HomeMy WebLinkAbout21-A047 J`""`} TOWN OF YARMOUTH
f 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451 (�
Telephone(508)398-2231 Ext. 1292-Fax(508)398-0836 EC EQ�.l l5
OLD KING'S HIGHWAY HISTORIC DISTRICT C s gi EE D
i
APPLICATION FOR
CERTIFICATE OF APPROPRIATENESS COMMUNITY
I DEVELOPMENT
Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as
amended,for proposed work as described below&on plans,drawings, photographs.&other supplemental info accompanying this
application. PLEASE SUBMIT 4 copies OF SPEC SHEET(S),ELEVATIONS,PHOTOS,&SUPPLEMENTAL INFORMATION.
Check All Categories That Appl : Indicate type of Building: Commercial ✓ Residential
1) Exterior Buildin Construction: New Building t .Addition Alterations Reroof l l Garage
Shed ✓ Solar Panels I Other:
(� r t€ ri aHriiw F,'
2) Exterior Painting: Siding Shutters l l Doors Trim Other:
3)Signs/Billboards: ri New Sign Change to Existing Sign '21APR1 1PH2:49 RFC
4)Miscellaneous Structures: Fence IWall E,Flagpole nPool IIOther:
Please type or print legibly:
Address of proposed work: 31 Hawk's Wing Rd Yarmouth MA 02664 Map/Lot# I 09 / 5_5
Owner(s): Tsvetomir Hristov Phone#:774-408-6015
All applications must be submitted by owner or accompanied by letter from owner approving submittal of pplication.
Mailing address: 31 Hawk's Wing Rd Year built: iiii0 I
Email: rich@the400east.com Preferred notification method: [7 Phone 12 Email
Agent/contractor: Summit Energy Group - Raphaela Cobbett Phone#: 339-201-7769
Mailing Address: 293 Libbey Industrial Pkwy STE 250, Weymouth MA 02189
Email: raphaela.c@summit.solar Preferred notification method: 12 Phone a Email
Description of Proposed Work:
Installation of a 11.55 kW solar system.
Total of 35 solar panels located on the southwest facing roof section.
Signed(Owner or agent): /r Date: 03/012j_
Owner/contractor/agent is aware that a permit is required from the Building Department.(Check other departments,also.)
If application is approved,approval is subject to a 10-day appeal period required by the Act.
This certificate is good for one year from approval date or upon date of expiration of Building Permit,whichever date shall be later.
All new construction will be subject to inspection by OKH.OKH-approved plans MUST be available on-site for framing&final inspections.
For Committee use only: E Approved Approved with Modifications Denied
Applicant shall seek OKH approval for any changes
Rcvd Date: ,-•/L-4..- -4 Reason for Denial:
Amo„ ` ,r '' —to-these plans prior to the change
Cash/CK#: 'Tieing incorporated into the project.
Rcvd by: 1, i Signed.
APPROVED BY: APPRO 1
45 Days: Richard G-• -
Robert Wi .•• ► .r 21
Date Signed: Paula Morrison
YA(
Rosemary Nicholls •LD KING'S HIGHWAY1
t
APPLICATION#: LI- !\OLR
GENERAL SPECIFICATION SHEET
FOUNDATION: Material:Exposure (Not to exceed 18'):
CHIMNEY: Material/Color:
ROOF: Material:
GUTTERS: Material/Color:
SIDING : l\ilaterial/Style: Front:
Color: Fronl:
DOORS: Qty: _ Material:
Style/Size (if not listed/shown on elevations):
STORM DOORS: Qty: _ Material:
GARAGE DOORS: Qty: _ Mat'l:
WINDOWS: QryEilg: Front:
Manufacturer/Series:
Pitch (7112 min)_Height to Ridge:
Sides/Rear:
Sides/Rear:
'l x 4 1x5 (Circle one.)
Color:
Color:
Style:
Right:Color:
Material:
COLOR CHIPS
TRIM: All windows & doors to be trimmed with:
Material:
Color:
SHUTTERS: MatI:
SKYLIGHTS: Qty:_ Fixed
Grilles (Reouired): Pattern (6/6.2/1- etc.) Grille TvDe: True Divided Lite: fl
Snap-ln: l-l
-BLtween
ctass:ffeer;]fr1-ngy npptied: l--l Exterio-{--ltntertor
STORM WINDOWS: Qty: _ Material:
DECK: Size:Decking Mat'l:
Railing [/at'l:Style:
WALLS/FENCES' (Max 6' height);Height:Mat'l:
Style:
(Show running footage & location on plot plan.) .Finished side of fence must face oul from fenced in area.
UTILITY METERS/HVAC UNITS: Location:Screening:
Color:LIGHTS: Qty:Style:
Location(s):
LIGHT POSTS: Qty:Material:
Location(s):
Additional information:
Style: Paneled Louvered
Size
Color:
Color:
Color:
Color:
Color:
2-General
APPLICATION #:
oLDKTNG''H*Hli;ry|ro,5rY#881"'f*"tcoMMtrrEE
Applicant's (Owner) Name:
ABUTTERS'LIST
Tsvetomir Hrijor/
I
Property Address/Location: 54 Ho,hlK s iltnq R"L '
Hearing Date: q l4Z
Notices must be sent to the Applicant and abutters (including owners of land on any
public or private street or way) who's property directly abuts or is across the street from
the Applicant. Please provide the Assessor's Tax Map and Lot numbers onlv. The
OKH Office will send out notices using the addresses as they appear on the most recent
applicable tax list.
Note: lnstructions for obtaining the abutters Map and Lot numbers can be found on the Old King's
Highway Department page on the Town website: www.varmouth.ma.us
Map Number Lot Number
Applicant I nformation :LC*n b"5
Abutter lnformation:Io1 5r,
1fr 5,t\
Lffi 5"w
LO1 5.LL
1ffi 5.f
1-08 7b
L08 ?-9
8.2018
Application #:Ll-AD.{t
TOWN OF YARMOUTH
I146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451
Telephone (508) 398-223 I Ext. 1292 Fax (508) 398-0836
OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE
WAIVER OF 45-DAY DETERMINATION
The applicant/applicant's agent understands and agrees that due to the current declared
National and State public health emergencies the determination of our Application for a
Certificate of Appropriateness/Demolition/Exemption may not be made within 45 days of the
filing of such application.
The applicant agrees to extend the time frame within which a determination is to be made as
required by the Old King's Highway Regional Historic District Act.
SECTION 9 -Meetings, Hearings, Timefor Making Determinations
"As soon as convenient after such public hearing; but in an)) event within forty''-five (45) days
after the .filing of application, or within such further time as the applicant shall allow in
writing, the Committee shall make a determination on the application."
Applicant understands that the review of this application will be scheduled as soon as the
situation allows.
