Loading...
HomeMy WebLinkAboutEngineer Plans - 2002TDP FNDN, AT EL. 21.8' 19.65' (EXIST) = 19.12 ( 2+% SLOPE) SYSTEM PROFILE ACCESS COVER TO WITHIN 6' OF FIN. GRADE (NOT TO SCALE) j ACCESS COVER (WATERTIGHT) TO 1. MINIMUM .75' OF COVER OVER PRECAST /° WITHIN 6' OF FIN. GRADE PROPOSED 1500 GALLON SEPTIC TANK (H- 10 ) DEPTH OF FLOW = 4 TEE SIZES - INLET DEPTH = t0" OUTLET DEPTH = 14" RUN PIPE LEVEL FOR FIRST 2' I BAFFLE 18,767 1 10" CRUSHED STONE OR MECHANICAL (FACTION. (15.221 I23) (-J-Y. SLOPE) ( 1 7. SLOPE) FOUNDATION- 23' - SEPTIC TANK 11' 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY., DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND. ENGINEER TO INSPECT AND CERTIFY REMOVAL -\ 20.6 LOT 3 \ 11,200± SQ. FT. +z10" OAK + 20.5 + 20.3 2X SLOPE REQUIRED OVER SYSTEM 2' DOUBLE WASHED TEST HOLE LOGS ENGINEER: RICK JUDD, RS 20.0' WITNESS BRUCE MURPHY, RS DATE: 3/8/02 PERC. RATE _ 2 MIN/INCH 0.75' MIN 15z or' CLASS I SOILS P# 3/4' TO 1 1/2' DOUBLE WASHED STONE"' D' BOX 8' LEACHING 5' FACILIT Y USE AI,)J. WATER AT EL. 12.95' (BENCH MARK - TOP OF CONCRETE BOUND. EL. = 20.8' + 20.4 \00 CONC. PATIO / n BLOCKS /J n NO SUNRM r OLc" ,Q EXIST. DWELLING \ TOP FNDN - 21.8' TF s zo 0.1 .6 \ O�� / 4 19.a .�1j 20.0 20.2 / N / 20.3 vF 19.9 ELEV. 0' 20.0' S _PTIC DESTC`I: (.. zRBr'r ^,ISPPS'-R NOT ALLOWED D' -SIGN FLOW: -3 BEDROOMS (110 GPD) = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD ( 2 ) = 660 USE A 1QOQ GALLON SEPTIC TANK LEACHING: SIDES: N/A BOTTOM: 30 x 15 (.74) = 333 TOTAL: 450 S.F. 333 GPD USE 2 ROWS OF (4) STANDARD INFILTRATORS EACH, WITH 3' STONE AT SIDES, 3.3' BETWEEN ROWS AND Z5' AT ENDS -LEGEND 100.0 PROPOSED SPOT ELEVATION l+ 19.6 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - 100 - EXISTING CONTOUR BOARD OF HEALTH D-A=i E MA AP ROVED DAT off 506-362-4541 fax 506 362-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS LOCUS m I MOHtANO N P N SUNSET WALLOW ST. LOCATION MAP NTS ASSESSORS MAP 42 PARCEL 68 WELL: MIW 29 ZONE: A ADJ: 2.7' NOTES: 1, DATUM IS ADIjj2n`JI1E /S TI-� rt,'O i '.JA✓ MAP 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8' PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASH D H-10-- 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6, CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS, ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. PUMP & REMOVE (OR FILL W/CLEAN SAND) EXISTING CESSPOOL(S, TITLE 5 SITE PLAN OF 32 MORNING DRIVE IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: WILLIAM MATHESON 20 0 20 40 60 SCALE: 1" = 20' DATE: MARCH 14, 2002 RECERVIED APR 16 2002 HEALTH DEPT. I y�62lo� FILL 2" A/E LS 9.1 1 OYR 3/2 BW LFS 10YR 5/6 26" 17 C F -M 2.5Y 6/4 117' OBS WATER 1 .25' 129" 9.25 S _PTIC DESTC`I: (.. zRBr'r ^,ISPPS'-R NOT ALLOWED D' -SIGN FLOW: -3 BEDROOMS (110 GPD) = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD ( 2 ) = 660 USE A 1QOQ GALLON SEPTIC TANK LEACHING: SIDES: N/A BOTTOM: 30 x 15 (.74) = 333 TOTAL: 450 S.F. 333 GPD USE 2 ROWS OF (4) STANDARD INFILTRATORS EACH, WITH 3' STONE AT SIDES, 3.3' BETWEEN ROWS AND Z5' AT ENDS -LEGEND 100.0 PROPOSED SPOT ELEVATION l+ 19.6 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - 100 - EXISTING CONTOUR BOARD OF HEALTH D-A=i E MA AP ROVED DAT off 506-362-4541 fax 506 362-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS LOCUS m I MOHtANO N P N SUNSET WALLOW ST. LOCATION MAP NTS ASSESSORS MAP 42 PARCEL 68 WELL: MIW 29 ZONE: A ADJ: 2.7' NOTES: 1, DATUM IS ADIjj2n`JI1E /S TI-� rt,'O i '.JA✓ MAP 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8' PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASH D H-10-- 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6, CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS, ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. PUMP & REMOVE (OR FILL W/CLEAN SAND) EXISTING CESSPOOL(S, TITLE 5 SITE PLAN OF 32 MORNING DRIVE IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: WILLIAM MATHESON 20 0 20 40 60 SCALE: 1" = 20' DATE: MARCH 14, 2002 RECERVIED APR 16 2002 HEALTH DEPT. I y�62lo