Loading...
HomeMy WebLinkAbout21-A144 Site Plan of LandNACCESS COVERS MUST BE WITHIN 9' MINIMUM. { 6' OF FINISH GRADE 3' MAXIMUM COVER A 97.0 FIRST 2' TO L OCUS MAP GENERAL NOTES: I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OFT11E SEWAGE DISPOSAL SYSTEM AND PERMITTING PURPOSES ONLY. 2. VERTICAL DATUM IS ASSUMED.. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE -OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS.' 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EOUAL. BE LEVEL MIN 2' OF PEASTONE OR FILTER FABRIC 9' D1AM PIPE 93.5 0 92.75 91.83 2 �" DOUBLE WASHED STONE 93.0 GAS BAFFLE 92.0 2% 89.3 S 87.3 3 OUTLET 3-500 GAL LEACHING CHAMBERS D-BOX W/4' STONE AROUND. 12.8`r x 33.5'1 x 2'd 1500 GAL H-20 SEPTIC TANK 6' CRUSHED STONE OR COMPACTED BASE PROFILE : NOT TO SCALE INVERT ELEVATIONS: DESIGN CRITERIA: INVERT AT BUILDING: 93.5 DESIGN FLOW: INVERT IN SEPTIC TANK: 93.0 4 BEDROOMS AT 1/0 G.P.D. PER INVERT OUT SEPTIC TANK: 92.75 BEDROOM EQUALS 440 G.P.D. INVERT IN DIST, BOX: 92•0 INVERT OUT DIST. BOX., 91.83 NO GARBAGE GRINDER INVERT IN LEACH CHAMBER: 89•3 SEPTIC TANK REQUIRED: BOTTOM OF LEACH CHAMBER: 87.3 440 G.P.D. X 200x - 880 GAL. ADJUSTED GROUND WATER: NIA SEPTIC TANK PROVIDED: 1500 GAL. MINIMUM OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE #1: 75.4 SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 MIN/INCH SOIL TEXTURAL CLASS = I EFFLUENT LOADING RATE = 0.74 GPD/SF 440 GPD / 0.14 GPD/SF = 595 S.F. REOUIRED PROVIDED: 3-500 GAL LEACHING CHAMBERS W74' STONE AROUND, A=614 S.F. 614 S.F. x 0.74 = 454 G.P.D. CB RRKA C8 61/ r \ \ r t \ \ V 6. SEPTIC TANK AND D-BOX SHALL BE REINFORCED I I \ PRECAST CONCRETE OR APPROVED POLYETHYLENE. I s I \ BOTH SHALL BE WATERTIGHT. D-BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. { } I \ \ \\ 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. \ t\\\ 1 1 t I 1 t } t t I I \\ yy W \ 1-868-DIG-SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 29.35 1 8. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE I I I f I \\ l DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION 1 1 \ !1 OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE CONSTRUCTION INSPECTIONS. 9. ALL UNSUITABLE MATERIAL IA 6 B HORIZONS( ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' \\ \\ t AROUND AND REPLACED WITH SAND IN ACCORDANCE t \ \ o \ l WITH TITLE 5. 10. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. \ l 1. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY i TO HAVE THE PROPOSED BUILDING FOUNDATION � p Ii If DESIGNED TO ACCOUNT FOR THE EXISTING GRADE DESIGNED y AND SOIL COND I T IONS AT THE LOCATION OF THE Ab�y� hl f/ \`\\ \�' t \ \\ tVAvro i /$%I/ \\ PRIYEWAY PROPOSED BUILDING. \ GARAGE \\ \\\ r I�{ I \ t I I I 1 \ t \ t \ I \ t t ' \ 1 l 1\ GRAVEL DRIVE \ �r Z. PROPOSED DR I VEWAY9 (. 92.6 C8 DU FLIP EXISTING 92.5 \\ \ \ -_--._-- ~��' i/ ♦ /�'�„_, \ \ t \\ i2' NES SEPTIC SYSTEM 6 TO BE REMOVED`. rJ \---_ ` \\\ -4 _. rOPOSEO 71 YI •. \\ \\ \\ 7 RACE 91.1 Lu PR01°QSEp DWELLYNG 1 I / 1/ II II TOP O FOUND - 97. tA\ 2 I I 12 e ! g4 SOIL TEST PIT DATA® t I 1 ! / 1 1 \ TP041 - f /' _-9D' r ! er ! , ppAA INDICATFS INDICATES a* 1 I / ! ^' I i - \\ 10 1 I ! IW PERCOLATION = OBSERVED } I I ] Iy / / 1 I f EEBB TEST GROUNDWATER 1 I I I! I i J, / \ J 4 IW 'T BEI. CB SEAL END iP N TP x2 / 4 I j l it �ORCH ! .,...p: .i.. •+ i I k q. TP I E4-90.0/ i500GALLO=X';' D.BOX ✓ l"^ �4 HORIZON TEXTURE COLOR. HORIZON TEXTURE COLOR O` $9.4 0' 91.8 J/ 91.6 II ` / /n' 6rr '� / } TP*2 995 \1 \\\ .LOAMY. IOYR LOAMY IDYR ?' e' 1 i \,/ / / A SAND 3T3 SAND 3/3 g• _ _ _ _ _ _ _ _ _ _ _ _ _ 88.7 6" _ _ _ _ _ _ _ _ _ 91.3 c•'?�`� 1 7 7 3-!{OD GALLON( 8 LOAMY IOVR LOAMY IOYR \ / 7 / r r r- r r SAND 5/8 B SAND 5/8 �, \ / / J I q / / / 94 3 'r LEACHING CHAdY'BERS 30• _ __+_ _ _- _ - _ _ _ _ _ _- 86.9 30' _ _ _ _ _ __ _ _ _ _ _ _ 69.3 \/,c \...9 J / / -{- �-"` W 4' STONE AkOUND MEDIUM 10YR CI F(EDI UdI IOYR it % // / I 1 1 A SAND T/2 SAND 7/2 / Jl J J r "9 l +92.6 ti I I NO WA iER NO WATER I6H' T5.4 168' 77:8 TP 43 TP s9 J J r r rr HORIZON TEXTURE COLOR .. HORIZON TEXTURE COLOR 94 7 / {� 0' 94 1 0rr i4"_'O T 2 /r 0 0 J / J r Jrr45.677± S.F.f�r A LOAMY IOYR LOAMY IOYR SAND 3/3 '4 SAND 3/3 r / LOAMY IOYR g.. LOAMY IOYR SAND 5/8 SAW 5/8 / r C ! MEDIDI UM IOYR C I WD LW ,ozR r Jr 132• NO WATER 83.1 132" NO PATER .7 DATE: FEBRUARY 16. 2021 TEST BY. MIC14AEL O'LOUGM IN WITNESSED BY. 94LLORY LANGLER PERC RATE: f 3 MIN/INCH LEGEND ■ CB CONCRETE BOUND -W WATER L I NE 0 HYDRANT -G- GAS LINE - OHW- OVER HEAD WIRES #+ LIGHT POST - E UNDERGROUND ELECTRIC LINE -r- UNDERGROUND TELEPHONE LINE - CTV- UNDERGROUND CABLEVISION LINE 40.4 SPOT ELEVATION ...... 40- EXISTING CONTOUR -0 PROPOSED CONTOUR 0 LOT i 55.549f S.F II) 1 S 1 TE PLAN OF LAND 9 cz OAK H/LL LANE. MAP 1 19. P/O PARCEL 8 SOUTH YARN OUTH . MA . CB SEAL FND PREPARED FOR 0RE'G HANDREN SCALE 1 20 APR I L 23. 2021 STEPHEN A. HAAS, PE 293 Grcanv T ow Road B r ewws t e r NAA 02631 5� (508) 367-1691 �tf 0 l0 20 40 J08 NO: 21-001