Applicant/Agent Name (please CrLb"lt
Applicant/Agent signature :
312020
Application #' , I -AOq U
Prop€rty Location 31 HAWKS WING RO
Vision lD 103725 Account # 103725
Map lD 109/ 5.5/ / /Bldg Name
Sec# 'l of 1 Card #of
State Use 1010
Ptinl9ale 10123n020Bldg #
CURRENr OWNER TOPO UTILITIES :TRT / ROAD LOCATION CURRE'VIASSESSMEIVT
815
YARMOUTH, MA
HRISTOV TSVETOMIR B
NAUMOVA HRISTOV V G
PO BOX 205
WEST HARWICH MA 02671
Levei 2 Public Water Paved 2 Suburban Description Code Assesseo Assessed
6 Septic RESIONTL
RES LAND
'1010
'1010
410,300
'121.900
410,300
121,9004Gas
SUPP DATA
Att Prcl lD
MISC 350
CHANGES
BETTERMENTS
PLAN # 4811,481
ztP coDE 9999:
Gts lD M_308505_E278s9
VOTE
VOTE DATE
PRIVATE
Assoc Pid#
VISION
To(afl 532.i
RECORD )F OWNERSHIP BX.VOUP SALE DATE tu v/t SALE PRICE vc PREY'OUS ASSESSMEN T S ( H'S IO R Y)
HRISTOV TSVETOI\4IR B
DAVCO BUILDERS LLC
GREAT WESTERN ROAD LLC
GREAT WESTERN ROAD LLC
29719
28936
19053
19052
0160
0305
0028
0337
06-10-2016
0ea12-2015
09-21-20cA
09-21-20cA
o
U
U
U
I
I
400,000
60,000
100
50,000
UN
1B
1J
,tG
Year Year Year
2021 1010
1010
410,300
121,900
2020 1010
1010
365,600
121,900
2019 11010 I 312.100
lroro I 12r,9oo
Total 532200 Totall 487500 Tolall
EXEMPTIONS OIHER ASSESSMEIVIS This signaturs acknowl€dges a Msit by a Data Collsclor or Assessor
Ei-f6ffi I DacriPtim Description Number Cornm lnt
Appraised Bldq. Value (Card)
Appraised Xf (B) Value (Bldg)
Appraised Ob (B) Value (Bldg)
Appraised Land Value (Bldg)
Special Land Value
Total Appraised Parcel Value
Valuation Method
407,800
2.500
0
121,900
0
532,200
c
Total
assEssrlrG NEIGHBORHOOD
Nbhd Nbhd Name B Tracing Baich
0040
,VOIES
YELLOWNATUML I/G AG
SV2O16: NEWCONS WORK COMPLETE
CTH CEILS
Total Appraised Parcel Value 532,200
BUILDING PERMIT RECORI VISIT / CHANGE HISTORY
Permit ld lssue Date Type Description lnsp Daie o/o Coi^,o Date Comp Comments Date Tvpe ls PurposUResult
14-944 o1-13-2014 NC New Construct 372,500 01-30-2016 100 NC.3 BEDROOI'S, 2 BATHS,10-2+2019
08-032016
01-30-2016
0!03-2015
0141-2014
08-01-2005
Kt\,,1
BH
RF
LS
BH
JB
02
02
01 1
CL
SV
BP
BP
CY
00
Cyclical
Sales Veriflcaton
Building Permit
Building Permit
CYCLICAL 2014
Meas ur+Listed
L .,NE VALUA ToMECrrorl
B Use Code Oescription Zore Land Type Land Unils Unit Price Size Adj Site lndex Cmd.Nbhd.Nbhd. Adj Notes Location Adjr/stment Adj Unit P
1010 SINGLE FAM M 16,988 SF 1.00000 4 1.00 0040 1.000 FYOT SUBDIV#43 1.0000 7.17 121,900
Tolal Card Land Units 16,988 SF Tota Land Area 0.3900 Total Land 121,
1 7.17
Property Location 3't HAWKS WING RD
Vision lD 103725 Account #
Map lD 1091 5.51 I I Bldg Name
Sec# 1 of 1
State Use 1010
Print Date 1012312020103725Bldg #Card #
CONSTRUCTION DETAIL CONSIRUGT'ON D ETAI L (CO N f I N U ED )
Element Cd I Description Element Cd Description
FOP
32
Style:
Model
Grade:
Stories:
Occupancy
Exterior Wall 1
Exterio Wall 2
Roof Structure:
Rmf Cover
lnteriorWall 1
lnterior Wall 2
Itnt"dor Flr. 1
llnterior Flr 2
lneat Fuel
I H""t ryr.,
lRc rype:
lTotal Bedroorns
lTotrl Bthrr",
lTot t H"rf Baths
lTot"l xtr" Firtr.
lTot"l R*'nr,
ls"tt sty",
lxitchen StYe:
I
I
I
I
I
I
I
I
Ranch
Residential
Average +20
Wood Shingle
Gable/Hip
Asph/F Gls/Cmp
DrywdUSheet
Hardwood
Gas
Forced Air-Duc
Central
3 Bedrooms
01
05
1
1
14
03
03
05
103
lo+
lo,
103
t;
l.
loz
loz
Average
Modern
DATA
Parcel lcl cl uwne lo.u
IB
Adtust Iype I god Descriotion I Fac
conclo Flr
Condo Unit
COST / MARKET VALUATION
Building Value New
Year Built
Effective Year Built
Depreciation Code
Remodel Rating
Year Remodeled
Depreciation %
Functimal Obsd
Ext. Cornment
Trend Factor
Condition
Condition %
Percent Gmd
RCNLD
Dep 7o Ow
Dep Ow Cornment
Misc lmp Ow
Misc lmp Ow Comment
Cost to Cure Ow
Cmt fo Crrre Ow Comment
407
201,
A
,762
4
0
0
0
1
100
407,800
UAT
FGR
BAS
UBM
13
17
17
11 FOP
6
't3
1
OB . OUTBUILDING & YARD I I EM5IL)
Description Unit Price Yr Blt c Grade Adl.Appr. vatue
HTL HEATILATOR B 1 2500.00 2015 100 0.00 2,50C
BUTEDTM' SUB.AREA SUMMARY SECTION
Code Description Livrnq Area Floor Area Eff Area Unit Cost Undeprec Value
BAS
CTH
FGR
FOP
UAT
UBM
First Floor
Cathedral Clng
Garage
Porch, Open, Finished
Attic, Unfinished
Basement, Unfinished
1,675
0
0
0
0
0
1,O/5
't,675
483
382
483
1,675
1,675
0
'193
76
48
335
172.63
0.00
68.98
34.35
17.16
34.53
2U9,1 5t'
0
33,318
13,120
8,286
57,831
Rl Gross Liv / Lease Area 1,6751 6,371 2,321 401,7
E , tIrl
Nffiru,u*"
.+i]j- --r1:-,:
;. F .,. {"t
1-P;:--..1:'i
. ,rls..'.': i
;,$'1i i. . ':}1
t
I
HWllii$m
(
,:'',1 t:i l''
Aurora Shade Report
customer
Rich Hristov
Address
3'l Hawk's Wing Rd
Yarmouth
MA 02664
3
il
tl
G
q
I
t,
,"a lf '
?.'
t It
.r.}
Summary
ArraY
Designer
Siddharth Temburni
Coordinates
(4.1 693545, -70 19651'l)
Organization
Summit Energy Group
Date
10 February202l
Panel Count Azimuth (deg.)Pitch (deq.)Annual TOF (%)
kWh/m2lyear
2,450 or more
Annual Solar Access (7.)Annual TSRF (%)
2,100
1,750
I ,.,,
l:"
Annual irradiance
I
2
Weighted average
by panel count
Monthly solar access (%) across arrays
Array Jan Feb Mar APr
o2
87
25
10
J/
21
90
89
89.9
75
77
75.6
May sepAug
e2 90 90 88 84
89 89 88 83 80
88 89 92 92 92
84 89 90 90 92
91
91
aq
81
WTYi1t3
I
262
26?
Customer
Rich Hristov
Address
31 Hawk's Wing Rd
Yarmouth
MA02664
Designer
Siddharth Temburni
Coordinates
(41 693545, -70.19651 1)
Organization
Summit Energy Group
Date
1 0 February 2021
Zoomed out satellite view 3D model
3D model with LIDAR overlaY
r(2i3
19ft
7t,t
Customer
Rich Hristov
Address
31 Hawk's Wing Rd
Yarmouth
MA 02664
II
l, Siddharth Temburni, certify that I have generated this shading report to the best of my abilities, and I
believe its contents to be accurate.
Designer
Siddhafth Temburni
Coordinates
(41 693545, -70.1 9651 1)
Organization
Summit Energy GrouP
Date
10 February 202']
E I
I
t
?,.xcxEt
Street view and corresponding 3D model
3/3
31 HawlCs Wing Rd
Gooqle
F.
F+:
P".
F?'
