Loading...
HomeMy WebLinkAboutEngineer Plan - 200410.27' SYSTEM PROFILE TOP FNDN. AT EL. TEST HOLE LOGS . , 9.7 ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) PROVIDE INSPECTION PORT WITHIN ACCESS COVER (WATERTIGHT) TO / 6" OF FINISH GRADE ENGINEER: RICK JUDD, RS 10.0 MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM / AMY VON HONE, RS 11 2 WITNESS: * mr, 2" DOUBLE WASHED PEASTONE 1,2/11/03 DATE: 1:.1 aQZ�` RUN PIPE LEVEL * wFOR FIRST 2' 10.4' PERC. RATE< 2 MIN/INCH 7.8' PROPOSED 11500 p/GALLON SEPTIC 75'Ile y 7, 0' TANK (H- 10GAS �09.98'CLAS$ SOILS P#' WATERPROOF BAFFLE10.22' 10.05' 5205� 0.58' MIN 0025$ o SLOPE) �6" CRUSHED STONE OR MECHANICAL c 9 4 4 ELEV. DEPTH OF FLOW = 4 COMPACTION. (15.221 [21) p° 9.8' TEE SIZES: MIN (� % SLOPE) 3/4" TO 1 1/2" DOUBLE WASHED STONE AP INLET DEPTH - 10 ( 1 % SLOPE) SL OUTLET DEPTH = 14 5' 1, 10YR 3/2 FOUNDATION - 34 - SEPTIC TANK 11' PUMP 9' - D' BOX 9' LEACHING 6 16 CHAMBER FACILITY Bw USE OBSERVED WATER AT EL. 4.4' ASSESSORS MAP 29 PARCEL 70 *THE INSTALLER SHALL VERIFY THE (TIDALLY INFLUENCED) LCS LOCATIONS OF ALL UTILITIES AND ALL VARIANCES REQUESTED UNDER MAX. FEASIBLE 6 COMPLIANCE 15.405: ALARM AND CONTROL PANEL lOYR 4 BUILDING SEWER OUTLETS AND ELEVATIONS / to: REDUCTION IN SETBACK, SAS To LOT LINE (10' TO PRIOR TO INSTALLING ANY PORTION OF TO BE ,taSTAL1.En I4SrDE .� 16" 8.4' a'), ST TO LOT LINE (10' TO 9') SEPTIC SYSTEM BUILDING. ALARM TO BE ON INV. IN 6.6' ib: REDUCTION IN SETBACK, SAS TO FOUNDATION (20'TO 14' ST TO FOUNDATION 70' TO 8' SEPARATE CIRCUIT FROM PUMP A ): ( ) 1000 GAL. H-10 S/ 2" PRESSURE LINE ]I: REDUCTION IN SEPARATION TO GROUNDWATER, 5' TO ALARM ON 700 GAL.+ SLOPE TO DRAIN BACK TO PC C 4' Id: 25% REDUCTION IN SAS SIZE REQUESTED BUOYANCY CALCS: FLOAT SWITCH RESERVE WEEP HOLE SETTINGS PUMP ON CHECK VALVE TOWN OF YARMOUTH REG. 3.7: 1500 GAL H-10 ST WGT. 11480 LBS (SHOREY) 4' WORKING RANGE B. - M C REDUCTION IN SETBACK, SAS TO WETLAND / 5.67 x 10.5 x 2.48 x 62.4 = 9213 UP (OK) 4, ZOELLER 'WASTEMATE' (100' TO 75') SUBMERSIBLE MODEL M282 1/2 HP PUMP 1000 GAL H-70 ST WGT. 9240 LB (SHOREY) _, .,PUMP OFF 8' SYSTEM (OR EQUAL) 8.5 x 4.83 x 2.91 x 62.4 = 7455 UP (OKAY)2.5Y 6/4 000000 0000 0000 0000 WATERPROOF 64" QBS-WATER 4.4' PUMP CHAMBER (NOT TO SCALE) 68" 4.1' DIRECT ALL FROM FOUNDATION RUN-OFF AWAY NOTES. 3,04 r PROVIDE APPROX. 