Loading...
HomeMy WebLinkAbout21-A047 J`""`} TOWN OF YARMOUTH f 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451 (� Telephone(508)398-2231 Ext. 1292-Fax(508)398-0836 EC EQ�.l l5 OLD KING'S HIGHWAY HISTORIC DISTRICT C s gi EE D i APPLICATION FOR CERTIFICATE OF APPROPRIATENESS COMMUNITY I DEVELOPMENT Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as amended,for proposed work as described below&on plans,drawings, photographs.&other supplemental info accompanying this application. PLEASE SUBMIT 4 copies OF SPEC SHEET(S),ELEVATIONS,PHOTOS,&SUPPLEMENTAL INFORMATION. Check All Categories That Appl : Indicate type of Building: Commercial ✓ Residential 1) Exterior Buildin Construction: New Building t .Addition Alterations Reroof l l Garage Shed ✓ Solar Panels I Other: (� r t€ ri aHriiw F,' 2) Exterior Painting: Siding Shutters l l Doors Trim Other: 3)Signs/Billboards: ri New Sign Change to Existing Sign '21APR1 1PH2:49 RFC 4)Miscellaneous Structures: Fence IWall E,Flagpole nPool IIOther: Please type or print legibly: Address of proposed work: 31 Hawk's Wing Rd Yarmouth MA 02664 Map/Lot# I 09 / 5_5 Owner(s): Tsvetomir Hristov Phone#:774-408-6015 All applications must be submitted by owner or accompanied by letter from owner approving submittal of pplication. Mailing address: 31 Hawk's Wing Rd Year built: iiii0 I Email: rich@the400east.com Preferred notification method: [7 Phone 12 Email Agent/contractor: Summit Energy Group - Raphaela Cobbett Phone#: 339-201-7769 Mailing Address: 293 Libbey Industrial Pkwy STE 250, Weymouth MA 02189 Email: raphaela.c@summit.solar Preferred notification method: 12 Phone a Email Description of Proposed Work: Installation of a 11.55 kW solar system. Total of 35 solar panels located on the southwest facing roof section. Signed(Owner or agent): /r Date: 03/012j_ Owner/contractor/agent is aware that a permit is required from the Building Department.(Check other departments,also.) If application is approved,approval is subject to a 10-day appeal period required by the Act. This certificate is good for one year from approval date or upon date of expiration of Building Permit,whichever date shall be later. All new construction will be subject to inspection by OKH.OKH-approved plans MUST be available on-site for framing&final inspections. For Committee use only: E Approved Approved with Modifications Denied Applicant shall seek OKH approval for any changes Rcvd Date: ,-•/L-4..- -4 Reason for Denial: Amo„ ` ,r '' —to-these plans prior to the change Cash/CK#: 'Tieing incorporated into the project. Rcvd by: 1, i Signed. APPROVED BY: APPRO 1 45 Days: Richard G-• - Robert Wi .•• ► .r 21 Date Signed: Paula Morrison YA( Rosemary Nicholls •LD KING'S HIGHWAY1 t APPLICATION#: LI- !\OLR GENERAL SPECIFICATION SHEET FOUNDATION: Material:Exposure (Not to exceed 18'): CHIMNEY: Material/Color: ROOF: Material: GUTTERS: Material/Color: SIDING : l\ilaterial/Style: Front: Color: Fronl: DOORS: Qty: _ Material: Style/Size (if not listed/shown on elevations): STORM DOORS: Qty: _ Material: GARAGE DOORS: Qty: _ Mat'l: WINDOWS: QryEilg: Front: Manufacturer/Series: Pitch (7112 min)_Height to Ridge: Sides/Rear: Sides/Rear: 'l x 4 1x5 (Circle one.) Color: Color: Style: Right:Color: Material: COLOR CHIPS TRIM: All windows & doors to be trimmed with: Material: Color: SHUTTERS: MatI: SKYLIGHTS: Qty:_ Fixed Grilles (Reouired): Pattern (6/6.2/1- etc.) Grille TvDe: True Divided Lite: fl Snap-ln: l-l -BLtween ctass:ffeer;]fr1-ngy npptied: l--l Exterio-{--ltntertor STORM WINDOWS: Qty: _ Material: DECK: Size:Decking Mat'l: Railing [/at'l:Style: WALLS/FENCES' (Max 6' height);Height:Mat'l: Style: (Show running footage & location on plot plan.) .Finished side of fence must face oul from fenced in area. UTILITY METERS/HVAC UNITS: Location:Screening: Color:LIGHTS: Qty:Style: Location(s): LIGHT POSTS: Qty:Material: Location(s): Additional information: Style: Paneled Louvered Size Color: Color: Color: Color: Color: 2-General APPLICATION #: oLDKTNG''H*Hli;ry|ro,5rY#881"'f*"tcoMMtrrEE Applicant's (Owner) Name: ABUTTERS'LIST Tsvetomir Hrijor/ I Property Address/Location: 54 Ho,hlK s iltnq R"L ' Hearing Date: q l4Z Notices must be sent to the Applicant and abutters (including owners of land on any public or private street or way) who's property directly abuts or is across the street from the Applicant. Please provide the Assessor's Tax Map and Lot numbers onlv. The OKH Office will send out notices using the addresses as they appear on the most recent applicable tax list. Note: lnstructions for obtaining the abutters Map and Lot numbers can be found on the Old King's Highway Department page on the Town website: www.varmouth.ma.us Map Number Lot Number Applicant I nformation :LC*n b"5 Abutter lnformation:Io1 5r, 1fr 5,t\ Lffi 5"w LO1 5.LL 1ffi 5.f 1-08 7b L08 ?-9 8.2018 Application #:Ll-AD.