 3/16" = 1'-0" PITCH: 10° AZIM: 140° 1'-6"33'-5"1'-7" 1'-2" 9'-11" 6'-5" 1'-5"33'-5"1'-8" 5'-4"TYP 5'-4"TYP ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max Span OC Spacing Detail Max Landscape OC Spacing Max Landscape Overhang Max Portrait OC Spacing Max Portrait Overhang Configuration AR-01 COMP SHINGLE - RLU 2-Story 2X10 RAFTERS 17' - 0"16"RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE DETAIL SNR-DC-00436 5' - 4"2' - 1"4' - 0"2' - 0"STAGGERED AR-02 FLAT, ROLLED COMP [FLUSH MOUNT][1HB] - UR 2-Story 2X10 RAFTERS 13' - 5"16"ULTRA RAIL FLUSH STANDOFF, 8-1/2 IN. SEE UR40-PEN-D10.5' - 4"2' - 1"4' - 0"1' - 8"STAGGERED 3'-2" 9'-11" 9" M 240V METER SOCKET 100A CONTINUOUS (N) MA SMART UTILITY REVENUE METER UTILITY SIDE OF CIRCUIT CONNECTS TO TOP LUGS - (LINE AT TOP LOAD AT BOTTOM) FACILITY GROUND FACILITY LOADS EXISTING 200A MAIN BREAKER EXISTING 200A MAIN PANEL SUPPLY SIDE TAP (N) LOCKABLE BLADE TYPE FUSED AC DISCONNECT 50A FUSES SQUARE D D222NRB 3R, 60A 120/240VAC M METER #: EVERSOURCE 2363252 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID 4 33 JUNCTION BOX OR EQUIVALENT 12 20A BREAKER [A] 20A BREAKER [B] 20A BREAKER [C] (N) 125A ENPHASE IQ AC COMBINER BOX WITH INTEGRATED 10A ENVOY BREAKER 3CX-IQ-AM1-240-3C (1) BRANCH OF (11) MICRO-INVERTERS [B] (33) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPB-315M MODULES AND MICRO-INVERTER PAIRS (33) ENPHASE ENERGY: IQ7-60-2-US -- (1) BRANCH OF (11) MICRO-INVERTERS [A] (1) BRANCH OF (11) MICRO-INVERTERS [C] CONDUIT SCHEDULE #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG PER ENPHASE Q CABLE BRANCH NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV.(6) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 4 3/4" EMT OR EQUIV.(2) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 PAGE REV: A 2/1/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 (415) 580-6920 ex3 PV-4.0 ELECTRICAL #ESTAMP MODULE CHARACTERISTICS LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPB-315M: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 315 W 40.6 V 33.7 V 9.94 A PAGE REV: A 2/1/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 (415) 580-6920 ex3 SIGNAGE PV-5.0 #ESTAMP CAUTION: 35 AVON RD, YARMOUTH, MA, 02675 MULTIPLE SOURCES OF POWER PER CODE(S): NEC 2020: 690.56(B) +705.10 and NEC 2017: 705.10 + 710.10 SERVICE ENTRANCE PV PRODUCTION METER (EXT) COMBINER BOX MAIN PANEL(INT) SOLAR PANELS AND MICROINVERTERS ON ROOF MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 33.00 AMPS 240 VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, NEC 2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54 PV SYSTEM DISCONNECT WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2), NEC 2017: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(3), NEC 2014: 705.12(B)(3), NEC 2011: 705.12(D)(7) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), NEC 2017: 690.56(C)(1)(a) 4" 3" ELECTRICAL SHOCK HAZARD WARNING! TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): NEC 2020: 690.56(c)(2), NEC 2017: 690.56(C)(3), NEC 2014: 690.12, NEC 690.56, IFC 2012: 605.11.1, IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM AC DISCONNECT (EXT) DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, RL UNIVERSAL, SPEEDSEAL™ MOUNT KIT 242-92642 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, FOAM 623 UP, 674 DOWN, 505 SIDE N/A 12 LB-FT UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM UL SUBJECT 2582 1.39 PARTS LIST DESCRIPTIONQTYITEM SNAPNRACK, SPEEDSEAL TRACK, 7-1/2IN, SEALING, MILL11 SNAPNRACK, RL UNIVERSAL, MOUNT12 1 2 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, RL