Loading...
HomeMy WebLinkAboutEngineer Plan - 2017SYSTEM PROFILE PROVIDE INSPECTION PORT TO GRADE 4" SCH40 PERFORATED PVC DOWN TO (NOT TO SCALE) SAND AT BOTTOM LEACHING FIELD, NOTES ' SYSTEM DESIGN. RESSURE ALL SYSTEM COMPONENTS SHALL BE PROVIDE 4" THREADED COVER AND 4" VENT, PERF. ZONING SUMMARY MARKED WITH MAGNETIC TAPE OR LEBARON LA910 CAST IRON ACCESS COMPARABLE MEANS FOR FUTURE LOCATION. RUNS UNDER 2" PROVIDE CHARCOAL FILTER 1. DATUM IS NAV$$ GARBAGE DISPOSER 15 NOT ALLOWED 9-14-15 PREPARED FOR CHLECK FAMILY FOUNDATION, INC. PROVIDE MIN. 20" DIAM. WATERTIGHT PORT H-20 CONSTRUCTION. L AND INSECT SCREENACCESS 2. MUNICIPAL WATER IS EXISTING ® 110 GPD = 660 GPD MIN. COVERS TO WITHIN 6" OF FIN. GRADE DRILL LAST HOLE IN EACH FDAPTOR &THREADED PLUG ON TOP TO VES 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. DESIGN FLOW: 6 BEDROOMS LOT FRONTAGE ' TO F ND. 11.5' 2R SLOPE REQUIRED OVER SYSTEM LATERAL 1.5"0 THREADED END CONNECTION FILLS FRONT SETBACK USE A 660 GPD DESIGN FLOW \ FAIR iiTM�INIMUM75'.OF WHILE LATERAL SCH 40 PVC 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO REAR SETBACK 20' - COVER OVER PRECAST 8.0' WITNESS: AMY VON HONE, RS BE AASHO H-ZS1 DATE: 7/27/2016 1/4" SHIELDED 717• PERC. RATE _ < 2 MIN/INCH SEPTIC TANK: 660 GPD (2) = 1320 PRECAST H-10 (M•) ORIFICES _ INVERTS LEVEL AT 7.0' 5. PIPE JOINTS TO BE MADE WATERTIGHT. (1) 2500 GAL. H-20 SEPTIC TANK/PUMP CHAMBER YRISERS . INV. 7.0' CS o oho 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH COMBINATION - *7 0' 2" PRESSURE UNE 310 CMR 15.000 (TITLE 5.) 2500 GAL LEACHING: 10" SEPTIC TANK/ 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO GPD / (.74) = 892 SF REQUIRED 6.65' ' TEE PUMP CHAMBER BOTTOM LEACHI G LEVEL AT EL 6.5' BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 660 COMBINATION 2" END FED MANIFOLD CONNECT ENDS 30' X 30' = 900 SF OK SEE DETAIL BELOW PITCH TO DRAIN BACK TO 5.0' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 900 SF X .74 = 666 GPD OK ..:`.; .- PUMP CHAMBER- NO LOW SPOTS. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED DOSED PIPE AND STONE LEACHING FIELD :-><' t... : ,..,.:.•..; ee a o ; ,'o ;'e o e e e o e"eeeeeee I w.. 3/4" To 1 t/2' DOUBLE WASHED STONE WITHOUT INSPECTION BY BOARD OF HEALTH AND USE A 30 X 30 P eeeeeeeeeeeeeooeooe"oeee o o cc o 0 0 0 0 0 0 0 0 0 0 +009,o°,oe."o„o„o„o„000"eoeooeo�e"o"o„o"000e000. OR CONTRACTOR OBTAINED FROM BOARD OF HEAL *THE INSTALLER SHALL VERIFY THE SIDE ELEVATION VIEW LOCATIONS OF ALL UTILITIES AND ALL 6' CRUSHED STONE OR MECHANICAL SHALL BE RESPONSIBLE FOR CALLING BUILDING SEWER OUTLETS AND ( 2 R SLOPE) COMPACTION. (15.221 [23) DIGSAFE (1-888+-344-7233) AND VERIFYING THE LOCATION MA ELEVATIONS PRIOR TO INSTALLING ANY -M. GROUNDWATER 1.5' OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO LOCUS MAP PORTION OF SEPTIC SYSTEM WATERPROOF/ WATERTIGHT (TIDALLY -INFLUENCED GROUNDWATER) COMMENCEMENT OF WORK. APPROVED DATE BOARD OF HEALTH LEACHING E "-2000'1 FOUNDATION - 12' - SEPTIC TANK/ 13' FACILITY PUMP CHAMBER ORIFICE SHIELU U5Zuu ORENCO SYSTEMS INC PH. 1-800-348-9843 OR EQUAL 24 REQ. /4"0 HOLE AT 5 O.C. SNAP-ON ' EXACT DIAMETER HOLES SHIELD SHOULD BE SHOP DRILLED WITH A DRILL PRESS TO ENSURE c� DRAINAGE SLOTS UNIFORMITY, REMOVE BURRS PRIOR TO PLACING PIPE. ORIFICE SHIELD DETAIL NOT TO SCALE 2� MAP 14 PARCEL 24 moi► / , �/ rn 00 6 �� , ,a.11"COASTAL i'1//' -J j, , 5► arINAVOI BEACH APPROVED FOOTPRINT 477,UNDER SE83-2038 '11.