HomeMy WebLinkAbout2021 Sign Off Transmittal - 2nd FL Loft24' - 6'
2-T, 10'-91
2436 2436 2436
4! - 7" T
0
� REFRIG. , M
M
DINING ROOM & BEDROOM 2436
2436 KITCHEN
50
14' 611'2- - 9-7„ �
2' -11 - —
�o 0
OVEN&RANGED CEILING HT. T-8"
2436
SINK �
HOT WATER
V° HEATER
_ 2666
-117 /2"—'�L--i U-91 0'
G - 2436
2666 a 2666
HALL B HROOM
i
i
- - - i 2428 o
N f7
2436 .f i
2436
4! - a' 1T i- 4^
LIVING ROOM
UNDERSIDE OF
STORAGE PEAK OF ROOF
STUCTURE ABOVE.
/ PEAK @ 9'-4" AFF
2666 CEILING
21034 HEIGHT 8'-10" 21034
DOUBLE SLOPED
o STUD, TYP. - ENCLOSED PORCH CEILING
N
io
21034I CEILING 21034
HEIGHT T-2"
21034 21034 2666 21034 21034
EXISTING FLOOR PLAN
l 1" ) SCALE: �./4" = 1'-0"
I
SKYLIGHT
SCALE: 1/8" = 1'-0"
SHIP'S LADDER UP
TO WIDOW'S WALE'
t
II,
I
Second Floor Plan
SCALE: 1/8" _ T-0"10
--
TIMBER COLUMN, TYP.
GUARDRAIL, TYP.
002- 2
a,
003/
1
DECK
1
002
First Floor Plan
SCALE: 1/8" = 1'-0"
EXISTING CESSPOOL
70 BE PUMPED, FILLED WITH
SAND AND ABANDONED.
WORK LIMIT(TYP.)—
FUTURE AD
n
1 � t�E�FFFV 2
PROPOSED S.A.S. �
6 ROWS OF 5 Arc36 HC HD UN
ON SAND WITH STONE BETWEEN
VENT—
INSPECTION PORT.
9907
h. OVERGROWN CRANBERRY BOG
(WATER SURFACE OF BOG, EL.=86.9)
86.90 87,66
z_
88.42
x
88.93 88.98 88.55
89.06
92.14
9251
96.60 x - t 94.91
SPIKE
96.32
x S )2o462g _ +9595
67_ F
t 6+91 .*� .4r,y�0 ,,� . ®•
x 97112•--"- 97.04.
96.82I EXISTING.-�
97.43"HOUSE(17) PROVIDE NEW
Ix LO F 96 9+ SEWER O�UTLEI
� I 97 04
PORCH
J /nn ^x 9 /� ;s[--'
h
f
f
r
99.62
_ 9763 O
/10
� O
+�9B..//$" /
( ° x 100,08 O
�5/
�e c
100.62
x
5
PROPOSED
SEPTIC TANK
/ (o I O
:n
v
3.�
SLEEVE. SEWER AT
WATER SERVICE CROSSING
999
7T T - 5
1 </`6J�i T it
BENCHMARK loo oa
(V 1 MAG NAIL SET
0000
PLAN REFERENCE: PLAN BK 83 PG 45
BUILDING LOCATION TAKEN FROM REFERENCE PLAN
AND VERIFIED BY INSTRUMENT SURVEY
PARCEL
, R , •
HEALTH r;'—�PT
I
PLAfU REVISION 5/17/21
1) r�OVE PROPOSED TANK LOCATION
2) ELIMINATE VARIANCE 1
3) 1 CREASE VARIANCE 4
OWNER OF RECORD
McNAMARA, BRENDAN F
230 RANCHO SANTA FE RD
54 ENCINITAS, CA 92024
5, ALL ELEVATIONS BASED ON AN ASSUMED DATUM.
6, THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.AS.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3),
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
7 TRENTON STREET, SOUTH YARMOUTH, MA
Prepared for: Brendan McNamara, 230 Rancho Santa Fe Rd, Encinitas, CA 92024
Engineering by: SCALE DRAWN JOB. NO.
Engineering Works, Inc. 1"=20' P.T.M. 331-20
12 West Crossfieid Road, Forestdole, MA 02644 DATE CHECKED SHEET N0.
(508) 477-5313 2/27/21 P.T.M. 1 Of 2
-- 55,--- EXISTING CONTOUR LOCUS
x 50 98 EXISTING SPOT GRADE
A,' ---- EXISTING WATER SERVICE "'� ao:ono se
N
G— EXISTING WATER SERVICE
aimmm St
OVERHEAD WIRES
4
® TEST PIT a
BENCHMARK o
m
_<._ WETLAND SYMBOL
LEGEND Lewis a o
St L
m
Ralway BWMs red 5Om°tz 2
Bay
a
Pok st
ro
a
LOCUS MAP
r
NOT TO SCALE
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
�..
