Loading...
HomeMy WebLinkAboutEngineer Plans - 2003U U J 99,66 X t� w N SO°51'3 E - REMGVE EXISTING SEPTIC TANK AND LEACH PIT I i x 10P.7J I , BD. RM.O c Flo I j BD, RM, I Z x +,75 o LEGEND 38 PROPOSED CONTOUR erserr Pie m a �q 3pac: FI -3-81 PROPOSED SPOT GRADE 110 EXISTING CONTOUR o 10.02 EXISTING SPOT GRADE an < sy WeL TEST PIT Law SURFACE WATER FLOW o —W—W-- EXISTING WATER SERVICE ¢a 10 EXISTING TREE z Of OG 2s� m v of r—__� g o E F 3 s DECK a Fernduc St \ J FLOOR PLAN N.T.S. V � I I oA � / 2.kls\ ARAGE GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN `MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: 1) THE FOLLOWING VARIANCE IS REQUESTED UNDER 310 CMR 15.405, 'CONTENTS OF LOCAL UPGRADE APPROVAL: —310 CMR 15.405(1)(i): Request is made for a 1 foot reduction In the required 5 foot separation betwen bottom of S.A.S. and high groundwater elevation, for a separation of 4 feet. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE. LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER MAIN. 8. THERE ARE NO :PRIVATE WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION ARE TO BE LOAMED AND SEEDED UPON COMPLETION OF CONSTRUCTION. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING L, t; M 9 D CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND O 6 2004 UNSUITABLE MATERIALS IN THE AREA BENEATH AND FOR 5 FT. ON ALL SIDES of THE S.A.S. AND REPLACE WITH CLEV FILL AS SPECIFIED IN FH DEPT. 310 CMR 255(3). SEPTIC SYSTEM REPAIR/UPGRADE - 18 FILLMORE ROAD, YARMOUTH, MA Prepared for: Tom Kinsella, 18 Fillmore Road, Yarmouth, MA Engineering by: Surveying by: ISCALE DRAWN JOB. NO. Engineering Worb Terry A. Warner PLS 1 "-20' P.T.M. 83-03 23 Deer Hollow Road 22 Long Road Forestdole, MA 02644 Harwich, MA 02645 DATE CHECKED SHEET NO. (508) 477-5313 (508) 432-8309 11/24/03 P.T.M. 1 Of 3 ELEV. TOP FOUNDATION (Existing) =102.6 — PROVIDE COUPLING INV.=99.20± 0 .G.EL: 101.6 •J'ap A-1 INSTALL RISERS OVER INLET & OUTLET TO WITHIN 6" OF FINISH GRADE _ L=11' 4" SCH 40 PVC 0 S= 27. (MIND SEALED RUBBER BOOT POURED IN PLACE INV.=98.75 TEE'S ARE TO BE 4" SCH 40 PVC F.G.EL:101.5 PROVIDE 20" RISER W/COVER OVER PUMP TO WITHIN 6" OF FINISH GRADE SEALED RUBBER BOOT POURED IN PLACE INV. -99.00 INV. -99.00 GAS BAFFLE TO BE INSTSALLED ON OUTLET TEE AS MANUFACTURED BY TUF—TITE, ZABEL, OR EQUAL (See Pump Detail, Sheet 3 of 3) 1500/510 GALLON SEPTIC TANK/PUMP CHAMBER I-- 2B'"—� Closed End Plate 000000 0000000 00000000 f-- 23---I INSTALL INSPECTION PORT OVER A MINIMUM OF ONE DISTRIBUTION LATERAL, SET TO GRADE. F.G. EL: 106.2 —\ FINISH GRADE RANGES FROM 106.2 TO 106.3 INV.= 104.45 D-130 INV.=104.28 —1 TEE SHALL NOT EXTEND BELOW FLOW LINE SEPTIC TANK/PUMP CHAMBER .