HomeMy WebLinkAboutEngineer Plans - 2016ACCESS FOR ROUTINE MAINTENANCE
MUST BE PROVIDED FOR ZABEL FILTER.
INSTALLER MUST FOLLOW ALL
MANUFACTURER'S SPECIFICATIONS FOR
PROPER FILTER INSTALLATION
------------
ALARM AND CONTROL PANEL
TO BE INSTALLED INSIDE PRECAST H-10•`
BUILDING. ALARM TO BE ON 20Rs (TVP.)
SEPARATE CIRCUIT FROM PUMP
INV. IN 3.72'
*4.0'
6" BAFFLE
*INTERIOR PLUMBING TO BE RE-ROUTED TO EXIT
THE DWELLING AS SHOWN IN PLAN VIEW. PLUMBER
TO CONFIRM FEASIBILITY PRIOR TO INSTALLATION OF
ANY SEPTIC COMPONENTS.
(2-% SLOPE)
MIN.
FOUNDATION - 14'
*THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL
UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS
PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM
2% MIN. SLOPE OVER SYSTEM
4" LOAM &SEED
30"f I CAP STONE UNITS
1/2" x 5 1/4"
6" COVER =Ali -II _ Fiberglass
-IL-
_II II_ Pins
S 3'MIN. - _T�
SYSTEM PROFILE
(NOT TO SCALE)
PROVIDE QUICK DISCONNECT FOR PUMP
---,ACCESS COVERS TO GRADE
NOTE: 3301 GAL. RESERVE
PROVIDED IN PC
"MIUM .75' OFOVER OVER PRECAST
i
ALL SYSTEM COMPONENTS SHALL BE - PROVIDE INSPECTION PORTS TO
MARKED WITH MAGNETIC TAPE OR ! WITHIN 3" OF FINISH GRADE
COMPARABLE MEANS FOR FUTURE (OCATION.
i,
2% SLOPE REQU)IED OVER SYSTEM
6" CRUSHED STONE OR MECHANICAL
COMPACTION. (15.221 [21) CHECK VALVE
2000 GAL. SEPTIC TANK/PUMP 5' D -BOX
CHAMBER COMBINATION
WATERPROOF MYERS SRM 4
/ WATERTIGHT SUBMERSIBLE 4/10 HP PUMP
SYSTEM (OR EQUAL)
BUOYANCY CALCS. (ON BLOCK)
H-10 2000 GAL. ST WEIGHS 14,160 LBS
2.85'x 12.0 x 6.5 X 62.4 = 13,904 LBS UP(OK)
s*AIN
99-
P
2" PRESSURE LINE
SLOPE TO DRAIN BACK
COARSE SAND BACKFILL A
4"0SCH4I PVC
W40
198.4]
PROPOSED SPOT EL.
TTH11
MIL LINER FROM TOP PEASTONE/WALLTO
PIPES LEVEL 1ST 2'
2>
OR EQUAL RETAINING WAL18"X8"
1
FLOAT SWITCH
�y4
PINS REQ.
14" TEE
6"X30" Crushed Rock or
750 GAL. MIN.
SETTINGS:
EE
Leveling Pod req.
RETAINING WALL
THIS SIDE OF
ALARM ON
6.23'
Locus
BAFFLE
a
m
o°o°o°o°o°o°
°°°°°°°°°°°
-
3
PUMP ON
°�°'" "
ZABEL FILTER
6
5" WORKING RANGE
6.43'
6.2 6'
(A100) OUTLET5„
omPs
WATERTEST D'BOX QUICK4 STANDARD LOW PROFILE UNITS
TEE W/
FOR LEVELNESS
EXTENSION
12"
PUMP OFF
0
OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 32' X 8.5
6" CRUSHED STONE OR MECHANICAL
COMPACTION. (15.221 [21) CHECK VALVE
2000 GAL. SEPTIC TANK/PUMP 5' D -BOX
CHAMBER COMBINATION
WATERPROOF MYERS SRM 4
/ WATERTIGHT SUBMERSIBLE 4/10 HP PUMP
SYSTEM (OR EQUAL)
BUOYANCY CALCS. (ON BLOCK)
H-10 2000 GAL. ST WEIGHS 14,160 LBS
2.85'x 12.0 x 6.5 X 62.4 = 13,904 LBS UP(OK)
s*AIN
99-
P
X 99.1
COARSE SAND BACKFILL A
99
W40
198.4]
PROPOSED SPOT EL.