UNIVERSAL, SPEEDSEAL™ MOUNT KIT 242-92642 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: ALL DIMENSIONS IN INCHES 3.594.591.50 1.09 2.37 7.50 3.751.59 .33 2.39 .10.32 1.28 .10 3.10 UR-40 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS INSTALLED PENETRATION DETAIL EXPLODED DESCRIPTION:DRAWING NUMBER:SCALE:DESIGNER: APPROVED BY: REVISION: Sunrun South LLC 595 MARKET STREET, 29TH FLOOR Ɣ SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 Ɣ FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. ULTRA RAIL, ATTACHMENT DETAIL, 1-HOLE BASE WITH STANDOFF TO RAFTERSNR-DC-00348 1 5/7/2019 NEW DETAIL REV: 1DATE: DNS 5/7/2019 DRAFTER:M.AFFENTRANGER B.PETERSON G.MCPHEETERS Solar Mounting Solutions MJA BIN: 5 15 8 " 11 2 " 11 2 " 21 4 " STRUCTURAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. *FLASH POST WITH STANDARD GLAVANIZED STEEL ROOF FLASHINGS FOR 1" DIAMETER VENT PIPE 21 2 " MIN. EMBEDMENT INTO WOOD RAFTER SNAPNRACK SPRING FOR ULTRA RAIL 5 16 " LAG SCREW S.S. WITH FLAT WASHER S.S. (MIN. 21 2 " EMBEDMENT INTO WOOD RAFTER) 5 16 " SPLIT LOCK WASHER, S.S.SNAPNRACK ULTRA MOUNT, TAPPED SNAPNRACK ULTRA MOUNT, THRU SNAPNRACK STANDOFF BASE, 1-HOLE SNAPNRACK STANDOFF SHAFT, STANDARD (VARIOUS HEIGHTS) 5 16 " X 3" BOLT S.S. SNAPNRACK SPRING CAGE FOR ULTRA RAIL SNAPNRACK STANDOFF CLAMP SNAPNRACK RUBBER RAIN COLLAR (INSTALLS OVER FLASHING CONE)SNAPNRACK ULTRA RAIL SNAPNRACK ULTRA RAIL STANDARD STANDOFF ON 1-HOLE BASE FOR MOUNTING TO VARIOUS ROOF TYPES REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS DRAWING 5 16 " S.S. LAG SCREW MUST EMBED A MIN. OF 21 2 " INTO STRUCTURAL MEMBER REFER TO SNAPNRACK INSTALLATION MANUAL FOR 5 16 " HARDWARE TORQUE SPECIFICATIONS RAILS CAN MOUNT UPLSOPE OR DOWNSLOPE OF THE STANDOFF SHAFT FOR LEVELING DETAILS, REFER TO SNAPNRACK DETAIL DRAWING "SNR-DC-00334 ULTRA RAIL, COMPONENT DETAIL, LEVELING SPACER ON STANDOFF" *A POURED SEALANT-STYLE FLASHING MAY BE USED WITH SNAPNRACK STANDOFFS AS AN ALTERNATIVE TO CONE FLASHINGS WHEN INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS ON LOW-SLOPE ROOF SURFACES MODULE HEIGHT OFF ROOF, RANGE: UR-40: 71 2 " - 85 8 " UR-60: 81 8 " - 91 4 " (SHOWN FOR 7" STANDOFF SHAFT, ADJUST PER SHAFT LENGTH) 7" STANDOFF SHAFT SHOWN. LENGTH VARIES 355/366 COMPLETED INSTALLATION COMPLETED INSTALLATION SECTION VIEW DETAIL A A DESCRIPTION:DRAWING NUMBER:SCALE:DESIGNER: APPROVED BY: REVISION: Sunrun South LLC 595 MARKET STREET, 29TH FLOOR Ɣ SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 Ɣ FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. RL UNIVERSAL, ATTACHMENT DETAIL, SPEEDSEAL TRACK ON COMPSNR-DC-00436 1 11/11/2019 NEW DETAIL 2 7/7/2020 NU001109 REV: 2DATE: NTS 7/7/2020 DRAFTER:B.PETERSON W.ARBUCKLE D.RYAN Solar Mounting Solutions BDP DR SNAPNRACK RL UNIVERSAL SPEEDSEAL TRACK COMPOSITION ROOF MOUNTING EMBED P5 16 " LAG SCREW 2-1/2" INTO THE ROOF STRUCTURAL MEMBER / RAFTER FOR TORQUE SPECIFICATIONS SEE INSTALLATION MANUAL ROOF RAFTER (TYP.) ROOF ATTACHMENTS SHALL BE EMBEDDED INTO ROOF RAFTERS OR OTHER STRUCTURAL MEMBERS ROOF SHEATHING, UNDERLAYMENT, AND ROOFING MATERIAL (TYP.) ROOF DECKING ROOFING MATERIAL ROOFING MATERIAL 2-1/2" MIN. EMBEDMENT INTO RAFTER OR STRUCTURAL MEMBER RAFTER ROOF SHEATHING PILOT HOLE CENTER OF COURSE P 5 16" S.S. LAG SCREW 2-1 2" MINIMUM EMBEDMENT SPEEDSEAL TRACK WASHER SPEEDSEAL TRACK SHOULD BE INSTALLED PARALLEL TO RAFTER SPEEDSEAL TRACK FOAM DAM P 5 16" S.S. LAG SCREW WASHER ROOFING MATERIAL SPEEDSEAL TRACK 111111111111pllllllllllllllllllllll 01W01111W11101111W11101111 111111IIIIIIIIIIIIIIIIIIIIIIIIIIIIII 