Loading...
HomeMy WebLinkAboutcold formed metal framing shopsAccepted: Date Due: Date Issued: Date Returned: Substitution: Review Status: Project ID: Submittal No: Title: Owner: Construction Team: Design Team: Submittal Types: Trades/Disciplines: Category: Subcontractor / MFG: Yarmouth New DPW Yarmouth New DPW05/13/2020 Weston & Sampson 04/13/2020 04/13/2020 N/A Structural, Architectural Cold-Formed Metal Framing Cold-Formed Metal FramingSubmittal Dat Nguyen 05 40 00-0002-00 05 40 00-0002-00Environmental Partners GVW Inc. [(pending) Project Admin (Design) - James Barron ] [(pending) Reviewer - Kevin Connolly ] [(pending) Reviewer - Abby Cory ] [04/13/2020 Project Admin (Contractor) - Dat Nguyen ] 877-832-3206 p. clarkdietrich.com 877-832-3208 f. 20 Mansell Court East 330 Greenwood Place 383 US Route One 2262 Rutherford Road 1414 E. Field Street Suite 350B McDonough, GA 30253 Scarborough, ME 04074 Suite 104 Building C, Suite 1 Roswell, GA 30062 Carlsbad, CA 32008 Hammond, IN 46320 Page 1 of 3 ClarkDietrich Engineering Services LLC ClarkDietrich Engineering Design INC. Ref: ProSTUD® Drywall Framing Products for- Yarmouth DPW Facility At ClarkDietrich Building Systems, we continually assess our product line and modify our offering to meet the building codes and market conditions. ProSTUD® Drywall Framing combines innovative design with high strength steel to set a new industry benchmark for high performance drywall framing. The design of ProSTUD® considers the additional strength requirements of today’s building codes. Specifically, the International Building Code 2009 edition references the American Iron & Steel Institutes North American Specification for Cold-formed Steel (AISI NASPEC) 2007 Edition. The current standard no longer permits a 1/3 stress increase (0.75 load multiplier) that was permitted in previous editions of the AISI specifications. This stress increase factor is significant in composite assemblies for drywall framing. To accommodate this change, ProSTUD® is formed from steel with higher yield strengths – 50 ksi for the ProSTUD® 25 and 65 ksi for the ProSTUD 20. In addition the profile was optimized for strength with the addition of three (3) stiffening grooves in the flange, and with the double offset web. The combination of the shape and yield strength results in ProSTUD® having the highest flexural strength (bending moment) in the industry today. Life Safety is the primary concern and duty of all construction and design professionals. For interior drywall framing members, bending strength is the criteria most important to the strength of a wall stud. The American Iron and Steel Institute (AISI) defines bending or flexural strength by Ma ‐ the allowable bending moment. The Steel Framing Industry Association (SFIA) in their Code Compliance Certification Program requires that for a stud to be considered an EQ product it must have an allowable bending moment (Ma) that is equal to or greater than that for the comparable traditional drywall stud. ProSTUD® meets this requirement. ProSTUD® utilizes high strength steel in combination with advanced stud design technology to increase the strength of the stud and enable it to perform as well as or better than conventional flat steel studs of greater design thickness. ProSTUD® has three grooves on the flanges. The center one is for proper placement of abutting gypsum panels and the two other grooves are for proper location of screw placement from the edge of the gypsum panels to ensure the proper connection distance from the edge of the board to the screw. In addition, two reinforcement “planks” on the web, together with a unique diamond stamping pattern add strength to the web of the stud. March 18th 2020 Bob Harukewicz GVW Inc. Page 2 of 3 ClarkDietrich Engineering Services LLC ClarkDietrich Engineering Design INC. ProSTUD 20 DW and ProSTUD 20XD meet or exceed the performance of traditional 20 gauge studs with a design thickness of 0.0312”. In addition, ProSTUD® products, because of the higher yield strength used to manufacture the products will meet or exceed the structural capacities (Ma) of traditional flat studs. This property is typically used to compare the strength of members. Please see the table below to compare limiting heights: * In accordance with IBC 2009 **Not available with5/8” board Concerning screw pullout:  A standard, flat drywall stud with a design thickness of 0.0312” and yield strength of 33ksi has a pullout capacity of 40# for a standard #6 screw  A ProSTUD® Pro20 DW stud with a design thickness of 0.0200” and yield strength of 65 KSI has a pullout capacity of 51# for a standard #6 Screw. ProSTUD® has been 100% tested and certified. Fire testing was conducted by Underwriter Laboratories. Progressive Engineering Inc. witnessed the structural testing performed by ClarkDietrich Research LLC. Western Electro‐Acoustic Laboratories (WEAL) performed the sound testing. ProSTUD® has over 40 published sound test assemblies. ProSTUD® is a UL classified metal framing product. The UL classification indicates that UL personnel conduct unannounced quarterly inspections of our manufacturing facilities to ensure that the products delivered to you are the same products that were tested and approved. Furthermore ProSTUD® is a UL classified product with listing in over 60 UL designs including V450. With a broad range of UL designs ProSTUD® can be combined with a wide variety of gypsum board and other products. ClarkDietrich ProSTUD® framing meets ASTM C645. Based upon independent third party testing ProSTUD® has published limiting height tables. ProSTUD® is a code compliant product and as such meets the requirements of IBC 2006, IBC 2008, NYCBC 2008, etc. Limiting Height Comparison* ProSTUD™ Pro20 DW - 3-5/8” Studs vs. 3-5/8” Traditional 20 (30 mil) Gauge SSMA Steel Studs Criteria: L/240, 5 PSF 12" o.c. 16" o.c. 24" o.c. Pro20 DW Studs 1-layer 5/8" USG GWB each side 18’-7” 16’-10” 14’-9” SSMA Studs 1-layer 1/2" GWB each side** 17’-1” 15’-8” 14’-0” Limiting Height Comparison* ProSTUD™ Pro20 NS (DW) - 6” Studs vs. 6” Traditional 20 (30 mil) Gauge SSMA Steel Studs Criteria: L/240, 5 PSF 12" o.c. 16" o.c. 24" o.c. Pro20 NS (DW) Studs 1-layer 5/8" USG GWB each side 26’-5” 24’-0” 21’-0” SSMA Studs 1-layer 1/2" GWB each side** 25’-6” 23’-2” 20’-3” Page 3 of 3 ClarkDietrich Engineering Services LLC ClarkDietrich Engineering Design INC. ClarkDietrich Building Systems is the largest manufacturer in the U.S. for Metal Stud Products. Adherence to ASTM standards, Federal Specification, and over-all quality are the foundation for our success. ClarkDietrich Building Systems is a member of AISI, AWCI, ASTM, CFSEI and SFIA. If there is any way we can be of further assistance please do not hesitate to call. Sincerely, Teresa Conner Engineering Technical Service – Eastern U.S. ClarkDietrich Engineering Services LLC ClarkDietrich Building Systems Toll Free: 888.437.3244 Accepted: Date Due: Date Issued: Date Returned: Substitution: Review Status: Project ID: Submittal No: Title: Owner: Construction Team: Design Team: Submittal Types: Trades/Disciplines: Category: Subcontractor / MFG: Yarmouth New DPW Yarmouth New DPW05/13/2020 Weston & Sampson 04/13/2020 04/13/2020 N/A Structural, Architectural Cold-Formed Metal Framing Cold-Formed Metal FramingSubmittal Dat Nguyen 05 40 00-0002-00 05 40 00-0002-00Environmental Partners GVW Inc. [(pending) Project Admin (Design) - James Barron ] [(pending) Reviewer - Kevin Connolly ] [(pending) Reviewer - Abby Cory ] [04/13/2020 Project Admin (Contractor) - Dat Nguyen ] STRONGER THAN STEELSM. ProSTUD® product catalog DRYWALL FRAMING SYSTEM WHERE INNOVATION TAKES FORM. ClarkDietrich. ProSTUD® DRYWALL FRAMING SYSTEM TABLE OF CONTENTS ProSTUD Drywall Framing System Table of Contents 3 Overview 4 Profile Information 5 Physical & Structural Properties ProSTUD 25 (15mil) 6 ProSTUD 20 (18 mil) 7 ProSTUD 20 LTD (19mil) 8 ProSTUD 30MIL 9 ProSTUD 33MIL 10 Connections Allowable Screw Design Values 11 Limiting Heights Overview 12 Composite Limiting Heights Tables 13–14 Non-Composite Limiting Heights Tables Fully Braced 15 Braced at 48" o.c. 16 Sound Testing Sound Assemblies 17–18 Fire Testing UL® Listed Wall Assemblies 19 Connections Deflection Track Systems 20 Ceiling Span Tables 21 General LEED® Information 22 Support Tools 23 Code Compliance and Certification 24 The ProSTUD® Drywall Framing System can be called many things. Strong. Versatile. Fast. And without a doubt—revolutionary. But one of the biggest benefits to keep in mind is this: ProSTUD was developed, tested and approved by pros in the field who demanded nothing less than achieving absolute ease of use. Its performance has also been proven by the most extensive laboratory evaluations available. All of which means ProSTUD comes with complete confidence and no questions about code compliance. With the backing of online, mobile and data-rich BIM resources, there’s no better example of a broader vision at work. ProSTUD, in fact, is just one example of how ClarkDietrich can reinforce your efforts to design and build more intelligently. Yes, we’re known as a manufacturer of extensively tested, code-compliant steel framing products, but we offer so much more. Our products perform as a system. We support a range of efforts for smarter installation and design. We provide the expertise of a versatile engineering services team. And we do it all on a nationwide scale. We’ve put together an incredible array of resources to help you be successful on any project, regardless of size or complexity. Within this catalog you’ll discover the multiple advantages ProSTUD has to offer, as well as detailed information on the product lineup, limiting heights, sound and fire assemblies, and more. Ultimately, your choice of ProSTUD doesn’t come down to the integrity of the product alone, or even its ease of use. You’re also looking to the strength of the company that stands behind it. Count on the expertise, services and full support of ClarkDietrich today—and far into the future. Need Product Submittals? Use SubmittalPro® at clarkdietrich.com. 3 The technical content of this literature is effective 6/25/18 and supersedes all previous information.Pub. No. CD-ProSTUD 6/18 clarkdietrich.com Allowable Bending Capacity, 3-5/8" Stud OVERVIEW Gauge equivalent drywall framing must meet the minimum performance requirements of conventional drywall framing as defined by the Steel Framing Industry Association (SFIA) and the Steel Stud Manufacturers Association (SSMA). The industry’s “EQ” product of choice, ProSTUD,® employs roll-forming and steel-making technology, exceeding the performance of conventional drywall framing for allowable moment and screw connection strength. When comparing drywall framing systems, it is important to keep in mind Life Safety, System Performance and Connections. The ProSTUD Drywall Framing System provides peace of mind for all three important