Loading...
Engineer Plan - 2008� � � CD/FND � ������, ^��� ���� ��cn/'�,/�//x�/m °���* IRight ror bulkhead EL.=102.25 (Assumed) y02---~----~---------`�~~_� N 79-30'20 05. | PROPOSED SEPTIC TANK 1500 GALLON CAPACITY EXISTING CESSPOOLS TO BE PUMPED, FILLED mXTH'o SAND AND ABANDONED \ � --��� EXISTING CONTOUR x l00.98 EXISTING SPOT GRADE ---[7 9D—PROPOSED CONTOUR FT-9-� PROPOSED SPOT GRADE ---yy— EXISTING WATER SERVICE -- - -- OVERHEAD VY|RE5 TEST PIT BENCHMARK X 101,71 SEWER CONNECTION |N\( = 98L42± PETE T. McEN EE C3 CIVIL 101,41 CB/FND 100,32 1AU�� � -� 100,05 100,14 in Lot 164 Mop 58 Parcel 142 100 K' f?,OAD 100M UP/771/5 \ / 100,57 LOCUS MAP NOT TO SCALE APR 0 9 2008 GENERAL NOTES: HEALTH -DEPT. 1 , ALI - CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2, ALL W�!RK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODETITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS EXCEPT AS REQUESTED BELOW: 1 THE SEWAGE DISPOSAL. SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DE( -;'ICN ENGINEER. 4ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REP6RTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. Irb=nt, ALL ELEVATIONS BASED ON ASSUMED DATUM. 6THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION WATER SUPPLY PROVIDED BY TOWN WATER SERVICE - 8, THERE ARE NO PRIVATE WELLS WITHIN 150' OF THE PROPOSED S.A.S. 9ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES, 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING 11 WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND ON ALL SIDES OF THE S,A.S, AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3), 12, AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL. PROPOSED SEPTIC SYSTEM UPGRADE PLAN 14 FRESH BROOK ROAD, SOUTH YARMOUTH, MA Prepared for: Christian Jensen, 14 Fresh Brook Rd., So. Yarmouth, MA 02664 Engineering by: Surveying by� SCALE DRAWN JOB. NO. Eng1nwdrvgWorkr WARNER SURVEYING 1 "=20' P.T.M. 129-08 12 West Crossfield Road 22 Long Rood Forestdole, MA 02644 Harwich, MA 02645 DATE CHECKED SHEET NO. PROPOSED TANK INSTALL RISERS & COVERS OVER INLET & I.U.r, OUTLET AND SET TO 6" OF FINISH GRADE -F.G. EL.=102± L - 7' @ S-1% (MIN-) 4"SCH40 'PVC F.G. EL,=102.0± PROPOSED,D—BOX INSTALL RISER & COVER SET TO 6" OF GRADE L = 7' S=l% (MIN.) 4"SCH40 PVC f 14 48* LIQUID so LEVEL GAS BAFFLE TIE IN TO EXISTING SEWER AT CESSPOOL INV.=98.42± NOTES; 1) SEPTIC TANK & D—SOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 2) INSTALL INLET & OUTLET TEES AS REQUIRED. 3) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF—TfTE, ZABEL OR EQUAL, 4) MAXIMUM COVER OVER SEPTIC TANK, D—BOX & S.A.S. SHALL BE 36". DESIGN CRITERIA NUMBER OF BEDROOMS: 2 BEDROOMS SOIL TEXTURAL CLASS- CLASS I DESIGN PERCOLATION RATE: 5 MIN/IN DAILY FLOW: 220 G.P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY LEACHING AREA REQUIRED: (330) = 445.9 S.F. ,74 F.G. EL: 101.5± L= 41 OS -17 (MIN.) 4' ,$CH40 PVC INV.=9730 TOP CONC. ELEV.=98.50 BREAKOUT ELEV.=98.20 INV. ELEV.=97.70 BOTTOM ELEV.=95.70 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. NO GROUNDWATER, EL.=90.5 SEPTIC SYSTEM PROFILE N.T.S. USE 2-50,0 QALLON LEACHING CH.ALABEES. IN SERIES SURROUNDED BY DQUaLE WASHED STONE ON ALL 5-11QUE SIDEWALL AREA: 2(13,2' + 23.0') X 2 = 144.8 S.F. BOTTOM AREA: 13.2' x 23.0' = 303.6 S.F. TOTAL AREA: ......... ...... ----- 448,4 S,F. DESIGN FLOW PROVIDED: 0,74(448.4) = 331.8 G,P.D, PROPOSED S *A,S, 1 INSTALL RISER & C6VER OVER ONE CHAMBER AND SET TO 3' OF F.G. TO SERVE AS INSPECTION PORT ,-F.G. EL: 101.5(MAX.) 2" LAYER Of 1/8" TO 1/2" DOUBLE WASHED STONE I_ 4'/ 5.2' F -/-EFFECTIVE WIDTH = 13.2' 2 X 8.5'=17.0' 3' EFFECTIVE LENGTH = 23.0' LEACHING SYSTEM SECTION NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:96.0 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. BACK OF HOUSE —44.3'---- L4 0 LA `5 P OPOS S.A S. 3.0, 149��' f DATE: MARCH 3, 2008 SOIL EVALUATOR* PETER McENTEE PE WITNESS: AMY VON HONE HEALTH AGENT ELEV, TP DEPTH 11 101.5 A L10YR 4/2OAMY SAND 101.0 LOAMY SAND 10YR 5/8 98,5 C MED, SAND 2.5Y 7/3 U 8. 36" 40" PERC 52" 90.51 138" PERC RATE <2 MIN/IN. ("C" HORIZON) NO GROUNDWATER ENCOUNTERED (3) 5" DWOUTLETS E2" 12" 6" H-10 LOADING Him 92111 F—WiUM-11 M F 51- =i 102" 500 GALLON CAPACITY, H-10 LOADING CHAMBERS N.T.S. 33 62" t PROPOSED SEPTIC SYSTEM UPGRADE PLAN 14 FRESH BROOK ROAD, SOUTH YARMOUTH, MA Prepared for: Christian Jensen, 14 Fresh Brook Rd., So. Yarmouth, MA 02664 Engineering by: Surveying by: SCALE DRAWN JOB. Na, FEnginewngwork wARNER suRwym NTS P.T.M. 129-08 12 West Crossfield Road 22 Long Road Forestdole, MA 02644 Harwich, MA 02645 DATE CHECKED SHEET NO. (508) 477-5313 (508) 432-8309 3/14/08 P.T.M. 2 of 2 4" KNOCKOUT 20" DIA. COVER 4" KNOCKOUT 4" KNOCKOUT 0 4" KNOCKOUT I I 500 GALLON CAPACITY, H-10 LOADING CHAMBERS N.T.S. 33 62" t PROPOSED SEPTIC SYSTEM UPGRADE PLAN 14 FRESH BROOK ROAD, SOUTH YARMOUTH, MA Prepared for: Christian Jensen, 14 Fresh Brook Rd., So. Yarmouth, MA 02664 Engineering by: Surveying by: SCALE DRAWN JOB. Na, FEnginewngwork wARNER suRwym NTS P.T.M. 129-08 12 West Crossfield Road 22 Long Road Forestdole, MA 02644 Harwich, MA 02645 DATE CHECKED SHEET NO. (508) 477-5313 (508) 432-8309 3/14/08 P.T.M. 2 of 2