& D—BOX SHALL BE SET LEVEL AND TRUE.TOGRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). Open End Plate Z 12 75" 1.25 " Side View SEPTIC SYSTEM PROFILE N.T.S, g 34" End View STANDARD INFILTRATORS, H-20 LOADING INFILTRATOR CHAMBERS N.T.S. PRpppSED _ Z6, S.A.S. LAYOUT N.T.S. MAINTAIN 2% MIN SLOPE OVER LEACHING AREA L=20'(MAX) 4" SCH 40 PVC L S= 17. (MIND6° EFF. INV. ELEV. =104.08---'� 11' NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL.104.5 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. MAX. COVER OVER S.A.S. = 36" A 2' X 2' PATIOBLOCK AS A PAD AT INLET OF EACH CHAMBER 1 UNIT® 6.25' EFFECTIVE LENGTH = 9.75' USE 5 ROWS OF 1—STANDARD INFILTRATOR CHAMBERS �H-20) IN SERIES SURROUNDED W/STONE TO FOR A 9.75' X 46.0 S.A.S. ,OIL ABSORPTIOU SYSTEM (PROFILE) N.TS, BREAKOUT ELEV.=104.5 BOTTOM ELEV.=103.5 4' MIN. ABOVE BOTTOM 0 T,P. EXCAVATION OR G,W HIGH G,W, EL; 99,5 .SOIL ABSORPTION SYSTEM (SECTION) NT.s (0 Z' 2' LAYER OF 118"-112' DOUBLE WASHED STONE 3/4'-1 112' DOUBLE WASHED STONE DESIGN CRITERIA 1� of NUMBER OF BEDROOMS: 2 BEDROOMS o PETER T, ✓+ SOIL TEXTURAL CLASS: CLASS I McENTEE DESIGN PERCOLATION RATE: <2 MIN/IN CIVIL No: 35109 DAILY FLOW: 220 G.P.D. QFC/514R�� EQ DESIGN FLOW: .330 G.P,D. FSS 0 A GARBAGE GRINDER: NO PROPOSED SEPTIC TANK: 1500 GAL, CAPACITY PROPOSED PROPOSED CHAMBER: 500 GAL. CAPACITY i,? --to LEACHING AREA. REQUIRED: (330) = 445.9 S.F. .74 USE 5 ROWS OF STANDARD INFILTRATOR UNITS (TOTAL=5) IN A 9.75' x 46.0' FIELD CONFIGURATION AS SHOWN SIDEWALL AREA: NOT APPLICABLE BOTTOM AREA: 9.75' x 46.0'. = 448.5. S.F. TOTAL AREA: 448.5 S.F. DESIGN FLOW PROVIDED: 0.74(448.5 S.F.) = 331.9 G.P.D SEPTIC SYSTEM REPAIR/UPGRADE 18 FILLMORE ROAD, YARMOUTH, MA Prepared for: Tom Kinsella, 18 Fillmore Road, Yarmouth, MA Engineering by: Surveying by: SCALE DRAWN J06. NO. Engineeringworke Terry A. Warner PLS N.T.S. P.T.M. 83-03 23 Deer Hollow Rood 22 Long Road DATE CHECKED SHEET Na. Forestdale, MA 02644 Harwich, MA 02645 (508) 477-5313 (508) 432-8309 1 11/24/03 1 P.T.M. 2 oP 3 INSTALL 1' PVC CONDUIT TO HOUSE FOR WIRING WITH WATERTIGHT JOINTS. WIRE HIGH WATER ALARM FLOAT TO GP 2000 HIGH WATER ALARM PANAL ON CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. -� E A HOISTING CABLE 7x19 STAINLESS STEEL 1/8" DIAMETER, / 1,760 LB, STRENGTH INV.(IN)=98.50 ALARM ON EL: 96.50 PUMP ON EL: 95.84 PUMP OFF EL: 95.17 BOTTOM OF 16' ' 1 PUMP CHAMBER e° ELEV.= 94.0 - PROVIDE WATERTIGHT CONCRETE RISER WITH SECURED COVER TO GRADE NEMA 4 JUNCTION BOX CORROSION RESISTANT & LIQUID -TIGHT CABLE CONNECTORS SUPPORTED BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE WATERTIGHT 2"BALL VALVE w/ UNIONS SCH. 80 PVC GEORGE FISHER CO, MODEL NO, 560 2"SCH, 40 DISCHARGE TO D -BOX 2"SCH, 40 TEE w/ CLEAN-OUT CAP PROVIDE 1/4' WEEP HOLE IN DISCHARGE PIPE FOR SELF -DRAINING FORCE MAIN -2` BALL CHECK VALVE SCH. 80 PVC 100 P.S.I. FLOWMATIC MODEL No. 2085 PROVIDE 2- WIDE