E. t'
al
a
lf
F'
DIRECTORY
iT SUMMARY
AN-
;ITE PLAN
PV5 IATTACHMENTOIAGRAM
PV6 ,TTACHMENT DETAILS & ELEVATION
3ELS
NEW PV SYSTEM: TSVETOMIR HRISTOV
31 HAWK'S WING RD, YARMOUTH, MA 02664, USA
PV SYSTEM RATING (DC): 11.55 Kw
(41 .693531, -70.1 96541 )
n\(:y
SUMMIT
ENERGY
SUMMIT ENERGY GROUP
293 LIBBEY INDUSTRIAL PKWY,
UNIT 250, WEYMOUTH,
MA 02't89, USA
888-578{648
I}53
t- qu s t
EE E$ s r
tr ? r=
=z;8
[-]
OESIGN ENGINEER
SIODHARTH TEMBURNI
NABCEP PVIP CERTIFIED
sto@suMMtT.soLAR
PROFESSIONAL ENGINEER
SCOTT WYSSLING
W CONSULTING
P.E. STRUCTUML, PP, CME
NH LICENSE NO. 15260
(o): (201) 874-3483
SYSTEM INFORMATION
DC SYSTEM SIZE 1 1.55 KW
AC SYSTEM SIZE 10 KW
DC/AC RATIO 1.15
MODULE
REC TWINPEAK BLACK SERIES,
330TP3M, 330W
MLPgINVERTER SOLAREDGE TECHNOLOGIES,
P340, SElOoooH-US
RACKING SNAP N RACK
ATTACHMENTS ULTRA RAIL COMPK KIT
rOTAL ARRAY ARE,A 630 SO. FT.
NO- OF MODULES 35
ARRAY 1 AZIMUTH 262'
ARRAY 1 PITCH 37'.
ARRAY 2 AZIMUTH 262'.
ARMY 2 PITCH 21',
ARMY 3 AZIMUTH
ARRAY 3 PITCH
ARRAY 4 AZIMUTH
ARRAY 4 PITCH
ARRAY 5 AZIMUTH
ARRAY 5 PITCH
AVERAGE TSRF
UTILITY NAME EVERSOURCE
REMOTE
MONITORING YES
STREET VIEW
THIS OOCUMENT HAS SEEN PREPARED FOR THE PUPOSE OF
OESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER
SYSTEM WTH ENOUGH OETAIL TO DEMONSTRATE COMPI.IANCE WITHMEffiIE COOES ND ffiGUUTIONS. THE MUMENT S&L NOT
SE RELIED UPON AS A SUSSNTUTE FOR FOLLOWING MANUFACTURER
INSTALUTION INSTRUCTIONS- CONTRACTOR SHALL INSTAL
EQUIPMENT Iil ACCORDANCE WTH MANUFACTURER INSTRUCTIONS
ANO NOflING IN THIS OOCUMENT SHIL AE INTERPRETEO IN AWAY
THAT OVERRIDES THEM. CONTMCTOR IS RESPONSIBLE FOR
OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN
DOCUMENT,
SITE DETAILS
ASHME EXTREME LOW 3.2"F (-16'c)
ASHRAE 2% HIGH 82.4"F (28'Cl
CLIMATE OATA
SOURCE MA, USA (WMO: 725067)
WINO SPEED
RISK CATEGORY I
W|ND EXPOSURE
CATEGORY
B
GROUNO SNOW LOAD 30 PSF
INTERCONNECTION DETAILS
POINT OF CONNECTION
NEW 5UTtsLY >IUE AU
CONNECTION PER NEC
ARTTCLE 705.12(A)
UTILIry SERVICE 12O|24OV 1l
ELECTRICAL PANEL 2OOA MAIN SREAKER, 2OOA
PANEUBUSS
BTM, LINE TAP/SUPPLY SIDE
SERVICE ENTRANCE UNDERGROUNO
APPLICABLE COOES & STANDARD
BUILDING
MASSAUHUSEI I S tsUILUINU
CODE, gTH EDITION, AS AMENDEO
0m cMRl
ELECTRICAL
MASSACHUSEI IS ELEUI XIUAL
cooE (527 CMR 12.00) NFPA 70E
(20'l7NEC)
FIRE AASSACHUSE I I 5 UUMPKENENSIVt
F|RE SAFETY COOE (527 CMR 1.00)
SCOPE OF WORK
THIS PROJECT INVOLVES THE INSTALUTION OF SOUR PANELS, THE
PANELS WLI SE RACKED USING A PRE- ENGINEERED
THE RACKEO MOOULES WILL BE ELECTRICILY CONNECTEO WTH DC
rO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL
UTILITY USING MEANS AND METHOOS CONSISTENT WTH THE RULES
ENFORCED BY THE LOCAL UTILITY ANO PERMITTING JURISDICTION-PV1
PROJECT SUMMARY
2.1.1 sm NorEs:
2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA
REGULATIONS.
2.1.3 THE PV MODULES ARE CONSIOEREO NON-COMEUSTIBLE ANO THIS SYSTEM IS A
UTILITY INTEMCTIVE SYSTEM WTH NO STOMGE BATTERIES.
2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR
BUILOING ROOF VENTS.
2.1.5 PROPER ACCESS AND WORKING CLEAMNCE AROUND EXISTING ANO PROPOSEO
ELECTRICAL EOUIPMENT WILL BE PROVIDED AS PER SECTION NEC 1 10.26.
2.,I.6 ROOF COVERINGS SHALL BE DESIGNEO, INSTALLEO, AND MAINTAINED IN
ACCORDANCE WITH THIS COOE AND THE APPROVED MANUFACTURER'S
INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE
BUILDING OR STRUCTURE,
2.2.'l EOU|PXETT LOCATIONS
2.2.2 ALL EOUIPMENT SHALL MEET MINIMUM SETBACKS AS REOUIREO BY NEC 1 I0.26.
2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED
OPEMTING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A).(C) AND NEC TABLES
310.15 (BX2XA) AND 310.1s (BX3XC).
2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNOER PV MOOULES
ACCOROTNG TO NEC 690.34.
2.2.4 AODTTTONAL AC OTSCONNECT(S) SHAIL BE PROVTDED WHERE THE INVERTER lS NOT
WITHIN SIGHT OF THE AC SERVICING DISCONNECT.
2.2.5 ALL EOUIPMENT SI-IAI.L BE INSTALLEO ACCESSIBLE TO OUALIFIEO PERSONNEL
ACCORDING TO NEC APPLICABLE CODES.
2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTOOOR
USAGE WHEN APPROPRIATE.
2.3.I STRUCTURAL XOTES:
2.3.2 MCKING SYSTEM & PV ARMY WILL BE INSTALLED ACCOROING TO
CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REOUIRE A
OESIGNATED SPACE BETWEEN MODULES, ANO RAILS MUST ALSO EXTEND A
MINIMUM OISTANCE BEYOND EITHER EDGE OF THE ARMY/SUBARRAY,
ACCORDING TO MIL MANUFACTURER'S INSTRUCTIONS.
2.3.3 JUNCTION 8OX WILL BE INSTAILED PER MANUFACTURERS' SPECIFICATIONS.
IF ROOF.PENETMTING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL
REOUIREMENTS.
2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WLL BE COMPLETED AND
SEALEO w/APPROVEO CHEMICAL SEALANT PER CODE BY A LICENSEO
CONTMCTOR.
2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE
SPAN OISTANCE SPECIFIEO BY THE RACKING MANUFACTURER.
2.3.6 WHEN POSSIALE, ALL PV RELATED MCKING ATTACHMENTS WLL BE
STAGGEREO AI.IONGST THE ROOF FRAMING MEMBERS.
2./a.l GROUT{DIIG IOTES:
2.,I.2 GROUNOING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, ANO
GROUNOING OEVISES EXPOSEO TO THE ELEMENTS SI.IAI-L BE RATED FOR SUCH
USE.
2.4.3 AS IN CONVENTIONAL PV SYSTEMS, UNGROUNDEO PV SYSTEMS REOUIRE AN
EOUIPMENT GROUNOING CONDUCTOR. ALL METAL ELECTRICAL EOUIPMENT AND
STRUCTURAL COMPONENTS BONOEO TO GROUNO, IN ACCOROANCE WTH 250.I34 OR
250.136(A). ONLY THE OC CONOUCTORS ARE UNGROUNOEO.
2.4.4 PV EQUIPMENT SHALL 8E GROUNOEO ACCORDING TO NEC 690.43 AND MINIMUM
NEC TABLE 250.I22.
2.4.5 METAL PARTS OF MOOULE FMMES, MOOULE RACKING, ANO ENCLOSURE
CONSIDERED GROUNoEo lN ACCORO WITH 250.13,r AND 25o.136(A).