111111111111pllllllllllllllllllllll 01W 111111 W111.01111 W11101111 01W011110WI.011110W101111 01W011110WI011110WI01111 01W011110WI011110WI01111 01W011110WI011110WI01111 IIWIIIIIIIIWIIIIIIIIIWIIIIIIII 111111 iffi IIIIIIll111111111101111 011110WI011110WI01111,01W 011110WI011110WI01111,01W 011110WI011110WI011111W11 011110WI0111f,0W1011111W11 011110WI011110WI011111W11 011110WI0111f,0W1011111W11 011110WI011110WI0111101W 011110WI0111f0W10111f01W 011110WIIIIIIIIIWI0111[IIWI Complete System and Product Certifications IEC 61215,IEC61730,UL1703 ISO 9001:2008: ISO Quality Management System ISO 14001: 2004: ISO Environment Management System TS62941: Guideline for module design qualification and type approval OHSAS 18001: 2007 Occupational Health and Safety U�_V C@ C E * Specifications subject to technical changes and tests. LONGi Solar reserves the right of interpretation. ■ LONGI Positive power tolerance (0 —+5W) guaranteed High module conversion efficiency (up to 19.1 %) Slower power degradation enabled by Low LID Mono PERC technology: first year <2%, 0.55% year 2-25 Solid PID resistance ensured by solar cell process optimization and careful module BOM selection Reduced resistive loss with lower operating current Higher energy yield with lower operating temperature Reduced hot spot risk with optimized electrical design and lower operating current Room 801, Tower 3, Lujiazui Financial Plaza, No.826 Century Avenue, Pudong Shanghai, 200120, China Tel: +86-21-80162606 E-mail: module@longi-silicon.com Facebook: www.facebook.com/LONGi Solar Note: Due to continuous technical innovation, R&D and improvement, technical data above mentioned may be of modification accordingly. LONGi Solar have the sole right to make such modification at anytime without further notice; Demanding party shall request for the latest datasheet for such as contract need, and make it a consisting and binding part of lawful documentation duly signed by both parties. V10 LR6-60HPB 300~320M El i Junction Box: IP67, three diodes Tolerance: Length +2mm Output Cable: 4mm2, 300mm in length LR6-60HPB 300~320M Operational Temperature: -40 C -+85 C Power Output Tolerance: 0 - +5 W Voc and Isc Tolerance: ±3% Maximum System Voltage: DC1000V (IEC/UL) Maximum Series Fuse Rating: 20A Nominal Operating Cell Temperature: 45±2 C Safety Class: Class II Fire Rating: ULtype 1 ortype 2 Model Number Cell Orientation: 120 (6x20) Unts:min(incn) Junction Box: IP67, three diodes Tolerance: Length +2mm Output Cable: 4mm2, 300mm in length Worm: ±2mm length can be customized Height ±imm STC Pitch-'h-mw:±tmm Glass: Single glass NOCT 3.2mmcoatedtempered glass NOCT Frame: Anodized aluminum alloyframe A Weight:18.9kg 300 Dimension: 1683x996x35mm ^� Packaging: 30pcs per pallet 310 180pcs per 20'GP 315 780pcs per40'HC Operational Temperature: -40 C -+85 C Power Output Tolerance: 0 - +5 W Voc and Isc Tolerance: ±3% Maximum System Voltage: DC1000V (IEC/UL) Maximum Series Fuse Rating: 20A Nominal Operating Cell Temperature: 45±2 C Safety Class: Class II Fire Rating: ULtype 1 ortype 2 Model Number LR6-60HPB-300M LR6-60HPB-305M LR6-60HPB-310M LR6-60HPB-315M LR6-60HPB-320M Testing Condition STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT Maximum Power (Pmax/W) 300 222.2 305 225.9 310 229.6 315 233.4 320 237.1 Open Circuit Voltage (Voc/V) 39.8 37.1 40.1 37.4 40.3 37.7 40.6 37.9 40.9 38.2 Short Circuit Current (Isc/A) 9.70 7.82 9.78 7.88 9.86 7.94 9.94 8.01 10.02 8.08 Voltage at Maximum Power (Vmp/V) 32.9 30.4 33.1 30.6 33.3 30.8 33.7 31.1 33.9 31.3 Current at Maximum Power (Imp/A) 9.13 7.32 9.21 j 