functions by providing the right selection of products and product data for every application. Connections In addition to sufficient member strength, it’s important to know how connections will perform. Connections can be critical to the capacity and safety of an assembly, but they are also important for the attachment of cabinets, shelving, handrails, and other accessories to steel framing. The tables below compare the screw performance of ProSTUD to conventional drywall framing. This performance relationship to conventional studs can be applied to a variety of fasteners and connections. Along with connection capacity, conventional framing members are required to meet performance criteria for screw spinout. ProSTUD was developed with screw performance in mind. High-strength steel, flange stiffening grooves, web embossments, and knurling features combine to provide the best performance per thickness, exceeding the requirements of ASTM C645. Life Safety Life Safety is the primary concern and duty of all construction and design professionals. For interior drywall framing members, bending strength is the criteria most important to the strength of a wall or ceiling. AISI defines bending or flexural strength by Allowable Moment. The corresponding chart compares the bending strength of ProSTUD and conventional drywall studs. System Performance Given ProSTUD’s strength and versatility, it’s important to know the performance of the ProSTUD member under your project’s specific criteria. This catalog will provide guidance in a variety of assemblies and loading criteria, based on current building codes. Additional data is available at clarkdietrich.com.Allowable Moment (Ma, in-k)ProSTUD 25ProSTUD 2025 Gauge20 Gauge (Drywall)4 3 2 1.69 3.10 1.48 3.08 1 0 WHAT IS AN EQUIVALENT (EQ) DRYWALL STUD? Comparison of ProSTUD Drywall Framing to Conventional Drywall Framing #6 Screw Shear (Bearing) Values Allowable Shear (lbs)ProSTUD 250 60 90 120 30 31 #6 Screw Pullout Values Allowable Pullout (lbs)ProSTUD 25ProSTUD 2025 Gauge60 0 45 30 15 20 Gauge (Drywall)ProSTUD Drywall Framing Conventional Drywall Framing ProSTUD 25 15mil 25 Gauge 18mil ProSTUD 20 18mil 20 Gauge 30mil 24 52 40 52 25 Gauge95 44 95 ProSTUD 2020 Gauge (Drywall)4 The technical content of this literature is effective 6/25/18 and supersedes all previous information.The technical content of this literature is effective 6/25/18 and supersedes all previous information. Pub. No. CD-ProSTUD 6/18clarkdietrich.com • Web Widths: 1-5/8," 2-1/2," 3-1/2," 3-5/8," 4," 5-1/2," and 6" • Flange: 1-1/4" • Return Lip: varies by stud size • Material Thicknesses: ProSTUD 25 / 15mil (25ga EQ) 50ksi ProSTUD 20 / 18mil (20ga EQ) 70ksi ProSTUD 30MIL 33ksi ProSTUD 33MIL 33ksi • Available G40EQ, G40 (CP60 available as special order) • G40EQ DiamondPlus™ available for 15mil, 18mil & 19mil only. • ProSTUD 20 LTD / 19mil (65ksi) Available for limited time. Contact your ClarkDietrich Sales Representative for market availability. • Web Widths: 1-5/8," 2-1/2," 3-1/2," 3-5/8," 4," 5-1/2," and 6" • Legs: 1," 1-1/4," 1-1/2," 2," 2-1/2," and 3" • Material Thicknesses: ProTRAK 25 / 15mil (25ga EQ) 50ksi ProTRAK 20 / 18mil (20ga EQ) 50ksi ProTRAK 30MIL 33ksi ProTRAK 33MIL 33ksi • Available G40EQ, G40 (CP60 available as special order) • G40EQ DiamondPlus™ available for 15mil, 18mil & 19mil only. • ProTRAK 20 LTD / 19mil (65ksi) Available for limited time. Contact your ClarkDietrich Sales Representative for market availability. ProSTUD Profile Double offset web planking Diamond- embossed web* Return lips vary depending on stud size Low-profile flange stiffening grooves Drywall Joint Flange grooves spaced at 3/8" o.c. 3/8" Minimum edge distance Double offset in web prevents flange locking of studs Shipping / Stacking PROFILE INFORMATION ProSTUD® ProTRAK CONSTRUCTION ADVANTAGES DESIGN ADVANTAGES *Except in 1-5/8" Can contribute LEED® points in LEED v4 or LEED 2009. EPD and HPD verifications also available• Designed to meet the additional strength requirements of today's building codes: IBC 2015, AISI NASPEC (S100), ICC-ES AC86 (2015) • National availability• 5 The technical content of this literature is effective 6/25/18 and supersedes all previous information.Pub. No. CD-ProSTUD 6/18 clarkdietrich.com PHYSICAL AND STRUCTURAL PROPERTIES ClarkDietrich ProTRAK 25 (15mil) physical and structural properties Member Design thickness (in) Fy (ksi) Gross Section Properties Effective Section Properties at Fy Torsional Properties Area(in2)Weight(lb/ft)Ix(in4)Rx(in)Iy(in4)Ry(in)Ae(in2)Ix(in4)Sx(in3)Ma(in-lbs)Vag(lb)Jx1000(in4)Cw(in6)Xo(in)Ro(in)βBeta 162PDT125-15 0.0158 50 0.065 0.22 0.034 0.717 0.011 0.412 0.020 0.021 0.016 464 222 0.00542 0.006 -0.881 1.208 0.468 250PDT125-15 0.0158 50 0.079 0.27 0.085 1.038 0.013 0.400 0.020 0.059 0.024 724 143 0.00657 0.015 -0.771 1.353 0.675 362PDT125-151 0.0158 50 0.097 0.33 0.196 1.425 0.014 0.381 0.021 0.125 0.035 1059 98 0.00805 0.034 -0.668 1.619 0.830 400PDT125-151 0.0158 50 0.103 0.35 0.247 1.550 0.014 0.374 0.021 0.153 0.039 1171 89 0.00854 0.043 -0.640 1.718 0.861 600PDT125-152 0.0158 50 0.134 0.46 0.646 2.194 0.016 0.343 0.021 0.350 0.059 1762 59 0.01117 0.108 -0.524 2.282 0.947 162PDT200-15 0.0158 50 0.089 0.30 0.050 0.752 0.039 0.663 0.020 0.025 0.015 455 222 0.00739 0.020 -1.579 1.870 0.287 250PDT200-15 0.0158 50 0.103 0.35 0.124 1.098 0.045 0.662 0.021 0.064 0.024 720 143 0.00854 0.052 -1.431 1.921 0.445 362PDT200-151 0.0158 50 0.120 0.41 0.277 1.516 0.051 0.648 0.021 0.137 0.036 1063 98 0.01002 0.120 -1.282 2.088 0.623 400PDT200-151 0.0158 50 0.126 0.43 0.344 1.650 0.052 0.642 0.021 0.168 0.039 1178 89 0.01052 0.151 -1.240 2.162 0.671 600PDT200-152 0.0158 50 0.158 0.54 0.864 2.338 0.058 0.608 0.021 0.389 0.060 1789 59 0.01315 0.383 -1.058 2.638 0.839 162PDT250-15 0.0158 50 0.105 0.36 0.061 0.766 0.071 0.824 0.020 0.027 0.015 455 222 0.00871 0.038 -2.058 2.345 0.230 250PDT250-15 0.0158 50 0.118 0.40 0.150 1.123 0.082 0.831 0.021 0.066 0.024 725 143 0.00986 0.096 -1.892 2.352 0.353 362PDT250-151 0.0158 50 0.136 0.46 0.330 1.557 0.092 0.823 0.021 0.142 0.036 1073 98 0.01134 0.220 -1.720 2.462 0.512 400PDT250-151 0.0158 50 0.142 0.48 0.409 1.696 0.095 0.819 0.021 0.174 0.040 1189 89 0.01183 0.275 -1.670 2.517 0.560 600PDT250-152 0.0158 50 0.174 0.59 1.009 2.409 0.108 0.787 0.021 0.404 0.060 1809 59 0.01446 0.697 -1.452 2.921 0.753 Notes: – Calculated properties are based on AISI S100-12, North American Specification for Design of Cold-Formed Steel Structural Members and AISI S220-15, North American Standard for Cold-Formed Steel Framing—Nonstructural Members. – Effective properties incorporate the strength increase from the cold work of forming as applicable per AISI A7.2. – Tabulated gross properties, including torsional properties, are based on full-unreduced cross section of the studs, away from punchouts. – Tabulated gross properties, including torsional properties, are based on full-unreduced cross section of the tracks. – For deflection calculations, use the effective moment of inertia. – Allowable moment includes cold work of forming. – Allowable moment is taken as the lowest value based on local or distortional buckling. Distortional buckling strength is based on a k-phi = 0. – Web depth for track sections is equal to the nominal height plus two times the design thickness plus the bend radius. Hems on nonstructural track sections are ignored. 1 Web-height to thickness ratio exceeds 200. 2 Web-height to thickness ratio exceeds 260. ProTRAK® 25 (15MIL) DRYWALL TRACK ClarkDietrich ProSTUD 25 (15mil) physical and structural properties Member Design thickness (in) Fy (ksi) Gross Section Properties Effective Section Properties at Fy Torsional Properties Lu (in)Area(in2)Weight(lb/ft)Ix(in4)Rx(in)Iy(in4)Ry(in)Ae(in2)Ix(in4)Sx(in3)Ma(in-lbs)Vag(lb)Vanet(lb)Jx1000(in4)Cw(in6)Xo(in)Ro(in)βBeta 162PDS125-15 0.0158 50 0.071 0.24 0.033 0.688 0.015 0.466 0.033 0.030 0.024 719 232 104 0.00589 0.009 -1.088 1.369 0.368 24.8 250PDS125-15 0.0158 50 0.085 0.29 0.088 1.020 0.018 0.459 0.033 0.080 0.044 1198 147 141 0.00704 0.023 -0.959 1.473 0.576 24.5 362PDS125-151 0.0158 50 0.102 0.35 0.206 1.420 0.020 0.442 0.034 0.190 0.056 1689 100 100 0.00852 0.051 -0.837 1.706 0.760 24.3 400PDS125-151 0.0158 50 0.108 0.37 0.260 1.549 0.021 0.436 0.034 0.233 0.062 1870 90 90 0.00901 0.064 -0.803 1.798 0.800 24.2 600PDS125-152 0.0158 50 0.140 0.48 0.683 2.209 0.023 0.404 0.034 0.537 0.105 2781 60 60 0.01164 0.161 -0.666 2.343 0.919 23.6 ProSTUD® 25 (15MIL) DRYWALL STUD 6 The technical content of this literature is effective 6/25/18 and supersedes all previous information.The technical content of this literature is effective 6/25/18 and supersedes all previous information. Pub. No. CD-ProSTUD 6/18clarkdietrich.com PHYSICAL AND STRUCTURAL PROPERTIES ClarkDietrich ProSTUD 20 (18mil) physical and structural properties ClarkDietrich ProTRAK 20 (18mil) physical and structural properties Notes: – Calculated properties are based on AISI S100-12, North American Specification for Design of Cold-Formed Steel Structural Members and AISI S220-15, North American Standard for Cold-Formed Steel Framing—Nonstructural Members. – Effective properties incorporate the strength increase from the cold work of forming as applicable per AISI A7.2. – Tabulated gross properties, including torsional properties, are based on full-unreduced cross section of the studs, away from punchouts. – Tabulated gross properties, including torsional properties, are based on full-unreduced cross section of the tracks. – For deflection calculations, use the effective moment of inertia. – Allowable moment includes cold work of forming. – Allowable moment is taken as the lowest value based on local or distortional buckling. Distortional buckling strength is based on a k-phi = 0. – Web depth for track sections is equal to the nominal height plus two times the design thickness plus the bend radius. Hems on nonstructural track sections are ignored. 1 Web-height to thickness ratio exceeds 200. 