TTH11
MIL LINER FROM TOP PEASTONE/WALLTO
12" BELOW GRADEKEYSTONE
2>
OR EQUAL RETAINING WAL18"X8"
1
SET WITH 1" BATTER PER ROFIBERGLASS
�y4
PINS REQ.
NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING
6"X30" Crushed Rock or
3.73
Unreinforced Concrete
Leveling Pod req.
RETAINING WALL
CROSS SECTION
NOT TO SCALE
LEGEND-
EGEND99
99-
EXISTING CONTOUR
X 99.1
EXIST. SPOT ELEV.
99
PROPOSED CONTOUR
198.4]
PROPOSED SPOT EL.
TTH11
C71
TEST HOLE
2>
SLOPE OF GROUND
1
UTILITY POLE
�y4
FIRE HYDRANT
NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING
TEST HOLE LOGS
ENGINEER: DANIEL E. GONSALVES, SE #13587
WITNE�. - A HONE, RS
DAT 8/13/15
PERC. RATE _ < 2 MIN/INCH
CLASS I SOILS
ELEV.
1
0" 3.8'
A
LS
9" 1OYR 3/2
B
LS
IOYR 4/4
18' 2.3'
PERC
C
FS
2.5Y 5/4
84" I -3.2'
GROUNDWATER ENCOUNTERED AT 28" EL. 1.47
DICE ##89-376
6" CRUSHED STONE OR MECHANICAL (NO STONE PROPOSED)
COMPACTION. (15.221 [21)
(-L-% SLOPE)
5.95'.
4'
TOP OF WALL
AT EL. 7.1
CAP STONE UNITS
Fiberglass
/Pins
w
40 MIL LINER FROM x
TOP PEASTONE/WALL
TO 12" BELOW GRADE n
_F \
m
a
5' LEACHING USE ADJUSTED GROUNDWATER
FACILITY OF EL. 1.95' PER TEST HOLES
PREVIOUSLY DONE IN THIS AREA
I
SYSTEM DESIGN:
GARBAGE DISPOSER IS NOT ALLOWED NOTES
EXISTING 3 BEDROOM DWELLING
1. DATUM IS NAVD 88
DESIGN FLOW: _3 BEDROOMS @ 110 GPD = 330 GPD 2. MUNICIPAL WATER IS EXISTING
USE A 330 GPD DESIGN FLOW
3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT.
SEPTIC TANK: 330 GPD (2) = 660 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS
USE A 2000 GAL. H-10 SEPTIC TANK/PUMP CHAMBER COMBO TO BE AASHO H -1Q
5. PIPE JOINTS TO BE MADE WATERTIGHT.
LEACHING:
6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH
4.72 SF/LF x 4' LENGTH = 18.88 SF PER 310 CMR 15.000 (TITLE 5.)
QUICK4 PLUS STANDARD LP UNIT 7. THIS PLAN iS FOR PROPOSED WORK ONLY AND NOT TO
BE USED FOR LOT LINE STAKING OR ANY OTHER
330 GPD/0.74 GPD/SF = 446 SF LEACHING PURPOSE.
REQ'D 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC..
446 SF/18.88 SF/UNIT = 23.6 UNITS 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED
WITHOUT INSPECTION BY BOARD OF HEALTH AND
THEREFORE, USE GRAVELLESS SYSTEM OF (24) PERMISSION OBTAINED FROM BOARD OF HEALTH.
QUICK4 STANDARD LP UNITS IN FIELD 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING
CONFIGURATION' OF 3 ROWS OF 8 UNITS DIGSAFE (1-888-344-7233) AND VERIFYING THE
LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES
24 UNITS x 18.8NIT = 453 SF> 446 SF PRIOR TO COMMENCEMENT OF WORK.
453 SF (0.74) L 335 PD (OK) 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE
REMOVED 5' BENEATH AND AROUND THE PROPOSED
LEACHING FACILITY.
12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND
REMOVED OR PUMPED AND'FILLED WITH CLEAN SAND.