45' 40 MILL LINER IN AREAOF SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) 1. DATUM 15 NGVD SHOWN, 2' OFF PORTION OF _ 330 EXISTING LEACH FACILITY. TOP AT y DESIGN FLOW: 3 BEDROOMS (110 GPD) - GPD 2. MUNICIPAL WATER IS EL. 10.4', BOTTOM AT EL 14,22 s USE A 330 GPD DESIGN FLOW 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 499 ', SEPTIC TANK: 330 GPD ( 2 ) _ 660 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 BENCHMARK ✓/ IP 5. PIPE JOINTS TO BE MADE WATERTIGHT. TOP AC UNIT �s 4.00 \ USE A 1500 GALLON SEPTIC TANK ELEv= 11.66' 1 P� 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. 1150 cps LINE S$. e 0 LEACHING: ENVIRONMENTAL CODE TITLE V. PROP. VENT WITH CHARCOAL FILTER N/A 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT AND BUGSCREEN (FINAL PLACEMENT BY V\NE 'o l)� SIDES[ TO BE USED FOR ANY OTHER PURPOSE. CONTRACTOR WITH HOMEOWNER 8.91 ZER \ y WP 3.03 22.75 X 16 (.74) - 269 CONSULTATION) z 29 � ,� \`�4� � BOTTOM: 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. e TOTAL: 364 S.F. 269** GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT +8.7 LO 7USE 22.75' x 16' LEACH FIELD OF 2 ROWS OF 3 INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED 9, 18 Fi f � `� I S I FROM BOARD OF HEALTH. 11 z `� STANDARD INFILTRATORS EACH, WITH 3.5' STONE AT 10. PUMP & REMOVE EXISTING SEPTIC SYSTEM EXIST. 15 GAS \ X388 CTI SIDES AND BETWEEN ROWS AND 2' AT ENDS 9 TER DWELL. 14. 11. ELECTRICAL PERMIT REQUIRED .84 + TF .75 -(-3 .75' m.NC BLOCK AIL, ,0� **25% REDUCTION: - SEE VARIANCE REQUEST y o R - � ,+382 OVERHEAD WIRES , LEGEND TITLE S SITE PLAN 100.0 PROPOSED SPOT ELEVATION t0. TF=70.27 PAVED 3z OF 31 GRIST MILL LANE NOTE: EXISTING SEPTIC DRIVEWAY ,RES 0 SYSTEM (UNKNOWN 9 9. O�RHEAD „-,-K *1' _ _ � + 100x0 EXISTING SPOT ELEVATION COMPONENTS) IN AREA OF �- SLOG - 1-3,80 - IN THE TOWN OF: PROPOSED SYSTEM. PUMP HED. 9.95 S' 4 '60 r\k. _' #7 100 YARMOUTH / n u AND REMOVE. 6'O, B 5 5 o n 0 PROPOSED CONTOUR (WEST) I A R M O U TI. I 0o SLAB o os 1 DECK s - 100 - EXISTING CONTOUR .9 -.'1- 115 p0 +3,4 PREPARED FOR:HICKEY CONSTRUCTION/GI AN GRANDE 2' REMOVAL OF UNSUITABLE SOIL (�'�t ,p. 50'��P�O#4 REQUIRED AROUND PERIMETER OF / ' LEACHING FACILITY, DOWN TOC C0 -'- LAYER. REPLACE WITH CLEAN% _�1,.°9G� 20 0 20 40 60 MED. SAND. BP . .b'S #3 BOARD OF HEALTH / 73-gf I I MA SCALE: 1 = 20' DATE: DECEMBER 28, 2003 PROVED DATE REV 1/23/04 (PER BOH) `-1.4.53 TOP BANK #1 off 508-362-4541 c no fax 508 362-9880 03-366 ��\,SHOF'N4SSg0 ��L'(H OF 1,ygSS9 bu GN Cs to down cape engineering, inc. ���� AH E y`m �o� oNAE�H oyGm APR Y• 3 2004 OJALA CIVIL y CIVIL ENGINEERS No. 26348 q No, 30792 HEALTH DEPT. LAND SURVEYORS �qMaEsslio s oNn IL q 939 main St. yarmouth, ma 02675 ARNE H. OJALA, E., P.L.S. ATE