2 Web-height to thickness ratio exceeds 260. Member Design thickness (in) Fy (ksi) Gross Section Properties Effective Section Properties at Fy Torsional Properties Area(in2)Weight(lb/ft)Ix(in4)Rx(in)Iy(in4)Ry(in)Ae(in2)Ix(in4)Sx(in3)Ma(in-lbs)Vag(lb)Jx1000(in4)Cw(in6)Xo(in)Ro(in)βBeta 162PDT125-18 0.0190 50 0.078 0.27 0.040 0.718 0.013 0.411 0.028 0.027 0.022 663 380 0.00943 0.007 -0.879 1.207 0.470 250PDT125-18 0.0190 50 0.095 0.32 0.102 1.038 0.015 0.400 0.029 0.073 0.034 1029 248 0.01143 0.017 -0.770 1.353 0.676 362PDT125-18 0.0190 50 0.116 0.40 0.236 1.426 0.017 0.380 0.029 0.173 0.050 1497 170 0.01400 0.041 -0.666 1.619 0.831 400PDT125-18 0.0190 50 0.123 0.42 0.297 1.550 0.017 0.374 0.029 0.211 0.055 1653 154 0.01486 0.051 -0.638 1.718 0.862 600PDT125-182 0.0190 50 0.161 0.55 0.778 2.195 0.019 0.342 0.029 0.469 0.083 2473 102 0.01943 0.130 -0.523 2.282 0.947 162PDT200-18 0.0190 50 0.107 0.36 0.061 0.753 0.047 0.662 0.028 0.032 0.021 642 380 0.01285 0.024 -1.577 1.869 0.288 250PDT200-18 0.0190 50 0.123 0.42 0.149 1.099 0.054 0.661 0.029 0.088 0.034 1016 248 0.01486 0.063 -1.429 1.920 0.446 362PDT200-18 0.0190 50 0.145 0.49 0.333 1.517 0.061 0.648 0.029 0.188 0.050 1500 170 0.01743 0.145 -1.280 2.088 0.624 400PDT200-18 0.0190 50 0.152 0.52 0.414 1.651 0.063 0.642 0.029 0.230 0.055 1661 154 0.01828 0.181 -1.238 2.161 0.672 600PDT200-182 0.0190 50 0.190 0.65 1.039 2.339 0.070 0.607 0.030 0.532 0.084 2525 102 0.02286 0.461 -1.057 2.637 0.840 162PDT250-18 0.0190 50 0.126 0.43 0.074 0.767 0.085 0.823 0.028 0.035 0.021 635 380 0.01514 0.045 -2.056 2.344 0.231 250PDT250-18 0.0190 50 0.142 0.48 0.180 1.125 0.098 0.830 0.029 0.091 0.034 1011 248 0.01714 0.115 -1.891 2.351 0.353 362PDT250-18 0.0190 50 0.164 0.56 0.398 1.558 0.111 0.823 0.029 0.195 0.050 1498 170 0.01971 0.264 -1.718 2.461 0.512 400PDT250-18 0.0190 50 0.171 0.58 0.492 1.697 0.114 0.818 0.029 0.239 0.055 1661 154 0.02057 0.331 -1.669 2.517 0.560 600PDT250-182 0.0190 50 0.209 0.71 1.214 2.410 0.129 0.786 0.030 0.555 0.085 2533 102 0.02514 0.838 -1.450 2.920 0.753 ProTRAK® 20 (18MIL) DRYWALL TRACK Member Design thickness (in) Fy (ksi) Gross Section Properties Effective Section Properties at Fy Torsional Properties Lu (in)Area(in2)Weight(lb/ft)Ix(in4)Rx(in)Iy(in4)Ry(in)Ae(in2)Ix(in4)Sx(in3)Ma(in-lbs)Vag(lb)Vanet(lb)Jx1000(in4)Cw(in6)Xo(in)Ro(in)βBeta 162PDS125-18 0.0190 70 0.086 0.29 0.040 0.685 0.019 0.468 0.039 0.035 0.028 1194 405 149 0.01032 0.012 -1.105 1.382 0.361 24.8 250PDS125-18 0.0190 70 0.104 0.35 0.107 1.017 0.023 0.470 0.043 0.099 0.056 2361 256 204 0.01250 0.031 -1.004 1.504 0.555 24.5 362PDS125-18 0.0190 70 0.126 0.43 0.254 1.421 0.026 0.456 0.044 0.234 0.074 3102 174 170 0.01512 0.070 -0.884 1.734 0.740 24.3 400PDS125-181 0.0190 70 0.133 0.45 0.321 1.551 0.027 0.453 0.046 0.286 0.084 3532 157 157 0.01605 0.089 -0.859 1.830 0.780 24.2 600PDS125-182 0.0190 70 0.173 0.59 0.855 2.223 0.032 0.431 0.046 0.669 0.141 5891 104 104 0.02083 0.233 -0.739 2.382 0.904 23.6 ProSTUD® 20 (18MIL) DRYWALL STUD 7 The technical content of this literature is effective 6/25/18 and supersedes all previous information.Pub. No. CD-ProSTUD 6/18 clarkdietrich.com ClarkDietrich ProSTUD 20 LTD (19mil) physical and structural properties ClarkDietrich ProTRAK 20 LTD (19mil) physical and structural properties Notes: – Calculated properties are based on AISI S100-12, North American Specification for Design of Cold-Formed Steel Structural Members and AISI S220-15, North American Standard for Cold-Formed Steel Framing—Nonstructural Members. – Effective properties incorporate the strength increase from the cold work of forming as applicable per AISI A7.2. – Tabulated gross properties, including torsional properties, are based on full-unreduced cross section of the studs, away from punchouts. – Tabulated gross properties, including torsional properties, are based on full-unreduced cross section of the tracks. – For deflection calculations, use the effective moment of inertia. – Allowable moment includes cold work of forming. – Allowable moment is taken as the lowest value based on local or distortional buckling. Distortional buckling strength is based on a k-phi = 0. – Web depth for track sections is equal to the nominal height plus two times the design thickness plus the bend radius. Hems on nonstructural track sections are ignored. 1 Web-height to thickness ratio exceeds 200. 2 Web-height to thickness ratio exceeds 260. Member Design thickness (in) Fy (ksi) Gross Section Properties Effective Section Properties at Fy Torsional Properties Area(in2)Weight(lb/ft)Ix(in4)Rx(in)Iy(in4)Ry(in)Ae(in2)Ix(in4)Sx(in3)Ma(in-lbs)Vag(lb)Jx1000(in4)Cw(in6)Xo(in)Ro(in)βBeta 162PDT125-19 0.0200 50 0.082 0.28 0.043 0.719 0.014 0.411 0.031 0.028 0.024 718 421 0.01099 0.007 -0.879 1.207 0.470 250PDT125-19 0.0200 50 0.100 0.34 0.108 1.039 0.016 0.400 0.032 0.078 0.038 1136 289 0.01333 0.018 -0.769 1.353 0.677 362PDT125-19 0.0200 50 0.122 0.42 0.249 1.426 0.018 0.380 0.032 0.191 0.055 1650 199 0.01633 0.043 -0.666 1.619 0.831 400PDT125-19 0.0200 50 0.130 0.44 0.312 1.551 0.018 0.374 0.032 0.232 0.061 1822 180 0.01733 0.054 -0.638 1.718 0.862 600PDT125-192 0.0200 50 0.170 0.58 0.819 2.195 0.020 0.342 0.032 0.508 0.091 2717 119 0.02266 0.137 -0.523 2.282 0.948 162PDT200-19 0.0200 50 0.112 0.38 0.064 0.754 0.049 0.662 0.031 0.034 0.024 707 421 0.01499 0.026 -1.576 1.868 0.288 250PDT200-19 0.0200 50 0.130 0.44 0.157 1.099 0.057 0.661 0.032 0.094 0.037 1119 289 0.01733 0.066 -1.429 1.920 0.446 362PDT200-19 0.0200 50 0.152 0.52 0.351 1.517 0.064 0.647 0.032 0.205 0.055 1651 199 0.02033 0.152 -1.280 2.088 0.624 400PDT200-19 0.0200 50 0.160 0.54 0.436 1.651 0.066 0.642 0.032 0.251 0.061 1829 180 0.02133 0.191 -1.238 2.161 0.672 600PDT200-192 0.0200 50 0.200 0.68 1.094 2.339 0.074 0.607 0.033 0.580 0.093 2780 119 0.02666 0.485 -1.056 2.637 0.840 162PDT250-19 0.0200 50 0.132 0.45 0.078 0.768 0.090 0.823 0.031 0.037 0.023 698 421 0.01766 0.048 -2.055 2.343 0.231 250PDT250-19 0.0200 50 0.150 0.51 0.190 1.125 0.103 0.830 0.032 0.099 0.037 1113 289 0.01999 0.121 -1.890 2.351 0.354 362PDT250-19 0.0200 50 0.172 0.59 0.419 1.558 0.117 0.822 0.032 0.213 0.055 1649 199 0.02299 0.278 -1.718 2.461 0.513 400PDT250-19 0.0200 50 0.180 0.61 0.518 1.697 0.120 0.818 0.032 0.261 0.061 1829 180 0.02399 0.348 -1.668 2.517 0.561 600PDT250-192 0.0200 50 0.220 0.75 1.278 2.410 0.136 0.786 0.033 0.605 0.093 2788 119 0.02933 0.881 -1.450 2.920 0.754 ProTRAK® 20 LTD (19MIL) DRYWALL TRACK Member Design thickness (in) Fy (ksi) Gross Section Properties Effective Section Properties at Fy Torsional Properties Lu (in)Area(in2)Weight(lb/ft)Ix(in4)Rx(in)Iy(in4)Ry(in)Ae(in2)Ix(in4)Sx(in3)Ma(in-lbs)Vag(lb)Vanet(lb)Jx1000(in4)Cw(in6)Xo(in)Ro(in)βBeta 162PDS125-19 0.0200 65 0.090 0.31 0.042 0.685 0.020 0.466 0.042 0.037 0.031 1193 473 165 0.01197 0.012 -1.096 1.374 0.364 22.0 250PDS125-19 0.0200 65 0.109 0.37 0.112 1.017 0.024 0.467 0.046 0.104 0.061 2110 299 226 0.01449 0.032 -0.992 1.495 0.560 22.2 362PDS125-19 0.0200 65 0.132 0.45 0.266 1.420 0.027 0.454 0.048 0.254 0.080 3103 203 189 0.01757 0.072 -0.876 1.729 0.743 22.1 400PDS125-19 0.0200 65 0.140 0.48 0.336 1.550 0.028 0.451 0.050 0.316 0.091 3537 184 184 0.01865 0.092 -0.851 1.825 0.783 22.2 600PDS125-192 0.0200 65 0.181 0.62 0.892 2.220 0.033 0.425 0.051 0.727 0.158 5421 121 121 0.02414 0.236 -0.723 2.373 0.907 21.9 ProSTUD® 20 LTD (19MIL) DRYWALL STUD ProSTUD 20 LTD / 19mil (65ksi) and ProTRAK 20 LTD / 19mil (65ksi) available for limited time.Contact your ClarkDietrich sales representative for market availability. 8 The technical content of this literature is effective 6/25/18 and supersedes all previous information.The technical content of this literature is effective 6/25/18 and supersedes all previous information. Pub. No. CD-ProSTUD 6/18clarkdietrich.com PHYSICAL AND STRUCTURAL PROPERTIES ClarkDietrich ProSTUD 30MIL physical and structural properties ClarkDietrich ProTRAK 30MIL physical and structural properties Member Design thickness (in) Fy (ksi) Gross Section Properties Effective Section Properties at Fy Torsional Properties Area(in2)Weight(lb/ft)Ix(in4)Rx(in)Iy(in4)Ry(in)Ae(in2)Ix(in4)Sx(in3)Ma(in-lbs)Vag(lb)J* 1000(in4)Cw(in6)Xo(in)Ro(in)β Beta 162PDT125-30 0.0312 33 0.128 0.44 0.067 0.722 0.022 0.409 0.080 0.054 0.048 951 610 0.04168 0.011 -0.872 1.204 0.475 250PDT125-30 0.0312 33 0.156 0.53 0.169 1.042 0.025 0.397 0.084 0.140 0.087 1713 832 0.05054 0.029 -0.763 1.351 0.681 362PDT125-30 0.0312 33 0.191 0.65 0.389 1.428 0.027 0.378 0.087 0.330 0.149 2938 755 0.06193 0.067 -0.661 1.619 0.833 400PDT125-30 0.0312 33 0.203 0.69 0.489 1.553 0.028 0.371 0.088 0.417 0.172 3407 683 0.06573 0.084 -0.633 1.718 0.864 600PDT125-30 0.0312 33 0.265 0.90 1.278 2.196 0.031 0.340 0.090 1.074 0.240 4737 454 0.08597 0.212 -0.519 2.282 0.948 162PDT200-30 0.0312 33 0.175 0.60 0.101 0.758 0.076 0.660 0.081 0.067 0.052 1028 610 0.05687 0.040 -1.570 1.864 0.291 250PDT200-30 0.0312 33 0.203 0.69 0.246 1.103 0.088 0.659 0.086 0.170 0.094 1862 832 0.06573 0.103 -1.423 1.917 0.449 362PDT200-30 0.0312 33 0.238 0.81 0.549 1.520 0.099 0.645 0.089 0.397 0.160 3159 755 0.07712 0.237 -1.274 2.086 0.627 400PDT200-30 0.0312 33 0.249 0.85 0.682 1.654 0.102 0.639 0.089 0.502 0.176 3480 683 0.08091 0.297 -1.232 2.160 0.674 600PDT200-30 0.0312 33 0.312 1.06 1.710 2.342 0.114 0.605 0.091 1.353 0.262 5170 454 0.10116 0.754 -1.051 2.637 0.841 162PDT250-30 0.0312 33 0.206 0.70 0.123 0.772 0.139 0.821 0.082 0.073 0.054 1059 610 0.06699 0.075 -2.048 2.338 0.233 250PDT250-30 0.0312 33 0.234 0.80 0.298 1.129 0.160 0.828 0.086 0.186 0.097 1926 832 0.07585 0.190 -1.883 2.347 0.356 362PDT250-30 0.0312 33 0.269 0.92 0.656 1.562 0.181 0.820 0.089 0.436 0.157 3097 755 0.08724 0.435 -1.712 2.458 0.515 400PDT250-30 0.0312 33 0.281 0.96 0.812 1.701 0.187 0.816 0.090 0.551 0.173 3425 683 0.09104 0.543 -1.662 2.514 0.563 600PDT250-30 0.0312 33 0.343 1.17 1.997 2.413 0.211 0.784 0.092 1.473 0.261 5162 454 0.11128 1.373 -1.444 2.919 0.755 Member Design thickness (in) Fy (ksi) Gross Section Properties Effective Section Properties at Fy Torsional Properties Lu (in)Area(in2)Weight(lb/ft)Ix(in4)Rx(in)Iy(in4)Ry(in)Ae(in2)Ix(in4)Sx(in3)Ma(in-lbs)Vag(lb)Vanet(lb)J* 1000(in4)Cw(in6)Xo(in)Ro(in)βBeta 162PDS125-30 0.0312 33 0.137 0.47 0.064 0.681 0.029 0.458 0.098 0.064 0.067 1332 572 124 0.04459 0.017 -1.070 1.348 0.371 30.8 250PDS125-30 0.0312 33 0.165 0.56 0.169 1.012 0.034 0.451 0.106 0.168 0.121 2356 832 397 0.05345 0.042 -0.941 1.454 0.581 30.1 362PDS125-30 0.0312 33 0.200 0.68 0.398 1.411 0.038 0.434 0.107 0.396 0.170 3358 776 457 0.06484 0.096 -0.820 1.689 0.764 29.7 400PDS125-30 0.0312 33 0.212 0.72 0.501 1.540 0.039 0.428 0.108 0.499 0.189 3737 701 490 0.06864 0.120 -0.787 1.781 0.805 29.5 600PDS125-30 0.0312 33 0.274 0.93 1.324 2.199 0.043 0.396 0.109 1.281 0.338 6031 461 461 0.08888 0.303 -0.651 2.327 0.922 28.7 Notes: – Calculated properties are based on AISI S100-12, North American Specification for Design of Cold-Formed Steel Structural Members and AISI S220-15, North American Standard for Cold-Formed Steel Framing—Nonstructural Members. – Effective properties incorporate the strength increase from the cold work of forming as applicable per AISI A7.2. – Tabulated gross properties, including torsional properties, are based on full-unreduced cross section of the studs, away from punchouts. – Tabulated gross properties, including torsional properties, are based on full-unreduced cross section of the tracks. – For deflection calculations, use the effective moment of inertia. – Allowable moment includes cold work of forming. – Allowable moment is taken as the lowest value based on local or distortional buckling. Distortional buckling strength is based on a k-phi = 0. – Web depth for track sections is equal to the nominal height plus two times the design thickness plus the bend radius. Hems on nonstructural track sections are ignored. 