ANGLE FLOATS \ 2" SCH. 40 PVC DISCHARGE PIPE FLOAT N0,11 PUMP ON/OFF (BARNES 073618) \ FLOAT N0.2; ALARM ACTIVATION (BARNES 073612) BARNES SE411 PUMP .4 H,P, 115 V 2" DISCHARGE PASSING 2" SOLIDS PUMP CHAMBER, PUMP & ACCESSORIES AVAILABLE AS A UNIT THROUGH WIGGEN PRECAST CORP,, BOURNE MA, (800) 564-6774 PUMP & ACCESSORIES AVAILABLE THROUGH WILLIAMSON ELECTRIC (781) 444-6800 PUMP DETAIL N.T.S. 12'-2" 3 - 20" Dia. Covera 6'-8 O� O q O Dia. Outlets SOIL LOG -5" DATE: SEPTEMBER 25, 2003 SOIL EVALUATOR: PETER McENTEE INSPECTOR: DAVID FLAHERTY R.S. HEALTH AGENT PLAN 6" Die. outlets NOTES: 1. UNIT SHALL BE SEALED, WRAPPED & MADE WATERTIGHT. 2. ALL PIPING JOINTS SHALL BE MADE WATERTIGHT. 1500/500 GALLON CAPACITIES (H-20) SEPTIC TANK/PUMP CHAMBER N.T.S. Elev. TP -1 Depth 100.2 0° A SANDY LOAM 10YR 3/2 98.7 a 18" SANDY LOAM 1 CYR 4/6 97.4 C 34" COARSE SAND 10YR 6/8 98.7 ADJUSTED G.W. _ 96.0 STANDING G.W. _ 50" Elev. TP -2 Depth 100.600.6 0" 'ILL 97.9 A SANDY LOAM 10YR 4/1 97.0 8 SANDY LOAM 10YR 5/6 96.3 C1 COARSE SAND & GRAVEL 10YR 6/6 98,7 ADJUSTED G.W. - 96.0 STANDING G.W. _ 32" 43" 52" 3-5" DIA. SOIL LOG DATE: NOVEMBER 23, 2003 SOIL EVALUATOR: PETER McENTEE Elev, TP -3 Depth 99.5 0" A SANDY LOAM 10YR 3/3 99.0 9 6" FINE SAND t OYR 4/6 97.51- 24" COARSE SAND 10YR 6/8 99.5 ADJUSTED G.W. 96.5 STANDING 55" Section 90.2 1 1120" 90.6 120" 93.5 1 172" STANDING G.W. ® 50" STANDING G.W. 0 55" STANDING G.W. 0 36" PERC RATE <2 MIN/IN. ("C" HORIZON) PERC RATE <2 MIN/W. ("C" HORIZON) PERC RATE <2 MIN/IN. ("C° HORIZON) G.W. ADJUSTMENT 0.5 X 5.3'=2.7' G.W. ADJUSTMENT 0.5 X 5.3'=2.7' G.W. ADJUSTMENT 0.5 X 6.0'=3.0' (AIW 230 -SEPT 2003) (AIW 230 -SEPT 2003) (AIW 230 -OCT 2003) 7 1/2" TS 2" FORCED INLET W/ VERTICAL TEE 30 V2' FILL SIDE KNOCK -OUTS WITH MORTAR Top View DISTRIBUTION BOX N.T& 5 V2° 4" cRAwty. OUTLET(TYP.) a Y OF M9TUA PETER T, 5 McENTEE m CIVIL No 35109 N BUOYANCY CALCULATIONS %�-01�v(w� Septic _Tank/PUmD Chamber Unit BOTTOM OF PUMP CHAMBER EL.= 94.0 HIGH GROUNDWATER EL=99.5 BUOYANCY FORCE PER FOOT OF DEPTH: 6.67' x 12.17' x 1.0' x 62.4 166/cu.ft. = 5,065,3 lbs/ft MAXIMUM DISPLACEMENT = 99.5-.94.0= 5.5' MAX. UPLIFT PRESSURE = 5.5' X5,065.3 lbs/ft = 27,859.2 Ibs. WEIGHT OF EMPTY PUMP CHAMBER = 26,176 lbs. WEIGHT OF SOIL OVER SEPTIC TANK/PUMP CHAMBER (1' COVER): 6,67' x12.17' x 1.0' x 110 Ibs/cu,ft. = 8,929.3 lbs COMBINED WEIGHT = 26,176 LBS. + 8,929 LBS. = 35,105 LBS. 35,105 LBS. > 27,859 LBS, O.K. DOSING & STORAGE REQUIREMENTS DAILY FLOW: 330 GPD DOSING REQUIRED: 4 CYCLES/DAY (SAND) 330 - 4=82.5 GALLLONS/CYCLE DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: 82.5 GAL/CYCLE - 125 GAL/FT = 0.66 FT/CYCLE STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: INV.(IN) EL:98.50 - PUMP ON EL:95.84 =2.66' STORAGE PROVIDED = 2.66' X 125 GAL/FT = 332.5 GALLONS