7.38 9.30 7.46 9.36 j 7.50 9.43 7.56 Module Efficiency(%) 17.9 18.2 18.5 18.8 19.1 STC (Standard Testing Conditions): Irradiance 1000W/m2, Cell Temperature 251C, Spectra at AM1.5 NOCT (Nominal Operating Cell Temperature): Irradiance 800W/m2, Ambient Temperature 20 C, Spectra at AM1.5, Wind at 1m/S Temperature Coefficient of Isc Temperature Coefficient of Voc Temperature Coefficient of Pmax +0.057%/'C -0.286%/'C -0.370%/'C Current -Voltage Curve (LR6-60HPB-310M) 10 s 6 - Cell Temp=25-C - Cell Temp=35-C ` 4 - Cell Temp=45°C V - Cell Temp=55-C 2 - Cell Temp=65C Cell Temp=75°C 0 0 10 20 30 40 Voltage M LONGI Front Side Maximum Static Loading Rear Side Maximum Static Loading Hailstone Test Power -Voltage Curve (LR6-60HPB-310M) 350 Cell temp: 25°C ncident In,,1 1000W/m' 300 Incident ll incident Inad �ooW/m' 250 Incident Inad=400W/m' Incident brad. 200W/ 200 0 150 100 50 0 0 10 20 30 40 Voltage M 5400Pa 2400Pa 25mm Hailstone at the speed of 23m/s Current -Voltage Curve (LR6-60HPB-310M) 12 10 8 6 V 4 2 0 0 10 20 30 40 Voltage M Room 801, Tower 3, Lujiazui Financial Plaza, No.826 Century Avenue, Pudong Shanghai, 200120, China Tel: +86-21-80162606 E-mail: module@longi-silicon.com Facebook: www.facebook.com/LONGi Solar Note: Due to continuous technical innovation, R&D and improvement, technical data above mentioned may be of modification accordingly. LONGi Solar have the sole right to make such modification at anytime without further notice; Demanding party shall request for the latest datasheet for such as contract need, and make it a consisting and binding part of lawful documentation duly signed by both parties. V10 The Enphase IQ Combiner 3™ with Enphase IQ Envoy™ consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Enphase IQ Combiner 3 (X-IQ-AM1-240-3) To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring Simple • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • UL listed To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 3, and other trademarks or service names are the trademarks of Enphase Energy, Inc. 2019-11-04 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy™ printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and optional* consumption monitoring (+/- 2.5%). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile Connect™ CELLMODEM-03 (4G/12-year data plan) CELLMODEM-01 (3G/5-year data plan) CELLMODEM-M1 (4G based LTE-M/5-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Consumption Monitoring* CT CT-200-SPLIT Split core current transformers enable whole home consumption metering (+/- 2.5%). * Consumption monitoring is required for Enphase Storage Systems Wireless USB adapter COMMS-KIT-01 Installed at the IQ Envoy. For communications with Enphase Encharge™ storage and Enphase Enpower™ smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner™ and allows redundant wireless communication with Encharge and Enpower. Circuit Breakers BRK-10A-2-240 BRK-15A-2-240 BRK-20A-2P-240 Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating (output to grid)65 A Max. fuse/circuit rating (output)90 A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. continuous current rating (input from PV)64 A Max. total branch circuit breaker rating (input)80A of distributed generation / 90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions (WxHxD)49.5 x 37.5 x 16.8 cm (19.5” x 14.75” x 6.63”). Height is 21.06" (53.5 cm with mounting brackets). Weight 7.5 kg (16.5 lbs) Ambient temperature range -40º C to +46º C (-40º to 115º F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors• 60 A breaker branch input: 4 to 1/0 AWG copper conductors• Main lug combined output: 10 to 2/0 AWG copper conductors• Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE-M) (not included) COMPLIANCE Compliance, Combiner UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1 Enphase IQ Combiner 3 The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Microinverters Region: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell modules. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2019 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2019-3-26 INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings¹235 W - 350 W +235 W - 440 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc)15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range²240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable)0.85 leading ... 0.85 lagging 0.85 leading ... 0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6 %97.6 %97.5 %97.3 % CEC weighted efficiency 97.0 %97.0 %97.0 %97.0 % MECHANICAL DATA Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US)MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7 and IQ 7+ Microinverters COVER SHEET SCOPE OF WORK GENERAL NOTES REV NAME DATE COMMENTS A AC AFCI AZIM COMP DC (E) ESS EXT INT MAG MSP (N) NTS OC PRE-FAB PSF PV RSD TL TYP V W AMPERE ALTERNATING CURRENT ARC FAULT CIRCUIT INTERRUPTER AZIMUTH COMPOSITION DIRECT CURRENT EXISTING ENERGY STORAGE SYSTEM EXTERIOR INTERIOR MAGNETIC MAIN SERVICE PANEL NEW NOT TO SCALE ON CENTER PRE-FABRICATED POUNDS PER SQUARE FOOT PHOTOVOLTAIC RAPID SHUTDOWN DEVICE TRANSFORMERLESS TYPICAL VOLTS WATTS PAGE REV: A1 3/13/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 (415) 580-6920 ex3 TABLE OF CONTENTS PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE PV-1.0 LEGEND AND ABBREVIATIONS SCALE: NTS MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) PV LOAD CENTER SUB-PANEL CB ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS SUNRUN METER METAL PIPE VENT DEDICATED PV METER SERVICE ENTRANCE IQ COMBINER BOX HARDSCAPE PROPERTY LINEINTERIOR EQUIPMENT SHOWN AS DASHED PL RAIL STANDOFFS & FOOTINGS SOLAR MODULES SE MP SP LC SM PM INV AC DC VICINITY MAP #SSTAMPCS #ESTAMPCS • ALL WORK SHALL COMPLY WITH MA 9th Ed. CMR 780 (2015 IRC/IBC/IEBC), MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.94 AMPS MODULE SHORT CIRCUIT CURRENT. • 15.53 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. • PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION • SYSTEM SIZE: 6300W DC, 4800W AC • MODULES: (20) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPB-315M • INVERTERS: (20) ENPHASE ENERGY: IQ7-60-2-US • RACKING: SNAPNRACK SERIES UR40; ULTRA RAIL FLUSH STANDOFF, 8-1/2 IN. SEE UR40-PEN-D10. PL PL PL PL PL PL PL PL PL PL PL P L P L P L PAGE REV: A1 3/13/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 (415) 580-6920 ex3 SITE PLAN ARRAY PITCH PV AREA (SQFT) AR-01 10°360.8 TRUE AZIM MAG AZIM 154°140° PV-2.0 #SSTAMPSP #ESTAMPSP PM SITE PLAN - SCALE = 3/64" = 1'0" (N) ARRAY AR-01 (E) RESIDENCE (E) DRIVEWAY SE MP CB AC AVON R D NOTE: MICRO-INVERTERS INSTALLED UNDER EACH MODULENOTE: MICRO-INVERTERS INSTALLED UNDER EACH MODULE PAGE REV: A1 3/13/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 (415) 580-6920 ex3 PV-3.0 LAYOUT #SSTAMP DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 30 PSF WIND SPEED: 140 MPH 3-SEC GUST. STRUCTURAL NOTES: ·INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. ·IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ··ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% ··ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS S.S. LAG