2.,T.6 EACH MODULE WILL BE GROUNOEO USING WEEB GROUNDING CLIPS AS SHOWN IN
MANUFACTURER DOCUMENTATION ANO APPROVED BY THE AHJ. IF WEEBS ARE
NOT USED, MOOULE GROUNDING LUGS MUST AE INSTALLED AT THE SPECIFIEO
GROUNDING LUG I.IOLES PER THE MANUFACTURERS' INSTALLATION
REOUIREMENTS.
2.4.7 THE GROUNOING CONNECTION TO A MODULE SHALL BE ARRANGEO SUCH THAT
THE REMOVAL OF A MOOULE OOES NOT INTERRUPT A GROUNOING CONDUCTOR TO
ANOTHER MOOULE.
2.iT.8 GROUNOING ANO BONDING CONOUCTORS. IF INSULATEO, SHALL 8E COLOREO
GREEN OR MARKEO 6REEN IF #,I AWG OR LARGER INEC 250.119]
COLOREO OR ilARKEO A3 FOLLOW3:
OC POSITIVE. REO, OR OTHER COLOR EXCLUOING WHITE. GREY ANO
GREEN
OC NEGATIVE- BLACK, OR OTHER COLOR EXCLUOING WHITE, GREY
AND GREEN
2.7.8 AC CONOUCTORS COLORED OR MARKED AS FOLLOWS:
PHASE A OR L1- BLACK
PHASE B OR 12. REO. OR OTHER CONVENTION IF THREE PHASE
PHASE C OR L} BLUE, YELLOW OMNGE', OR OTHER CONVENTION
NEUTML. WHITE OR GREY. IN 4.WIRE DELTA CONNECTED SYSTEMS THE PHASE WTH I.IIGHER VOLTAGE
TO BE MARKED OMNGE (NEC 110.151.
2.4.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.'17 AND
NEC 250.50
THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEOUATE. A
GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC
690.47
AND AHJ.
2.4.10 ACCOROTNG TO NEC 690.47 (CX3), UNGROUNDEO SYSTEMS INVERTER
MAY SIZE DC
GEC ACCORDING TO EGC REOUIREMENTS OF NEC 250.122. HOWEVER. OC GEC
TO BE
UNSPLICEO OR IRREVERSIBLY SPLICEO,
2.4.1 1 IN UNGROUNDED INVERTERS, GROUNO FAULT PROTECTION IS PROVIDEO
BY 'ISOLATION MONITOR INTERRUPTOR,' AND GROUND FAULT DETECTION
PERFORMEO BY'RESIOUAL.CURRENT OETECTOR.'
2.5.1 INTERCONNECTION IOTES:
2.5.2 LOAD-S|DE TNTERCONNECTION SHALL BE lN ACCORDANCE WlrH [NEC
690.64
(B)t
2.5.3 THE SUM OF THE UTILIW OCPO ANO INVERTER CONTINUOUS INPUT MAY
NOT
EXCEED 120vo OF BUSBAR RATTNG [NEC 705.12(DX2X3)].
2.5.4 WHEN SUM OF THE PV SOURCES EQUALS >1OO% OF BUSBAR RATING, PV
OEOICATED SACKFFEO AREAKERS MUST BE LOCATED OPPOSITE ENO OF THE
BUS FROM TBE UTrLrrY SOURCE OCPD [NEC 705.12(DX2X3)].
2.5.5 AT MULTIPLE INVERTERS OUTPUT COMBINER PANEL, TOTAL RATING OF
ALL
OVERCURRENT OEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR.
HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUOED
ACCORDTNG TO NEC 70s.12 (OX2X3XC).
2.5.6 FEEDER TAP TNTERCONECTION (LOAO Sl0E) ACCORDING TO NEC 705.12
(DX2Xr)
2.5.7 SUPPLY SrDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH
SERVICE ENTRANCE CONOUCTORS IN ACCORDANCE wlTH NEC 230.42
2.5.8 BACKFEEDING BREAKER FOR UTILITY]NTERACTIVE IM/ERTER OUTPUT IS
EXEMPT FROM AOOITIONAL FASTENING INEC 70s.12 (DXs)1.
2.G.I DISCOT{NECTION AND OVER4URRENT PROTECTION I{OTES:
2.6.2 OISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE
SwlTCH
IS OPENEO THE CONOUCTORS REMAINING ENERGIZED ARE CONNECTEO TO
THE TERMINATS MARKED "LINE SIDE' (TYPICALLY THE UPPER TERMINALS).
2.6.3 DISCONNECTS TO BE ACCESSIBLE TO OUALIFIED UTILITY PERSONNEL, BE
LOCKABLE. ANO 8E A VISIBLE.BREAK SWTCH.
2.6.4 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDEO.
THEREFORE BOTH MUST OPEN WHERE A OISCONNECT IS REQUIREO,
ACCOROTNG TO NEC 690.t3.
2.6.5 DC OISCONNECT INTEGRATEO INTO ROOFIOP DC COMBINER OR
INSTALLEO
wtTHtN 6 FT, ACCORDING TO N€C 630.15 (C).
2.6.6 RAPID SHUTDOWN OF ENERGIZED CONOUCTORS BEYONO 10 FT OF PV
ARRAY
OR 5 FT INSIOE A BUILDING WITHIN 1O SECONDS. CONTROLLED
ooNDUCTORS <30V ANO 5240VA {NEC 690.121. LOCATION OF LABEL
ACCOROING TO AHJ.
2.6.7 ALT OCPO MTINGS ANO WPES SPECIFIED ACCORDING TO NEC 690.8,
690.9,
ANO 240.
2.6.8 BOTI.I POSITIVE ANO NEGATIVE PV CONOUCTORS ARE UNGROUNDED,
THEREFORE BOTH REOUIRE OVER-CURRENT PROTECTION, ACCOROING TO
NEC 240.21. (SEE EXCEPTION lN NEC 690.S)
2.6.9 IF REOUIRED BY AHJ. SYSTEM WILL INCLUOE ARC.FAULT CIRCUIT
PROTECTION
ACCOROTNG TO NEC 690.11 ANO UL16S98.
2.7.1 \URlilC A COiIDUlr |OTES:
2.7.2 ALL CONOUIT AND WIRE wlLL BE LISTED AND APPROVEO FOR THEIR
PURPOSE.
CONDUIT AND WRE SPECIFICATIONS ARE BASED ON MINIMUM COOE
REOUIREMENTS ANO ARE NOT MEANT TO LIMIT UP-SIZING.
2.7.3 ALL CONOUCTORS SIZED ACCORDING TO NEC 690.E, NEC 690.7.
2.7.4 EXPOSEO UNGROUNOED PV SOURCE AND OUTPUT CIRCUITS SHALL USE
WIRE
LISTED AND IOENTIFIED AS PHOTOVOLTAIC (PV} wlRE 1690.35 (D)I. PV
MOOULES WRE LEADS SHALL BE LISTED FOR USE WITH UNGROUNDED
sysTEMs, AccoRDtNG TO NEC 690.35 (DX3).
