HomeMy WebLinkAboutEngineer Plans - 2021LEGEND 99'-- EXISTING CONTOUR X 99'7 EXIST. SPOT ELEV. —[99]— PROPOSED CONTOUR [98.4] PROPOSED SPOT EL. T,.H I INSPECTION PORT (SEE DETAIL) TEST HOLE 2% SLOPE OF GROUND CCD UTILITY POLE s`U FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM EA W DCE #64-286 PRECAST H-10 RISERS (TYP.) SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE -------- - — IO.O' MINIMUM .75' OF COVER OVER PRECAST _ W 9.42' Q 10" EXISTING 14" TEE SEPTIC TANK** TEE 8.09±'* a GAS BAFFLE o Q 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) (__L_% SLOPE) FOUNDATION— EXIST. —SEPTIC TANK 7' PUMP CHAMBER **INSTALLER SHALL CONFIRM MINIMUM *THE INSTALLER SHALL VERIFY THE SEPTIC TANK SIZE AT MIN. 1000 LOCATIONS OF ALL UTILITIES AND ALL GALLONS AND ITS SUITABILITY FOR BUILDING SEWER OUTLETS AND RE -USE. REPLACE WITH 1500 ELEVATIONS PRIOR TO INSTALLING ANY GALLON SEPTIC TANK APPROPRIATE TO PORTION OF SEPTIC SYSTEM SITE CONDITIONS IF NOT SUITABLE ..... _ ... 4"44SCH40 PVC TEE... PIPES LEVEL 1ST 2' 6" MIN. SUMP " g 12" MIN.. INT. DIM. 10.02' 9. 5' 1 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 (23) (-i-% SLOPE) 6' D' BOX 5' - OF 310 CMR 15.255(3)' O I MARK CORNERS OF VERIFYING THE LOCATION OF ALL UNDERGROUND & LEACHING FIELD W/ SCALE 1"=2000'± REBAR SET 4" BELOW 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL GRADE INSPECTION PORT (SEE DETAIL) ALARM ON FLOAT SWITCH 2% SLOPE 12. EXISTING LEACHING FACILITY SHALL BE PUMPED PANEL #25001CO588J DATED 7/16/2014 _ FILTER FABRIC 8.33' 11.0' TOP 10.13' - FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ. 8 - IS SUITABLE FOR PUMP CONNECTION PRIOR TO ORDERING PUMPS. ELECTRICAL PERMIT REQUIRED. ocus 14. NO SUMP PUMP DISCHARGE NEAR SAS ALLOWED DESIGN FLOW: 3 BEDROOMS 0 110 GPD = 330 GPD yCLEAN FILL VARIANCES REQUESTED: - o o 4' PERFORATED PVC 3' O.G. $=U. OO5) --� SEPTIC TANK: 330 GPD (2) = 660 3/4"-1-1/2" DOUBLE WASHED o 8 STONE LEACHING. FIELD ° 6"DEPTH MIN BELOW INV. ' 15'X30'= 450 SF OK LEVEL BOTTOM 0 o 9.65' O� GL0 30.0' 9.15' LEACHING FACILITY ADJ. G.W. EL.= 5.15' 1 G.W AT EL.= 2.5' _ k ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP PROP. WATERTIGHT COVER TO GRADE PROVIDE QUICK DISCONNECT FOR PUMP 10.0' NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND. PERMISSION OBTAINED FROM BOARD OF HEALTH. 10, CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND LOCUS ��� VERIFYING THE LOCATION OF ALL UNDERGROUND & "/� NO LOW POINTS 450 SF X .74 = 333 GPD OK OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000'± WORK. 2" PRESSURE LINE USE A 15' X 30' PIPE AND STONE LEACHING FIELD 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 24 PARCEL 121 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE AE ALARM ON FLOAT SWITCH (EL. 11 FEET) AS SHOWN ON COMMUNITY 12. EXISTING LEACHING FACILITY SHALL BE PUMPED PANEL #25001CO588J DATED 7/16/2014 AND REMOVED OR PUMPED AND FILLED WITH CLEAN 8.33' SAND. SYSTEM DESIGN: 13. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM 8 - IS SUITABLE FOR PUMP CONNECTION PRIOR TO ORDERING PUMPS. ELECTRICAL PERMIT REQUIRED. ocus 14. NO SUMP PUMP DISCHARGE NEAR SAS ALLOWED DESIGN FLOW: 3 BEDROOMS 0 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW VARIANCES REQUESTED: - o (1h): REDUCTION IN SEPARATION TO G—W, 5' TO 4.0' SEPTIC TANK: 330 GPD (2) = 660 **RE -USE EXISTING 1500 GAL. SEPTIC TANK USE 1000 GAL. H-10 PUMP CHAMBER LEACHING: 330 GPD (.74) = 446 SF REQUIRED 15'X30'= 450 SF OK m O� GL0 Q 0 Lewis �. Pond Rop;o 10, CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND LOCUS ��� VERIFYING THE LOCATION OF ALL UNDERGROUND & "/� NO LOW POINTS 450 SF X .74 = 333 GPD OK OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000'± WORK. 2" PRESSURE LINE USE A 15' X 30' PIPE AND STONE LEACHING FIELD 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 24 PARCEL 121 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE AE ALARM ON FLOAT SWITCH (EL. 11 FEET) AS SHOWN ON COMMUNITY 12. EXISTING LEACHING FACILITY SHALL BE PUMPED PANEL #25001CO588J DATED 7/16/2014 AND REMOVED OR PUMPED AND FILLED WITH CLEAN 8.33' SAND. SYSTEM DESIGN: 13. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM 8 - IS SUITABLE FOR PUMP CONNECTION PRIOR TO ORDERING PUMPS. ELECTRICAL PERMIT REQUIRED. GARBAGE DISPOSER IS NOT ALLOWED 14. NO SUMP PUMP DISCHARGE NEAR SAS ALLOWED DESIGN FLOW: 3 BEDROOMS 0 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1h): REDUCTION IN SEPARATION TO G—W, 5' TO 4.0' SEPTIC TANK: 330 GPD (2) = 660 **RE -USE EXISTING 1500 GAL. SEPTIC TANK USE 1000 GAL. H-10 PUMP CHAMBER LEACHING: 330 GPD (.74) = 446 SF REQUIRED 15'X30'= 450 SF OK INV. IN 8.02' rl-1 "/� NO LOW POINTS 450 SF X .74 = 333 GPD OK 1000 GAL. H-10 S/T 2" PRESSURE LINE USE A 15' X 30' PIPE AND STONE LEACHING FIELD 330 GAL.+ LS SLOPE TO DRAIN BACK TO PC ALARM ON FLOAT SWITCH RESERVE 20" SETTINGS: PUMP ON 8.33' 0.25" WEEP HOLES CHECK VALVE TEST HOLE LOGS 8 LS 4" WORKING RANGE 1OYR 7/4 32" MYERS SRM 4 4, SUBMERSIBLE 4/10 HP PUMPENGINEER: CRAIG J. FERRARI, SE #13871 8" SYSTEM (OR EQUAL) 000 000000 _ WITNESS: MALLORY LANGLER PUMP CHAMBER DATE: 4/28/21 (NOT TO SCALE) PERC. RATE _ < 2 MIN/INCH WATERPROOF/WATERTIGHT . _ _ i ... - CLASS I SOILS- L_ ELEV. 1 n" 10.0' 0 r i i 25 50 75 100 CAPACITY — GPM PUMP CURVE FOR MYERS SRM4 4/10 HP PUMP Permit valid for REPAIR OF SEPTIC. SYSTEM ONLY, due to State and Local septic variances. Board of Health review and approval is required for any future additionstrenovations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department APPROVED Sr? --'V 1`64$` T Cte zr a -f Name Date BED I.BATH IKITCHEN BREEZEWAY GARAGE BED BED z LIVING ROOM DINING FLOOR PLAN NOT TO SCALE f PEf GROUNDWATER ADJ. DATA: WELL: MW 29 ZONE: B ADJUSTMENT: 2.65' (MARCH) 120" G.W. ENCOUNTERED AT 90" EL.=2.5' TITLE 5 SITE PLAN OF ��P1,SH OF M,gss9c W o� DANIEL tiv o A. OJALA ., No. 40980 i 0' Fss\oa DATE DANIEL A. OJALA, P.E., P.L.S. DANIEL A. OJALA No.40980 50 PAMET ROAD EST YARMOUTH. MA JUL 1 5 1021 = I ALS T. PREPARED FOR ERIC TOMASINI DATE: MAY 6, 2021 off 508-362-4541 fax 508-362-9880 downcape.com down cope engineering, Inc. civil engineers land surveyors 939 Main Street ( Rte 5A) YARMOUTHPORT MA 02675 04-286 TOMASINI.DWG. I FILL 15" A LS 1OYR 5/1 20" 8.33' B LS 1OYR 7/4 32" 7.33' C C MS 2.5Y 8/3 0.0' GROUNDWATER ADJ. DATA: WELL: MW 29 ZONE: B ADJUSTMENT: 2.65' (MARCH) 120" G.W. ENCOUNTERED AT 90" EL.=2.5' TITLE 5 SITE PLAN OF ��P1,SH OF M,gss9c W o� DANIEL tiv o A. OJALA ., No. 40980 i 0' Fss\oa DATE DANIEL A. OJALA, P.E., P.L.S. DANIEL A. OJALA No.40980 50 PAMET ROAD EST YARMOUTH. MA JUL 1 5 1021 = I ALS T. PREPARED FOR ERIC TOMASINI DATE: MAY 6, 2021 off 508-362-4541 fax 508-362-9880 downcape.com down cope engineering, Inc. civil engineers land surveyors 939 Main Street ( Rte 5A) YARMOUTHPORT MA 02675 04-286 TOMASINI.DWG. I