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
KITCHEN
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
BED RM
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED. BELOW:
-310 CMR 15 405(1)(a)&(b) LOCAL UPGRADE APPROVAL
ENT.: HALL LOFT/
BATH
1)--A ao is ,ee, sejptc�e te 5;QePF&Pef:-} 19- <,�-tea,-a-S' sese �aek.
2) A 3 variance S.A.S. to property line (side), .for a 7' setback.
BED RM.
q
3) A 3" variance. S.A.S. to property line (front), for a 7' setback,
4) A 2' variance, septic tank to cellar wall, for an 8' setback.
LIVING RM
5) A 3' variance, SAS, to cellar wall, for a 17' setback.
�Jy, h
6) A 2'. variance to the maximum cover requirement of 3' over
the S.A.S. for up to 5' of cover over the S.A.S.
PORCH
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
I
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
FIRST FLOOR SECOND FLOOR
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
FLOOR PLAN
}
ENGINEER BEFORE CONSTRUCTION CONTINUES.
HEALTH r;'—�PT
I
PLAfU REVISION 5/17/21
1) r�OVE PROPOSED TANK LOCATION
2) ELIMINATE VARIANCE 1
3) 1 CREASE VARIANCE 4
OWNER OF RECORD
McNAMARA, BRENDAN F
230 RANCHO SANTA FE RD
54 ENCINITAS, CA 92024
5, ALL ELEVATIONS BASED ON AN ASSUMED DATUM.
6, THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.AS.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3),
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
7 TRENTON STREET, SOUTH YARMOUTH, MA
Prepared for: Brendan McNamara, 230 Rancho Santa Fe Rd, Encinitas, CA 92024
Engineering by: SCALE DRAWN JOB. NO.
Engineering Works, Inc. 1"=20' P.T.M. 331-20
12 West Crossfieid Road, Forestdole, MA 02644 DATE CHECKED SHEET N0.
(508) 477-5313 2/27/21 P.T.M. 1 Of 2
NOTE: TO PREVENT BREAKOUT, THE PROPOSED
FINISH GRADE SHALL NOT BE < EL.=95.03
FOR A DISTANCE OF 15' AROUND THE
SEPTIC.. TANK PERIMETER of THE S.A.S.
INSTALL. RISERS & COVERS OVER INLET & PROPOSED D -BOX PROPOSED S.A.S.
OUTLET AND SET TO 6" OF FINISH GRADE
INSTALL RISER & WATERTIGHT INSTALL 1 INSPECTION PORT(MIN.) CHARCOAL VENT
FF EL=97.8± COVER SET TO 6 OF GRADE AT END OF S.A.S. (CONNECT ALL ROWS) ti
TOP EL=96.9± a' /EXISTING
F.G. EL.=96.6± F.G. EL.=9810 t0 99.6± HOUSE(17)
F.G. EL.=97.4± F.G. EL.=98.0± I f `0 0 70 F=96.9+ MAINTAIN 2%'. GRADE (MIN.) OVER S.A.S. MCb(varies)(
L 17' XI0.0M N'IAIXI-
0 5=19 (MIN.) L= 12' L= 8' INSPECTION PORT a 0
4"SCH40 PVc ®s=1% (MIN.) ONE MIN. A)' 9'
TOP OF TANK -95.85 4"SCH40 PVC ® SCH4 (MIN.) (MIN.) TD
4"SCH40 PVC PORCH
1O' 6 .75" TO =32.3'
a4" LIQUID LEVEL ° 10INVERT
GAS BAFFLE INV.=94.87 PROPOSED IN =94.70 6 ROWS OF 5 UNI S AT 5.0'/UNIT) = 25.0' /�✓
BOTT. of TANK=91.31 INV.=95.00 D -BOX SYSTEMSOIL1 j 10,
i
PROPOSED 1500 GALLON SEPTIC TANK IN =94.60
INFILTRATOR IM1530 GALLON PLASTIC TANK /
INV.=95.25 ADS BIAXIAL GEOGRID / BX114GG OR EQUAL
PLACED 5"1 to 6" ABOVE FILTER FABRIC /
CONNECT TO EXISTING SEWER EXTENDGEOGRID FOR 2' ON ALL SIDES OF UNITS /
AT HOUSE, INV. =9 6.1 (VERIFY) ESTABLISH VEGETATIVE COVER
NOTE: STONE BETWEEN. CHAMBERS IS CLEAN NATIVE BACKFILLIJ, �� PROPOSED S.A.S.