(HATCHED AREA) j 444 Lu M Z ° 0.0' w W 0 D .I f WORK LIMIT LINE OF STAKED SILT FENCE o MAP 14 PARCEL 15 i CE ¢#16-243 x SHELL DRIVE \ SHELL DRIVE DRAIN I �yN( vot MAP 14 PARCEL 22 BENCHMARK: CEMENT BOUND = AW NAVDRR 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE SCAL 1 - REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. ASSESSORS MAP 14 PARCEL 23 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND LOCUS IS WITHIN FEMA FLOOD ZONE AE (EL 11) BUOYANCY CALC: REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. & VE (EL 13) AS SHOWN ON COMMUNITY 2500 2 COMPARTMENT TANK WEIGHT: 32,000 LBS 13. DRYWELLS PROPOSED FOR ROOF RUN-OFF (OR STONE PANEL #25001CO588J DATED 7/16/2014 2.35 x 6.0 x 11 x 62.4 = 9,678 UP (OK) TRENCHES AT ROOF DRIP LINES) 14. REFERENCE LANDSCAPE DESIGN PLAN BY INFINITY DESIGN GROUP, INC., DATED 10/11/2017 (REV. 1/2/18) ZONING SUMMARY 15. REFERENCE CURRENT APPROVED SITE PLAN DATED 9-14-15 PREPARED FOR CHLECK FAMILY FOUNDATION, INC. 16. FLOODZONE FOUNDATION DESIGN BY OTHERS ZONING DISTRICT: R-25 DISTRICT MIN. LOT SIZE 25,000 S.F. TEST HOLE LOGS MIN. LOT FRONTAGE ' MIN. FRONT SETBACK 0 30' 30' MIN. SIDE SETBACK 15' ENGINEER: CRAIG J. FERRARI, SE #13871 MIN. REAR SETBACK 20' - MAX. BUILDING COVERAGE 25% WITNESS: AMY VON HONE, RS DATE: 7/27/2016 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS v ELEV. 2 ELEV. 0,. 4 5' 0" Q 5.2' A A LS LS 9" 1OYR 4/2 12 1O R 4/2 B B \ LS } LS 29" 1 OYR 5/8 2.5' 36" 10 R 5/8 2.2' C C PERC MS MS G -W ADJ. DATA: WELL: MIW 29 1OYR 7/4 1OYR 7/4 ZONE: A ADJ: 2.2' JULY 2016 120" -5' 96" -2.8' GROUNDWATER ENCOUNTERED AT 59" EL. 0.08' s� \ is 's r f i j Try MIRAFI 140N NONWOVEN FILTER FABRIC N OVER WASHED STONE FORM TO ALL Boal AREA TOWN BYL S GULAT) N 2.0- LATERAL WITH DRAIN/ N VuORK �- ORIFICES & SHIELDS 3 4" TO 1-1 2" DOUBLE - �.. ����� WASHED STONE ff "h COMPACTED CLEAN MEDIUM SAND FILL ONLY. N LEACH .6 � CROSS SECTIO L� N.T.S. ACCESS FOR ROUTINE MAINTENANCE PATIO MUST BE PROVIDED FOR ZABEL FILTER. 24"S+• H-20 CAST IRON COVERS TO GRADE INSTALLER MUST FOLLOW ALL 5 MANUFACTURER'S SPECIFICATIONS FOR 830 GAL RESERVE I LAWN APPROVED F00 INT' PROPER FILTER INSTALLATION jbi UNDER SE83- 38 (HATCHED AR ) ALARM AND CONTROL PANEL MAP 14 TO BE INSTALLED INSIDE PARCEL 19 BUILDING, ALARM TO BE ON INV. IN 6.65' O p0 s� SEPARATE CIRCUIT FROM PUMP 2" PRESSURE LINE ZABEL FILTER 19" TEE SLOPE TO DRAIN BACK LAWN FLOAT SWITCH ALARM ON (A100) WEEP HOLE OUTLET TEE W/EXTENSION SETTINGS: 1657 GAL PUMP ON THIS SIDE CHECK VALVE 5" WORKING RANGE 6" of BAFFLE MYERS SRM 4 E 4/1 P PUMP PUMP OFF 12" SYSTEM (OREQ AL) 7 (ON BLOCK) $8"- 4'30 I \ 4 DOSES PER DAY, AT 110 GAL. PER ���� � � 4 ,97'} _� c4 DOSE (5" WORKING RANGE) 6" BAFFLE PA H "`--------- , L- lA, H-20 2500 CAL. SEPTIC TANK/PUMP CHAMBER COMBINATION (NOT TO SCALE) OWNER OF RECORD MICHAEL D. & RITA P. SWEAT 91 SPOFFORD STREET GEORGETOWN, MA 01823 REFERENCES CERT #203928 LCP 14426-K SE83-2038 (CURRENT) MANHOLE COVER MORTAR ALL COMPONENTS (TYP.) /24" 1 D PRECAST CONC. RISER AS REQ. 4'0 PRECAST DONUT 1" OVER FIELD ! 4" THICK 4000 PSI CONIC, W/WWF 18"0 OBSERVATION HOLE IN CTR. LEACHING FIELD 12" PERF. HDPE PUMP OUT WELL TO SAND AT BOTTOM L.F. NOT TO SCALE 'T #29 SCALLOP ROAD WEST YARMOUTH, MA PREPARED FOR MICHAEL D. & RITA P. SWEAT DATE: OCTOBER 11, 2017 REV. JANUARY 9, 2018 (CONSERVATION COMMENTS) Scale: 1"= 20' D75 -m-1 0 20 3040 50 FEET DANIELA. yGN %'� DANIEL GNm OJALA o A. CIVIL N �" OJAL A o' P No. 46502 w� No. 4098n DATE DANIEL A. OJALA, P.E., P.L.S. I off 508-362-4541 fax 508-362-9880 downcape.com we cape engi7eerI irS IVe. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16-243