{t TOWN OF YARMOUTH I146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451 Telephone (508) 398-223 I Ext. 1292 Fax (508) 398-0836 OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE WAIVER OF 45-DAY DETERMINATION The applicant/applicant's agent understands and agrees that due to the current declared National and State public health emergencies the determination of our Application for a Certificate of Appropriateness/Demolition/Exemption may not be made within 45 days of the filing of such application. The applicant agrees to extend the time frame within which a determination is to be made as required by the Old King's Highway Regional Historic District Act. SECTION 9 -Meetings, Hearings, Timefor Making Determinations "As soon as convenient after such public hearing; but in an)) event within forty''-five (45) days after the .filing of application, or within such further time as the applicant shall allow in writing, the Committee shall make a determination on the application." Applicant understands that the review of this application will be scheduled as soon as the situation allows. Applicant/Agent Name (please CrLb"lt Applicant/Agent signature : 312020 Application #' , I -AOq U Prop€rty Location 31 HAWKS WING RO Vision lD 103725 Account # 103725 Map lD 109/ 5.5/ / /Bldg Name Sec# 'l of 1 Card #of State Use 1010 Ptinl9ale 10123n020Bldg # CURRENr OWNER TOPO UTILITIES :TRT / ROAD LOCATION CURRE'VIASSESSMEIVT 815 YARMOUTH, MA HRISTOV TSVETOMIR B NAUMOVA HRISTOV V G PO BOX 205 WEST HARWICH MA 02671 Levei 2 Public Water Paved 2 Suburban Description Code Assesseo Assessed 6 Septic RESIONTL RES LAND '1010 '1010 410,300 '121.900 410,300 121,9004Gas SUPP DATA Att Prcl lD MISC 350 CHANGES BETTERMENTS PLAN # 4811,481 ztP coDE 9999: Gts lD M_308505_E278s9 VOTE VOTE DATE PRIVATE Assoc Pid# VISION To(afl 532.i RECORD )F OWNERSHIP BX.VOUP SALE DATE tu v/t SALE PRICE vc PREY'OUS ASSESSMEN T S ( H'S IO R Y) HRISTOV TSVETOI\4IR B DAVCO BUILDERS LLC GREAT WESTERN ROAD LLC GREAT WESTERN ROAD LLC 29719 28936 19053 19052 0160 0305 0028 0337 06-10-2016 0ea12-2015 09-21-20cA 09-21-20cA o U U U I I 400,000 60,000 100 50,000 UN 1B 1J ,tG Year Year Year 2021 1010 1010 410,300 121,900 2020 1010 1010 365,600 121,900 2019 11010 I 312.100 lroro I 12r,9oo Total 532200 Totall 487500 Tolall EXEMPTIONS OIHER ASSESSMEIVIS This signaturs acknowl€dges a Msit by a Data Collsclor or Assessor Ei-f6ffi I DacriPtim Description Number Cornm lnt Appraised Bldq. Value (Card) Appraised Xf (B) Value (Bldg) Appraised Ob (B) Value (Bldg) Appraised Land Value (Bldg) Special Land Value Total Appraised Parcel Value Valuation Method 407,800 2.500 0 121,900 0 532,200 c Total assEssrlrG NEIGHBORHOOD Nbhd Nbhd Name B Tracing Baich 0040 ,VOIES YELLOWNATUML I/G AG SV2O16: NEWCONS WORK COMPLETE CTH CEILS Total Appraised Parcel Value 532,200 BUILDING PERMIT RECORI VISIT / CHANGE HISTORY Permit ld lssue Date Type Description lnsp Daie o/o Coi^,o Date Comp Comments Date Tvpe ls PurposUResult 14-944 o1-13-2014 NC New Construct 372,500 01-30-2016 100 NC.3 BEDROOI'S, 2 BATHS,10-2+2019 08-032016 01-30-2016 0!03-2015 0141-2014 08-01-2005 Kt\,,1 BH RF LS BH JB 02 02 01 1 CL SV BP BP CY 00 Cyclical Sales Veriflcaton Building Permit Building Permit CYCLICAL 2014 Meas ur+Listed L .,NE VALUA ToMECrrorl B Use Code Oescription Zore Land Type Land Unils Unit Price Size Adj Site lndex Cmd.Nbhd.Nbhd. Adj Notes Location Adjr/stment Adj Unit P 1010 SINGLE FAM M 16,988 SF 1.00000 4 1.00 0040 1.000 FYOT SUBDIV#43 1.0000 7.17 121,900 Tolal Card Land Units 16,988 SF Tota Land Area 0.3900 Total Land 121, 1 7.17 Property Location 3't HAWKS WING RD Vision lD 103725 Account # Map lD 1091 5.51 I I Bldg Name Sec# 1 of 1 State Use 1010 Print Date 1012312020103725Bldg #Card # CONSTRUCTION DETAIL CONSIRUGT'ON D ETAI L (CO N f I N U ED ) Element Cd I Description Element Cd Description FOP 32 Style: Model Grade: Stories: Occupancy Exterior Wall 1 Exterio Wall 2 Roof Structure: Rmf Cover lnteriorWall 1 lnterior Wall 2 Itnt"dor Flr. 1 llnterior Flr 2 lneat Fuel I H""t ryr., lRc rype: lTotal Bedroorns lTotrl Bthrr", lTot t H"rf Baths lTot"l xtr" Firtr. lTot"l R*'nr, ls"tt sty", lxitchen StYe: I I I I I I I I Ranch Residential Average +20 Wood Shingle Gable/Hip Asph/F Gls/Cmp DrywdUSheet Hardwood Gas Forced Air-Duc Central 3 Bedrooms 01 05 1 1 14 03 03 05 103 lo+ lo, 103 t; l. loz loz Average Modern DATA Parcel lcl cl uwne lo.u IB Adtust Iype I god Descriotion I Fac conclo Flr Condo Unit COST / MARKET VALUATION Building Value New Year Built Effective Year Built Depreciation Code Remodel Rating Year Remodeled Depreciation % Functimal Obsd Ext. Cornment Trend Factor Condition Condition % Percent Gmd RCNLD Dep 7o Ow Dep Ow Cornment Misc lmp Ow Misc lmp Ow Comment Cost to Cure Ow Cmt fo Crrre Ow Comment 407 201, A ,762 4 0 0 0 1 100 407,800 UAT FGR BAS UBM 13 17 17 11 FOP 6 't3 1 OB . OUTBUILDING & YARD I I EM5IL) Description Unit Price Yr Blt c Grade Adl.Appr. vatue HTL HEATILATOR B 1 2500.00 2015 100 0.00 2,50C BUTEDTM' SUB.AREA SUMMARY SECTION Code Description Livrnq Area Floor Area Eff Area Unit Cost Undeprec Value BAS CTH FGR FOP UAT UBM First Floor Cathedral Clng Garage Porch, Open, Finished Attic, Unfinished Basement, Unfinished 1,675 0 0 0 0 0 1,O/5 't,675 483 382 483 1,675 1,675 0 '193 76 48 335 172.63 0.00 68.98 34.35 17.16 34.53 2U9,1 5t' 0 33,318 13,120 8,286 57,831 Rl Gross Liv / Lease Area 1,6751 6,371 2,321 401,7 E , tIrl Nffiru,u*" .