Loading...
HomeMy WebLinkAboutEntineer Plans - 20215 FT. SOIL REMOVAL (NOTE 18) ' I i I 120.00 i 49.7 49.5LOT 18 i U+ 1- AREA=0.34 ACRES 11.32 'i 11 o ° i 1 N � (T S 49. 0 49.6 /p 33.29 V, I T •p F @ c o Et, 50-0 o EXIST. 1,50OG _w SEPTIC TANK -79- 49,G 1 49.7 _ ---- ---- ---- DRIVEWAY I I 1 1 1 1 1 1 1 49.5 49.7 TBM = EL. 50.0 BULKHEAD FOUNDATION LEGEND �--�� PROPOSED CONTOUR ® PROPOSED SPOT GRADE -- gg -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE —W— EXISTING WATER SERVICE ® TEST PIT SCALE: 1" = 20' Permit valid for REPAIR OF SEPTIC SYSTEM. ONLY, due to State and Local septic varlraces. Board of Health review and approval is required say. future additionstrenovatiouslalterstinm to $*wage facilities and/or structures/dwelling. Yarmouth Health Department APPROVED n.r►e oNe SEP 0 a 2021 HEALTH DEPT �ytH OF 0 STEVEI $ RUM6 -a f`iP• 352 SURVEY BY: WELLER AND ASSOC. WEST YARMOUTH LOCUS 14 SILVER LEAF LN, LOCUS MAP LOCUS INFORMATION PLAN REF: D803853 TITLE REF: C158154 PARCEL ID: MAP 062 PAR. 041 PROPETY IS IN ZONE II FLOOD ZONE: NOT IN FLOOD ZONE 0 O 0 A SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 61 ADAMS ROAD WEST YARMOUTH, MA PREPARED FOR LEONA NICKERSON/ READY ROOTER EXC. AUGUST 25, 2021 REV: SEPTEMBER 7. 2021 OF D REN M X4Q 1 r\ MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle50gmail.com SHEET 1 OF 2 J#1697 NOTE. MAGNETIC TAPE TO BE PLACED OVER ALL COVERS ,SEPTIC TANK SILL EL.=50.0t INSTALL RISERS & COVERS OVER INLET & PROPOSED -L --BOX OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & COVER INSTALL LOCKING COVERS IF AT FINISH GRADE SET TO 6" OF GRADE F.G. EL.=49.61 /-F.G. EL.=49.601 /- F.G. EL: 49.60f - - - - - --- ---------- 9" MIN COVER/ 36" MAX COVER L = 20' L = 10'(MAX) 0 S=196 (MIN.) ELs48.81t O S=1% (MIN.) 0 S=I% (MIN.) 4"SCH40 PVC 4"SCH40 PVC 4"SCH40 PVC ®+INV.=47.81 1IY 14` 6 11.3" TO 48" uoUID INV=47INVERT LEVEE ..56 INV.=47.09 - GAS BAFFLE PROPOSED INV.=47.19 INV.=47.36 DB_5 EXIST. 1.500 GALLON SEPTIC TANK EXIST. SEWER OUTLET NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. 2) D -BOX SHALL BE SET TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL PVC INLET/OUTLET TEES IN SEPTIC TANK AS REQUIRED, 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. BREAKOUT=TOP ELEV.=47.48 INV. ELEV.= 47.09 BOTTOM ELEV.= 46.15 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:47.48 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL A 4" DIAMETER INSPECTION PORT OVER ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. /-F.G. EL- 49.7 (MAX.) 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. (5.05' PROVIDED) ADJ. GROUNDWATER: EL: 41.10 - INSTALL TWO INSPECTION PORTS (MIN.) 4 ROWS OF 4 UNITS AT 6.25'/UNIT = 25'/ROW SOIL ABSORPTION SYSTEM (PROFILE) VEGETATIVE COVER 1 WITH CLEAN FERC SAND EXISTING SUITABLE 2,83' MATERIAL EFFECTIVE WIDTH = 4 x 2.83' = 11.32' USE 4 ROWS OF 4 -HIGH CAPACITY tNFILTRATOR (H20) UNITS k 4F�ss' �y DARREN M. YER Nt, SEPTIC SYSTEM N.T.S. PROFILE �► TYPICAL SECTION ILM SOIL LOGS DESIGN CRITERIA DATE: JULY 21, 2021 NUMBER OF BEDROOMS: 2 BEDROOM DWELLING SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 DESIGN FLOW: RESIDENTIAL: 2 BEDROOMS 0 110 GPD/BR = 220 GPD WITNESS: PHIL RENAUD, YARMOUTH HEALTH DEPT. DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) GARBAGE GRINDER: NO (not designed for garbage grinder) Elev. TP -1 Depth DISTRIBUTION BOX: USE DB -5 (H20) 49.60 A 0' LO SAND SEPTIC SEPTIC TANK: 220 gpd x 200% = 440 gpd USE EXISTING 1,50OG SEPTIC TANK MY 48.78 10" B LEACHING AREA REQUIRED: (220)/.74 = 297.29 S.F. LOAMY SAND 1OYR 5/8 PRIMARY S.A.S. 45.93 USE 4 ROWS OF 4 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) SANDM (CHAMBER) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473 SF 2.5Y 7/3 TOTAL AREA = 473 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(473SF) = 350 GPD > 220 GPD 37.60 1 144" req'd PERC RATE <2 MIN/IN. ("C" HORIZON) GROUNDWATER OBSERVED AT 144". EL 37.60 WELLAIW--230 ZONE: E LEVEL' 23.50 ADJ: 4.5 ADJUSTED GROUNDWATER O EL 42.10 USE YARMOUTH BOH ALLOWED 1 FT REDUCTION, ADJUSTED GROUNDWATER OF EL 41.10 ` I. Darren M. Meyer, R.S.. CSE, hereby certify that i am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that 1 have passed the Soil Evol. Exam in October, 1999. GENERAL NOTES: I• ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE PNIAPMTHBE LTDDO OOINSECTIIOAND APPROVAL BY E BBOARD OFF HEALTH AND DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWELLING IS SERVICED BY MUNICIPAL WATER. B. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 O 1/8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. INSTALLER TO VERIFY ALL OUTLETS PRIOR TO INSTALLATION. 18. REMOVE ALL UNSUITABLE SOILS 5FT AROUND LEACHING TO EL. 45.93 OR TOP OF "C" LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. 19. PROPERTY IS LOCATED WITHIN A ZONE 11, NO INCREASE IN FLOW ALLOWED. mc TIN 11" J INVERT HEIGHr END CAP INFILTRATOR - HI CAPACITY (H20) CHAMBER PROPOSED SEPTIC SYSTEM UPGRADE PLAN 61 ADAMS ROAD, WEST YARMOUTH, MA Prepared for: Nickerson/Ready Rooter Exc. System Design and Site Plan by. SCALE DRAWN DATE MEYER & SONS, INC. N.T.S. DMM 08/25/21 PO BOX 981 EAST SANDWICH, MA 02537 REV. DATE CHECKED SHEET N0. 508-3s22922 09/07/21 DMM 2 of 2