HomeMy WebLinkAboutEngineer Plan - 2021.1.
Yarmouth Health Departme
APPROVED
Name Dat
cl
�t d
O r
m �
CB D.H. C0
FND 7
I
I
I
I
I
I
110
m
06 r'
1 � / 10 /
.106
1
s.
NO& PE
102
0�
0
1 CB D.H.
FND
I
PROJECT BENCH MARK I
TOP OF FOUNDATION i
u ELEV. = 100.00 (Assumed)
CB
A8+ 21 +E FND D.H.
I
e N LOT 45 j98I
160'p26,f85 Square Feet
FAILED /
/ OEACH PIT GARAGE �
I \ I
\ I�
ASP�LT \
(EXIST. TANK DRIVWAY
1000 gal. 3 SEASON
Septic Tank�'+i",,,/�
ROOM EXISTING
2 BEDROOM
0 HOUSE
O
#11
? T HOLE #10.0
43
NT /
PE / /
0 20
/
/
SCALE: 1"=20'
i
GENERAL NOTES
1. Contractor is responsible for Digsafe notification, Verification of Utilities
and protection of all underground utilities and pipes.
-"" 2. The septic tank aPl distri ution box shall be set
level on 6 of 3/4 —1 1%2" stone.
3. Backfill should be clean sand or gravel with no
stones over 3" in size.
" 4. This system is subject to inspection during installation
by Carmen E. Shay — Environmental Services, Inc.
5, The contractor shall install this system in accordance
t` with Title V of the Massachusetts state code, the approved plan
and Local Regulations.
6. If, during installation the contractor encounters any
soil conditions or site conditions that are different
from those shown on the soil log or in our design
installation must halt & immediate notification be
made to Carmen E. Shay — Environmental Services, Inc.
7. No vehicle or heavy machinery shall drive over the
septic system unless noted as H-20 septic components.
B. Install Tuf—Tate gas baffles or equals on all outlet tee ends.
9. All Distribution Lines shall be 4" diameter Schedule 40 NSF PVC pipes.
10. All solid piping, tees & fittings shall be 4" diameter
Schedule 40 NSF PVC pipes with water tight joints.
11. Municipal Water is Connected to ALL OF The Residence and Abutting
Properties Within 150 Feet.
THE PROPERTY LINES ARE APPROXIMATE AND
COMPILED FROM THE PLAN BY YANKEE SURVEY CONSULTANTS, M MILLS, MA
-I DEPT. ENTITLED "PLOT PLAN OF LAND -11 HLYARD RD., YARMOUTHPORT, MA"
DATED MARCH 1AUGUST 16, 2002
AND IS NOT INTENDED TO BE A SURVEY PLOT PLAN
IT SHOULD BE USED FOR NO PURPOSE OTHER THAN
THE SEPTIC SYSTEM INSTALLATION.
EXISTING SAS TO BE PUMPED OUT AND FILLED IN PLACE
NOTE: ANY STRIPPED OUT SOIL CONTAINING LEACHATE
FROM THE EXISTING SAS TO BE DISPOSED
OF AS PER BOARD OF .HEALTH SPECIFICATIONS.
REV.: 7/7/2021—Per BOH Review and Comments on 7/2/21
40 50
VARIANCE REQUEST:
y
1: '12equest to locate SAS more than 3 feet below grade.
A Vent Pipe and H2O components have been specified.
PLOT PLAN
OF PROPOSED SEPTIC SYSTEM UPGRADE
PREPARED FOR
DAVID SLIWOSKI
11 HALYARD ROAD
PARCEL ID: MAP 135 PARCEL 32
YARMOUTHPORT MA
^a > PREPARED BY:
r� CARMEN E. SHA Y
ENVIRONMENTAL SERVICES
NO 201 PLUM HOLLOW ROAD
EAST FALMOUTH MA 02536
TEL/FAX : 508-294-•7498
SCALE: I"=20' DRAWN BY: CES DATE: JUNE 7, 2021
PROJECT#11 HALYARD FILENAME: 11 HALYARD.d g SHEET 1 OF 2
INLET
10' min.