1 Web-height to thickness ratio exceeds 200. 2 Web-height to thickness ratio exceeds 260. ProSTUD® 30MIL DRYWALL STUD (AVAILABLE IN SELECT MARKETS) ProTRAK® 30MIL DRYWALL TRACK ClarkDietrich ProSTUD 20 LTD (19mil) physical and structural properties 9 The technical content of this literature is effective 6/25/18 and supersedes all previous information.Pub. No. CD-ProSTUD 6/18 clarkdietrich.com ClarkDietrich ProSTUD 33MIL physical and structural properties ClarkDietrich ProTRAK 33MIL physical and structural properties Member Design thickness (in) Fy (ksi) Gross Section Properties Effective Section Properties at Fy Torsional Properties Area(in2)Weight(lb/ft)Ix(in4)Rx(in)Iy(in4)Ry(in)Ae(in2)Ix(in4)Sx(in3)Ma(in-lbs)Vag(lb)J* 1000(in4)Cw(in6)Xo(in)Ro(in)β Beta 162PDT125-33 0.0346 33 0.142 0.48 0.075 0.723 0.024 0.409 0.095 0.063 0.056 1104 677 0.05683 0.012 -0.870 1.203 0.477 250PDT125-33 0.0346 33 0.173 0.59 0.188 1.043 0.027 0.397 0.102 0.160 0.100 1972 1024 0.06891 0.032 -0.762 1.351 0.682 362PDT125-33 0.0346 33 0.212 0.72 0.432 1.429 0.030 0.377 0.105 0.375 0.170 3358 1024 0.08444 0.074 -0.659 1.618 0.834 400PDT125-33 0.0346 33 0.225 0.77 0.542 1.554 0.031 0.371 0.106 0.473 0.197 3887 931 0.08962 0.093 -0.632 1.718 0.865 600PDT125-33 0.0346 33 0.294 1.00 1.418 2.197 0.034 0.339 0.109 1.237 0.287 5681 619 0.11723 0.234 -0.517 2.282 0.949 162PDT200-33 0.0346 33 0.194 0.66 0.112 0.759 0.085 0.660 0.097 0.077 0.061 1198 677 0.07754 0.045 -1.568 1.862 0.292 250PDT200-33 0.0346 33 0.225 0.77 0.274 1.104 0.097 0.658 0.104 0.196 0.109 2150 1024 0.08962 0.114 -1.421 1.916 0.450 362PDT200-33 0.0346 33 0.264 0.90 0.610 1.521 0.110 0.645 0.107 0.452 0.186 3669 1024 0.10515 0.263 -1.272 2.085 0.628 400PDT200-33 0.0346 33 0.276 0.94 0.758 1.655 0.113 0.639 0.108 0.567 0.215 4246 931 0.11033 0.329 -1.230 2.159 0.675 600PDT200-33 0.0346 33 0.346 1.18 1.897 2.342 0.126 0.604 0.111 1.520 0.322 6355 619 0.13795 0.835 -1.050 2.637 0.842 162PDT250-33 0.0346 33 0.229 0.78 0.137 0.774 0.154 0.821 0.098 0.085 0.063 1235 677 0.09135 0.083 -2.046 2.336 0.233 250PDT250-33 0.0346 33 0.259 0.88 0.331 1.130 0.177 0.827 0.104 0.214 0.113 2225 1024 0.10343 0.211 -1.881 2.346 0.357 362PDT250-33 0.0346 33 0.298 1.01 0.728 1.563 0.200 0.820 0.108 0.493 0.193 3808 1024 0.11896 0.482 -1.710 2.457 0.516 400PDT250-33 0.0346 33 0.311 1.06 0.901 1.702 0.207 0.815 0.109 0.622 0.214 4221 931 0.12414 0.602 -1.660 2.514 0.564 600PDT250-33 0.0346 33 0.380 1.29 2.216 2.414 0.233 0.783 0.111 1.657 0.320 6327 619 0.15175 1.522 -1.443 2.919 0.756 Member Design thickness (in) Fy (ksi) Gross Section Properties Effective Section Properties at Fy Torsional Properties Lu (in)Area(in2)Weight(lb/ft)Ix(in4)Rx(in)Iy(in4)Ry(in)Ae(in2)Ix(in4)Sx(in3)Ma(in-lbs)Vag(lb)Vanet(lb)J* 1000(in4)Cw(in6)Xo(in)Ro(in)βBeta 162PDS125-33 0.0346 33 0.152 0.52 0.070 0.679 0.032 0.456 0.114 0.070 0.078 1541 632 123 0.06059 0.019 -1.065 1.344 0.371 30.8 250PDS125-33 0.0346 33 0.182 0.62 0.186 1.010 0.037 0.449 0.125 0.186 0.138 2697 1007 431 0.07267 0.046 -0.937 1.449 0.582 30.1 362PDS125-33 0.0346 33 0.221 0.75 0.439 1.409 0.041 0.433 0.127 0.439 0.200 3943 1024 541 0.08820 0.106 -0.816 1.685 0.766 29.6 400PDS125-33 0.0346 33 0.234 0.80 0.553 1.538 0.043 0.426 0.128 0.553 0.222 4394 957 602 0.09338 0.132 -0.783 1.777 0.806 29.5 600PDS125-33 0.0346 33 0.303 1.03 1.463 2.196 0.047 0.394 0.130 1.428 0.399 7021 630 630 0.12100 0.332 -0.647 2.323 0.922 28.6 Notes: – Calculated properties are based on AISI S100-12, North American Specification for Design of Cold-Formed Steel Structural Members and AISI S220-15, North American Standard for Cold-Formed Steel Framing—Nonstructural Members. – Effective properties incorporate the strength increase from the cold work of forming as applicable per AISI A7.2. – Tabulated gross properties, including torsional properties, are based on full-unreduced cross section of the studs, away from punchouts. – Tabulated gross properties, including torsional properties, are based on full-unreduced cross section of the tracks. – For deflection calculations, use the effective moment of inertia. – Allowable moment includes cold work of forming. – Allowable moment is taken as the lowest value based on local or distortional buckling. Distortional buckling strength is based on a k-phi = 0. – Web depth for track sections is equal to the nominal height plus two times the design thickness plus the bend radius. Hems on nonstructural track sections are ignored. 1 Web-height to thickness ratio exceeds 200. 2 Web-height to thickness ratio exceeds 260. ProSTUD® 33MIL DRYWALL STUD (AVAILABLE IN SELECT MARKETS) ProTRAK® 33MIL DRYWALL TRACK PHYSICAL AND STRUCTURAL PROPERTIES10 The technical content of this literature is effective 6/25/18 and supersedes all previous information.The technical content of this literature is effective 6/25/18 and supersedes all previous information. Pub. No. CD-ProSTUD 6/18clarkdietrich.com ClarkDietrich ProSTUD 33MIL physical and structural properties Notes: – Allowable screw connection capacities are based on Section E4 of the AISI S100-12 Specification. – When connecting materials of different steel thicknesses or tensile strengths, use the lowest values. Tabulated values assume two sheets of equal thickness are connected. – Screw shear and tension capacities were developed using published screw manufacturer data and evaluation reports available at the time of publication. – Screw capacities are based on Allowable Strength Design (ASD) and include a safety factor of 3.0. – When multiple fasteners are used, screws are assumed to have a center-to-center spacing of at least three times the nominal diameter (d). – Screws are assumed to have a center-of-screw to edge-of-steel dimension of at least 1-1/2 times the nominal diameter (d) of the screw. – Tension capacity is based on the lesser of pullout capacity in sheet closest to screw tip, or pullover capacity for sheet closest to screw head (using head diameter). – Screw capacities are governed by a conservative estimate of screw capacity, not by sheet steel failure. – For higher screw capacities, especially for screw strength, use specific screws from specific manufacturer. See manufacturer’s data for specific allowable values and installation instructions. ALLOWABLE SCREW DESIGN VALUES (LBS) 2-Sided PulloverPullout / ShearPulloutShear CONNECTIONS Member designation Thickness (mils) Design thickness (in) Yield(ksi)Ultimate #6 Screw (0.138" Dia., 5/16" Head)#8 Screw (0.164" Dia., 5/16" Head)#10 Screw (0.190" Dia., 0.34" Head) Shear, lbs 1-Side 2-Side Pullout, lbs Shear, lbs 1-Side 2-Side Pullout, lbs Shear, lbs 1-Side 2-Side Pullout, lbs PDS125-15 15 0.0158 50 50 52 62 123 31 56 62 123 37 61 67 134 43 PDS125-18 18 0.0190 70 70 95 104 208 52 104 104 208 62 112 113 226 72 PDS125-19 19 0.0200 65 65 96 102 203 51 104 102 203 60 112 111 221 70 PDS125-30 30 0.0312 33 33 95 80 161 40 103 80 161 48 111 88 175 55 PDS125-33 33 0.0346 33 45 151 122 243 61 164 122 243 72 177 132 265 84 11 12" max.The technical content of this literature is effective 6/25/18 and supersedes all previous information.Pub. No. CD-ProSTUD 6/18 clarkdietrich.com LIMITING HEIGHTS OVERVIEW ProSTUD, like any interior drywall stud, may be used in a variety of applications including walls, ceilings, and soffits. While some conditions may require the expertise of a design professional, many assemblies can be selected based on tabulated data. Using the diagrams below, locate the required assembly and follow the instructions for selecting the proper ProSTUD member. Composite Assemblies Composite limiting height data can be applied to walls where gypsum board is installed on both flanges of the stud for the full height of the wall. ProSTUD composite data is based on the 2015 International Building Code, and was tested and analyzed in accordance with the most recent version of AC86 (2015). Composite limiting height tables for ProSTUD members are available starting on page 10 of this catalog. In addition, a comprehensive offering is available at clarkdietrich.com. Chase Walls or Furred Walls Chase and furred walls are common, but the conditions vary greatly depending on the building requirements. While non- composite tables may be used conservatively, when in doubt, contact our Technical Services Hotline at 888-437-3244 for chase wall designs. Ceilings Interior ceilings are often supported by ProSTUD framing. The design criteria varies greatly based on the weight of the ceiling, bracing, and support points. You'll find a partial listing of ceiling span tables on page 18; visit clarkdietrich.com/ProSTUD for more comprehensive data. Non-Composite Assemblies Non-composite conditions are common in all structures. When the gypsum board stops at the ceiling level, but the stud continues to the deck, it is a non-composite condition. While there may be advantages to contacting Technical Services or a Design Professional, many conditions can be covered by limiting heights tables shown in this catalog or at clarkdietrich.com. When in doubt, call our complimentary Technical Services Hotline at 888-437-3244. Non-Composite FULLY BRACED Distance of unbraced length (Lu) can be found in the physical and structural properties starting on page 4. < Lu 48" o.c. max.Composite Gypsum board full height on both sides Non-Composite FULLY BRACED Bracing spacing above gypsum is less than Lu Non-Composite BRACED AT 48" o.c. Gypsum board placed on only one side WHICH ProSTUD® LIMITING HEIGHTS TABLE SHOULD I USE? 12" max.12" max.12 The technical content of this literature is effective 6/25/18 and supersedes all previous information.The technical content of this literature is effective 6/25/18 and supersedes all previous information. Pub. No. CD-ProSTUD 6/18clarkdietrich.com COMPOSITE—5/8" TYPE X ProSTUD® COMPOSITE LIMITING HEIGHTS Notes: – Allowable composite limiting heights were determined in accordance with ICC-ES AC86-2015. – Additional composite wall testing and analysis requirements of the SFIA Code Compliance Certification Program were observed. – In accordance with current building codes and AISI design standards, the 1/3 stress increase for strength was not used. – The composite limiting heights provided in the tables are based on a single layer of 5/8" Type X Gypsum Board from the following manufacturers: American, CertainTeed, Georgia Pacific, Continental, National, PABCO, and USG. – The gypsum board must be applied full height in the vertical orientation to each stud flange and installed in accordance with ASTM C754 using minimum No. 6 Type S drywall screws spaced as listed below: – Screws spaced a minimum of 16 in. o.c. to framing members spaced at 16 in. or 12 in. o.c. – Screws spaced a minimum of 12 in. o.c. to framing members spaced at 24 in. o.c. – No fasteners are required for attaching the stud to the track except as detailed in ASTM C754. – Stud end