HomeMy WebLinkAboutEngineer Plans - 20212' PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO GRADE 8 5MINIMUM .75 OF C SYSTEM PROFILE (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVER TO WITHIN 6" OF FIN. GRADE 9% SIOPF RFOUIRED OVER SYSTEM NOTE: 2" MIN. WALL PRECAST H-10 THICKNESS REQUIRED RISERS (TYP.) PROP. 90' 2.0 4" OSCH40 PVC PIPES LEVEL 1ST 2' «: :. *6.2'± 2500 GAL 10" SEPTIC TANK/ 5.52'A...TEE PUMP CHAMBER 7 COMBINATION 0000?0000000000 0 10 - SEE DETAIL BELOW 7.67' 7.50' ( J00000000000000000000000000 ;11 •00 000 2% SLOPE) �oo (-!-% SLOPE) 1 % SLOPE) _17M 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) NOTES MARK CORNERS OF LEACHING FIELD W/ 1. DATUM IS NAVD 88 REBAR SET 4" BELOW PROVIDE INSPECTION PORTS TO GRADE WITHIN 3" OF FINISH GRADE 2. MUNICIPAL WATER IS EXISTING _ l 2% SLOPE \ FILTER FABRIC \\ 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. TOP 7.8' FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST CLEAN FILL 4• PERFORATED PVC 4' OX. S=0.005 0 0 3/4"-1-1/2" DOUBLE WASHED 0 9" STONE LEACHING FIELD 0 'La' LEVEL BOTTOM 0 WATER -TEST D'BOX FOR LEVELNESS FACTORY WATERPROOFED LEACHING FOUNDATION 34' SEPTIC TANK/ 2' D' BOX 2' FACILITY PUMP CHAMBER LOW PROFILE *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 98.4] PROPOSED SPOT EL. TH1 ROOM 1 4 TEST HOLE 8' SLOPE OF GROUND FILL UTILITY POLE V FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405 AND TOWN OF YARMOUTH HEALTH REGULATIONS: (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 11.7') (1h): REDUCTION IN GROUNDWATER SEPARATION (5' TO 4') TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNIFcc• MALLORY LANGLER DATE: 4/6/2021 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS . ELEV. ROOM 1 4 0" 8' 12» FILL KITCHEN FLOOR A PLAN LS 1OYR 5/1 24" 19" TEE BATH BEDROOM BEDROOM DINING NOT TO SCALE PROVIDE 130' OF 40 MIL ER AT 5' OFF SAS IN AREA SHOWN. TO"T ELEV. 7.8', BOTTOM AT EL. 5.3'± 45.0' ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION 6.7' 4.0' UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) T7.2' EPTH MIN BELOW INV. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. ADJUSTED GROUNDWATER 2.7' 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1"=2000'± BUOYANCY CALL: 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL 2500 H-10 TANK WEIGHT: 24,000 LBS BE REMOVED BENEATH AND 5' AROUND THE ASSESSORS MAP 25 PARCEL 339 12.0 x 6.5 x 2.98 x 62.4 = 14505 UP (OK) PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE AE AS 12. EXISTING LEACHING FACILITY SHALL BE PUMPED SHOWN ON COMMUNITY PANEL #25001CO589J AND REMOVED OR PUMPED AND FILLED WITH CLEAN DATED 7/16/2014 SAND. 13. INSTALLER TO CONFIRM SUITABILITY OF ELECTRICAL SYSTEM FOR PUMP INSTALLATION. ELECTRICAL PERMIT REQUIRED. COVERS TO GRADE 14. OWNER'S ENGINEER TO PERFORM INSPECTIONS /567 GAL, RESERVE OF THE SOIL REMOVAL, 40 MILLINER, AND FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. PROVIDE QUICK DISCONNECT FOR PUMP SUN ROOM ROOM LMNG TO BE INSTALLED INSIDE ROOM INV. IN 5.52' I SEPARATE CIRCUIT FROM PUMP KITCHEN FLOOR PLAN NOT TO SCALE PROVIDE 130' OF 40 MIL ER AT 5' OFF SAS IN AREA SHOWN. TO"T ELEV. 7.8', BOTTOM AT EL. 5.3'± 45.0' ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION 6.7' 4.0' UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) T7.2' EPTH MIN BELOW INV. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. ADJUSTED GROUNDWATER 2.7' 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1"=2000'± BUOYANCY CALL: 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL 2500 H-10 TANK WEIGHT: 24,000 LBS BE REMOVED BENEATH AND 5' AROUND THE ASSESSORS MAP 25 PARCEL 339 12.0 x 6.5 x 2.98 x 62.4 = 14505 UP (OK) PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE AE AS 12. EXISTING LEACHING FACILITY SHALL BE PUMPED SHOWN ON COMMUNITY PANEL #25001CO589J AND REMOVED OR PUMPED AND FILLED WITH CLEAN DATED 7/16/2014 SAND. 13. INSTALLER TO CONFIRM SUITABILITY OF ELECTRICAL SYSTEM FOR PUMP INSTALLATION. ELECTRICAL PERMIT REQUIRED. COVERS TO GRADE 14. OWNER'S ENGINEER TO PERFORM INSPECTIONS /567 GAL, RESERVE OF THE SOIL REMOVAL, 40 MILLINER, AND FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. PROVIDE QUICK DISCONNECT FOR PUMP NO LOW POINTS 2" PRESSURE LINE -"- SLOPE TO DRAIN BACK -0.25" WEEP HOLES CHECK VALVE MYERS SRM 4 SUBMERSIBLE 4/10 HP PUMP SYSTEM (OR EQUAL) SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 2 BEDROOMS @ 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 USE A 2500 GAL. SEPTIC TANK/ PUMP CHAMBER LEACHING: 220 GPD / (.74) = 298 SF REQUIRED 10' X 45' = 450 SF OK 450 SF X .74 = 333 GPD OK USE A 10' X 45' PIPE AND STONE LEACHING FIELD APPROVED DATE BOARD OF HEALTH SITE PLAN OF #35 BRIAR CIRCLE SOUTH YARMOUTH, MA MA =7.7' NAVD88 PREPARED FOR 5' REMOVAL OF UNSUITABLE SOIL REQUIRED n O�SO AROUND PERIMETER OF LEACHING FACILITY, T MARIE BARTH DOWN TO SUITABLE SOIL LAYER. REPLACE? C G -W ADJ. DATA:WITH CLEAN MED. SAND, TO MEET _ �8 ti�-�f' �r� W _X_x PERC SPECIFICATIONS OF 310 CMR 15.255,(-3)? X x WELL: MIW 29 J95 00 x DATE: APRIL 12, 2021 ZONE: A� s<-� REV: MAY 4, 2021 (TANK LOCATION) MS ADJ: 1.7'oFf'Avsq REV: JUNE 30, 2021 (HEALTH COMMENTS) 11 �y 9 DANIELC,S, MARCH 2021 0 A. Fye Ion caNIEL ��\ - � �^,� off 508-362-4541 D o C) O'LA. OJ ALA � CIVIL �}} fax 508-362-9880 1 0YR 7/4 I No, 40980 downcope.com No. 46,502 /STEL / Ess\ 0 down cope e'/gineel ing, ift. 01 civil engineers Scale:1 20' land surveyors GROUNDWATER ENCOUNTERED @ 84" ELEV. 1.0 "= � �3df�� -�--� 939 Main Street ( Rte 6A) BICE#21-090 0 0 20 30 4o so FEET DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 21-090 BARTH.DWG ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON INV. IN 5.52' I SEPARATE CIRCUIT FROM PUMP ZABEL FILTER - (A100) 19" TEE FLOAT SWITCH ALARM ON OUTLET TEE W/EXTEN:ION SETTINGS: PUMP ON 6 MIN. 1500 GAL. 5" WORKING RANGE _ THIS SIDE 5"OF BAFFLE 4' LIQ. LEVEL PUMP OFF 12" (ACME OR EQUAL) 000 00000 000 O ppp 000 0000 00 0000 FACTORY WATERPROOFED s" BAFFLE 2500 GAL. SEPTIC TANK/ PUMP CHAMBER COMBINATION (NOT TO SCALE) NO LOW POINTS 2" PRESSURE LINE -"- SLOPE TO DRAIN BACK -0.25" WEEP HOLES CHECK VALVE MYERS SRM 4 SUBMERSIBLE 4/10 HP PUMP SYSTEM (OR EQUAL) SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 2 BEDROOMS @ 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 USE A 2500 GAL. SEPTIC TANK/ PUMP CHAMBER LEACHING: 220 GPD / (.74) = 298 SF REQUIRED 10' X 45' = 450 SF OK 450 SF X .74 = 333 GPD OK USE A 10' X 45' PIPE AND STONE LEACHING FIELD APPROVED DATE BOARD OF HEALTH SITE PLAN OF #35 BRIAR CIRCLE SOUTH YARMOUTH, MA MA =7.7' NAVD88 PREPARED FOR 5' REMOVAL OF UNSUITABLE SOIL REQUIRED n O�SO AROUND PERIMETER OF LEACHING FACILITY, T MARIE BARTH DOWN TO SUITABLE SOIL LAYER. REPLACE? C G -W ADJ. DATA:WITH CLEAN MED. SAND, TO MEET _ �8 ti�-�f' �r� W _X_x PERC SPECIFICATIONS OF 310 CMR 15.255,(-3)? X x WELL: MIW 29 J95 00 x DATE: APRIL 12, 2021 ZONE: A� s<-� REV: MAY 4, 2021 (TANK LOCATION) MS ADJ: 1.7'oFf'Avsq REV: JUNE 30, 2021 (HEALTH COMMENTS) 11 �y 9 DANIELC,S, MARCH 2021 0 A. Fye Ion caNIEL ��\ - � �^,� off 508-362-4541 D o C) O'LA. OJ ALA � CIVIL �}} fax 508-362-9880 1 0YR 7/4 I No, 40980 downcope.com No. 46,502 /STEL / Ess\ 0 down cope e'/gineel ing, ift. 01 civil engineers Scale:1 20' land surveyors GROUNDWATER ENCOUNTERED @ 84" ELEV. 1.0 "= � �3df�� -�--� 939 Main Street ( Rte 6A) BICE#21-090 0 0 20 30 4o so FEET DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 21-090 BARTH.DWG