SCREWS: 5/16"X4.5": 2.5" MIN EMBEDMENT D1 - AR-01 - SCALE: 1/4" = 1'-0" PITCH: 10° AZIM: 140° ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max Span OC Spacing Detail Max Landscape OC Spacing Max Landscape Overhang Max Portrait OC Spacing Max Portrait Overhang Configuration AR-01 FLAT, BUILT-UP [FLUSH MOUNT][1HB] - UR 2-Story 2X10 RAFTERS 13' - 5"16"ULTRA RAIL FLUSH STANDOFF, 8-1/2 IN. SEE UR40-PEN-D10.5' - 4"2' - 1"4' - 0"1' - 8"STAGGERED 1'-4"33'-5"1'-9" 7" 12'-3" 1'-1" 6'-2"9'-5" 4'TYP M 240V METER SOCKET 100A CONTINUOUS (N) MA SMART UTILITY REVENUE METER UTILITY SIDE OF CIRCUIT CONNECTS TO TOP LUGS - (LINE AT TOP LOAD AT BOTTOM) FACILITY GROUND FACILITY LOADS EXISTING 200A MAIN BREAKER EXISTING 200A MAIN PANEL SUPPLY SIDE TAP (N) LOCKABLE BLADE TYPE FUSED AC DISCONNECT 25A FUSES SQUARE D D222NRB 3R, 60A 120/240VAC M METER #: EVERSOURCE 2363252 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID 4 33 JUNCTION BOX OR EQUIVALENT 12 20A BREAKER [A] 20A BREAKER [B] (N) 125A ENPHASE IQ AC COMBINER BOX WITH INTEGRATED 10A ENVOY BREAKER 3CX-IQ-AM1-240-3C (1) BRANCH OF (10) MICRO-INVERTERS [B] (20) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPB-315M MODULES AND MICRO-INVERTER PAIRS (20) ENPHASE ENERGY: IQ7-60-2-US -- (1) BRANCH OF (10) MICRO-INVERTERS [A] CONDUIT SCHEDULE #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG PER ENPHASE Q CABLE BRANCH NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV.(4) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 4 3/4" EMT OR EQUIV.(2) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 PAGE REV: A1 3/13/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 (415) 580-6920 ex3 PV-4.0 ELECTRICAL #ESTAMP MODULE CHARACTERISTICS LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPB-315M: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 315 W 40.6 V 33.7 V 9.94 A PAGE REV: A1 3/13/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 (415) 580-6920 ex3 SIGNAGE PV-5.0 #ESTAMP CAUTION: 35 AVON RD, YARMOUTH, MA, 02675 MULTIPLE SOURCES OF POWER PER CODE(S): NEC 2020: 690.56(B) +705.10 and NEC 2017: 705.10 + 710.10 SERVICE ENTRANCE PV PRODUCTION METER (EXT) COMBINER BOX MAIN PANEL(INT) SOLAR PANELS AND MICROINVERTERS ON ROOF MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 20.00 AMPS 240 VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, NEC 2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54 PV SYSTEM DISCONNECT WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2), NEC 2017: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(3), NEC 2014: 705.12(B)(3), NEC 2011: 705.12(D)(7) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), NEC 2017: 690.56(C)(1)(a) 4" 3" ELECTRICAL SHOCK HAZARD WARNING! TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): NEC 2020: 690.56(c)(2), NEC 2017: 690.56(C)(3), NEC 2014: 690.12, NEC 690.56, IFC 2012: 605.11.1, IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM AC DISCONNECT (EXT) 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 Aerial View. Panels strictly to rear of home. REVISED ARB RENDERING Page 1 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 Right View from Avon Rd. Panels Rear of home not visible Left View From Avon Rd Panels Rear of home not visible REVISED ARB RENDERING Page 2 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 VINCENT GUARDIA 35 AVON RD, YARMOUTH, MA, 02675 PROJECT NUMBER: 221R-035GUAR CUSTOMER RESIDENCE: TEL. (508) 737-9388 APN #: YARM-000143-000012 #180120 View From Oxford Rd heading to Avon Rd Panels will not be visible from street REVISED ARB RENDERING Page 3