Loading...
HomeMy WebLinkAboutEngineer Plans - 2021LOT 10 AREA = 59,677 sf+— +G4.5 5EFTIC TANK COVER @ EL. GO.7 m WATER :OX. WATERSEKVI EcA� .O GA5 5EKVIG _ G3. 0 _ 65.0 Q0 IN G4 S2 5 It YARMOUTH PROPOSED CONTOUR PROPOSED SPOT GRADEl ROCkc ROAD I j ®®gg ®® EXISTING CONTOUR z + 96.52 EXISTING SPOT GRADE ro I Nom' e ROgp ®W— EXISTING WATER SERVICE ti TEST PIT LOCUS183 PINE 8T. I. SCALE 1"=30' GI. +GO.3 +G0.9 7.3 LEGEND YARMOUTH PROPOSED CONTOUR PROPOSED SPOT GRADEl ROCkc ROAD I j ®®gg ®® EXISTING CONTOUR z + 96.52 EXISTING SPOT GRADE ro pe Nom' e ROgp ®W— EXISTING WATER SERVICE ti TEST PIT LOCUS183 PINE 8T. WN 3 SCALE 1"=30' Per®tt valid for REPAIR OF SEPTIC SYSTEM ONLY, due to .State and Local septic varinaces, Board of Health ,esiew and approv9l is required for. any future additionsirenovstions/alterations to stwage facilities and/or structuresldwelling. Yarmouth Health itleparttaent APPROVED SURVEY BY: WELLER AND ASSOC. LOCUS MAP LOCUS INFORMATION PLAN REF: 488/087 TITLE REF: 9049/208 PARCEL ID: MAP 114. PAR. 1.1 FLOOD ZONE: NOT IN FLOOD ZONE SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 183 PINE STREET YARMOUTHPORT, MA PREPARED FOR MAY 7, 2021 OF 1121 MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (500360-3311 fax (774)413-9466 meyerandsonstitle5@gmail.com 1 OF 2 697 TOP OF FND. EL. = 64.0 x711151 63.0 INV. 59. F.G.EU 63.0 10-1 1 TEE'S ARE TO BE 4" SCH 40 PVC BAFFLE INV: 59.40 EXIST. 1,000 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK WITH 1500 GALLON SEPTIC TANK IF FAILED, DAMAGED OR UNDERSIZED. 4) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED GENERAL NOTES: 1. RCHAN OFGES HEALTH AND THE To THIS PLADESIGN ENGINEER. ST BE APPROVED By THE LOCAL IREMENTS 2. ALL WORK OF THE STATED ENVIRONMENTALCODE, ,TITLE V, AND ANY MATERIALS SK41L CONFORM TO THE APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL. SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM BEFOREWCONSTRUCTION CONTINEREON SHALL BE UES. ®TO THE DESIGN 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 5. TTHE HE C0 DESIGN NTRACTOR OAR OWNERNOT TOENOTTIIFFYYIBLE THE LOCAL BOARFAILURE OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7, WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGR® UPON BETWEEN OWNER AND CONTRACTOR. S. THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNINGNSIBILITY OF THE CONTRACTOR To IFY E IT SHALL BE THE CONSTRUCTION. 10, EXISTING LEACH PIT TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5- 11. 48 HOUR DICE FOR ENGINEER CERTIFICATION 12. THIS PLAN S TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. D PRIVATE WELLS WITHIN 150° OF PROPOSED LEACHING. 14. D WETLANDS WITHIN 100' OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4" SCH 40 a I/8"/Fr (UNLESS SPECIFIED) NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS BRING ALL COVERS TO WITHIN 3" OF FINISH GRADE F.G. EL: 62.80 INV. PROPOSED DB -3 DISTRIBUTION BOX (H20) SEPTIC SYSTEM PROFILE MAINTAIN 2% MIN SLOPE OVER LEACHING AREA 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC 4" SCH 40 PVC 0 INV. ELEV.= 58.80 TOP CONC. ELEV.= 59.80 INV. ELEV.= 58.80_ BOTTOM EL.= 56.80 - SEPARATION 5.30 FT. BOTTOM OF TESTHOLE EL: 51.50 SOIL LOGS DATE: APRIL 28, 2021 SOIL EVALUATOR: DARREN MEYER, R.S., CSE x!1614 WITNESS: MALLORY LANGLER, YARMOUTH HEALTH DEPT. EBev. TP -1 D.En 62.50 A 0" LOAMY �D 61.25 ® �" LOAMY SAND 10YR 5/8 59.58 _ 35" MEDIUM SAND 2.5Y E/4 51.50 I 1132" PERO RATE <2 MIN/IN. (`C3' HORIZON) NO GROUNDWATER OBSERVED c I, Dacron M. Meyer, R.S.. CSE, hereby certify that I am oumently approved by MADEP Pursuant to 310 CMR 15.017 to conduct gall evoluatloee and that the aboveanalysis has been Wormed by me aonalstent with the roquiromenta of 310 CMR 15.017. 1 further oeIHy that I have passed the Soil Eval. Exam in October, 1999. 2 X 8.5' EFFECTIVE LENGTH = 25' 3/4• - 1_1/2` DOUBLE WASHED rd BREAKOUT ELEV.= 60.0 3.75' 5 FT. 3.75' EFFECTIVE WIDTH = 12.5' SOIL ABSORPTION SYSTEM (SECTION) 500 GALLON LEACH CHAMBER' DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 3 BR = DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 330 gpd x 200% = 660 gpd USE EXIST. 1,0006 SEPTIC TANK LEACHING AREA. REQUIRED: (330)/0.74 = 445.94 S.F. USE TWO (2) 500 GALLON PRECAST LEACH CHAMBERS W/ 4' STONE ON ENDS & 3.75' STONE ON SIDES: 25' L x 12.5' W x 2'D BOTTOM AREA: 25 x 12.5 = 312.5 SF SIDE AREA: (25 + 12.5) X 2 X 2 = 150 SF TOTAL SQUARE FEET PROVIDED = 462 vs. 445.94 REQ'® DESIGN FLOW PROVIDED: 0.74(462 S.F.) = 342.25 G.P.D. vs. 330 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 183 PINE STREET, YARMOUTHPORT, MA Prepared one for: S!REV Design and Site Plan try: LE DRAWN DMM DATE 05/07/21 MEYER A SONS, INC. N.T.S. l'n eoxssl DATE CHECKED SHEET N0. EAST SANDWICH, AIA 02537 DMM 2 of 2 508-362-2922 _