bearing must be a minimum of 1 inch. f Adjacent to the height value indicates that flexural stress controls the allowable wall height. s Adjacent to the height value indicates that shear/end reaction controls the allowable wall height. Width(in)Stud member Design thickness (in) Yield strength (ksi) Spacing(inches) Lateral Load (psf) 5psf 7.5psf 10psf L/120 L/240 L/360 L/120 L/240 L/360 L/120 L/240 L/360 1-5/8 ProSTUD 25162PDS125-15 0.0158 50 12 14' 1"11' 7"10' 1"12' 3"10' 1"8' 7"11' 2"9' 1"— 16 12' 9"10' 6"9' 0"11' 2"9' 1"—10' 2"8' 1"— 24 11' 2"9' 1"—9' 9"——8' 5"—— ProSTUD 20162PDS125-18 0.0190 70 12 13' 2''11' 5''10' 0''11' 6''10' 0''8' 5''10' 6''8' 9'' — 16 12' 10''11' 1''9' 9''11' 2''9' 8''7' 11''10' 2''8' 4'' — 24 11' 10''10' 3''8' 6''10' 4''8' 5''— 9' 2'' — — ProSTUD 30 162PDS125-30 0.0312 33 12 16' 3"12' 11"11' 3"14' 3"11' 3"9' 10"12' 11"10' 3"8' 8" 16 14' 9"11' 9"10' 3"12' 11"10' 3"8' 8"11' 9"9' 2"— 24 12' 11"10' 3"8' 8"11' 3"8' 8"—10' 3"—— ProSTUD 33 162PDS125-33 0.0346 33 12 17' 0"13' 6"11' 10"14' 10"11' 10"10' 4"13' 6"10' 9"9' 3" 16 15' 6"12' 3"10' 9"13' 6"10' 9"9' 3"12' 3"9' 9"— 24 13' 6"10' 9"9' 3"11' 10"9' 3"—10' 9"—— 2-1/2 ProSTUD 25250PDS125-15 0.0158 50 12 17' 2"14' 8"13' 0"15' 0"12' 10"11' 4"13' 3" f 11' 8"10' 4" 16 15' 7"13' 4"11' 9"13' 3" f 11' 8"10' 4"11' 5" f 10' 7"9' 1" 24 13' 3" f 11' 8"10' 4"10' 10" f 10' 2"8' 6"9' 4" f 8' 11"— ProSTUD 20250PDS125-18 0.0190 70 12 17' 5''14' 8''12' 11''15' 3''12' 10''11' 3''13' 10''11' 8''10' 3'' 16 16' 8''14' 0''12' 4''14' 6''12' 3''10' 9''13' 2''11' 2'' f 9' 9'' 24 15' 2''12' 10''11' 3''13' 2'' f 11' 2''9' 10''11' 5'' f 10' 2''8' 5'' ProSTUD 30 250PDS125-30 0.0312 33 12 19' 9"16' 3"14' 4"17' 3"14' 2"12' 6"15' 8"12' 11"11' 4" 16 17' 11"14' 9"13' 0"15' 8"12' 11"11' 4"14' 3"11' 9"10' 4" 24 15' 8"12' 11"11' 4"13' 8" f 11' 3"9' 11"12' 5"10' 3"8' 8" ProSTUD 33 250PDS125-33 0.0346 33 12 20' 4"16' 9"14' 9"17' 9"14' 7"12' 10"16' 2"13' 3"11' 8" 16 18' 6"15' 2"13' 5"16' 2"13' 3"11' 8"14' 8"12' 1"10' 7" 24 16' 2"13' 3"11' 8"14' 1"11' 7"10' 3"12' 10"10' 7"9' 1" 3-5/8 ProSTUD 25362PDS125-15 0.0158 50 12 21' 6"17' 1"14' 11"18' 4" f 14' 11"13' 0"15' 10" f 13' 7"11' 10" 16 19' 5" f 15' 6"13' 7"15' 10" f 13' 7"11' 10"13' 9" f 12' 4"10' 7" 24 15' 10" f 13' 7"11' 10"12' 11" f 11' 10"10' 1"11' 2" f 10' 7"9' 0" ProSTUD 20362PDS125-18 0.0190 70 12 22' 0''18' 2''15' 8''19' 3''15' 10''13' 8''17' 6''14' 5''12' 5'' 16 20' 6''16' 10''14' 7''17' 11''14' 9''12' 9''16' 3''13' 5''11' 6'' 24 18' 4''15' 1''13' 0''15' 11'' f 13' 2''11' 4''13' 9'' f 12' 0''10' 1'' ProSTUD 30 362PDS125-30 0.0312 33 12 25' 8"20' 5"17' 10"22' 5"17' 10"15' 7"20' 5"16' 2"14' 2" 16 23' 4"18' 6"16' 2"20' 5"16' 2"14' 2"18' 6"14' 8"12' 10" 24 20' 5"16' 2"14' 2"17' 10"14' 2"12' 3"16' 2"12' 10"11' 0" ProSTUD 33 362PDS125-33 0.0346 33 12 26' 7"21' 2"18' 5"23' 3"18' 5"16' 1"21' 2"16' 9"14' 8" 16 24' 2"19' 2"16' 9"21' 2"16' 9"14' 8"19' 2"15' 3"13' 4" 24 21' 2"16' 9"14' 8"18' 5"14' 8"12' 10"16' 9"13' 4"11' 6" 5/8" Type X Gypsum Board 13 The technical content of this literature is effective 6/25/18 and supersedes all previous information.Pub. No. CD-ProSTUD 6/18 clarkdietrich.com Notes: – Allowable composite limiting heights were determined in accordance with ICC-ES AC86-2015. – Additional composite wall testing and analysis requirements of the SFIA Code Compliance Certification Program were observed. – In accordance with current building codes and AISI design standards, the 1/3 stress increase for strength was not used. – The composite limiting heights provided in the tables are based on a single layer of 5/8" Type X Gypsum Board from the following manufacturers: American, CertainTeed, Georgia Pacific, Continental, National, PABCO, and USG. – The gypsum board must be applied full height in the vertical orientation to each stud flange and installed in accordance with ASTM C754 using minimum No. 6 Type S drywall screws spaced as listed below: – Screws spaced a minimum of 16 in. o.c. to framing members spaced at 16 in. or 12 in. o.c. – Screws spaced a minimum of 12 in. o.c. to framing members spaced at 24 in. o.c. – No fasteners are required for attaching the stud to the track except as detailed in ASTM C754. – Stud end bearing must be a minimum of 1 inch. f Adjacent to the height value indicates that flexural stress controls the allowable wall height. s Adjacent to the height value indicates that shear/end reaction controls the allowable wall height. 5/8" Type X Gypsum BoardProSTUD® COMPOSITE LIMITING HEIGHTS Width(in)Stud member Design thickness (in) Yield strength (ksi) Spacing(inches) Lateral Load (psf) 5psf 7.5psf 10psf L/120 L/240 L/360 L/120 L/240 L/360 L/120 L/240 L/360 4 ProSTUD 25400PDS125-15 0.0158 50 12 22' 8"18' 0"15' 9"19' 1" f 15' 9"13' 9"16' 6" f 14' 4"12' 6" 16 20' 3" f 16' 4"14' 4"16' 6" f 14' 4"12' 6"14' 4" f 13' 0"11' 3" 24 16' 6" f 14' 4"12' 6"13' 6" f 12' 6"10' 8"11' 8" f 11' 3"9' 6" ProSTUD 20400PDS125-18 0.0190 70 12 22' 9''18' 8''16' 4''19' 11''16' 4''14' 3''18' 1''14' 10''13' 0'' 16 21' 4''17' 7''15' 4''18' 8''15' 4''13' 5''16' 11''13' 11''12' 2'' 24 19' 3''15' 10''13' 10''16' 7'' f 13' 10''12' 1''14' 4'' f 12' 6''10' 9'' ProSTUD 30 400PDS125-30 0.0312 33 12 27' 5"21' 9"19' 0"24' 0"19' 0"16' 8"21' 9"17' 4"15' 1" 16 24' 11"19' 10"17' 4"21' 9"17' 4"15' 1"19' 10"15' 9"13' 9" 24 21' 9"17' 4"15' 1"19' 0"15' 1"13' 2"17' 4"13' 9"11' 10" ProSTUD 33 400PDS125-33 0.0346 33 12 27' 10"22' 9"20' 1"24' 3"19' 11"17' 7"22' 1"18' 1"15' 11" 16 25' 3"20' 8"18' 3"22' 1"18' 1"15' 11"20' 1"16' 5"14' 6" 24 22' 1"18' 1"15' 11"19' 3"15' 10"13' 11"17' 6"14' 4"12' 8" 6 ProSTUD 25600PDS125-15 0.0158 50 12 27' 10" f 24' 2"21' 5"22' 9" f 21' 1"18' 8"19' 8" f 19' 2"17' 0" 16 24' 1" f 21' 11"19' 5"19' 8" f 19' 2"17' 0"17' 1" f 17' 1" f 15' 5" 24 19' 8" f 19' 2"17' 0"16' 1" f 16' 1" f 14' 9"13' 11" f 13' 11" f 13' 4" ProSTUD 20600PDS125-18 0.0190 70 12 32' 1''25' 6''22' 3''28' 1''22' 3''19' 5''24' 4'' f 20' 3''17' 8'' 16 29' 10''23' 8''20' 8''24' 10'' f 20' 8''18' 1''21' 6'' f 18' 9''16' 5'' 24 25' 5'' f 21' 1''18' 5''20' 9'' f 18' 5''16' 1''18' 0'' f 16' 9''14' 6'' ProSTUD 30 600PDS125-30 0.0312 33 12 36' 7"29' 1"25' 5"32' 0"25' 5"22' 2"29' 1"23' 1"20' 2" 16 33' 3"26' 5"23' 1"29' 1"23' 1"20' 2"26' 5"20' 11"18' 4" 24 29' 1"23' 1"20' 2"25' 5"20' 2"17' 7"22' 6" f 18' 4"— ProSTUD 33 600PDS125-33 0.0346 33 12 36' 8"30' 1"26' 6"32' 0"26' 3"23' 2"29' 1"23' 10"21' 0" 16 33' 3"27' 4"24' 1"29' 1"23' 10"21' 0"26' 5"21' 8"19' 1" 24 29' 1"23' 10"21' 0"25' 5"20' 10"18' 4"23' 1"18' 11"— COMPOSITE—5/8" TYPE X14 The technical content of this literature is effective 6/25/18 and supersedes all previous information.The technical content of this literature is effective 6/25/18 and supersedes all previous information. Pub. No. CD-ProSTUD 6/18clarkdietrich.com NON-COMPOSITE FULLY BRACED ClarkDietrich ProSTUD Non-Composite Limiting Heights—FULLY BRACEDProSTUD® NON-COMPOSITE LIMITING HEIGHTS Notes: – Heights are based on AISI S100-12, North American Specification and AISI S220-15, North American Standard for Cold-Formed Steel Framing—Nonstructural Members, using steel properties alone. – Above listed Non-Composite Limiting Heights are applicable when the unbraced length is less than or equal to Lu. – Heights are limited by moment, deflection, shear, and web crippling (assuming 1" end reaction bearing). ٭ Web stiffeners are required at bearing points. Depth (in)Stud member Design thickness (in) Yield strength (ksi) Spacing o.c. (in) Lateral Load (psf) 5psf 7.5psf 10psfL/120 L/240 L/360 L/120 L/240 L/360 L/120 L/240 L/360 1-5/8 ProSTUD 25162PDS125-15 0.0158 50 12 9' 2" 7' 4" 6' 4" 8' 0" 6' 4" 5' 7" 6' 11" 5' 9" 5' 1" 0.0158 50 16 8' 4" 6' 8" 5' 9" 6' 11" 5' 9" 5' 1" 6' 0" 5' 3" 4' 7" 0.0158 50 24 6' 11" 5' 9" 5' 1" 5' 8" 5' 1" 4' 5" 4' 11" 4' 7" 4' 0" ProSTUD 20162PDS125-18 0.0190 70 12 9' 9" 7' 9" 6' 9" 8' 6" 6' 9" 5' 11" 7' 9" 6' 2" 5' 4" 0.0190 70 16 8' 10" 7' 0" 6' 2" 7' 9" 6' 2" 5' 4" 7' 0" 5' 7" 4' 10" 0.0190 70 24 7' 9" 6' 2" 5' 4" 6' 9" 5' 4" 4' 8" 6' 2" 4' 10" 4' 3" ProSTUD 30MIL162PDS125-30 0.0312 33 12 11' 10" 9' 5" 8' 3" 10' 4" 8' 3" 7' 2" 9' 5" 7' 6" 6' 6" 0.0312 33 16 10' 9" 8' 7" 7' 6" 9' 5" 7' 6" 6' 6" 8' 2" 6' 9" 5' 11" 0.0312 33 24 9' 5" 7' 6" 6' 6" 7' 8" 6' 6" 5' 8" 6' 8" 5' 11" 5' 2" ProSTUD 33MIL162PDS125-33 0.0346 33 12 12' 3" 9' 9" 8' 6" 10' 8" 8' 6" 7' 5" 9' 9" 7' 9" 6' 9" 0.0346 33 16 11' 2" 8' 10" 7' 9" 9' 9" 7' 9" 6' 9" 8' 9" 7' 0" 6' 1" 0.0346 33 24 9' 9" 7' 9" 6' 9" 8' 3" 6' 9" 5' 11" 7' 2" 6' 1" 5' 4" 2-1/2 ProSTUD 25250PDS125-15 0.0158 50 12 12' 8" 10' 2" 8' 11" 10' 4" 8' 11" 7' 9" 8' 11" 8' 1" 7' 1" 0.0158 50 16 10' 11" 9' 3" 8' 1" 8' 11" 8' 1" 7' 1" 7' 9" 7' 4" 6' 5" 0.0158 50 24 8' 11" 8' 1" 7' 1" 7' 4" 7' 1" 6' 2" 6' 4" 6' 4" 5' 7" ProSTUD 20250PDS125-18 0.0190 70 12 13' 9" 10' 11" 9' 6" 12' 0" 9' 6" 8' 4" 10' 11" 8' 8" 7' 7" 0.0190 70 16 12' 6" 9' 11" 8' 8" 10' 11" 8' 8" 7' 7" 9' 11" 7' 10" 6' 10" 0.0190 70 24 10' 11" 8' 8" 7' 7" 9' 6" 7' 7" 6' 7" 8' 4" 6' 10" 6' 0" ProSTUD 30MIL250PDS125-30 0.0312 33 12 16' 5" 13' 0" 11' 4" 14' 4" 11' 4" 9' 11" 12' 6" 10' 4" 9' 0" 0.0312 33 16 14' 11" 11' 10" 10' 4" 12' 6" 10' 4" 9' 0" 10' 10" 9' 5" 8' 2" 0.0312 33 24 12' 6" 10' 4" 9' 0" 10' 3" 9' 0" 7' 11" 8' 10" 8' 2" 7' 2" ProSTUD 33MIL250PDS125-33 0.0346 33 12 16' 11" 13' 5" 11' 9" 14' 10" 11' 9" 10' 3" 13' 5" 10' 8" 9' 4" 0.0346 33 16 15' 5" 12' 3" 10' 8" 13' 5" 10' 8" 9' 4" 11' 7" 9' 8" 8' 6" 0.0346 33 24 13' 5" 10' 8" 9' 4" 10' 11" 9' 4" 8' 2" 9' 6" 8' 6" 7' 5" 3-5/8 ProSTUD 25٭362PDS125-15 0.0158 50 12 15' 0" 13' 7" 11' 10" 12' 3" 11' 10" 10' 4" 10' 7" 10' 7" 9' 5" 0.0158 50 16 13' 0" 12' 4" 10' 9" 10' 7" 10' 7" 9' 5" 9' 2" 9' 2" 8' 6" 0.0158 50 24 10' 7" 10' 7" 9' 5" 8' 8" 8' 8" 8' 3" 7' 6" 7' 6" 7' 5" ProSTUD 20362PDS125-18 0.0190 70 12 18' 4" 14' 6" 12' 8" 16' 0" 12' 8" 11' 1" 14' 5" 11' 6" 10' 1" 0.0190 70 16 16' 8" 13' 2" 11' 6" 14' 5" 11' 6" 10' 1" 12' 5" 10' 6" 9' 2" 0.0190 70 24 14' 5" 11' 6" 10' 1" 11' 9" 10' 1" 8' 10" 10' 2" 9' 2" 8' 0" ProSTUD 30MIL362PDS125-30 0.0312 33 12 21' 2" 17' 4" 15' 2" 17' 3" 15' 2" 13' 3" 15' 0" 13' 9" 12' 0" 0.0312 33 16 18' 4" 15' 9" 13' 9" 15' 0" 13' 9" 12' 0" 12' 11" 12' 6" 10' 11" 0.0312 33 24 15' 0" 13' 9" 12' 0" 12' 3" 12' 0" 10' 6" 10' 7" 10' 7" 9' 6" ProSTUD 33MIL362PDS125-33 0.0346 33 12 22' 7" 17' 11" 15' 8" 18' 9" 15' 8" 13' 8" 16' 3" 14' 3" 12' 5" 0.0346 33 16 19' 10" 16' 3" 14' 3" 16' 3" 14' 3" 12' 5" 14' 0" 12' 11" 11' 3" 0.0346 33 24 16' 3" 14' 3" 12' 5" 13' 3" 12' 5" 10' 10" 11' 6" 11' 3" 9' 10" 4 ProSTUD 25٭400PDS125-15 0.0158 50 12 15' 9" 14' 6" 12' 8" 12' 11" 12' 8" 11' 1" 11' 2" 11' 2" 10' 1" 0.0158 50 16 13' 8" 13' 2" 11' 6" 11' 2" 11' 2" 10' 1" 9' 8" 9' 8" 9' 2" 0.0158 50 24 11' 2" 11' 2" 10' 1" 9' 1" 9' 1" 8' 9" 7' 11" 7' 11" 7' 11" ProSTUD 20٭400PDS125-18 0.0190 70 12 19' 7" 15' 6" 13' 7" 17' 1" 13' 7" 11' 10" 15' 4" 12' 4" 10' 9" 0.0190 70 16 17' 9" 14' 1" 12' 4" 15' 4" 12' 4" 10' 9" 13' 3" 11' 2" 9' 9" 0.0190 70 24 15' 4" 12' 4" 10' 9" 12' 6" 10' 9" 9' 5" 10' 10" 9' 9" 8' 7" ProSTUD 30MIL400PDS125-30 0.0312 33 12 