+i]j- --r1:-,: ;. F .,. {"t 1-P;:--..1:'i . ,rls..'.': i ;,$'1i i. . ':}1 t I HWllii$m ( ,:'',1 t:i l'' Aurora Shade Report customer Rich Hristov Address 3'l Hawk's Wing Rd Yarmouth MA 02664 3 il tl G q I t, ,"a lf ' ?.' t It .r.} Summary ArraY Designer Siddharth Temburni Coordinates (4.1 693545, -70 19651'l) Organization Summit Energy Group Date 10 February202l Panel Count Azimuth (deg.)Pitch (deq.)Annual TOF (%) kWh/m2lyear 2,450 or more Annual Solar Access (7.)Annual TSRF (%) 2,100 1,750 I ,.,, l:" Annual irradiance I 2 Weighted average by panel count Monthly solar access (%) across arrays Array Jan Feb Mar APr o2 87 25 10 J/ 21 90 89 89.9 75 77 75.6 May sepAug e2 90 90 88 84 89 89 88 83 80 88 89 92 92 92 84 89 90 90 92 91 91 aq 81 WTYi1t3 I 262 26? Customer Rich Hristov Address 31 Hawk's Wing Rd Yarmouth MA02664 Designer Siddharth Temburni Coordinates (41 693545, -70.19651 1) Organization Summit Energy Group Date 1 0 February 2021 Zoomed out satellite view 3D model 3D model with LIDAR overlaY r(2i3 19ft 7t,t Customer Rich Hristov Address 31 Hawk's Wing Rd Yarmouth MA 02664 II l, Siddharth Temburni, certify that I have generated this shading report to the best of my abilities, and I believe its contents to be accurate. Designer Siddhafth Temburni Coordinates (41 693545, -70.1 9651 1) Organization Summit Energy GrouP Date 10 February 202'] E I I t ?,.xcxEt Street view and corresponding 3D model 3/3 31 HawlCs Wing Rd Gooqle F. F+: P". F?' E. t' al a lf F' DIRECTORY iT SUMMARY AN- ;ITE PLAN PV5 IATTACHMENTOIAGRAM PV6 ,TTACHMENT DETAILS & ELEVATION 3ELS NEW PV SYSTEM: TSVETOMIR HRISTOV 31 HAWK'S WING RD, YARMOUTH, MA 02664, USA PV SYSTEM RATING (DC): 11.55 Kw (41 .693531, -70.1 96541 ) n\(:y SUMMIT ENERGY SUMMIT ENERGY GROUP 293 LIBBEY INDUSTRIAL PKWY, UNIT 250, WEYMOUTH, MA 02't89, USA 888-578{648 I}53 t- qu s t EE E$ s r tr ? r= =z;8 [-] OESIGN ENGINEER SIODHARTH TEMBURNI NABCEP PVIP CERTIFIED sto@suMMtT.soLAR PROFESSIONAL ENGINEER SCOTT WYSSLING W CONSULTING P.E. STRUCTUML, PP, CME NH LICENSE NO. 15260 (o): (201) 874-3483 SYSTEM INFORMATION DC SYSTEM SIZE 1 1.55 KW AC SYSTEM SIZE 10 KW DC/AC RATIO 1.15 MODULE REC TWINPEAK BLACK SERIES, 330TP3M, 330W MLPgINVERTER SOLAREDGE TECHNOLOGIES, P340, SElOoooH-US RACKING SNAP N RACK ATTACHMENTS ULTRA RAIL COMPK KIT rOTAL ARRAY ARE,A 630 SO. FT. NO- OF MODULES 35 ARRAY 1 AZIMUTH 262' ARRAY 1 PITCH 37'. ARRAY 2 AZIMUTH 262'. ARMY 2 PITCH 21', ARMY 3 AZIMUTH ARRAY 3 PITCH ARRAY 4 AZIMUTH ARRAY 4 PITCH ARRAY 5 AZIMUTH ARRAY 5 PITCH AVERAGE TSRF UTILITY NAME EVERSOURCE REMOTE MONITORING YES STREET VIEW THIS OOCUMENT HAS SEEN PREPARED FOR THE PUPOSE OF OESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WTH ENOUGH OETAIL TO DEMONSTRATE COMPI.IANCE WITHMEffiIE COOES ND ffiGUUTIONS. THE MUMENT S&L NOT SE RELIED UPON AS A SUSSNTUTE FOR FOLLOWING MANUFACTURER INSTALUTION INSTRUCTIONS- CONTRACTOR SHALL INSTAL EQUIPMENT Iil ACCORDANCE WTH MANUFACTURER INSTRUCTIONS ANO NOflING IN THIS OOCUMENT SHIL AE INTERPRETEO IN AWAY THAT OVERRIDES THEM. CONTMCTOR IS RESPONSIBLE FOR OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN DOCUMENT, SITE DETAILS ASHME EXTREME LOW 3.2"F (-16'c) ASHRAE 2% HIGH 82.4"F (28'Cl CLIMATE OATA SOURCE MA, USA (WMO: 725067) WINO SPEED RISK CATEGORY I W|ND EXPOSURE CATEGORY B GROUNO SNOW LOAD 30 PSF INTERCONNECTION DETAILS POINT OF CONNECTION NEW 5UTtsLY >IUE AU CONNECTION PER NEC ARTTCLE 705.12(A) UTILIry SERVICE 12O|24OV 1l ELECTRICAL PANEL 2OOA MAIN SREAKER, 2OOA PANEUBUSS BTM, LINE TAP/SUPPLY SIDE SERVICE ENTRANCE UNDERGROUNO APPLICABLE COOES & STANDARD BUILDING MASSAUHUSEI I S tsUILUINU CODE, gTH EDITION, AS AMENDEO 0m cMRl ELECTRICAL MASSACHUSEI IS ELEUI XIUAL cooE (527 CMR 12.00) NFPA 70E (20'l7NEC) FIRE AASSACHUSE I I 5 UUMPKENENSIVt F|RE SAFETY COOE (527 CMR 1.00) SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALUTION OF SOUR PANELS, THE PANELS WLI SE RACKED USING A PRE- ENGINEERED THE RACKEO MOOULES WILL BE ELECTRICILY CONNECTEO WTH DC rO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHOOS CONSISTENT WTH THE RULES ENFORCED BY THE LOCAL UTILITY ANO PERMITTING JURISDICTION-PV1 PROJECT SUMMARY 2.1.1 sm NorEs: 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2.1.3 THE PV MODULES ARE CONSIOEREO NON-COMEUSTIBLE ANO THIS SYSTEM IS A UTILITY INTEMCTIVE SYSTEM WTH NO STOMGE BATTERIES. 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILOING ROOF VENTS. 2.1.5 PROPER ACCESS AND WORKING CLEAMNCE AROUND EXISTING ANO PROPOSEO ELECTRICAL EOUIPMENT WILL BE PROVIDED AS PER SECTION NEC 1 10.26. 