2.7.5 PV WIRE ELACK WIRE MAY BE FIEL}UARKEO WHITE INEC 200.6 (AX6)I.
2.7.6 MODULE WRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY.
2.7.7 ACCORDING TO NEC 200,7, UNGROUNDED SYSTEMS DC CONOUCTORS
LEGENDS
JUNCTION BOX
PV INVERTER
NON FUSIBLE
AC DISCONNECT
FUSIBLE
AC DISCONNECT
@ UTILIfr/NET METER
BIOIRECTIONAL
R UTILITY ELECTRIC
GRIOIUTILITY/NET METER
BIDIRECTIONAL
WITH METER MAIN
H-
DC/DC POWER
OPTIMIZERS
RESIDENTIAL
BATTERY OPTION
FLASHING
ATTACHMENTIEGC & GC BONDEO
AND GROUNOEO
@t
SMART/
PRODUCTION
METER
,,*ko.*STRINGS BLACK RAIL
6Ibdb
BACK FEEO
BREAKER
o
ELECTRIC
WIRE TAPS
SOLAR MOOULES
ON THE
ROOF/GROI'NO
I}58o.^6_
E- E6 g g
EE E$ g Etu AB H f;gl=r=
Tz;8
/;\KJ
SUMMIT
ENERGY
SUMMIT ENERGY GROUP
2S3 LIBBEY INDUSTRIAL PKWY,
UNIT 250, WEYMOUTH,
MA02189, USA
888-57856/18
PROJECT ID: MAEVE1 1.55-586
UTILITY: EVERSOURCE
PV2
PROJECT NOTES
ELEI-IL-A-lLA-.lI rElzffi
E
ffi
t'----1G
l*"^lFrIt]k
NOTE: THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE OESIGN
6FT-pnoposeo puorovoLTAlc PowER sYsrEM wlrH ENoucH DETAIL To
DEMONSTRATE COMPLIANCE WITH ALL APPLICABLE COOES ANO REGULATIONS. THE
DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLTOWING
MANUFACTURER INSTALLATION MANUALS. INSTALLER SHALL INSTALL ALL EOUIPMENT IN
ACCORDANCE wlTH MANUFACTURER INSTALLATION MANUALS. NOTHING IN THIS
OOCUMENT SHOULO BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN
MANUFACTURER INSTALLATION MANUALS.
ls$Sffifn,,*'.
SU MMIT
ENERGY
-,?,tiiffl}i --MAIN SEI
(lNslDE)
-AC Dlst''
(tNSlDE)
SUMMIT ENERGY GROUP
293 LIBEEY INDUSTRIAL PKWY.
UNIT 250. WEYMOUTH.
MA 02189. USA
888-57866/t8
I}58
a- Eu * i
*r"q$sE
'**=HE;8
(,!,
(r-
PROJECT lD: MAEVEl'1.55-586
UTILITY: EVERSOURCE
PV3
PLOT PLAN
a\
Z\za
2
-1\Z\o\F
r-]\H\H\
tr\rl
NOTE 1: EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED
SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM
WORKING CLEARANCES PER NEC 1 10.26.
NOTE 2: CONTRACTOR SHALL USE ONLY COMPONENTS LISTEO BY A
NATIONALLY RECOGNIZED TESTING LABOMTORY FOR THE
INTENDEO USE..
NOTE 3: CONTRACTOR lS RESPONSIBLE FOR FURNISHING ALL RELATED
EOUIPMENT, CAALES, ADDITIONAL CONOUITS, BOXES,
MCEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A
COMPLETE AND OPEMTIOML PV SYSTEM.
NOTE 4: THE SYSTEM SHALL COMPLY WITH NEC ARTICLE 690. ALL
MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS,
ANO THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY
HAVING JURISDICTION'S (AHJ) APPLICABLE CODES.
NOTE 5: WHERE oC PV SOURCE OR DC PV OUTPUT CIRCUITS ARE RUN
INSIOE THE BUILDING, THEY SHALL BE CONTAINED IN METAL
MCEWAYS, ryPE MC METALCLAD CABLE, OR METAL
ENCLOSURES FROM THE POINT OF PENETRATION INTO THE
BUILOING TO THE FIRST READILY ACCESSIBLE DISCONNECTING
MEANS, PER NEC 690.31(G)
NOTE 6: ABOVE DIMNSSIONS ARE FOR THE RESPECTIVE ROOF PLANES
MEASURED BETWEEN THE ROOF RIDGE TO THE EVE AND RAKE TO RAKE
LEGENDS:
(M) UTILIWMETER
lMsfl ultr.r sERVtcE PANEL
Eeol nc DlscoNNEcr
FIRE CLEAMNCE
INVERTER
JUNCTION BOX
REC 33OW
STRINGS, MINIMUM 8 MODULES
AND MAX 6,OOOW PER STRING
1'MODULE CLEARANCE
ARRAY 2.
#10, REC 33OW I
#10, sE P3401
TILT 21" I
.ARRAY 1
l*zs, nec esow
l#2s, sE P340
rTtLT 37"
A(_v
SUMMIT
ENERGY
u@m@
SUMMIT ENERGY GROUP
293 LIBBEY INOUSTRIAL PKWY,
UNIT 250, WEYMOUTH,
MA 02189. USA
888-5786648
%E
@
--
I}58o,^o-
8, ir E;g9 o'r v tr
=u,
qH s frEu A= H ilE
=
T=
=zsB
T
,: EVERSOURCE
NOTE: THIS DOCUMENT HAS BEEN CREATED FOR THE PURPoSE oF DESCRIBING Tl'lE DESIGN
OF A PROPOSEO PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH OETAIL TO
OEMONSTRATE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THE
DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING
MANUFACTURER INSTALLATION MANUALS. INSTALLER SHALL INSTALL ALL EOUIPMENT IN
ACCOROANCE wlTH MANUFACTURER INSTALLATION MANUALS. NOTHING IN THIS
DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN
MANUFACTURER INSTALLATION MANUALS.
PV4
SITE PLAN
@ ursurnrueren
i_J:--32'/
-t6tl6ril
Ir-
REC 'I-PEAK BLACK SERIES,
REC330TP3M,330W
SYSTEM INFORMATION
DC SYSTEM SIZE 11.55 KW
AC SYSTEM SIZE 1O KW
MODULE REC ALPHA BLACK
SERIES, 365M, 365W
OPTIMIZER &
INVERTER
SOLAREDGE
TECHNOLOGIES, P340,
SElOOOOH-US
TOTAL ARRAY
AREA 630 SO. FT.
TOTAL NO. OF
MODULES 35
ARMY 1 AZIMUTH 262"
ARRAY 1 PITCH 37"
ARRAY 2 MIMUTH 262"
ARRAY 2 PITCH 21
UTILITY NAME EVEROUSRCE
ARMY 2r
#10, REC 330Wl
#10, sE P340 |
T|LT 21"
I
TARRAY 1
| *zs, nec ssow
| #25, SE P34o
T-
tr--
Iozo
IL
U)
Fzfo
x
cot
2X4
TRUSSES
@24O.C.
LEGENDS.
RAILS
r=----ll= o I MOUNTS/ATTACHMENTS
L_J
NOTE 'l: DIMENSIONS lN RED INK MEASURES THE HORIZONTAL
OISTANCE BETWEEN RIDGE AND THE SIDE WALL
NOTE 2: MOUNTS/ATTACHMENTS SHOULO BE INSTALLED AS PER
MANUFACTURERS INSTRUCTIONS
NOTE 3: FLASHINGS ONCE INSTALLEO SHOULD BE SEALED TO
WATER TIGHT
NOTE 4: lF THE ROOF lS OETERMINED To BE WEEK AT THE
INSTALL, STOP THE WORK AND NOTIFY THE PROJECT ENGINEER
-t
.t
.,
t
.!
I
.,
,
.,
q
.l
t
-f .l
;SUMMIT
ENERGY
SUMMIT ENERGY GROUP
293 LIBBEY INDUSTRIAL PKWY.
UNIT 250. WEYMOUTH.
MA 02189, USA
888-57E46/t8
lD: MAEVE11.55-586
,: EVERSOURCE
I=53
E, Er H ;99 .;= V FAF fE s fi.
HE i3 [ f;* I 13
E8
DEAD LOAD CALCULATIONS
LOA LBS.OTAL LBS
43.00 1505
OPTIMIZERS 35 '1.70 50
LINEAR FEET OF RAIL (ft.)230 0.4 92
ULTRA RAIL COMP KIT 65 0.09 6
SIMPLE GRIP.SO 0 0.09 0
MID CLAMPS 64 0.09 6
END CLAMPS 't2 0.09 1
GROUND WEEBS 6 0.09 1
MISC, HARDWARE 0
TOTAL ARRAY WEIGHT 167
AREA NAME ow.SQ.FT TOTAL SO. FT
MODULES 35 17.98 629.
TOTAL ROOF AREA
% oF ROOF AREA COVEREO BY SOLAT{ PV r/-)
POINT LOAD (TOTAL ARRAY WT./ATTACHMENTS), Lbs/Sq. ft.26
DIST. LOAD CTOTAL ARRAY WT./TOTAL SO.FT.), Lbs/Sq. ft.2.65
ATTACHMENT
OIY.