22' 4" 18' 8" 16' 4" 18' 3" 16' 4" 14' 3" 15' 9" 14' 10" 13' 0" 0.0312 33 16 19' 4" 17' 0" 14' 10" 15' 9" 14' 10" 13' 0" 13' 8" 13' 6" 11' 9" 0.0312 33 24 15' 9" 14' 10" 13' 0" 12' 11" 12' 11" 11' 4" 11' 2" 11' 2" 10' 3" ProSTUD 33MIL400PDS125-33 0.0346 33 12 24' 2" 19' 4" 16' 11" 19' 9" 16' 11" 14' 9" 17' 1" 15' 4" 13' 5" 0.0346 33 16 21' 0" 17' 7" 15' 4" 17' 1" 15' 4" 13' 5" 14' 10" 13' 11" 12' 2" 0.0346 33 24 17' 1" 15' 4" 13' 5" 14' 0" 13' 5" 11' 9" 12' 1" 12' 1" 10' 8" 6 ProSTUD 25٭600PDS125-15 0.0158 50 12 19' 3" 19' 2" 16' 9" 15' 9" 15' 9" 14' 8" 11' 11" 11' 11" 11' 11" 0.0158 50 16 16' 8" 16' 8" 15' 3" 11' 11" 11' 11" 11' 11" 8' 11" 8' 11" 8' 11" 0.0158 50 24 11' 11" 11' 11" 11' 11" 7' 11" 7' 11" 7' 11" 6' 0" 6' 0" 6' 0" ProSTUD 20٭600PDS125-18 0.0190 70 12 26' 0" 20' 8" 18' 0" 21' 11" 18' 0" 15' 9" 19' 0" 16' 4" 14' 4" 0.0190 70 16 23' 3" 18' 9" 16' 4" 19' 0" 16' 4" 14' 4" 15' 7" 14' 11" 13' 0" 0.0190 70 24 19' 0" 16' 4" 14' 4" 13' 10" 13' 10" 12' 6" 10' 5" 10' 5" 10' 5" ProSTUD 30MIL600PDS125-30 0.0312 33 12 28' 4" 25' 7" 22' 4" 23' 2" 22' 4" 19' 7" 20' 1" 20' 1" 17' 9" 0.0312 33 16 24' 7" 23' 3" 20' 4" 20' 1" 20' 1" 17' 9" 17' 4" 17' 4" 16' 2" 0.0312 33 24 20' 1" 20' 1" 17' 9" 16' 4" 16' 4" 15' 6" 14' 2" 14' 2" 14' 1" ProSTUD 33MIL600PDS125-33 0.0346 33 12 30' 7" 26' 7" 23' 2" 25' 0" 23' 2" 20' 3" 21' 8" 21' 1" 18' 5" 0.0346 33 16 26' 6" 24' 1" 21' 1" 21' 8" 21' 1" 18' 5" 18' 9" 18' 9" 16' 9" 0.0346 33 24 21' 8" 21' 1" 18' 5" 17' 8" 17' 8" 16' 1" 15' 4" 15' 4" 14' 7" 15 The technical content of this literature is effective 6/25/18 and supersedes all previous information.Pub. No. CD-ProSTUD 6/18 clarkdietrich.com Notes: – Heights are based on AISI S100-12, North American Specification and AISI S220-15, North American Standard for Cold-Formed Steel Framing—Nonstructural Members, using steel properties alone. – Above listed Non-Composite Limiting Heights are applicable when the unbraced length is less than or equal to Lu. – Heights are limited by moment, deflection, shear, and web crippling (assuming 1" end reaction bearing). ٭ Web stiffeners are required at bearing points. NON-COMPOSITE BRACED AT 48" O.C. ClarkDietrich ProSTUD Non-Composite Limiting Heights—BRACED AT 48" o.c.ProSTUD® NON-COMPOSITE LIMITING HEIGHTS Depth (in)Stud member Design thickness (in) Yield strength (ksi) Spacing o.c. (in) Lateral Load (psf) 5psf 7.5psf 10psfL/120 L/240 L/360 L/120 L/240 L/360 L/120 L/240 L/360 1-5/8 ProSTUD 25162PDS125-15 0.0158 50 12 8' 1" 7' 4" 6' 4" 6' 7" 6' 4" 5' 7" 5' 9" 5' 9" 5' 1" 0.0158 50 16 7' 0" 6' 8" 5' 9" 5' 9" 5' 9" 5' 1" 4' 11" 4' 11" 4' 7" 0.0158 50 24 5' 9" 5' 9" 5' 1" 4' 8" 4' 8" 4' 5" 4' 0" 4' 0" 4' 0" ProSTUD 20162PDS125-18 0.0190 70 12 9' 6" 7' 9" 6' 9" 7' 9" 6' 9" 5' 11" 6' 9" 6' 2" 5' 4" 0.0190 70 16 8' 3" 7' 0" 6' 2" 6' 9" 6' 2" 5' 4" 5' 10" 5' 7" 4' 10" 0.0190 70 24 6' 9" 6' 2" 5' 4" 5' 6" 5' 4" 4' 8" 4' 9" 4' 9" 4' 3" ProSTUD 30MIL162PDS125-30 0.0312 33 12 11' 10" 9' 5" 8' 3" 10' 3" 8' 3" 7' 2" 8' 11" 7' 6" 6' 6" 0.0312 33 16 10' 9" 8' 7" 7' 6" 8' 11" 7' 6" 6' 6" 7' 8" 6' 9" 5' 11" 0.0312 33 24 8' 11" 7' 6" 6' 6" 7' 3" 6' 6" 5' 8" 6' 3" 5' 11" 5' 2" ProSTUD 33MIL162PDS125-33 0.0346 33 12 12' 3" 9' 9" 8' 6" 10' 8" 8' 6" 7' 5" 9' 5" 7' 9" 6' 9" 0.0346 33 16 11' 2" 8' 10" 7' 9" 9' 5" 7' 9" 6' 9" 8' 2" 7' 0" 6' 1" 0.0346 33 24 9' 5" 7' 9" 6' 9" 7' 8" 6' 9" 5' 11" 6' 8" 6' 1" 5' 4" 2-1/2 ProSTUD 25250PDS125-15 0.0158 50 12 10' 5" 10' 2" 8' 11" 8' 6" 8' 6" 7' 9" 7' 4" 7' 4" 7' 1" 0.0158 50 16 9' 0" 9' 0" 8' 1" 7' 4" 7' 4" 7' 1" 6' 5" 6' 5" 6' 5" 0.0158 50 24 7' 4" 7' 4" 7' 1" 6' 0" 6' 0" 6' 0" 5' 3" 5' 3" 5' 3" ProSTUD 20250PDS125-18 0.0190 70 12 13' 5" 10' 11" 9' 6" 10' 11" 9' 6" 8' 4" 9' 6" 8' 8" 7' 7" 0.0190 70 16 11' 7" 9' 11" 8' 8" 9' 6" 8' 8" 7' 7" 8' 3" 7' 10" 6' 10" 0.0190 70 24 9' 6" 8' 8" 7' 7" 7' 9" 7' 7" 6' 7" 6' 8" 6' 8" 6' 0" ProSTUD 30MIL250PDS125-30 0.0312 33 12 16' 5" 13' 0" 11' 4" 13' 8" 11' 4" 9' 11" 11' 10" 10' 4" 9' 0" 0.0312 33 16 14' 6" 11' 10" 10' 4" 11' 10" 10' 4" 9' 0" 10' 3" 9' 5" 8' 2" 0.0312 33 24 11' 10" 10' 4" 9' 0" 9' 8" 9' 0" 7' 11" 8' 4" 8' 2" 7' 2" ProSTUD 33MIL250PDS125-33 0.0346 33 12 16' 11" 13' 5" 11' 9" 14' 4" 11' 9" 10' 3" 12' 5" 10' 8" 9' 4" 0.0346 33 16 15' 3" 12' 3" 10' 8" 12' 5" 10' 8" 9' 4" 10' 9" 9' 8" 8' 6" 0.0346 33 24 12' 5" 10' 8" 9' 4" 10' 2" 9' 4" 8' 2" 8' 10" 8' 6" 7' 5" 3-5/8 ProSTUD 25٭362PDS125-15 0.0158 50 12 12' 5" 12' 5" 11' 10" 10' 1" 10' 1" 10' 1" 8' 9" 8' 9" 8' 9" 0.0158 50 16 10' 9" 10' 9" 10' 9" 8' 9" 8' 9" 8' 9" 7' 7" 7' 7" 7' 7" 0.0158 50 24 8' 9" 8' 9" 8' 9" 7' 2" 7' 2" 7' 2" 6' 2" 6' 2" 6' 2" ProSTUD 20362PDS125-18 0.0190 70 12 15' 2" 14' 6" 12' 8" 12' 5" 12' 5" 11' 1" 10' 9" 10' 9" 10' 1" 0.0190 70 16 13' 2" 13' 2" 11' 6" 10' 9" 10' 9" 10' 1" 9' 4" 9' 4" 9' 2" 0.0190 70 24 10' 9" 10' 9" 10' 1" 8' 9" 8' 9" 8' 9" 7' 7" 7' 7" 7' 7" ProSTUD 30MIL362PDS125-30 0.0312 33 12 20' 0" 17' 4" 15' 2" 16' 4" 15' 2" 13' 3" 14' 1" 13' 9" 12' 0" 0.0312 33 16 17' 3" 15' 9" 13' 9" 14' 1" 13' 9" 12' 0" 12' 3" 12' 3" 10' 11" 0.0312 33 24 14' 1" 13' 9" 12' 0" 11' 6" 11' 6" 10' 6" 10' 0" 10' 0" 9' 6" ProSTUD 33MIL362PDS125-33 0.0346 33 12 21' 3" 17' 11" 15' 8" 17' 4" 15' 8" 13' 8" 15' 0" 14' 3" 12' 5" 0.0346 33 16 18' 5" 16' 3" 14' 3" 15' 0" 14' 3" 12' 5" 13' 0" 12' 11" 11' 3" 0.0346 33 24 15' 0" 14' 3" 12' 5" 12' 3" 12' 3" 10' 10" 10' 8" 10' 8" 9' 10" 4 ProSTUD 25٭400PDS125-15 0.0158 50 12 13' 0" 13' 0" 12' 8" 10' 8" 10' 8" 10' 8" 9' 2" 9' 2" 9' 2" 0.0158 50 16 11' 3" 11' 3" 11' 3" 9' 2" 9' 2" 9' 2" 8' 0" 8' 0" 8' 0" 0.0158 50 24 9' 2" 9' 2" 9' 2" 7' 6" 7' 6" 7' 6" 6' 6" 6' 6" 6' 6" ProSTUD 20٭400PDS125-18 0.0190 70 12 16' 3" 15' 6" 13' 7" 13' 3" 13' 3" 11' 10" 11' 6" 11' 6" 10' 9" 0.0190 70 16 14' 1" 14' 1" 12' 4" 11' 6" 11' 6" 10' 9" 9' 11" 9' 11" 9' 9" 0.0190 70 24 11' 6" 11' 6" 10' 9" 9' 4" 9' 4" 9' 4" 8' 1" 8' 1" 8' 1" ProSTUD 30MIL400PDS125-30 0.0312 33 12 21' 1" 18' 8" 16' 4" 17' 2" 16' 4" 14' 3" 14' 11" 14' 10" 13' 0" 0.0312 33 16 18' 3" 17' 0" 14' 10" 14' 11" 14' 10" 13' 0" 12' 11" 12' 11" 11' 9" 0.0312 33 24 14' 11" 14' 10" 13' 0" 12' 2" 12' 2" 11' 4" 10' 6" 10' 6" 10' 3" ProSTUD 33MIL400PDS125-33 0.0346 33 12 22' 5" 19' 4" 16' 11" 18' 4" 16' 11" 14' 9" 15' 10" 15' 4" 13' 5" 0.0346 33 16 19' 5" 17' 7" 15' 4" 15' 10" 15' 4" 13' 5" 13' 9" 13' 9" 12' 2" 0.0346 33 24 15' 10" 15' 4" 13' 5" 13' 0" 13' 0" 11' 9" 11' 3" 11' 3" 10' 8" 6 ProSTUD 25٭600PDS125-15 0.0158 50 12 15' 11" 15' 11" 15' 11" 13' 0" 13' 0" 13' 0" 11' 3" 11' 3" 11' 3" 0.0158 50 16 13' 9" 13' 9" 13' 9" 11' 3" 11' 3" 11' 3" 8' 11" 8' 11" 8' 11" 0.0158 50 24 11' 3" 11' 3" 11' 3" 7' 11" 7' 11" 7' 11" 6' 0" 6' 0" 6' 0" ProSTUD 20٭600PDS125-18 0.0190 70 12 20' 10" 20' 8" 18' 0" 17' 0" 17' 0" 15' 9" 14' 8" 14' 8" 14' 4" 0.0190 70 16 18' 0" 18' 0" 16' 4" 14' 8" 14' 8" 14' 4" 12' 9" 12' 9" 12' 9" 0.0190 70 24 14' 8" 14' 8" 14' 4" 12' 0" 12' 0" 12' 0" 10' 5" 10' 5" 10' 5" ProSTUD 30MIL600PDS125-30 0.0312 33 12 26' 9" 25' 7" 22' 4" 21' 10" 21' 10" 19' 7" 18' 11" 18' 11" 17' 9" 0.0312 33 16 23' 2" 23' 2" 20' 4" 18' 11" 18' 11" 17' 9" 16' 5" 16' 5" 16' 2" 0.0312 33 24 18' 11" 18' 11" 17' 9" 15' 5" 15' 5" 15' 5" 13' 5" 13' 5" 13' 5" ProSTUD 33MIL600PDS125-33 0.0346 33 12 28' 4" 26' 7" 23' 2" 23' 2" 23' 2" 20' 3" 20' 1" 20' 1" 18' 5" 0.0346 33 16 24' 7" 24' 1" 21' 1" 20' 1" 20' 1" 18' 5" 17' 5" 17' 5" 16' 9" 0.0346 33 24 20' 1" 20' 1" 18' 5" 16' 5" 16' 5" 16' 1" 14' 2" 14' 2" 14' 2" 16 The technical content of this literature is effective 6/25/18 and supersedes all previous information.The technical content of this literature is effective 6/25/18 and supersedes all previous information. Pub. No. CD-ProSTUD 6/18clarkdietrich.com SOUND TESTING Notes: – Sound Assemblies are certified by Western Electro-Acoustic Laboratories. – NVLAP Accredited for ASTM E90 & E413, ISO Certified. – See STC test reports at www.clarkdietrich.com/ProSTUD for detailed requirements of construction of wall assembly. * Values are the same for R-11 insulation. Contact ClarkDietrich Technical Services at 888-437-3244 for questions about ProSTUD sound assemblies. Partition type Assembly description STC Rating / Test Report ProSTUD 25 (15mil)ProSTUD 20 (18mil)ProSTUD 30MIL ProSTUD 33MIL 3-5/8" ProSTUD @ 24" o.c. 1 layer 5/8" Type X GWB on each side 43 TL09-539 38 TL13-190 36 TL13-204 36 TL13-197 3-5/8" ProSTUD @ 24" o.c. 3-1/2" R-13* unfaced insulation 1 layer 5/8" Type X GWB on each side 48 TL09-540 41 TL13-189 37 TL13-203 37 TL13-196 3-5/8" ProSTUD @ 24" o.c. 3-1/2" R-13* unfaced insulation 1 layer 5/8" Type X GWB on one side 2 layers 5/8" Type X GWB on the other side 49 TL13-167 44 TL13-188 40 TL13-202 42 TL13-195 3-5/8" ProSTUD @ 24" o.c. 3-1/2" R-13* unfaced insulation 2 layers 5/8" Type X GWB on each side 54 TL09-538 45 TL13-187 42 TL13-201 45 TL13-194 3-5/8" ProSTUD @ 24" o.c. 3-1/2" R-13* unfaced insulation RC-Deluxe w/ 1 layer 5/8" Type X GWB on one side 1 layer 5/8" Type X GWB on the other side 53 TL13-183 48 TL13-191 48 TL13-205 50 TL16-369 3-5/8" ProSTUD @ 24" o.c. 3-1/2" R-13* unfaced insulation RC-Deluxe w/ 2 layers 5/8" Type X GWB on one side 1 layer 5/8" Type X GWB on the other side 59 TL09-543 54 TL13-192 55 TL16-367 56 TL16-370 3-5/8" ProSTUD @ 24" o.c. 3-1/2" R-13* unfaced insulation RC-Deluxe w/ 2 layers 5/8" Type X GWB on one side 2 layers 5/8" Type X GWB on the other side 62 TL13-181 59 TL13-193 58 TL16-368 58 TL13-200 P roSTUD® 3-5/8" SOUND ASSEMBLIES 17 The technical content of this literature is effective 6/25/18 and supersedes all previous information.Pub. No. CD-ProSTUD 6/18 clarkdietrich.com SOUND TESTING Notes: – Sound Assemblies are certified by Western Electro-Acoustic Laboratories. – NVLAP Accredited for ASTM E90 & E413, ISO Certified. – See STC test reports at www.clarkdietrich.com/ProSTUD for detailed requirements of construction of wall assembly. * Values are the same for R-11 insulation. Contact ClarkDietrich Technical Services at 888-437-3244 for questions about ProSTUD sound assemblies. ProSTUD 1-5/8" STUD CHASE SOUND ASSEMBLIES Gypsum type Side A Side B Insulation type Stud spacing STC Rating Test report Partition typeProSTUD 25 (15mil) 5/8" Type X 1 layer 1 layer R-13* unfaced 24"55 TL09-590 1 Similar 5/8" Type X 1 layer 2 layers R-13* unfaced 24"59 TL09-591 1 Similar 5/8" Type X 2 layers 2 layers R-13* unfaced 24"61 TL09-592 1 Partition Type 1 Partition Type 2 Partition Type 3 ProSTUD 2-1/2" STUD CHASE SOUND ASSEMBLIES Gypsum type Side A Side B Insulation type Stud spacing STC Rating Test report Partition typeProSTUD 25 (15mil) 5/8" Type X 1 layer 1 layer R-13* unfaced*24"58 TL09-593 2 Similar 5/8" Type X 1 layer 2 layers R-13* unfaced*24"63 TL09-594 2 Similar 5/8" Type X 2 layers 2 layers R-13* unfaced*24"65 TL09-595 2 ProSTUD 3-5/8" STUD CHASE SOUND ASSEMBLIES Gypsum type Side A Side B Insulation type Stud spacing STC Rating Test report Partition typeProSTUD 25 (15mil) 5/8" Type X 1 layer 1 layer R-13* unfaced 16"49 TL09-587 3 5/8" Type X 1 layer 2 layers R-13* unfaced 16"52 TL09-588 3 Similar 5/8" Type X 2 layers 2 layers