13. ALL TANKS ARE TO BE INSTALLED WITH WATERTIGHT
SLEEVES, BOOTS AND'. TANKS_MUST`BE"WATERTIGHT.
14. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS
SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT
REQUIRED.
PROP. VENT WITH CHARCOAL. FILTER MAR 19 2021
AND BUGSCREEN (FINAL PLACEMENT BY
CONTRACTOR WITH HOMEOWNER
CONSULTATION) i '113.94 -
GAS LINE TO BE \,r o �, 3' REMOVAL OF UNSUITABLE SOIL REQUIRED
RE-ROUTED \\\ 0AROUND PERIMETER OF LEACHING FACILITY,
\ DOWN TO SUITABLE SOIL LAYER. REPLACE
3. �5
WITH CLEAN MED. SAND, TO MEET
. SPECIFICATIONS OF 310 CMR 15.255(3)
% n
PROVIDE 28' OF 40 MIL LINER AT 3' � \
OFF SAS IN AREA SHOWN. TOP AT
ELEV. 6.6', BOTTOM AT EL. 2.6't 3.87 *10
.73
IN h /�. \ EXISTING G•�
.59- .S3 0 4. WATERLINE V•�
.4.62 \ (RE-ROUTE)
4.65 �4. 8
,Pb�JDEN ; \\
.54 / 3 \ �( 3.78
93 / .99 70 S \
.29 t _ �C>{�f1 1 . .36 1 3 (l
• 3.92 4y17 - -<03 O
z 4.2%
4.73 I
14
Pi
i
X4.41 I
I
Scale: 1'I'= 20'
0 1T 20 30 40 50 FEET
-3l I L
DATE
Yarmouth Health Department
A �E
IZ
Name Ditto
L
DANIEL' A. OJALA, P.E., P.L.S.
\ PROPOSED RE-ROUTED
\ WATERLINE
3.66
�5
N 0
t
C71
CN
3.78
It
1
77
�y4
3.73
0
i
i
i
-3l I L
DATE
Yarmouth Health Department
A �E
IZ
Name Ditto
L
DANIEL' A. OJALA, P.E., P.L.S.
LOCUS MAP
NOT TO SCALE
ASSESSORS MAP 24 PARCEL 139
VARIANCES REQUESTED:
UNDER MAX. FEASIBLE COMPLIANCE 15.405:
(1a): REDUCTION IN SETBACK SAS TO LOT LINE (10' TO 8')
(tb): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 12.8')
(1h): REDUCTION IN SEPARATION TO G -W, 5' TO 4'
15.555 (5): REDUCTION IN LATERAL REMOVAL OF UNSUITABLE
MATERIAL (5' TO 3')
TITLE 5 SITE PLAN
OF
22 PAWNEE ROA®
WEST YARMOUTH, MA
PREPARED FOR
KAREN BOWEN
DATE: NOVEMBER 25, 2015
REV: MARCH 9, 2016 (SAS CHANGE)
off 508-362-4541
fax 508-362-9880
downcope.com
down cope engineering, inc,
civil engineers
land surveyors
939 Main Street ( Rte 6A)
YARMOUTHPORT MA 02675
89-376
�5
t
I
�y4
0
m
Locus
°
a
m
3
omPs
e
0
5
Lewis
pond
LOCUS MAP
NOT TO SCALE
ASSESSORS MAP 24 PARCEL 139
VARIANCES REQUESTED:
UNDER MAX. FEASIBLE COMPLIANCE 15.405:
(1a): REDUCTION IN SETBACK SAS TO LOT LINE (10' TO 8')
(tb): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 12.8')
(1h): REDUCTION IN SEPARATION TO G -W, 5' TO 4'
15.555 (5): REDUCTION IN LATERAL REMOVAL OF UNSUITABLE
MATERIAL (5' TO 3')
TITLE 5 SITE PLAN
OF
22 PAWNEE ROA®
WEST YARMOUTH, MA
PREPARED FOR
KAREN BOWEN
DATE: NOVEMBER 25, 2015
REV: MARCH 9, 2016 (SAS CHANGE)
off 508-362-4541
fax 508-362-9880
downcope.com
down cope engineering, inc,
civil engineers
land surveyors
939 Main Street ( Rte 6A)
YARMOUTHPORT MA 02675
89-376