MODTILES
SNAPNRACK ULTRA
MtL 92O L rcOT SHOWN.
COI..IPATI f wml ULTRA
RAIL ALI P1JRPOSE 9OO L FOOT
A\-_7
SUMMIT
ENERGY
I,IOOULE H€IGHT OFF ROOF, RANGEI L.FOOT TO BASE ATTACHI.IEI.T
OOWNSLOPE FROI4
ROOF PENETMTIONuR-tor 3%'- 1{"
uR-6Or 4%' - 5%"
SNAPNMCK
ULTRA RAIL
FLASHING SHIELDS ENTIRE
ROOF PENTMTION
%e'OL G SCREWS.S.
SUMTIIT ENERGY GROUP
UNIT 250, WEYMOUTH,
!!!{78-6040COMP SIIINGLE ROOFING. TYP.
ROOF O€CKITIG, TYP,
wooo RAmR sHow!,
SIMILAR AT OTHER STRTJCTURAL
MEMEER TYPES
2%" MIN. EMBEDMENT
INTO W@O MEMEER
II58o^6-
E. E, E ;g9 .ir Y tr:fr E+ a 5
=A 9K E E
E* x= H E- (.)ooPENETRATION DETAIL INSTALLED VIEW
I )
CHANNEL NUT
- - RAIL
MID CLAI.,,IP ASSEI'IBLY
TO END OF OOWNSLOPE
SHINGLE COURSE
5/16118 SS BOLT
SS SPLIT LOCK WASHER
(TOROUE TO 16 FT.LBS)
6-12 AWG BARE
COPPER WIRE
SS BONDING PIN I
)-- -
+
SS BONDING
PINS
SNAPNMCK
GROUND LUG
CHANNEL NUTMOOULE
FRAME
RAIL
SNAPNRACK COMP FLASHING
MUSI SUP UNOER I}IE UPSLOPE
SHINGLE COURSE
/\i
SUMMIT
ENERGY
SUMMIT ENERGY GROUP
2$ TIBAEY INDUSTRIAI PKWY,
UNIT 250 WEYMOUTH,
MA02139, USA
888-571a64a
SOL.,8EOGE TECHNOLOGIES
SEIOO@H,US, /VEA,,,A 3R, UL
'/SIEDINTEGRAIEO GFDI ANO OC OISCONNECT,
EOUIPPED WT1] RAPID SHUT OOWN,
COMMUNICATION USING GSM CELL
XIT ANO CELLULAR TOWER TO MONITOR
IX SOTAREOGE PORIAL
60A, 2:IOV AC NON FUSBLE
OISCONNECT
READILY ACCESSIBL€
WT}iIN 3' FROM UTILITY METER
MEIER ' 3r3 330 752
I}58
un *, E E;E *s 3 fi
=; i& u s;d' ii =, Ii > EHiz-oo6
-...i,4N AONDING JUMBER
WITHIN 1O'OFIHEIAP
2OOA MAIN SERVICE PANEL
UT[1ry: EVERSOURCE
NOTE 1: ALL EOUIPMEi{T SHALL gE PROPERLY GROUNDEO PER THE REQUIREMEMTS OF NEC ARTICLES 250 & 690
NOTE 2: PV i,IOOULES SHALL BE GROUNOEO TO MOUNTINC RAILS USING MOOULE TUOS OR RAC(INC INTEGMIED
GFOUNDING CLAMPS }S AILOWEO 8Y LOCAL JURISOICNON, ALL OTHER EXPOSED METAL PARTS SHAIL gE
GROUNOED USING ULTISTEO LAY.IN LUGS,
NOTE3:GROUNDING SYSTEM COMPONENTS SHAII BE LISTED FORTHEIR PURPOSE
NOTE 4: lF THE EXlSTll,lG MAIN SERVICE PANEL 0O€S NOT HAVE A VERIFIASLE GROUNDING EfECTROOE. lT lS THE
CONTRACTOR'S RESPONSBITTry TO hSTALL A SUPPTEMENTAf GROI,.INOING ELECTROOE.
NOTE 5: AC SYS-IEM GROUNoING €LECTRODE CONDUCTOR (GEC)SltALLAE AMINIMUM SIZE TaAWG WHEN
INSULAIEO,
'6AWG
IF &ARE WIRE,
NOIE 6: EOUIPMENTGROUNOING CONoUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICIE 690.45, ANo BE A
MINIMUM OF *1OAWG WIIEN NOT EXPOSEO TO DAMACE ANO
'6AWG
SHaIL BE USED WHEN EXPOSED TO OAMACE
NOTE 7: GROUNOING ANO BONDING CONOUCTORS, lF INSULATEo, SHALL BE COLOR CODED GREEN, OR MARXEO
GREEN IF *IAWG OR LARGER
NOTE A: OISCONNECTING MEANS SHOULO BE ACESSIBLE
WTHIN 10' OF THE SUPPLY SIOE CONNECTION, IT CArl gE
A FUSEO OISCONNECI OR A MANUAILY OP€RATED
NOTE 9: INSTAILATION SHOULD BE NEC2020CODE
NOTE 10: EOUIPMENTSHOUTO BE SERVICE RATEO
NOTE 11: wlRE SIZING SHOU(D BE AS PER 690.31
(NEC2020)
NOTE 12: NEUTRAL AND GROUNO SIIOULO AE AONoEo
ONLYONCE
NOTE 13: SEPARATE GROUND ROD SHOULDBE PV7
ELECTRIC DIAGRAM
WIRE SIZING SCHEOULE
1O AWG PV WIRE COPPER MOOULES ANO OC OPTIMIZER WIRE TO JUNCTION BOX
SYSTEM SUMMARY COM[,,IUN ICATION DIAGRAM
SINGLE INVERTER MI]LTIPTF INVFRTFRS
Z7-z
ffim ffiI
1rz
d ffim=61STRING VOI TAGF
ARFIAY ST' POWFR
31.
SE5YR.KIT l l@ [
BILL OF MATERIALS
CATEGORY MAKE & MODEL QTY DESCRIPTION
MODULE REC TWINPEM BLACK SERIES REC 330W, MONO.CRYSTALLINE
INVERTER SOLAREDGE TECHNOLOGIES SE1 OOOOH-US 1 SElOOOOH.US
POWER OPTIMIZERS SOLAR EDGE P34O 35 SOLAR EDGE 34OW OPTIMIZERS
AC COMBINER PANEL lOOA COMBINER EATON OR EQUI 60A, 24OV AC COMBINER PANEL, NEMA 3R
AC FUSIBLE DISCONNECT SOUARE D DU222NRB OR EOUIV,1 60A, OVER CURRENT PROTECTION DEVICE AS LISTED IN NEC 2017
AC NON FUSIBLE OISCONNECT SQUARE D DU222RB OR EQUIV 1 60A, OVER CURRENT PROTECTION OEVICE AS LISTED IN NEC 2017
JUNCTION BOX EQUIVALENT JUNCTION BOX 3 DC COMBINER ENCLOSURE,6OOVDC, 120A, UL1741, NEMA 3R, CSA C22.2
FUSES MIDNITE SOLAR FUSES OR EOUI.2 60A,24OVAC FUSES
BACK FEED BREAKERYBREAKER CAN MAIN MIDNITE SOLAR FUSES OR EOUI.35A, 2P MOOE OF INTERCONNECTION, MAx MTED VOLTAGE: 240VAC
MA SMART METER / GENERATION METER SOUARE O OVERHEAO OR UNOERGROUNO METER SOCKET 1 2OOA, ,I2OI240V, NEMA 3R SMART METER SOCKET
WIRE SIZING
10 AWG PV WIRE MODULES - OPTMIZERS - JUNCTION BOX
1O AWG THWN-2 COPPER JUNCTION BOX - INVERTER
6 AWG THWN.2 COPPER INVERTER . AC DISCONNECT . SMART METER. AC DISCONNECT
6 AWG THWN-2 COPPER AC DISCONNECT. LINE SIDE TAP - HOUSE/GRID
8 AWG THWN-2 COPPER EGC FOR THE ENTIRE SYSTEM
TRENCH
CONDUIT SIZING
EMT FROM JUNCTION BOX - INVERTER . AC DISCONNECT - METER SOCKET
@
SUMMIT
ENERGY
SUMMIT ENERGY GROUP
293 LIBAEY INDUSTRIAL PKVYY
UNIT 250, WEYMOUTH,
MA 02189, USA
888-578-66.18
oF9uttroT,Zrq
=!f63'
U*
oF
-=53o.-o_s :.:I; E e
dJ !t F
qH s fi
=: u Eq,= < d.X EE
Tz58COMPONENT SPEC!FICATIONS RAILS AND MOUNT INFO
PROJECT lO: MAEVE1 1,55-586
UTILITY: EVERSOURCE
PV8
BILL OF MATERIALS
MODULES
MAKE & MODEL OTY.PMAX PTC tsc voc rEMP. COEFF
OF VOC
FUSE
RATING
REC 33OTP
BLACK 35 330W 246W 10.39A 39.9V 34.3V -O.28 o/ol' C 204
RAIL AND MOUNTS
RAIL RAIL
I,4ODEL MOUNTS TYPE LENGTH I OF RAILS MOUNTS
#OF MID
CLAMPS
# OF ENO
CLAMPS
#oF
GLI.IGS
SNAPNRACK ULTRA
RAIL
ULTRA
RAIL
3OMP KI'T
ALL
BLACK 14'EACH 17 65 64 12 6
POWER OPTIMIZERS
MAKE & MODEL RATEO INPUT
POWER QTY.