R-13* unfaced 16"56 TL09-589 3 Similar Two parallel rows Staggered in opposite walls Staggered studs in 6" track 18 The technical content of this literature is effective 6/25/18 and supersedes all previous information.The technical content of this literature is effective 6/25/18 and supersedes all previous information. Pub. No. CD-ProSTUD 6/18clarkdietrich.com UL® FIRE TESTING P roSTUD CHASE OR DOUBLE STUD—FIRE ASSEMBLIESA ProSTUD TABLE 1: MINIMUM DEPTH OF ProSTUD REQUIREDA UL design no.Hourly rating ProSTUD minimum thickness ProSTUD minimum depth U420 2 ProSTUD 25 (15mil)1-5/8" U436 1, 2, or 3 ProSTUD 20 (18mil)1-5/8" U444 2 ProSTUD 25 (15mil)1-5/8" U445*1 ProSTUD 33 (33mil)1-5/8" U466 1 ProSTUD 20 (18mil)2-1/2" U493 2 ProSTUD 25 (15mil)2-1/2" V437 1 ProSTUD 20 (18mil)1-5/8" UL design no.Hourly rating ProSTUD minimum thickness ProSTUD minimum depth V442 2 ProSTUD 25 (15mil)1-5/8" V464 1 ProSTUD 25 (15mil)3-5/8" V469*1 ProSTUD 33 (33mil)2-1/2" V469 2 ProSTUD 20 (18mil)2-1/2" V488 1 or 2 ProSTUD 20 (18mil)2-1/2" V490*1 or 2 ProSTUD 33 (33mil)2-1/2" V496 1 or 2 ProSTUD 20 (18mil)2-1/2" Notes: ASee UL listing for detailed requirements of construction of tested assembly. *ProSTUD meets or exceeds the description of the generic stud/track listed in the UL assembly. ProSTUD® SINGLE STUD WALL—FIRE ASSEMBLIESA UL design no.Hourly rating ProSTUD minimum thickness ProSTUD minimum depth U403 2 ProSTUD 20 (18mil)3-5/8" U407 1/2 or 1 ProSTUD 25 (15mil)3-5/8" U408 2 ProSTUD 20 (18mil)3-5/8" U411 2 ProSTUD 25 (15mil)2-1/2" U412 2 ProSTUD 25 (15mil)1-5/8" U419 1, 2, 3 or 4 ProSTUD 25 (15mil)(See Table 1 below) U421 2 ProSTUD 25 (15mil)3-5/8" U431 4 ProSTUD 20 (18mil)3-5/8" U435 3 or 4 ProSTUD 25 (15mil)1-5/8" U442*1 ProSTUD 33MIL 2-1/2" U450 1 or 3 ProSTUD 20 (18mil)3-5/8" U451 1 ProSTUD 20 (18mil)2-1/2" U454 2 ProSTUD 20 (18mil)2-1/2" U463 3 or 4 ProSTUD 20 (18mil)1-5/8" U465 1 ProSTUD 20 (18mil)3-5/8" U471 1-1/2 ProSTUD 20 (18mil)3-5/8" U475 1, 2 or 3 ProSTUD 20 (18mil)3-5/8" U478 3 ProSTUD 20 (18mil)1-5/8" U484*2 ProSTUD 33MIL 2-1/2" U488*1 ProSTUD 33MIL 2-1/2" U490 4 ProSTUD 20 (18mil)2-1/2" U491 2 ProSTUD 20 (18mil)3-5/8" U494 1 ProSTUD 20 (18mil)2-1/2" U495 1 or 2 ProSTUD 20 (18mil)3-5/8" U496 1 ProSTUD 20 (18mil)1-5/8" UL design no.Hourly rating ProSTUD minimum thickness ProSTUD minimum depth V410 2 ProSTUD 20 (18mil)1-5/8" V412 2 ProSTUD 20 (18mil)3-5/8" V416 1 ProSTUD 20 (18mil)3-5/8" V417 1 ProSTUD 20 (18mil)3-5/8" V418 2 ProSTUD 20 (18mil)1-5/8" V419 2 ProSTUD 20 (18mil)2-1/2" V425 1 ProSTUD 20 (18mil)2-1/2" V435 1 ProSTUD 20 (18mil)3-5/8" V438 1, 2, 3 or 4 ProSTUD 25 (15mil)(See Table 1 below) V443 4 ProSTUD 20 (18mil)3-5/8" V444 1 ProSTUD 20 (18mil)3-5/8" V448 1 ProSTUD 20 (18mil)3-5/8" V449 2 ProSTUD 20 (18mil)3-5/8" V450 1 ProSTUD 25 (15mil)3-5/8" V450 2 ProSTUD 25 (15mil)2-1/2" V452 1 or 2 ProSTUD 20 (18mil)3-5/8" V453*1-1/2 ProSTUD 33MIL 6" V461*1 ProSTUD 33MIL 3-5/8" V476 1 or 3 ProSTUD 20 (18mil)3-5/8" V477 1, 2, 3 or 4 ProSTUD 25 (15mil)(See Table 1 below) V487 2 ProSTUD 20 (18mil)1-5/8" V489 1, 2, 3 or 4 ProSTUD 25 (15mil)(See Table 1 below) V498 1, 2, 3 or 4 ProSTUD 25 (15mil)(See Table 1 below) W411 1/2 or 1 ProSTUD 25 (15mil)3-5/8" W415 1 or 2 ProSTUD 20 (18mil)2-1/2" W424 1 ProSTUD 25 (15mil)3-5/8" Hourly rating Min. stud depth (in)No. of layers and thickness of gypsum board UL U419 UL V438 UL V477 UL V489 UL V498 1 2-1/2"1 layer, 1/2"———— 1 3-5/8"1 layer, 5/8" 2 1-5/8"2 layer, 1/2" 2 1-5/8"2 layer, 5/8"— 2 2-1/2"2 layer, 5/8"———— 3 1-5/8"3 layer, 1/2" 3 1-5/8"3 layer, 5/8" 4 1-5/8"4 layer, 1/2" 4 1-5/8"4 layer, 5/8" 19 The technical content of this literature is effective 6/25/18 and supersedes all previous information.Pub. No. CD-ProSTUD 6/18 clarkdietrich.com CONNECTIONS Head-of-wall vertical deep leg deflection track systems are required to allow the top of the wall stud to float within the top track legs. This condition allows for vertical live load movement of the primary structure without transferring axial loads to the interior drywall studs. A gap (determined by the Engineer of Record) is required between the top of the wall stud and the deflection track. ProSTUD® Drywall Framing studs can be used with the three Deep Leg Track Systems listed below: (1) WAFER HEAD FRAMINGSCREW IN EACH STUD FLANGE.PLACE IN CENTER OF SLOT. (1) WAFER HEAD FRAMINGSCREW IN EACH STUD FLANGE.PLACE IN CENTER OF SLOT. (1) WAFER HEAD FRAMINGSCREW IN EACH STUD FLANGE.PLACE IN CENTER OF SLOT. (1) WAFER HEAD FRAMINGSCREW IN EACH STUD FLANGE.PLACE IN CENTER OF SLOT. Details shown are for example only. The engineer of record of the project is responsible for the design of the connection to the structure. Additional connection details can be found at clarkdietrich.com. ProTRAK® Deep Leg Track ProTRAK deep leg track is available with leg lengths of 2," 2-1/2" and 3" long. The wall studs are not fastened to the deflection track, and a row of lateral bracing is required within 12" of the deep leg track to prevent rotation and lateral movement of the studs. The deflection track system must be designed for the end reaction of the wall studs (point loads) and for the specific gap required for vertical deflection. Structural Deep Leg Track (18ga & 16ga) Structural Deep Leg Track systems are installed the same as the ProTRAK deep leg track system but are designed to handle tall wall systems. For structural deep leg track allowable loads, contact Technical Services at 888-437-3244 or visit clarkdietrich.com. ClarkDietrich offers both the MaxTrak® Slotted Deflection Track and BlazeFrame® Integrated Fire Stop System. Find more information on these systems at clarkdietrich.com. Slotted Deflection Track from ClarkDietrich The slotted deflection track is attached to the wall studs through vertical slots using wafer head screws, creating a positive connection that allows for vertical movement and also eliminates the requirement for lateral bracing near the top of the wall stud. Deflection track system 2" Leg Trackwith 1/2" Gap 2-1/2" Leg Trackwith 3/4" Gap 3" Leg Trackwith 1" Gap Allowableload (lbs)Limitingwall height Allowableload (lbs)Limitingwall height Allowableload (lbs)Limitingwall height Deflection track system ProSTUD 25 (15mil, 50ksi)ProSTUD 20 (18mil, 70ksi)ProSTUD 30mil (33ksi)ProSTUD 25 33mil (33ksi) Allowable load (lbs)Limiting wall height Allowable load (lbs)Limiting wall height Allowable load (lbs)Limiting wall height Allowable load (lbs)Limiting wall height MaxTrak 30MIL 45 13' 6"76 22' 10"148 44' 4"148 44' 4" MaxTrak 33MIL 52 15' 7"88 26' 5"156 46' 10"156 46' 10" DEEP LEG DEFLECTION TRACK SYSTEMS ProTRAK 25 36 10' 8"24 7' 2"18 5' 4" ProTRAK 20 52 15' 6"34 10' 4"26 7' 9" ProTRAK 30MIL 92 27' 6"61 18' 4"46 13' 9" ProTRAK 33MIL 113 33' 10"75 22' 7"56 16' 11" Complete information on Allowable Loads is available at clarkdietrich.com. Notes: – Limiting wall heights are based on studs spaced at 16" o.c. and an interior lateral load of 5psf. – Stud members must be analyzed independently of the track system. Use www.iProSTUD.com to check limiting wall heights for ProSTUD members. – Stud failure modes relating to the deflection track connection (shear, web crippling, etc.) must be checked separately. Notes: – Allowable loads are based on screws through the slots located 1-1/4" from the track web. – #8 minimum wafer head screws shall be used for stud-track connection. – The above table is applicable to ProSTUD members only. ProSTUD allowable heights must be checked also. – Allowable heights are based on 5psf and wall stud spacing at 16" o.c. with a max. gap of 7/8." ProTRAK® Allowable Lateral Loads and Wall Heights MaxTrak™ Allowable Lateral Loads and Wall Heights 20 Notes: – For unbraced sections, allowable moment is based on 2012 AISI Specification Section C3.1.2 with weak axis and torsional unbraced length assumed to be the listed span (completely unbraced). For mid-span braced sections, allowable moment based on 2012 AISI Specification Section C3.1.2 with weak axis and torsional unbraced length assumed to be one-half of the listed span (bracing at mid-span). – Web crippling calculation based on bearing length = 1 inch. – Web crippling and shear capacity have not been reduced for punchouts. If web punchouts occur near support members must be checked for reduced shear and web crippling in accordance with the 2012 AISI Specification. – Values are for simple span conditions. e Web stiffeners required at support. The technical content of this literature is effective 6/25/18 and supersedes all previous information.The technical content of this literature is effective 6/25/18 and supersedes all previous information. Pub. No. CD-ProSTUD 6/18clarkdietrich.com ALLOWABLE CEILING SPANS Deflection Limit L/240 Deflection Limit L/360 ProSTUD® ALLOWABLE CEILING SPANS ProSTUD ALLOWABLE CEILING SPANS Section Fy(ksi) 4psfLateral Support of Compression Flange 6psfLateral Support of Compression Flange Unsupportedjoist spacing (in) o.c.Mid-spanjoist spacing (in) o.c.Unsupportedjoist spacing (in) o.c.Mid-spanjoist spacing (in) o.c. 12 16 24 12 16 24 12 16 24 12 16 24 162PDS125-15 50 7' 3" 6' 8" 5' 11" 7' 10" 7' 2" 6' 3" 6' 5" 5' 11" 5' 3" 6' 10" 6' 3" 5' 5" 250PDS125-15 50 8' 4" 7' 8" 6' 11" 10' 11" 9' 11" 8' 8" 7' 5" 6' 11" 6' 2" 9' 7" 8' 8" 7' 7" 362PDS125-15 50 9' 2" 8' 6" 7' 7" 12' 9" 11' 8" 10' 3" 8' 3" 7' 7" 6' 9" 11' 3" 10' 3" 8' 11" e 400PDS125-15 50 9' 5" 8' 9" 7' 10" 13' 1" 12' 0" 10' 7" e 8' 6" 7' 10" 6' 11" e 11' 7" e 10' 7" e 9' 3" e 600PDS125-15 50 10' 8"9' 10"8' 10"15' 0"13' 9"12' 2"9' 6"8' 10"7' 11"13' 3"12' 2"9' 11" e 162PDS125-18 70 7' 10" 7' 3" 6' 6" 8' 4" 7' 7" 6' 8" 7' 1" 6' 6" 5' 9" 7' 4" 6' 8" 5' 10" 250PDS125-18 70 9' 0" 8' 5" 7' 7" 11' 9" 10' 8" 9' 4" 8' 2" 7' 7" 6' 9" 10' 3" 9' 4" 8' 2" 362PDS125-18 70 9' 11" 9' 2" 8' 3" 14' 1" 12' 11" 11' 6" 8' 11" 8' 3" 7' 5" 12' 6" 11' 6" 10' 2" 400PDS125-18 70 10' 2" 9' 5" 8' 6" 14' 6" 13' 4" 11' 10" 9' 2" 8' 6" 7' 8" 12' 11" 11' 10" 10' 6" 600PDS125-18 70 11' 10"10' 11"9' 10"16' 10"15' 6"13' 10"10' 7"9' 10"8' 10"15' 0"13' 10"12' 3" 162PDS125-30 33 9' 4" 8' 7" 7' 8" 9' 10" 9' 0" 7' 10" 8' 3" 7' 8" 6' 10" 8' 7" 7' 10" 6' 10" 250PDS125-30 33 10' 4" 9' 7" 8' 6" 13' 8" 12' 5" 10' 10" 9' 3" 8' 6" 7' 8" 11' 11" 10' 10" 9' 6" 362PDS125-30 33 11' 3" 10' 5" 9' 4" 16' 2" 15' 0" 13' 6" 10' 1" 9' 4" 8' 5" 14' 7" 13' 6" 12' 0" 400PDS125-30 33 11' 7" 10' 9" 9' 8" 16' 8" 15' 6" 13' 11" 10' 5" 9' 8" 8' 8" 15' 0" 13' 11" 12' 5" 600PDS125-30 33 13' 1" 12' 2" 10' 11" 18' 11" 17' 6" 15' 8" 11' 9" 10' 11" 9' 10" 17' 0" 15' 8" 14' 1" 162PDS125-33 33 9' 9" 9' 0" 8' 0" 10' 4" 9' 4" 8' 2" 8' 8" 8' 0" 7' 1" 9' 0" 8' 2" 7' 2" 250PDS125-33 33 10' 9" 9' 11" 8' 10" 14' 3" 12' 11" 11' 3" 9' 7" 8' 10" 7' 11" 12' 5" 11' 3" 9' 10" 362PDS125-33 33 11' 8" 10' 9" 9' 8" 16' 8" 15' 5" 13' 11" 10' 5" 9' 8" 8' 8" 15' 0" 13' 11" 12' 6" 400PDS125-33 33 12' 0" 11' 1" 9' 11" 17' 2" 15' 11" 14' 4" 10' 9" 9' 11" 8' 11" 15' 5" 14' 4" 12' 10" 600PDS125-33 33 13' 6" 12' 6" 11' 3" 19' 6" 