2.,I.6 ROOF COVERINGS SHALL BE DESIGNEO, INSTALLEO, AND MAINTAINED IN ACCORDANCE WITH THIS COOE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE, 2.2.'l EOU|PXETT LOCATIONS 2.2.2 ALL EOUIPMENT SHALL MEET MINIMUM SETBACKS AS REOUIREO BY NEC 1 I0.26. 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPEMTING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A).(C) AND NEC TABLES 310.15 (BX2XA) AND 310.1s (BX3XC). 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNOER PV MOOULES ACCOROTNG TO NEC 690.34. 2.2.4 AODTTTONAL AC OTSCONNECT(S) SHAIL BE PROVTDED WHERE THE INVERTER lS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.5 ALL EOUIPMENT SI-IAI.L BE INSTALLEO ACCESSIBLE TO OUALIFIEO PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTOOOR USAGE WHEN APPROPRIATE. 2.3.I STRUCTURAL XOTES: 2.3.2 MCKING SYSTEM & PV ARMY WILL BE INSTALLED ACCOROING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REOUIRE A OESIGNATED SPACE BETWEEN MODULES, ANO RAILS MUST ALSO EXTEND A MINIMUM OISTANCE BEYOND EITHER EDGE OF THE ARMY/SUBARRAY, ACCORDING TO MIL MANUFACTURER'S INSTRUCTIONS. 2.3.3 JUNCTION 8OX WILL BE INSTAILED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF.PENETMTING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REOUIREMENTS. 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WLL BE COMPLETED AND SEALEO w/APPROVEO CHEMICAL SEALANT PER CODE BY A LICENSEO CONTMCTOR. 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN OISTANCE SPECIFIEO BY THE RACKING MANUFACTURER. 2.3.6 WHEN POSSIALE, ALL PV RELATED MCKING ATTACHMENTS WLL BE STAGGEREO AI.IONGST THE ROOF FRAMING MEMBERS. 2./a.l GROUT{DIIG IOTES: 2.,I.2 GROUNOING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, ANO GROUNOING OEVISES EXPOSEO TO THE ELEMENTS SI.IAI-L BE RATED FOR SUCH USE. 2.4.3 AS IN CONVENTIONAL PV SYSTEMS, UNGROUNDEO PV SYSTEMS REOUIRE AN EOUIPMENT GROUNOING CONDUCTOR. ALL METAL ELECTRICAL EOUIPMENT AND STRUCTURAL COMPONENTS BONOEO TO GROUNO, IN ACCOROANCE WTH 250.I34 OR 250.136(A). ONLY THE OC CONOUCTORS ARE UNGROUNOEO. 2.4.4 PV EQUIPMENT SHALL 8E GROUNOEO ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE 250.I22. 2.4.5 METAL PARTS OF MOOULE FMMES, MOOULE RACKING, ANO ENCLOSURE CONSIDERED GROUNoEo lN ACCORO WITH 250.13,r AND 25o.136(A). 2.,T.6 EACH MODULE WILL BE GROUNOEO USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION ANO APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MOOULE GROUNDING LUGS MUST AE INSTALLED AT THE SPECIFIEO GROUNDING LUG I.IOLES PER THE MANUFACTURERS' INSTALLATION REOUIREMENTS. 2.4.7 THE GROUNOING CONNECTION TO A MODULE SHALL BE ARRANGEO SUCH THAT THE REMOVAL OF A MOOULE OOES NOT INTERRUPT A GROUNOING CONDUCTOR TO ANOTHER MOOULE. 2.iT.8 GROUNOING ANO BONDING CONOUCTORS. IF INSULATEO, SHALL 8E COLOREO GREEN OR MARKEO 6REEN IF #,I AWG OR LARGER INEC 250.119] COLOREO OR ilARKEO A3 FOLLOW3: OC POSITIVE. REO, OR OTHER COLOR EXCLUOING WHITE. GREY ANO GREEN OC NEGATIVE- BLACK, OR OTHER COLOR EXCLUOING WHITE, GREY AND GREEN 2.7.8 AC CONOUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR 12. REO. OR OTHER CONVENTION IF THREE PHASE PHASE C OR L} BLUE, YELLOW OMNGE', OR OTHER CONVENTION NEUTML. WHITE OR GREY. IN 4.WIRE DELTA CONNECTED SYSTEMS THE PHASE WTH I.IIGHER VOLTAGE TO BE MARKED OMNGE (NEC 110.151. 2.4.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.'17 AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEOUATE. A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AHJ. 2.4.10 ACCOROTNG TO NEC 690.47 (CX3), UNGROUNDEO SYSTEMS INVERTER MAY SIZE DC GEC ACCORDING TO EGC REOUIREMENTS OF NEC 250.122. HOWEVER. OC GEC TO BE UNSPLICEO OR IRREVERSIBLY SPLICEO, 2.4.1 1 IN UNGROUNDED INVERTERS, GROUNO FAULT PROTECTION IS PROVIDEO BY 'ISOLATION MONITOR INTERRUPTOR,' AND GROUND FAULT DETECTION PERFORMEO BY'RESIOUAL.CURRENT OETECTOR.' 2.5.1 INTERCONNECTION IOTES: 2.5.2 LOAD-S|DE TNTERCONNECTION SHALL BE lN ACCORDANCE WlrH [NEC 690.64 (B)t 2.5.3 THE SUM OF THE UTILIW OCPO ANO INVERTER CONTINUOUS INPUT MAY NOT EXCEED 120vo OF BUSBAR RATTNG [NEC 705.12(DX2X3)]. 2.5.4 WHEN SUM OF THE PV SOURCES EQUALS >1OO% OF BUSBAR RATING, PV OEOICATED SACKFFEO AREAKERS MUST BE LOCATED OPPOSITE ENO OF THE BUS FROM TBE UTrLrrY SOURCE OCPD [NEC 705.12(DX2X3)]. 2.5.5 AT MULTIPLE INVERTERS OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT OEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUOED ACCORDTNG TO NEC 70s.12 (OX2X3XC). 2.5.6 FEEDER TAP TNTERCONECTION (LOAO Sl0E) ACCORDING TO NEC 705.12 (DX2Xr) 2.5.7 SUPPLY SrDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH SERVICE ENTRANCE CONOUCTORS IN ACCORDANCE wlTH NEC 230.42 2.5.8 BACKFEEDING BREAKER FOR UTILITY]NTERACTIVE IM/ERTER OUTPUT IS EXEMPT FROM AOOITIONAL FASTENING INEC 70s.12 (DXs)1. 2.G.I DISCOT{NECTION AND OVER4URRENT PROTECTION I{OTES: 2.6.2 OISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SwlTCH IS OPENEO THE CONOUCTORS REMAINING ENERGIZED ARE CONNECTEO TO THE TERMINATS MARKED "LINE SIDE' (TYPICALLY THE UPPER TERMINALS). 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO OUALIFIED UTILITY PERSONNEL, BE LOCKABLE. ANO 8E A VISIBLE.BREAK SWTCH. 