MAXIMUM
OUTPUT
CURRENT
MAXIMUM OC
INPUT
CURRENT
MAXIMUM DC
VOLTAGE
WEIGHTED
EFFICIENCY
SOLAR EDGE P34O 340W 35 15A 13.75A 48V 98.8%
INVERTER
MAKE &
MODEL QTY.AC
VOLTAGE GROUNO RATED
POWER
MAX
OUTPUT
CURRENT
MAX INPUT
CURRENT
MAx INPUT
VOLTAGE
cEc
WEIGHTED
EFFICIENCY
SOLAR EDGE
10000 H-us 1 240V FLOATING 10,000w 424 274 480V 990/o
ON METERS, SERVICE PANELS, CONDUITS INVERTER, AC DISCONNECTS
ON ALL CONDUITS, EVERf 10'TURN OFF PHOTOVOLTAIC
AC DISCONNECT PRIOR TO
WORKING INSIDE PANEL
ON MA|N SERVICE PANEL
OAI JUNC|ION BOX ON ROOF
PHOTOVOLTAIC
SYSTEM KWh METER DUAL POWER SUPPLY
SOURCES: UTlLlry GRID AND
PV SOLAR ELECTRIC SYSTEI\,II
OAI S/\,i,4RI MEIER SOCXET
ON Uf1L11'/ ME|ER, MAIN SERVICE PANEL
ON SM,4RT A,€TEF SOCXET
SOLAR CIRCUIT
BREAKER IS BACKFED
DO NOT RELOCATE
THIS OVERCURRENT DEVICE
ON NAIN SERYICE PAI.EL vI/HEN USING
ON AC OISCONNECI NSIDE ANO OUT9DE
NEC 690.s6(CX1)(.)
IF GROUND FAULT IS INDICATED
ALL NORMALLY GROUNDED
CONDUCTORS MAY BE
UNGROUNDE4D AND ENERGIZED
SOLAR PV SYSTEM EQUIPPEO
WITH RAPIO SHUTDOIVN
I
ESS
DUAL POWER SUPPLY
SOURCES: UTILITY GRID AND
PV SOLAR ELECTRIC SYSTEM
ELECTRIC SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITIONur,a,IY cR/4 ESS ANO Py SOL.4F ETECTFiC
ON AlS INVERTER BATTERY CAEINE|
NOTE: PLACARD FORMAT IS PROVIDED FOR REFERENCE. INFORI,{ATIoN FRoM
PV7, THE SINGLE LINE DIAGRAM WILL BE ADDED AND INSTALLEO ON ALL
APPLICABLE UTILITY, STATE AND LOCAL REOUIRED PLACARDS USED FOR THIS
INSTALLATION BEFORE PROJECT INSPECTION ANO COMPLETION
@
SUMMIT
ENERGY
SUI,IMIT EI{ERGY GROUP
293 LBBEY INDUSTRIAI PKVY.
UNIT 25O, WEYMOUTH,
MA02139,USA
88!-57la0aa
T}53
E- E'g;
Eg gx I E
EP Ai E ttr ? ri
6O
PV9
PV IABELS
WARNING: PHOTOVOLTAIC
POWER SOURCE
DC JUNCTION BOX
lwnnrurNc
WARNING
A wnnrurt.tc
PHOTOVOLTAIC SYSTEM
ADc DrscoNNEcrA
OPERATING VOLTAGE
OPERATING CURRENT
MAX SYSTEM VOLTAGE
PHOTOVOLTAIC SYSTEM
EQUIPPED WITH
RAPID SHUTDOWN
o / 111,(c o,scoN/vEcrs
IwanHrnc
ELECTRIC SHOCK HAZARD
PHOTOVOLTAIC SYSTEM
AC DISCONNECT
A WARNINGA
OUAL POWER SUPPLY
ELECTRIC SHOCK HAZARD
OPERATING cURRENTI AMPs
Nomin.l Modul. OpdrtinS T!6pe..lur€ 4a 6'C t f( l
Tomper.tu.e .oeffi.(.t of P" ",.
.0 Y %fC
T.mper.tur€.o.fficieni olv, , 0.:8X/'C
Tihp.rrtur€ (0.f6(i.nr of l. , 0 0{ [/'(
ktuFt.P-.[uhl
w.rCbB Sdtrg.M
WlkWi.er.v.{(V)
Wkcrmt.l."(Al
opdC@lVdtry.V," lvj
tutCkcdlCrrs!.1.r6)
PdEftky(*l
lr5 320 125
q.5 {/rs .0/.s
,35 33.8 !4 |
9.ao 9.s 9.9a
,.1 39.t !9.5
l0"I 10.30 10.36
tl tg.l t91
33S
-ohs
4.5
9.69
402
t0.42
20.0
P6ffitutpt-P,,rUF)
lffiIkvdi.8.-v,r,Nl
lidPoffiCumr-lp"(A)
opackdtwtt .V*(Vl
krCftdr(umr-L 6l
2fi
32.2
7.75
175
8.34
w.eFql.s.mHl -M{ls h&OrH.ryME dtuE*dhd.E(BP*)rslcffih
((tr4"@;
urtol fu .1u!!tu.b IE:€C6llrtrEa617,&st srs r9r0r a 6srmr m7
sard EhId
MbrEcffit k Y6 Y6
i/rmh Aq 6kWHM
Mwniry(rr) I 25 n
kwrrty(Fl 23 25 23
Lewmty{E} O 25 l0
kaYEt 97.51 97.5% 9.54
Mo.lle O.7X 0.X 0.X
PorhYs2S m.X &B &.X
II REC
RET TWINPEAK 3
MONO BLAfK
5ERIE5
PREMIUM SOLAR PANELS
WITH SUPERIOR PERFORMANCE
. ,1, r,)i r, l, . I irl
m -lcTl.\y
#;:,
A?@
iEDUCEStlttXClOf
SYSTEI CO5T5
ffi
SUMMIT ENERGY GROUP
293 LIBBEY INDUSTRIAL PKWY,
UNIT 250. WEYMOUTH,
MA 02189, USA
888-57866,18
SUMMII
ENERGY
CUSTOMER DETAILS
CT lD: MAEVE1'1.55-586
UTILITY: EVERSOURCE
PV 1O
MODULE DATA SHEET
T}58
un :t 3 E
5H E$ t fi
'**=HE-ooo
l\
REf TWINPEAK 3 MOND BLAfK SERIES
tl I .'rq4 l
r
--Jgq-
et
E
! ird)
TIRRATTY
lt 3 3r.s ll 7
l.St 757 76)
lal 36.1 r.8
823 825 829
C.lts 120 hartcel mono-si ptyF P€RC c€|ts
5{rii8rdfI(€llr,iser'ei .