EXISTING Foundation house. to s}
CONCRETE FULL
S - 0.02
12'
VENT PIPEi(O Least 24 Roche® tglQ
*NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. Schedule 40 PVC w/Charcoal Odor Filter
auryin tank of (In RAd bs
wiRhin a In. of finlehed Brod¢ D -BOX "over RADE be SAS cover must be
within 8" M GRADE within e' of GRADE
bade ow Sptic Tank - ee.90 Kkatle ow O -Box - 102.00 Grose owr SAS - 10200
3 HOLE gin ./—TOP OF SAS f
„c-„-- n ru _ (H-20) DIST. BOX
IST. 1,000 W
SEPTIC TANK
H-10
a. t
SYSTEM PROFILE m
Not to Scale �
NOTE: ALLCOMPONENTS MUST HAVE RISERS TO WITHIN 6" BELOW GRADE BcM.of
s' -7-
STEEL REINFORCED PRECAST CONCRETE
PLAN VIEW
3-24" REMOVA LE COVERS
min, Inlet to ou6al Cmh
TU_V=Wl— OUTLET
E�10 ae, Delo.
I�
NOT TO SCALE
THE ACCESS COVERS FOR THE SEP710 TANK,
DISTPoBUIION BOX AND LEACHING COMPONENT
SET DEEPER THAN a INCHES BELOW FINISHED
GRADE SHALL BE RAISED TO 'WITHIN 6" OF
RNISHED GRADE,.
INSTALL NF -RTE GAS BAFFLES OR EQUALS
TYPICAL 1000 GALLON SEPTIC TANK
Design Calculations Number of Bedrooms: 2 Equivalent to 220 Gal: ay 330 Gal. ay per Title v
Garbage Grinder: No
Leaching Capacity Proposed: 330.GoL/Day Minimum (Min. Per Title V)
Septic Tank : - 2 x330 Gal./Doy.- 660 USE EXIST. 1.000 GAL Septic Tank.
SOIL ABSORPTION AREA: Using percolation rate of Q min./Inch
Bottom Area: 0.74 gal/day/sq. ft. x 325sq. ft. = 240.5 gallons/day
Sidewall Area: 0.74 gal./day/sq, ft. x 152 sq. ft. = 112.50 gallon/day
Providing: = 352.98 gallons/day
Use: (2) 500 H-20 CONCRETE CHAMBERS, HAVING A 2' EFFECTIVE DEPTH,
(5' W x 8.5' L) TO BE USED 'NTH 4' OF WASHED STONE ON THE SIDES AND
4' OF WASHED STONE ON THE ENDS.
is,
'-1 1/2"
atone
maw* sole
SECTION A -A
PROFILE VIEW OF LEACHINC SYSTEM
b f f/I - letlx! afaeAed *bee —.
INSPECTION *owr Ruet be
wRhin 6 In. of finished glide
B Lkdte B 8.5' :
V W - f/d" Fuied TeWh,1r
vgth a Eff¢ctive LenBtH
�8 SOIL ABSORPTION SYSTEM (SAS).
aT 2-500 GALLON H2O CHAMBERS LEACHING UNITS / WIGGINS PRECAST
t Hole 1 Elev.- 89.00 Not to Scale
PERCOLATION TEST
Date of Percolation Test: JUNE 2, 2021
Test Performed By. CARMEN E. SHAY, R.S., C.S.E.
tesults Witnessed By..PHIL RENAUD (YARMOUTH BOH)
EXCAVATOR: CARMEN SHAY
Percolation Rate: Less Than 2 MPI 030"
Test Hole
No. 1
DEPTH SOILS_ ELEV.
_ _
0 100.00
Sandy
Loom
10 YR 3/2
A.
99.50
Sandy
Loam
10 YR 5/6
6"- W.
B.
97.50
Algid. -Fine
Sand
25 Y 7/4
30"- 132
Cn
89.00
Pere #1
Depth to Perc:30" to 48"
Pere Rate= 2 MPI ASSUMED
Groundwater Not Observed
No Observed ESHWT
ADJUSTED H2O Elev. - None
Fr.
3 - 6" aTET
KNOCKOUTS
IY
,---,ae- 4" - SCH. 40 Tee 1.75'-1
PLAN SECTION CROSS-SECTION
3 HOLE H-20 DISTRIBUTION BOX
REV.: 7/7/2021 -Per .BOH Review and Comments on 7/2/21
PAT PLAN
OF PROPOSED SEPTIC SYSTEM UPGRADE
PREPARED FOR
DAVID S TIWOSKI
11 HALYARD ROAD
PARCEL ID: MAP 135 PARCEL 32
YARMOUTHPORT. MA
PROJECT#11 HALYARD
QED BY:
Y ENVIRONMENTAL SERVICES
PLUM HOLLOW ROAD
FALMOUTH MA 02536
FAX : 508-294-7498
DRAWN BY: CES
FILENAME: 11 HALYARD.
DATE: JUNE 7, 2021
SHEET 2 OF 2