HomeMy WebLinkAboutBLD-21-5074 Home Energy Rating Certificate Rating Date:9/20/21
Registry ID:898251109
Final Report Ekotrope ID:YdxPpkkd
HERS® Index Score: Annual Savings Home:
Your home's HERS score is a relative 104 Pleasant St
performance score.The lower the number, $91 5 the more energy efficient the home.To
S.Ydfmouth,MA 02664
Builder:
learn more,visit www.hersindex.com 'Relative to an average U.S.home
Your Home's Estimated Energy Use: This home meets or exceeds the
Use[MBtu] Annual Cost criteria of the following:
Heating 37.2 $191 2018 International Energy Conservation Code
Cooling 0.3 $9
Hot Water 13.3 $67
Lights/Appliances 18.5 $517
Service Charges $120
Generation(e.g.Solar) 0.0 50
Total: 69.3 $9O3
HERS'Index Homo Feature Summary: Rating Completed by:
••.e*, Home Type: - Single family detached
Model: N/A Energy Rater:Cristlan Barta
RESNET ID:1937320
besting Community: N/A
Conditioned Floor Area: 2,161 ft' Rating Company:Outer Cape Energy
Number of Bedrooms: 3 PO Box 1799,N.Eastham,MA,02651
Reference ee 774-801-9431
s Primary Heating System: Furnace•Natural Gas•97 AFUE
w Primary Cooling System: Air Source Heat Pump•Electric•145 SEER Rating Provider:Performance Systems Development
w 124 Brindley Street,Ithaca NY 14850
Residential Water Heater•Natural Gas•0.72 Energy
Iv Primary Water Heating: Factor 607-277-6240 '•`
r
House Tightness: 937 CFM50(2.95 ACH50) '
Ventilation: 56 CFM•19.6 Watts(Default)
w ••s—,, :n^`•
Duct Leakage to Outside: 39 CFM @ 25Pa(3.26/100 ft')20
( ...
Above Grade Walls: R-21 1.uJhai JaZ`a
Zero t o Ceiling: Attic,R-09
Cristian Berta,Certified Energy Rater
N.. `^•r"•'s• Window Type: U-Value:0.3,SHGC:0.28 Digitally signed:9/23/21 at 11:16 AM
Foundation Walls: N/A
ekotropeEkotropeRATER-Version3.2.2.2749
p The Energy Rating Disclosure for this home is available from the Approved Rating Provider.
This -••rt does not constitute.. warran or•uarantee
Air Leakage Report
Property Organization Inspection Status
104 Pleasant St Outer Cape Energy 9/20/21
S.Yarmouth. MA 02664 Cristian Berta Rater ID(RTIN): 1937320
RESNET Registered
104PIeasantStYarmouth155C Builder (Confirmed)
General Information
Conditioned Floor Area [ft') 2.161
Infiltration Volume [ft3] 19,038
Number of Bedrooms 3
Air Leakage
Measured Infiltration 937 CFM50 (2.95 ACH50)
ACH50 (Calculated) 2.95
ELA[sq. in.] (Calculated) 51.54
ELA per 100 s.f. Shell Area (Calculated) 1.051
CFM50 (Calculated) '937
CFM50/s.f. Shell Area (Calculated) 0.191
Duct Leakage
System 1 System 2
Leakage to Outdoors 39 CFM @ 25Pa 30 CFM @ 25Pa (3.11
(3.26/ 100 ft2) / 100 ft2)
Total Leakage Test Type Post-Construction Post-Construction
Total Leakage [CFM @ 25 Pa] 39.0 30.0
Total Leakage [CFM25 / 100 s.f.] 3.3 3.1
Total Leakage [CFM25 /CFA] 0.033 0.031
Mechanical Ventilation
Rate [CFM] 56 CFM
Hours per day 24.0
Fan Power 19.6 Watts (Default)
Recovery Efficiency eio 0.0
Runs at least once every 3 hrs? true
Average Rate[CFM] 56.0 CFM
2010 ASHRAE 62.2 Req. Cont. Ventilation 51.6
2013 ASHRAE 62.2 Req. Cont. Ventilation 56.0
Ekotrope RATER-Version 3.2.2.2749