FOR AIR MOVEMENT & STRUCTURE F)LACE 1"to 3/4" f DOUBLE WASHED STONE 6 ROWS OF 5 Arc36 HC HD UNITS
NOTES: TWF,EN CHAMBERS TO TOP OF UNITS ON SAND WITH STONE BETWEEN
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE,;: .o. .,,.,
INVERTS, PRIOR TO INSTALLATION. BREAKOUT=TOP y;.„, "' ' "'`�
TOP ELEV.=95.03
2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND INV. ELEV'-94.60 L 6"
TRUE TO GRADE ON A MECHANICALLY COMPACTED S.A.S. LAYOUT
SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN BOTTOM. ELEV.--93.70
310 CMR 15:221(2). 2.83' PLACE APPROVED
3) INSTALL INLET & OUTLET TEES AS REQUIRED. 5' MIN. ABOVE' ESTIMATED FILTER FABRIC
4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE-. HIGH GROUNDWATER 'EFFECTIVE WIDTH=17.0 OVER STONE
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.. EXISTING SUITABLE .63,5"
5) SEPTIC TANK SHOULD NEVER BE EMPTY AT TIMES ADJUSTED G.W., EL=88.5 - .MATERIAL
OF ANTICIPATED FLOODING. 'I
USE 6 ROWS OF 5 -ADS Arc 36 HC HD UNITS WITH NO Ib'
SEPTIC SYSTEM PROFILEBETWEEN EACH ROW
TYPICAL SECTION 33.8" '
DESIGN CRITERIA SOIL LOG
SOIL TEXTURAL0 BEDROOMS: 00 5: 2CLBAEDS 62021 TOP VIEW
ODMS WITNESS: MALLORY LAN
DATE: JANUARY , J�
SOIL EVALUATOR: 'CHRtS McENTEE PE, 5E-14092
GLER HEALTH AGENT 60"
DESIGN PERCOLATION RATE: <2 MIN/IN T I END CAP END CAP VIEW SIDE VIEW
ELEV. DEPTH FRONT
DAILY FLOW: 220 GPD 99.3 0' END CAP
DESIGN FLOW: 330 GPD ASANDY (LOAM REAR/TOP VIEW
GARBAGE GRINDER: NO-S.A.S.. IS NOT DESIGNED FOR GARBAGE GRINDER 98.5 10YR /3 70" NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT SIDE VIEW
LEACHING AREA REQUIRED' (330 GPD) = 445.9 SF B TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY
LOAMY SAND DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE.
74 GPD/SF 10YR 5/6 4640 TRUEMAN BLVD
PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY 96.5 C 3a Ems. HILLIARD, OHIO 43026 Are 36 HC DETAIL /u 11 lyrA\
INFILTRATOR IM1530 GALLON PLASTIC TANK ' PERO O CED DwxecE 5Y9reMS. ING. .UNITS MUST BE STAMPED HD
PROPOSED D -BOX: 1 INLET, 5 OUTLET (MINIMUM), H-20 RATED.. MED. SAND PROPOSED SEPTIC SYSTEM UPGRADE PLAN
USE 6 ROWS OF 5 -ADS Arc 36 HC HD UNITS WITH NO 1OYR $/a
STONE AND NO SEPARATION BETWEEN EACH ROW 86.5 ADJ. dW _ 7 TRENTON STREET, SOUTH YARMOUTH, MA
BOTTOM AREA: (GENERAL ,USE APPROVAL FOR 4.80 SF/LF OF UNIT) 89.1 silk. n;w« 22". Prepared for: Brendan McNamara, 230 Rancho Santa Fe Rd, Encinitas, CA 92024
(Arc36 Units) 30 UNITS x 5.0 LF x 4.80 SF/LF = 720.0 SF PERC RATE 2 MIN/I�("C HORIZON) Engineering by: SCALE DRAWN JOB. NO.
TOTAL AREA = 720.0 SF No GROUNDWATER EB, ELEDRTEED
WATER SURFACE OF BOG, Engineering Works, Inc. N.T.S. P.T.M. 331-20-
'DESIGN FLOW PROVIDED: 0.74 GPD/SF(72C.0 SF) = 532.8 GPD *WATER LEVEL IN BMONITORING, EL. -86.5 72 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO.
NOMINAL BOTTOM AREA = 17'. x 25' = 425 SF 400 SF MIN, RECOMMENDED INDEX WELL MIW 29 WAT R LEVEL 8.7 JAN 2021
ZONE A ADJUSTMENT = .0', EST. HIGH GW -88.5 (508) 477-5313 2/27/21 P.T.M. 2 of 2