Gl.ir: 013^(32mm)rolil8l.!rw(h Im'r,en.irN"qurIPr.r'h..' IBocksh.t. Hrgnlvree,ir.nrpolv.rl.r i
Po'yor.6n(oiltu.nonlbrs.() b
Fr.ile. A.od,zed.lum,n!il(blackl ;
Juncrionbot. 3.p&r(lh3byE!dlod6l%7,rtd ;I2AWG{4m'lry*r..39'.4711Om. r2-l S
M
YEAR PRTI]..trT WARRANTY
YEAR LT\EAR FIWER TIJTPUT
WARRANTY
0pe.!tron.ltempe..tur!: .40.{85'Ft40.+85'C)
M.rhomsystimvoltrSe 1000V
Des8n load l.), soow 1600 Pa (75 2 lbs/ft:)'
M.nmum toil lo.d l)) 54m Pa l1l2 8 lbr/fr')'
o.ri8n load t): wlnd 1600 Po (13 4 lB/ht)
M.ximun test load (-): 2a00 Pd (50 lb!/ft')'
M.rserieeluser.tinS 204
M.rrd.re.uilent, :04 R'!J.dr.d.!4trt9h trdri 6s*.nlhr o4r.ldlio.'@rfiBr'- r{"! <
D,n.nr'ont 563r19.25rr5(1tr3x997'Snml Y
A,ed ,r*n',,UU-', f
W!l8ht: 4l.7lbtll89r8) &
h spe(frcation5 subje( t lo ria^8. Rith.ul nol,ce
/ Power Optimizer
Power Optimizer
For North America
p320 / p340 / p370 / P40o / P40t / P40s / P48s / Psos
T'o
€mF
oT'+
NmF
For North America
?320 / P340 I p370 / p400 / p40L / p40s / p48s / p50s
PV power optimization at the module-level
, Sp.(ift.lly dcsign d to rcrl with Sol.rEdga I
invcrtert ,
f.rt inst.llation with a singlc bolt
Ncxt generation maintenance with module-
level mnitoring, Up to 2596 lrm mrgy
, Sup.rid.fftktry(99.5*)
, Miti9.t6 .ll typ.s of modub mism.tch lors6,
,rom mrufrturing lolcratrc lo panial
sh.ding
, fl.ribL sFtm dcsign ,q Nimum :9*e
utillzrtlon
solaredge.com
, Mets NEC rcquirerentt for arc fault
protstion (AfCl) and Photovoltaic Rapid
Shuidown Sy3tcm (PVRSS)
, Module-level voltage shutdown tor installer
and fircIight€. rafety
"@- *r"
rffi
.l4@d!6,!dw d@h'Iuaon9{E-tuqledtuc&@hewrcw.sbl@tdtu
It58
a- qu g E
== oJ r FnF x$ s I
EE ;3 H Itr ? Ei
Tz;8
S UMM IT
ENERGY
SUMMIT ENERGY GROUP
293 LIBBEY INOUSTRIAL PI(WY,
UNIT 250, WEYMOUTH,
MA 02t89. USA
EEE-57866,08
w.3ummltaolaromrgry.com
PROJECT ID:
UTILITY: EVERSOURCE
PV 11
I'LPE DATA SHEET
STANDARO COMPTIANCE
Ok@dtudrsrdddE@ieryft k'.&s@b,BreeeH@f,Ca7,se@da.&d l@tu&otc&ffiw*ffi*4o&dihbF&ffi dh,!*erut.M hh(&d-dltfudW,'@h4@&*Uttu!fuffi ()lfu@b@wnd tuffih.4i@dhMryffi 6&*dd*oa.tr@& 6t /.49I Nd.@.* *6k(& rye@k ek(E&
solar@ffi
lqrd4&@Sffi 4b b: &/tutl]@.!t&@rrdd(nrad&bdr@{fs #PtvMrlw4rhdrq@^4*.Ehn${1r66ddx(.dffi @64*beturytrtrffiOrdeF ii&bd0b6@F!qhh,M6tutuS rq 6:@lqtu rrl@S r6tubdwbrt@F iqturturtutfud@81@
Single Phase lnverter 2
mT
-{mF1/r
/ Sinole Phase lnverter
wit6 HD-Wave Technotog! for North America
sE3000H-us / sE3800H-u5 / sEs000H-us / sE6000H-us/
5E7600H-US / SE10000H-US / SE1 1400H-US
with H D-Wave Technology
for North America MdinM{IwOW
sE3000H-us / sE3800H-us / sE5000H-us / sE5000H-us /
sE7500H-US / S810000H-US / SE1 1400H-US
M&lMrGrtftry
Optimized installation with HD-Wave technology
, Spccirk l,t derign d to wt wiih
pore. optimizetr
, Raord-brerking.ffcilmy
, fixrd rcltag€ invrir tq bEU rtd.rgls
, EriEmt rmll
, Suilt-in modulc-lqd mnitoring
, olrtds and irdoor installrtim
, lntry.tcd * fart! Fotcdin ad nfti, tfuidon io. , Optinl: Ra6€ grad" d.ta, ANSI C12.20
i,lEC 20'14 ad 2017, F rrklc 590.11 ild 6$.12 Cl65 0.5 (0.5% {curry)
, Ul,l7.lt SA crrilicd, io. CPt C Ruh 2'l gru
<ffICitrc
solaredge.com solar.EEE
. ffi @i rfr ri al-E ft j4+olxlor9*e-rddq!#r,ri*d't&@E{
reu.hr@.gdt
SUMMIT
ENERGY
SUMMIT ENERGY GROUP
293 LIBBEY INDUSTRIAL PKWY,
UNIT 250, WEYMOUTH,
MA 02189. USA
888-578{6,t8
F=53
;- iu * i
E* qE r E
'**=HEsB
a r&8!tr JD"
o *sirtr -.|D
a
'r:;'
????
I,
:: ?:
o
-- r l,'Dl
a
wa,
a
o
a
a
o
a
?!t
a
RoHS
Snop rock"
Sol!7 Mountlng Solutlonr
Ultra Rail
{J
The Ultimate Value in Rooftop Solar
RESOURCES snapnrack.com/resources
DESIGN snapnrack.com,/configurator
WHERETO BUY snapnrack.com,/where-to-buy
a;\(J
SUMMIT
ENENGY
F}58
a- Eu * ;+= t F
'-E f3 3 fi.rr a: H ttr ? E=
Tz;8
SUMMIT ENERGY GROUP
293 LIBBEY INOUSTRIAL PKWY.
UNIT 250, WEYMOUTH,
MA 02189, USA
8EE-578{648
T
PV 13
SnapNrack Ultra Rail
74 lbs
74 lbs
22 lbs
22lbs
9lbs
9lbs
6.5 lbs
5.5 lbs
ll lbs
-
Comp Shingle Roof Attachm"nt. -1J
Ultra Rail Umbrella L F@t, Silwr 242-01219
Ultia RailUmbrella L Foot, Bltk 242-01220
Ultra Rail Mounting Hardware, Silver 242-01229
Ultra Rail Mounting Hardwaie, Black 242-01230
Ultra Rail All Pu.pose L F@t (9O"), 242-01239
Black
Ultra Rail All Purpose L F@t (9O'), 242-01223
Silver
Comp Flashing,9" x 12", Black Alum 232-01375
(requir6 Umbrella Lag)
Comp Flashang, 9" x 12", Silrer Alum 232-01376
(requi.es Umbrella Lag)
Comp Flashing,9" X 12", Black 232-01377
Galvalume (requires Umbrella Lag)
C
Comp Flashingt
Ultra Rail!mbrella
\
Umbrella Lag
V
Ultra Rail Mounting
Hardwa.e. Black
.._*"..,
s6.oo
t6,70
$2.s6
92.86
1738
$6.68
ts.2s
i4.35
$4.50
ir.75
$.55
5.8 lbs
2.4 lbs
L Foot Extension Kit
Umbrella Lag, 4'
242-O1120
242-92266
$ u**'l;:lt'!8,H,'ii, haHih::"irab* ror arr
".a t,nn," Tool lnstallation AIlSnapNrack Module
Clamps & Accessories
are compatible with
both rail profiles
Start lnstalling Ultra Rail Today