2.6.4 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDEO. THEREFORE BOTH MUST OPEN WHERE A OISCONNECT IS REQUIREO, ACCOROTNG TO NEC 690.t3. 2.6.5 DC OISCONNECT INTEGRATEO INTO ROOFIOP DC COMBINER OR INSTALLEO wtTHtN 6 FT, ACCORDING TO N€C 630.15 (C). 2.6.6 RAPID SHUTDOWN OF ENERGIZED CONOUCTORS BEYONO 10 FT OF PV ARRAY OR 5 FT INSIOE A BUILDING WITHIN 1O SECONDS. CONTROLLED ooNDUCTORS <30V ANO 5240VA {NEC 690.121. LOCATION OF LABEL ACCOROING TO AHJ. 2.6.7 ALT OCPO MTINGS ANO WPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, ANO 240. 2.6.8 BOTI.I POSITIVE ANO NEGATIVE PV CONOUCTORS ARE UNGROUNDED, THEREFORE BOTH REOUIRE OVER-CURRENT PROTECTION, ACCOROING TO NEC 240.21. (SEE EXCEPTION lN NEC 690.S) 2.6.9 IF REOUIRED BY AHJ. SYSTEM WILL INCLUOE ARC.FAULT CIRCUIT PROTECTION ACCOROTNG TO NEC 690.11 ANO UL16S98. 2.7.1 \URlilC A COiIDUlr |OTES: 2.7.2 ALL CONOUIT AND WIRE wlLL BE LISTED AND APPROVEO FOR THEIR PURPOSE. CONDUIT AND WRE SPECIFICATIONS ARE BASED ON MINIMUM COOE REOUIREMENTS ANO ARE NOT MEANT TO LIMIT UP-SIZING. 2.7.3 ALL CONOUCTORS SIZED ACCORDING TO NEC 690.E, NEC 690.7. 2.7.4 EXPOSEO UNGROUNOED PV SOURCE AND OUTPUT CIRCUITS SHALL USE WIRE LISTED AND IOENTIFIED AS PHOTOVOLTAIC (PV} wlRE 1690.35 (D)I. PV MOOULES WRE LEADS SHALL BE LISTED FOR USE WITH UNGROUNDED sysTEMs, AccoRDtNG TO NEC 690.35 (DX3). 2.7.5 PV WIRE ELACK WIRE MAY BE FIEL}UARKEO WHITE INEC 200.6 (AX6)I. 2.7.6 MODULE WRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY. 2.7.7 ACCORDING TO NEC 200,7, UNGROUNDED SYSTEMS DC CONOUCTORS LEGENDS JUNCTION BOX PV INVERTER NON FUSIBLE AC DISCONNECT FUSIBLE AC DISCONNECT @ UTILIfr/NET METER BIOIRECTIONAL R UTILITY ELECTRIC GRIOIUTILITY/NET METER BIDIRECTIONAL WITH METER MAIN H- DC/DC POWER OPTIMIZERS RESIDENTIAL BATTERY OPTION FLASHING ATTACHMENTIEGC & GC BONDEO AND GROUNOEO @t SMART/ PRODUCTION METER ,,*ko.*STRINGS BLACK RAIL 6Ibdb BACK FEEO BREAKER o ELECTRIC WIRE TAPS SOLAR MOOULES ON THE ROOF/GROI'NO I}58o.^6_ E- E6 g g EE E$ g Etu AB H f;gl=r= Tz;8 /;\KJ SUMMIT ENERGY SUMMIT ENERGY GROUP 2S3 LIBBEY INDUSTRIAL PKWY, UNIT 250, WEYMOUTH, MA02189, USA 888-57856/18 PROJECT ID: MAEVE1 1.55-586 UTILITY: EVERSOURCE PV2 PROJECT NOTES ELEI-IL-A-lLA-.lI rElzffi E ffi t'----1G l*"^lFrIt]k NOTE: THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE OESIGN 6FT-pnoposeo puorovoLTAlc PowER sYsrEM wlrH ENoucH DETAIL To DEMONSTRATE COMPLIANCE WITH ALL APPLICABLE COOES ANO REGULATIONS. THE DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLTOWING MANUFACTURER INSTALLATION MANUALS. INSTALLER SHALL INSTALL ALL EOUIPMENT IN ACCORDANCE wlTH MANUFACTURER INSTALLATION MANUALS. NOTHING IN THIS OOCUMENT SHOULO BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS. ls$Sffifn,,*'. SU MMIT ENERGY -,?,tiiffl}i --MAIN SEI (lNslDE) -AC Dlst'' (tNSlDE) SUMMIT ENERGY GROUP 293 LIBEEY INDUSTRIAL PKWY. UNIT 250. WEYMOUTH. MA 02189. USA 888-57866/t8 I}58 a- Eu * i *r"q$sE '**=HE;8 (,!, (r- PROJECT lD: MAEVEl'1.55-586 UTILITY: EVERSOURCE PV3 PLOT PLAN a\ Z\za 2 -1\Z\o\F r-]\H\H\ tr\rl NOTE 1: EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 1 10.26. NOTE 2: CONTRACTOR SHALL USE ONLY COMPONENTS LISTEO BY A NATIONALLY RECOGNIZED TESTING LABOMTORY FOR THE INTENDEO USE.. NOTE 3: CONTRACTOR lS RESPONSIBLE FOR FURNISHING ALL RELATED EOUIPMENT, CAALES, ADDITIONAL CONOUITS, BOXES, MCEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPEMTIOML PV SYSTEM. NOTE 4: THE SYSTEM SHALL COMPLY WITH NEC ARTICLE 690. ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, ANO THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S (AHJ) APPLICABLE CODES. NOTE 5: WHERE oC PV SOURCE OR DC PV OUTPUT CIRCUITS ARE RUN INSIOE THE BUILDING, THEY SHALL BE CONTAINED IN METAL MCEWAYS, ryPE MC METALCLAD CABLE, OR METAL ENCLOSURES FROM THE POINT OF PENETRATION INTO THE BUILOING TO THE FIRST READILY ACCESSIBLE DISCONNECTING MEANS, PER NEC 690.31(G) NOTE 6: ABOVE DIMNSSIONS ARE FOR THE RESPECTIVE ROOF PLANES MEASURED BETWEEN THE ROOF RIDGE TO THE EVE AND RAKE TO RAKE LEGENDS: (M) UTILIWMETER lMsfl ultr.r sERVtcE PANEL Eeol nc DlscoNNEcr FIRE CLEAMNCE INVERTER JUNCTION BOX REC 33OW STRINGS, MINIMUM 8 MODULES AND MAX 6,OOOW PER STRING 1'MODULE CLEARANCE ARRAY 2. #10, REC 33OW I #10, sE P3401 TILT 21" I .ARRAY 1 l*zs, nec esow l#2s, sE P340 rTtLT 37" A(_v SUMMIT ENERGY u@m@ SUMMIT ENERGY GROUP 293 LIBBEY INOUSTRIAL PKWY, UNIT 250, WEYMOUTH, MA 02189. USA 888-5786648 %E @ -- I}58o,^o- 8, ir E;g9 o'r v tr =u, qH s frEu A= H ilE = T= =zsB T ,: EVERSOURCE NOTE: THIS DOCUMENT HAS BEEN CREATED FOR THE PURPoSE oF DESCRIBING Tl'lE DESIGN OF A PROPOSEO PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH OETAIL TO OEMONSTRATE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION MANUALS. INSTALLER SHALL INSTALL ALL EOUIPMENT IN ACCOROANCE wlTH MANUFACTURER INSTALLATION MANUALS. NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS. PV4 SITE PLAN @ ursurnrueren i_J:--32'/ -t6tl6ril Ir- REC 'I-PEAK