18' 1" 16' 3" 12' 2" 11' 3" 10' 1" 17' 6" 16' 3" 14' 7" Section Fy(ksi) 4psfLateral Support of Compression Flange 6psfLateral Support of Compression Flange Unsupportedjoist spacing (in) o.c.Mid-spanjoist spacing (in) o.c.Unsupportedjoist spacing (in) o.c.Mid-spanjoist spacing (in) o.c. 12 16 24 12 16 24 12 16 24 12 16 24 162PDS125-15 50 6' 10" 6' 3" 5' 5" 6' 10" 6' 3" 5' 5" 6' 0" 5' 5"4' 9" 6' 0" 5' 5" 4' 9" 250PDS125-15 50 8' 4" 7' 8" 6' 11" 9' 7" 8' 8" 7' 7" 7' 5" 6' 11"6' 2" 8' 4" 7' 7" 6' 8" 362PDS125-15 50 9' 2" 8' 6" 7' 7" 12' 9" 11' 7" 10' 1" 8' 3" 7' 7"6' 9" 11' 2" 10' 1" 8' 10" e 400PDS125-15 50 9' 5" 8' 9" 7' 10" 13' 1" 12' 0" 10' 7" e 8' 6" 7' 10"6' 11" e 11' 7" e 10' 7" e 9' 3" e 600PDS125-15 50 10' 8"9' 10"8' 10"15' 0"13' 9"12' 2"9' 6"8' 10"7' 11"13' 3"12' 2"9' 11" e 162PDS125-18 70 7' 4" 6' 8" 5' 10" 7' 4" 6' 8" 5' 10" 6' 5" 5' 10" 5' 1" 6' 5" 5' 10" 5' 1" 250PDS125-18 70 9' 0" 8' 5" 7' 7" 10' 3" 9' 4" 8' 2" 8' 2" 7' 7" 6' 9" 9' 0" 8' 2" 7' 2" 362PDS125-18 70 9' 11" 9' 2" 8' 3" 13' 9" 12' 6" 10' 11" 8' 11" 8' 3" 7' 5" 12' 0" 10' 11" 9' 6" 400PDS125-18 70 10' 2" 9' 5" 8' 6" 14' 6" 13' 4" 11' 8" 9' 2" 8' 6" 7' 8" 12' 10" 11' 8" 10' 2" 600PDS125-18 70 11' 10"10' 11"9' 10"16' 10"15' 6"13' 10"10' 7"9' 10"8' 10"15' 0"13' 10"12' 3" 162PDS125-30 33 8' 7" 7' 10" 6' 10" 8' 7" 7' 10" 6' 10" 7' 6" 6' 10" 6' 0" 7' 6" 6' 10" 6' 0" 250PDS125-30 33 10' 4" 9' 7" 8' 6" 11' 11" 10' 10" 9' 6" 9' 3" 8' 6" 7' 8" 10' 5" 9' 6" 8' 3" 362PDS125-30 33 11' 3" 10' 5" 9' 4" 15' 11" 14' 6" 12' 8" 10' 1" 9' 4" 8' 5" 13' 11" 12' 8" 11' 1" 400PDS125-30 33 11' 7" 10' 9" 9' 8" 16' 8" 15' 6" 13' 9" 10' 5" 9' 8" 8' 8" 15' 0" 13' 9" 12' 0" 600PDS125-30 33 13' 1" 12' 2" 10' 11" 18' 11" 17' 6" 15' 8" 11' 9" 10' 11" 9' 10" 17' 0" 15' 8" 14' 1" 162PDS125-33 33 9' 0" 8' 2" 7' 2" 9' 0"8' 2"7' 2" 7' 10" 7' 2" 6' 3" 7' 10" 7' 2" 6' 3" 250PDS125-33 33 10' 9" 9' 11" 8' 10" 12' 5"11' 3"9' 10" 9' 7" 8' 10" 7' 11" 10' 10" 9' 10" 8' 7" 362PDS125-33 33 11' 8" 10' 9" 9' 8" 16' 6"15' 0" 13' 2" 10' 5" 9' 8" 8' 8" 14' 5" 13' 2" 11' 6" 400PDS125-33 33 12' 0" 11' 1" 9' 11" 17' 2" 15' 11" 14' 3" 10' 9" 9' 11" 8' 11" 15' 5" 14' 3" 12' 5" 600PDS125-33 33 13' 6" 12' 6" 11' 3" 19' 6" 18' 1" 16' 3" 12' 2" 11' 3" 10' 1" 17' 6" 16' 3" 14' 7" 21 The technical content of this literature is effective 6/25/18 and supersedes all previous information. ClarkDietrich LEED® INFORMATION AND REQUIREMENTS Environmental Product Declarations (EPD) ClarkDietrich, the largest manufacturer of cold-formed steel framing in North America, announced July 2015 a milestone in its ongoing commitment to supplying high-quality, environmentally responsible products. ClarkDietrich received third party- verified ISO-compliant Environmental Product Declarations (EPDs) for its complete steel product portfolio, including its popular ProSTUD® and ProSTUD® with DiamondPlus® Steel Framing Systems. An EPD is a standardized, internationally recognized, comprehensive tool for providing information on a product’s environmental impact. Verified by a third party, information in the document is based on an ISO-compliant Life Cycle Assessment (LCA). This detailed analysis considers all processes in the life cycle of a product, including raw material extraction and refining, energy use and efficiency during manufacture, in addition to transportation methods. Health Product Declarations (HPDs) ClarkDietrich also has Health Product Declarations (HPDs) for its complete steel product portfolio. The HPD Standard is solely a declaration of product content and direct health hazards associated with exposure to its individual contents. ClarkDietrich plant locations: ClarkDietrich LEED Services ClarkDietrich is an active member of the U.S. Green Building Council with LEED® Accredited Professionals on staff. ClarkDietrich is committed to supplying quality products and continually looking for new ways to develop greener building products and sustainable business practices. In total, ClarkDietrich products can help your project qualify for up to: • 7 LEED points under LEED v4 for BD+C • 7 LEED points under LEED 2009 (LEED-NC Version 2.2 and 3.0) LEED® INFORMATION Riverside, CA Sacramento, CA Bristol, CT Dade City, FL Miami, FL McDonough, GA Rochelle, IL Baltimore, MD O'Fallon, MO Warren, OH Vienna, OH Baytown, TX Dallas, TX ClarkDietrich LEED Request Form online at clarkdietrich.com 22 The technical content of this literature is effective 6/25/18 and supersedes all previous information.The technical content of this literature is effective 6/25/18 and supersedes all previous information. Pub. No. CD-ProSTUD 6/18clarkdietrich.com Vienna, OH Baytown, TX Dallas, TX PROSTUD® DRYWALL FRAMING SYSTEM SUPPORT TOOLS clarkdietrich.com Visit to explore company information, design tools, technical documents, services and so much more. Featuring a unique product selector, our website is designed to deliver the details you want with a minimum number of clicks. SubmittalPro® We built this online technical submittal generator tool to make your job easier. Use it to quickly view data on our products and create your final submittal documents. Access SubmittalPro at clarkdietrich.com or on your desktop or smartphone. iProSTUD.com Going mobile? With your smartphone in hand, you can perform a fast, easy search, view ProSTUD limiting heights and even email submittal documents. Architectural Specification Review Over time, project specifications can become outdated. For suggestions on how to improve the performance of your specifications, contact us about a complimentary review at 330-372-5564, ext. 244. Technical Services Count on ClarkDietrich Technical Services to respond to a variety of needs, from general questions on industry standards to specifics on accurate sizing. Call us at 888-437-3244. 23 The technical content of this literature is effective 6/25/18 and supersedes all previous information.Pub. No. CD-ProSTUD 6/18 clarkdietrich.com ClarkDietrich has prepared this literature with the utmost diligence and care for accuracy and conformance to standards. ClarkDietrich intends this information to be accurate, informative, and helpful as a selection guide for choosing ClarkDietrich Building System products. However, this information is only to be used for guidance and is not intended to replace the design, drawings, specifications, and decisions of a professional architect or engineer. ClarkDietrich or its affiliates shall not be responsible for incidental or consequential damages, directly or indirectly sustained, nor for loss caused by application of our products for other than their intended uses. Our liability is limited to replacement of defective products. Claims shall be deemed waived unless they are made to us in writing within thirty (30) days of the date a problem was or reasonably should have been discovered. ClarkDietrich reserves the right to modify or change any information contained in this literature without notification. AISI S100-12 North American Specification for the Design of Cold-Formed Steel Structural Members AISI S220-15 North American Standard for Cold-Formed Steel Framing—Nonstructural Members ASTM American Society for Testing and Materials A1003 "Material specification for steel sheet mechanical and chemical requirements" C645 "Standard Specification for Nonstructural Steel Framing Members" C754 "Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products" C1002 "Standard Specification for Steel Self Piercing Tapping Screw for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs" E119 "Standard Test Methods for Fire Tests of Building Construction and Materials" E72 "Standard Test Methods of Conducting Strength Tests of Panels for Building Construction" E90 "Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements" UL® Underwriters Laboratories testing standard UL 263 "Fire Tests of Building Construction and Materials" Independent product testing and certification Sound ratings: (WEAL) Western Electro-Acoustic Laboratory Fire testing: (UL) Underwriters Laboratories Inc. Multiple UL® design listings for ProSTUD Over 50 UL Designs. See UL file number R26512 for additional information. ProSTUD® & ProTRAK® CODE APPROVALS AND PERFORMANCE STANDARDS ClarkDietrich® ProSTUD Drywall Framing System meets or exceeds these applicable performance standards. USGBC and related logo is a trademark owned by the U.S. Green Building Council and is used by permission. ClarkDietrich is a proud member of the Steel Framing Industry Association (SFIA). Check the updated list of Certified Production Facilities at Architectural Testing's website at www.archtest.com. Additional code approvals SFIA (Steel Framing Industry Association) Intertek CCRR0207. LOCATIONS ClarkDietrich Manufacturing and Sales Locations: CALIFORNIA Riverside P 951.360.3500 F 951.360.3333 CALIFORNIA Sacramento P 951.360.3500 F 951.360.3333 CONNECTICUT Bristol P 866.921.0023 F 860.584.6899 FLORIDA Dade City P 352.518.4400 F 352.518.4450 TEXAS Dallas P 214.350.1716 F 214.350.7252 CLIP EXPRESS℠—East P 866.638.1908 CLIP EXPRESS—West P 530.406.3462 FLORIDA Miami P 800.648.4695 F 305.477.4108 GEORGIA McDonough P 678.304.5500 F 678.304.5555 ILLINOIS Rochelle P 800.659.0745 F 513.645.0750 MARYLAND Baltimore P 410.477.4000 F 410.477.1550 MISSOURI O'Fallon P 888.747.0220 F 636.300.0414 OHIO Warren East P 330.372.5564 F 330.372.4055 OHIO Vienna P 330.372.4014 F 330.372.1945 TEXAS Baytown P 281.383.1617 F 281.573.1679 ClarkDietrich Engineering Services. A full spectrum of solutions. Toll-Free Phone: 877.832.3206Toll-Free Fax: 877.832.3208Technical Services: 888.437.3244Email: engineering@clarkdietrich.com CENTRAL Crown Point, IN NORTHEAST Bristol, CT SOUTHEAST McDonough, GA WEST Carlsbad, CA UL® and UL® Design are service marks of Underwriters Laboratories, Inc. For the complete listing of all Fire and Sound rated assemblies,visit www.clarkdietrich.com/testing-agencies. LEED® Services BUILD GREEN with ClarkDietrich ClarkDietrich is an active member of the U.S. Green Building Council and is committed to supplying quality products that are environmentally responsible. We are continually working to develop greener building products and sustainable business practices. ClarkDietrich steel framing helps contribute points toward LEED® certification. For more details contact Technical Services at 888-437-3244 or visit www.clarkdietrich.com/LEED. 24 The technical content of this literature is effective 6/25/18 and supersedes all previous information. CD-ProSTUD © 6/18 ClarkDietrich The technical content of this literature is effective 6/25/18 and supersedes all previous information. Turn to ClarkDietrich for a complete lineup of steel construction products and services nationwide: Interior Framing∙Exterior Framing∙Interior Finishing∙Clips/Connectors∙Metal Lath/Accessories∙Engineering 9050 Centre Pointe Dr. Suite 400 West Chester, OH 45069 P 513.870.1100 F 513.870.1300 clarkdietrich.comClarkwestern Dietrich Building Systems LLC