BLACK SERIES, REC330TP3M,330W SYSTEM INFORMATION DC SYSTEM SIZE 11.55 KW AC SYSTEM SIZE 1O KW MODULE REC ALPHA BLACK SERIES, 365M, 365W OPTIMIZER & INVERTER SOLAREDGE TECHNOLOGIES, P340, SElOOOOH-US TOTAL ARRAY AREA 630 SO. FT. TOTAL NO. OF MODULES 35 ARMY 1 AZIMUTH 262" ARRAY 1 PITCH 37" ARRAY 2 MIMUTH 262" ARRAY 2 PITCH 21 UTILITY NAME EVEROUSRCE ARMY 2r #10, REC 330Wl #10, sE P340 | T|LT 21" I TARRAY 1 | *zs, nec ssow | #25, SE P34o T- tr-- Iozo IL U) Fzfo x cot 2X4 TRUSSES @24O.C. LEGENDS. RAILS r=----ll= o I MOUNTS/ATTACHMENTS L_J NOTE 'l: DIMENSIONS lN RED INK MEASURES THE HORIZONTAL OISTANCE BETWEEN RIDGE AND THE SIDE WALL NOTE 2: MOUNTS/ATTACHMENTS SHOULO BE INSTALLED AS PER MANUFACTURERS INSTRUCTIONS NOTE 3: FLASHINGS ONCE INSTALLEO SHOULD BE SEALED TO WATER TIGHT NOTE 4: lF THE ROOF lS OETERMINED To BE WEEK AT THE INSTALL, STOP THE WORK AND NOTIFY THE PROJECT ENGINEER -t .t ., t .! I ., , ., q .l t -f .l ;SUMMIT ENERGY SUMMIT ENERGY GROUP 293 LIBBEY INDUSTRIAL PKWY. UNIT 250. WEYMOUTH. MA 02189, USA 888-57E46/t8 lD: MAEVE11.55-586 ,: EVERSOURCE I=53 E, Er H ;99 .;= V FAF fE s fi. HE i3 [ f;* I 13 E8 DEAD LOAD CALCULATIONS LOA LBS.OTAL LBS 43.00 1505 OPTIMIZERS 35 '1.70 50 LINEAR FEET OF RAIL (ft.)230 0.4 92 ULTRA RAIL COMP KIT 65 0.09 6 SIMPLE GRIP.SO 0 0.09 0 MID CLAMPS 64 0.09 6 END CLAMPS 't2 0.09 1 GROUND WEEBS 6 0.09 1 MISC, HARDWARE 0 TOTAL ARRAY WEIGHT 167 AREA NAME ow.SQ.FT TOTAL SO. FT MODULES 35 17.98 629. TOTAL ROOF AREA % oF ROOF AREA COVEREO BY SOLAT{ PV r/-) POINT LOAD (TOTAL ARRAY WT./ATTACHMENTS), Lbs/Sq. ft.26 DIST. LOAD CTOTAL ARRAY WT./TOTAL SO.FT.), Lbs/Sq. ft.2.65 ATTACHMENT OIY. MODTILES SNAPNRACK ULTRA MtL 92O L rcOT SHOWN. COI..IPATI f wml ULTRA RAIL ALI P1JRPOSE 9OO L FOOT A\-_7 SUMMIT ENERGY I,IOOULE H€IGHT OFF ROOF, RANGEI L.FOOT TO BASE ATTACHI.IEI.T OOWNSLOPE FROI4 ROOF PENETMTIONuR-tor 3%'- 1{" uR-6Or 4%' - 5%" SNAPNMCK ULTRA RAIL FLASHING SHIELDS ENTIRE ROOF PENTMTION %e'OL G SCREWS.S. SUMTIIT ENERGY GROUP UNIT 250, WEYMOUTH, !!!{78-6040COMP SIIINGLE ROOFING. TYP. ROOF O€CKITIG, TYP, wooo RAmR sHow!, SIMILAR AT OTHER STRTJCTURAL MEMEER TYPES 2%" MIN. EMBEDMENT INTO W@O MEMEER II58o^6- E. E, E ;g9 .ir Y tr:fr E+ a 5 =A 9K E E E* x= H E- (.)ooPENETRATION DETAIL INSTALLED VIEW I ) CHANNEL NUT - - RAIL MID CLAI.,,IP ASSEI'IBLY TO END OF OOWNSLOPE SHINGLE COURSE 5/16118 SS BOLT SS SPLIT LOCK WASHER (TOROUE TO 16 FT.LBS) 6-12 AWG BARE COPPER WIRE SS BONDING PIN I )-- - + SS BONDING PINS SNAPNMCK GROUND LUG CHANNEL NUTMOOULE FRAME RAIL SNAPNRACK COMP FLASHING MUSI SUP UNOER I}IE UPSLOPE SHINGLE COURSE /\i SUMMIT ENERGY SUMMIT ENERGY GROUP 2$ TIBAEY INDUSTRIAI PKWY, UNIT 250 WEYMOUTH, MA02139, USA 888-571a64a SOL.,8EOGE TECHNOLOGIES SEIOO@H,US, /VEA,,,A 3R, UL '/SIEDINTEGRAIEO GFDI ANO OC OISCONNECT, EOUIPPED WT1] RAPID SHUT OOWN, COMMUNICATION USING GSM CELL XIT ANO CELLULAR TOWER TO MONITOR IX SOTAREOGE PORIAL 60A, 2:IOV AC NON FUSBLE OISCONNECT READILY ACCESSIBL€ WT}iIN 3' FROM UTILITY METER MEIER ' 3r3 330 752 I}58 un *, E E;E *s 3 fi =; i& u s;d' ii =, Ii > EHiz-oo6 -...i,4N AONDING JUMBER WITHIN 1O'OFIHEIAP 2OOA MAIN SERVICE PANEL UT[1ry: EVERSOURCE NOTE 1: ALL EOUIPMEi{T SHALL gE PROPERLY GROUNDEO PER THE REQUIREMEMTS OF NEC ARTICLES 250 & 690 NOTE 2: PV i,IOOULES SHALL BE GROUNOEO TO MOUNTINC RAILS USING MOOULE TUOS OR RAC(INC INTEGMIED GFOUNDING CLAMPS }S AILOWEO 8Y LOCAL JURISOICNON, ALL OTHER EXPOSED METAL PARTS SHAIL gE GROUNOED USING ULTISTEO LAY.IN LUGS, NOTE3:GROUNDING SYSTEM COMPONENTS SHAII BE LISTED FORTHEIR PURPOSE NOTE 4: lF THE EXlSTll,lG MAIN SERVICE PANEL 0O€S NOT HAVE A VERIFIASLE GROUNDING EfECTROOE. lT lS THE CONTRACTOR'S RESPONSBITTry TO hSTALL A SUPPTEMENTAf GROI,.INOING ELECTROOE. NOTE 5: AC SYS-IEM GROUNoING €LECTRODE CONDUCTOR (GEC)SltALLAE AMINIMUM SIZE TaAWG WHEN INSULAIEO, '6AWG IF &ARE WIRE, NOIE 6: EOUIPMENTGROUNOING CONoUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICIE 690.45, ANo BE A MINIMUM OF *1OAWG WIIEN NOT EXPOSEO TO DAMACE ANO '6AWG SHaIL BE USED WHEN EXPOSED TO OAMACE NOTE 7: GROUNOING ANO BONDING CONOUCTORS, lF INSULATEo, SHALL BE COLOR CODED GREEN, OR MARXEO GREEN IF *IAWG OR LARGER NOTE A: OISCONNECTING MEANS SHOULO BE ACESSIBLE WTHIN 10' OF THE SUPPLY SIOE CONNECTION, IT CArl gE A FUSEO OISCONNECI OR A MANUAILY OP€RATED NOTE 9: INSTAILATION SHOULD BE NEC2020CODE NOTE 10: EOUIPMENTSHOUTO BE SERVICE RATEO NOTE 11: wlRE SIZING SHOU(D BE AS PER 690.31 (NEC2020) NOTE 12: NEUTRAL AND GROUNO SIIOULO AE AONoEo ONLYONCE NOTE 13: SEPARATE GROUND ROD SHOULDBE PV7 ELECTRIC DIAGRAM WIRE SIZING SCHEOULE 1O AWG PV WIRE COPPER MOOULES ANO OC OPTIMIZER WIRE TO JUNCTION BOX SYSTEM SUMMARY COM[,,IUN ICATION DIAGRAM SINGLE INVERTER MI]LTIPTF INVFRTFRS Z7-z ffim ffiI 1rz d ffim=61STRING VOI TAGF ARFIAY ST' POWFR 31. SE5YR.KIT l l@ [ BILL OF MATERIALS CATEGORY MAKE & MODEL QTY DESCRIPTION MODULE REC TWINPEM BLACK SERIES REC 330W, MONO.CRYSTALLINE INVERTER SOLAREDGE TECHNOLOGIES SE1 OOOOH-US 1 SElOOOOH.US POWER OPTIMIZERS SOLAR EDGE P34O 35 SOLAR EDGE 34OW OPTIMIZERS AC COMBINER PANEL lOOA COMBINER EATON OR EQUI 60A, 24OV AC COMBINER PANEL, NEMA 3R AC FUSIBLE DISCONNECT SOUARE D DU222NRB OR EOUIV,1 60A, OVER CURRENT PROTECTION DEVICE AS LISTED IN NEC 2017 AC NON FUSIBLE OISCONNECT SQUARE D DU222RB OR EQUIV 1 60A, OVER CURRENT PROTECTION OEVICE AS LISTED IN NEC 2017 JUNCTION BOX EQUIVALENT JUNCTION BOX 3 DC COMBINER ENCLOSURE,6OOVDC, 120A, UL1741, NEMA 3R, CSA C22.2 FUSES MIDNITE SOLAR FUSES OR EOUI.2 60A,24OVAC FUSES BACK FEED BREAKERYBREAKER CAN MAIN MIDNITE SOLAR FUSES OR EOUI.35A, 2P MOOE OF INTERCONNECTION, MAx MTED VOLTAGE: 240VAC MA SMART METER / GENERATION METER SOUARE O OVERHEAO OR UNOERGROUNO METER SOCKET 1 2OOA, ,I2OI240V, NEMA 3R SMART METER SOCKET WIRE SIZING 10 AWG PV WIRE MODULES - OPTMIZERS - JUNCTION BOX 1O AWG THWN-2 COPPER JUNCTION BOX - INVERTER 6 AWG THWN.2 COPPER INVERTER . AC DISCONNECT . SMART METER. AC DISCONNECT 6 AWG THWN-2 COPPER AC DISCONNECT. LINE SIDE TAP - HOUSE/GRID 8 AWG THWN-2 COPPER EGC FOR THE ENTIRE SYSTEM TRENCH CONDUIT SIZING EMT FROM JUNCTION BOX - INVERTER . AC DISCONNECT - METER SOCKET @ SUMMIT ENERGY SUMMIT ENERGY GROUP 293 LIBAEY INDUSTRIAL PKVYY UNIT 250, WEYMOUTH, MA 02189, USA 888-578-66.18 oF9uttroT,Zrq =!f63' U* oF -=53o.-o_s :.:I; E e dJ !t F qH s fi =: u Eq,= < d.X EE Tz58COMPONENT SPEC!FICATIONS RAILS AND MOUNT INFO PROJECT lO: MAEVE1 1,55-586 UTILITY: EVERSOURCE PV8 BILL OF MATERIALS MODULES MAKE & MODEL OTY.PMAX PTC tsc voc rEMP. COEFF OF VOC FUSE RATING REC 33OTP BLACK 35 330W 246W 10.39A 39.9V 34.3V -O.28 o/ol' C 204 RAIL AND MOUNTS RAIL RAIL I,4ODEL MOUNTS TYPE LENGTH I OF RAILS MOUNTS #OF MID CLAMPS # OF ENO CLAMPS #oF GLI.IGS SNAPNRACK ULTRA RAIL ULTRA RAIL 3OMP KI'T ALL BLACK 14'EACH 17 65 64 12 6 POWER OPTIMIZERS MAKE & MODEL RATEO INPUT POWER QTY. MAXIMUM OUTPUT CURRENT MAXIMUM OC INPUT CURRENT MAXIMUM DC VOLTAGE WEIGHTED EFFICIENCY SOLAR EDGE P34O 340W 35 15A 13.75A 48V 98.8% INVERTER MAKE & MODEL QTY.AC VOLTAGE GROUNO RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAx INPUT VOLTAGE cEc WEIGHTED EFFICIENCY SOLAR EDGE 10000 H-us 1 240V FLOATING 10,000w 424 274 480V 990/o ON METERS, SERVICE PANELS, CONDUITS INVERTER, AC DISCONNECTS ON ALL CONDUITS, EVERf 10'TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL ON MA|N SERVICE PANEL OAI JUNC|ION BOX ON ROOF PHOTOVOLTAIC SYSTEM KWh METER DUAL POWER SUPPLY SOURCES: UTlLlry GRID AND PV SOLAR ELECTRIC SYSTEI\,II OAI S/\,i,4RI MEIER SOCXET ON Uf1L11'/ ME|ER, MAIN SERVICE PANEL ON SM,4RT A,€TEF SOCXET SOLAR CIRCUIT BREAKER IS BACKFED DO NOT RELOCATE THIS OVERCURRENT DEVICE ON NAIN SERYICE PAI.EL vI/HEN USING ON AC OISCONNECI NSIDE ANO OUT9DE NEC 690.s6(CX1)(.) IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDE4D AND ENERGIZED SOLAR PV SYSTEM EQUIPPEO WITH RAPIO SHUTDOIVN I ESS DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITIONur,a,IY cR/4 ESS ANO Py SOL.4F ETECTFiC ON AlS INVERTER BATTERY CAEINE| NOTE: PLACARD FORMAT IS PROVIDED FOR REFERENCE. INFORI,{ATIoN FRoM PV7, THE SINGLE LINE DIAGRAM WILL BE ADDED AND INSTALLEO ON ALL APPLICABLE UTILITY, STATE AND LOCAL REOUIRED PLACARDS USED FOR THIS INSTALLATION BEFORE PROJECT INSPECTION ANO COMPLETION @ SUMMIT ENERGY SUI,IMIT EI{ERGY GROUP 293 LBBEY INDUSTRIAI PKVY. UNIT 25O, WEYMOUTH, MA02139,USA 88!-57la0aa T}53 E- E'g; Eg gx I E EP Ai E ttr ? ri 6O PV9 PV IABELS WARNING: PHOTOVOLTAIC POWER SOURCE DC JUNCTION BOX lwnnrurNc WARNING A wnnrurt.tc PHOTOVOLTAIC SYSTEM ADc DrscoNNEcrA OPERATING VOLTAGE OPERATING CURRENT MAX SYSTEM VOLTAGE PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN o / 111,(c o,scoN/vEcrs IwanHrnc ELECTRIC SHOCK HAZARD PHOTOVOLTAIC SYSTEM AC DISCONNECT A WARNINGA OUAL POWER SUPPLY ELECTRIC SHOCK HAZARD OPERATING cURRENTI AMPs Nomin.l Modul. OpdrtinS T!6pe..lur€ 4a 6'C t f( l Tomper.tu.e .oeffi.(.t of P" ",. .0 Y %fC T.mper.tur€.o.fficieni olv, , 0.:8X/'C Tihp.rrtur€ (0.f6(i.nr of l. , 0 0{ [/'( ktuFt.P-.[uhl w.rCbB Sdtrg.M WlkWi.er.v.{(V) Wkcrmt.l."(Al opdC@lVdtry.V," lvj tutCkcdlCrrs!.1.r6) PdEftky(*l lr5 320 125 q.5 {/rs .0/.s ,35 33.8 !4 | 9.ao 9.s 9.9a ,.1 39.t !9.5 l0"I 10.30 10.36 tl tg.l t91 33S -ohs 4.5 9.69 402 t0.42 20.0 P6ffitutpt-P,,rUF) lffiIkvdi.8.-v,r,Nl lidPoffiCumr-lp"(A) opackdtwtt .V*(Vl krCftdr(umr-L 6l 2fi 32.2 7.75 175 8.34 w.eFql.s.mHl -M{ls h&OrH.ryME dtuE*dhd.E(BP*)rslcffih ((tr4"@; urtol fu .1u!!tu.b IE:€C6llrtrEa617,&st srs r9r0r a 6srmr m7 sard EhId MbrEcffit k Y6 Y6 i/rmh Aq 6kWHM Mwniry(rr) I 25 n kwrrty(Fl 23 25 23 Lewmty{E} O 25 l0 kaYEt 97.51 97.5% 9.54 Mo.lle O.7X 0.X 0.X PorhYs2S m.X &B &.X II REC RET TWINPEAK 3 MONO BLAfK 5ERIE5 PREMIUM SOLAR PANELS WITH SUPERIOR PERFORMANCE . ,1, r,)i r, l, . I irl m -lcTl.\y #;:, A?@ iEDUCEStlttXClOf SYSTEI CO5T5 ffi SUMMIT ENERGY GROUP 293 LIBBEY INDUSTRIAL PKWY, UNIT 250. WEYMOUTH, MA 02189, USA 888-57866,18 SUMMII ENERGY CUSTOMER DETAILS CT lD: MAEVE1'1.55-586 UTILITY: EVERSOURCE PV 1O MODULE DATA SHEET T}58 un :t 3 E 5H E$ t fi '**=HE-ooo l\ REf TWINPEAK 3 MOND BLAfK SERIES tl I .'rq4 l r --Jgq- et E ! ird) TIRRATTY lt 3 3r.s ll 7 l.St 757 76) lal 36.1 r.8 823 825 829 C.lts 120 hartcel mono-si ptyF P€RC c€|ts 5{rii8rdfI(€llr,iser'ei . Gl.ir: 013^(32mm)rolil8l.!rw(h Im'r,en.irN"qurIPr.r'h..' IBocksh.t. Hrgnlvree,ir.nrpolv.rl.r i Po'yor.6n(oiltu.nonlbrs.() b Fr.ile. A.od,zed.lum,n!il(blackl ; Juncrionbot. 3.p&r(lh3byE!dlod6l%7,rtd ;I2AWG{4m'lry*r..39'.4711Om. r2-l S M YEAR PRTI]..trT WARRANTY YEAR LT\EAR FIWER TIJTPUT WARRANTY 0pe.!tron.ltempe..tur!: .40.{85'Ft40.+85'C) M.rhomsystimvoltrSe 1000V Des8n load l.), soow 1600 Pa (75 2 lbs/ft:)' M.nmum toil lo.d l)) 54m Pa l1l2 8 lbr/fr')' o.ri8n load t): wlnd 1600 Po (13 4 lB/ht) M.ximun test load (-): 2a00 Pd (50 lb!/ft')' M.rserieeluser.tinS 204 M.rrd.re.uilent, :04 R'!J.dr.d.!4trt9h trdri 6s*.nlhr o4r.ldlio.'@rfiBr'- r{"! < D,n.nr'ont 563r19.25rr5(1tr3x997'Snml Y A,ed ,r*n',,UU-', f W!l8ht: 4l.7lbtll89r8) & h spe(frcation5 subje( t lo ria^8. Rith.ul nol,ce / Power Optimizer Power Optimizer For North America p320 / p340 / p370 / P40o / P40t / P40s / P48s / Psos T'o €mF oT'+ NmF For North America ?320 / P340 I p370 / p400 / p40L / p40s / p48s / p50s PV power optimization at the module-level , Sp.(ift.lly dcsign d to rcrl with Sol.rEdga I invcrtert , f.rt inst.llation with a singlc bolt Ncxt generation maintenance with module- level mnitoring, Up to 2596 lrm mrgy , Sup.rid.fftktry(99.5*) , Miti9.t6 .ll typ.s of modub mism.tch lors6, ,rom mrufrturing lolcratrc lo panial sh.ding , fl.ribL sFtm dcsign ,q Nimum :9*e utillzrtlon solaredge.com , Mets NEC rcquirerentt for arc fault protstion (AfCl) and Photovoltaic Rapid Shuidown Sy3tcm (PVRSS) , Module-level voltage shutdown tor installer and fircIight€. rafety "@- *r" rffi .l4@d!6,!dw d@h'Iuaon9{E-tuqledtuc&@hewrcw.sbl@tdtu It58 a- qu g E == oJ r FnF x$ s I EE ;3 H Itr ? Ei Tz;8 S UMM IT ENERGY SUMMIT ENERGY GROUP 293 LIBBEY INOUSTRIAL PI(WY, UNIT 250, WEYMOUTH, MA 02t89. USA EEE-57866,08 w.3ummltaolaromrgry.com PROJECT ID: UTILITY: EVERSOURCE PV 11 I'LPE DATA SHEET STANDARO COMPTIANCE Ok@dtudrsrdddE@ieryft k'.&s@b,BreeeH@f,Ca7,se@da.&d l@tu&otc&ffiw*ffi*4o&dihbF&ffi dh,!*erut.M hh(&d-dltfudW,'@h4@&*Uttu!fuffi ()lfu@b@wnd tuffih.4i@dhMryffi 6&*dd*oa.tr@& 6t /.49I Nd.@.* *6k(& rye@k ek(E& solar@ffi lqrd4&@Sffi 4b b: &/tutl]@.!t&@rrdd(nrad&bdr@{fs #PtvMrlw4rhdrq@^4*.Ehn${1r66ddx(.dffi @64*beturytrtrffiOrdeF ii&bd0b6@F!qhh,M6tutuS rq 6:@lqtu rrl@S r6tubdwbrt@F iqturturtutfud@81@ Single Phase lnverter 2 mT -{mF1/r / Sinole Phase lnverter wit6 HD-Wave Technotog! for North America sE3000H-us / sE3800H-u5 / sEs000H-us / sE6000H-us/ 5E7600H-US / SE10000H-US / SE1 1400H-US with H D-Wave Technology for North America MdinM{IwOW sE3000H-us / sE3800H-us / sE5000H-us / sE5000H-us / sE7500H-US / S810000H-US / SE1 1400H-US M&lMrGrtftry Optimized installation with HD-Wave technology , Spccirk l,t derign d to wt wiih pore. optimizetr , Raord-brerking.ffcilmy , fixrd rcltag€ invrir tq bEU rtd.rgls , EriEmt rmll , Suilt-in modulc-lqd mnitoring , olrtds and irdoor installrtim , lntry.tcd * fart! Fotcdin ad nfti, tfuidon io. , Optinl: Ra6€ grad" d.ta, ANSI C12.20 i,lEC 20'14 ad 2017, F rrklc 590.11 ild 6$.12 Cl65 0.5 (0.5% {curry) , Ul,l7.lt SA crrilicd, io. CPt C Ruh 2'l gru <ffICitrc solaredge.com solar.EEE . ffi @i rfr ri al-E ft j4+olxlor9*e-rddq!#r,ri*d't&@E{ reu.hr@.gdt SUMMIT ENERGY SUMMIT ENERGY GROUP 293 LIBBEY INDUSTRIAL PKWY, UNIT 250, WEYMOUTH, MA 02189. USA 888-578{6,t8 F=53 ;- iu * i E* qE r E '**=HEsB a r&8!tr JD" o *sirtr -.|D a 'r:;' ???? I, :: ?: o -- r l,'Dl a wa, a o a a o a ?!t a RoHS Snop rock" Sol!7 Mountlng Solutlonr Ultra Rail {J The Ultimate Value in Rooftop Solar RESOURCES snapnrack.com/resources DESIGN snapnrack.com,/configurator WHERETO BUY snapnrack.com,/where-to-buy a;\(J SUMMIT ENENGY F}58 a- Eu * ;+= t F '-E f3 3 fi.rr a: H ttr ? E= Tz;8 SUMMIT ENERGY GROUP 293 LIBBEY INOUSTRIAL PKWY. UNIT 250, WEYMOUTH, MA 02189, USA 8EE-578{648 T PV 13 SnapNrack Ultra Rail 74 lbs 74 lbs 22 lbs 22lbs 9lbs 9lbs 6.5 lbs 5.5 lbs ll lbs - Comp Shingle Roof Attachm"nt. -1J Ultra Rail Umbrella L F@t, Silwr 242-01219 Ultia RailUmbrella L Foot, Bltk 242-01220 Ultra Rail Mounting Hardware, Silver 242-01229 Ultra Rail Mounting Hardwaie, Black 242-01230 Ultra Rail All Pu.pose L F@t (9O"), 242-01239 Black Ultra Rail All Purpose L F@t (9O'), 242-01223 Silver Comp Flashing,9" x 12", Black Alum 232-01375 (requir6 Umbrella Lag) Comp Flashang, 9" x 12", Silrer Alum 232-01376 (requi.es Umbrella Lag) Comp Flashing,9" X 12", Black 232-01377 Galvalume (requires Umbrella Lag) C Comp Flashingt Ultra Rail!mbrella \ Umbrella Lag V Ultra Rail Mounting Hardwa.e. Black .._*".., s6.oo t6,70 $2.s6 92.86 1738 $6.68 ts.2s i4.35 $4.50 ir.75 $.55 5.8 lbs 2.4 lbs L Foot Extension Kit Umbrella Lag, 4' 242-O1120 242-92266 $ u**'l;:lt'!8,H,'ii, haHih::"irab* ror arr ".a t,nn," Tool lnstallation AIlSnapNrack Module Clamps & Accessories are compatible with both rail profiles Start lnstalling Ultra Rail Today