Loading...
HomeMy WebLinkAboutEngineer Plan - 2020Permit valid for REPAIR OF SEPTIC SYSTEM ONLY, due to State and Local septic variances. Board of Health review and approval is required for (Iany Qfuture additions/renovations/alterations to kewaee facilities and/or structures/dwelling. N OF Yarmouth Health Department APPROVED 6.73 6.77 Tom ---1 U 1 Z PETER T. \ �� McENTEE \I CIVIL No. 35109 FEMA FLOOD DESIGNATION MAP NUMBER: 25001CO589J EFFECTIVE DATE: JULY 16, 2014 �nNia oP� (FI 11) FA x 7.50 (BENCHMARK bSTAIRWAY CORNER EL.=7.97 7.72 +N. 83.52'0 LOTS 43 446 7,5001 S.. F. 07.64 X HC /T. CELL X 7. I 656 5.93 GRAVEL DRIVEWAY 6.53 6.45 X DECK 6.77 X 1� SS 83 AUG 2 12020 HEA1_7H DEPT STRIPOUT BOUNDARY (SEE NOTE 11) - INSTALL 40 MIL POLY LINER (P TOP OF LINER, EL.=7.5 0 BOTT. OF LINER, EL. -5.0 rn Ij0 0- 0 O m PROPOSED SEPTIC SYSTEM UPGRADE PLAN LEGEND x 100.98 EXISTING SPOT GRADE --14 Ir ��i rrt�1 -G- EXISTING GAS SERVICE OVERHEAD WIRES TEST PIT qy BENCHMARK 1� SS 83 AUG 2 12020 HEA1_7H DEPT STRIPOUT BOUNDARY (SEE NOTE 11) - INSTALL 40 MIL POLY LINER (P TOP OF LINER, EL.=7.5 0 BOTT. OF LINER, EL. -5.0 rn Ij0 0- 0 O m - EXISTING LEACH PIT TO BE REMOVED -SEE NOTE 11 EXISTING SEPTIC TANK 5, 2 TO BE REMOVED -SEE NOTE 11 1 PROPOSED 1500/500 GALLON SEPTIC TANK/PUMP CHAMBER 103431 Or LOCUS MAP GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, except as requested below: -310 CMR 15.405(1)(b)&(h): CONTENTS OF LOCAL UPGRADE APPROVAL 1) A 10' varaince, S.A.S. to cellar wall, for a 10' setback. 2) A 1' reduction to the required separation between adjusted high groundwater and bottom of S.A.S., for 4' of separation. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANYCONDITIONSENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON NAVD88. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SUPPLY. V< THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE. DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. V11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED EXISTING SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. 14. THIS PLAN IS TO BE USED FCR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. MAP ID: 33-43 OWNER OF RECORD SUJKO ANN M MONTGOMERY LOREN M 2 PARKWAY DRIVE SAUGUS, MA 01906 PROPOSED SEPTIC SYSTEM UPGRADE PLAN LEGEND x 100.98 EXISTING SPOT GRADE --14 --EXISTING CONTOUR -W- EXISTING WATER SERVICE -G- EXISTING GAS SERVICE OVERHEAD WIRES TEST PIT qy BENCHMARK - EXISTING LEACH PIT TO BE REMOVED -SEE NOTE 11 EXISTING SEPTIC TANK 5, 2 TO BE REMOVED -SEE NOTE 11 1 PROPOSED 1500/500 GALLON SEPTIC TANK/PUMP CHAMBER 103431 Or LOCUS MAP GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, except as requested below: -310 CMR 15.405(1)(b)&(h): CONTENTS OF LOCAL UPGRADE APPROVAL 1) A 10' varaince, S.A.S. to cellar wall, for a 10' setback. 2) A 1' reduction to the required separation between adjusted high groundwater and bottom of S.A.S., for 4' of separation. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANYCONDITIONSENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON NAVD88. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SUPPLY. V< THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE. DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. V11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED EXISTING SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. 14. THIS PLAN IS TO BE USED FCR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. MAP ID: 33-43 OWNER OF RECORD SUJKO ANN M MONTGOMERY LOREN M 2 PARKWAY DRIVE SAUGUS, MA 01906 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 24 ANGUS AVENUE, SOUTH YARMOUTH, MA Prepared for: Loren Montgomery, 9 Parkway Drive, Saugus, MA 01906 Engineers: Engineering Works, Inc. 12 West Crossfield Road Forestdale, MA 02644 (508) 477-5313 Surveyors: JC Engineering, Inc. 2854 Cranberry Hay. E.Wareham, MA 02538 (508) 273-0377 SCALE 1"=20' DRAWN P.T.M. JOB. NO. 220-20 DATE 7/29/20 CHECKED P.T.M. SHEET NO. 1 Of 3 L oc PROPOSED SEPTIC TANK/PUMP CHAMBER NOTE: TO PREVENT BREAKOUT, INSTALL A 40 MIL PROPOSED D -BOX POLY LINER AS SHOWN ON SHEET 1. PROVIDE RISERS WITH APPROVED FRAMES & COVERS OVER EACH ACCESS MANHOLE AND SET TO FINISH INSTALL WATERTIGHT RISER & TOP OF LINER, EL.=7.5 BOTT. OF LINER, EL.=5 GRADE. MANHOLES BROUGHT TO GRADE SHALL BE COVER SET TO 6" OF GRADE PROPOSED S.A.S. SECURED TO PREVENT UNAUTHORIZED ACCESS. TION PORT (MIN.) INSTALL INSPECTION T.O.F.=6.9f F.G. EL: B.St EL.=8.3(MIN. G. ) F.G. EL=8.1±PROVIDE ENOUGH WIRE EXISTING F.G. EL.=7.27 SLACK TO REMOVE PUMP MAINTAIN 2% GRADE MINI CVER S.A.S. L =20' 2" 11 40 PVO L - B'(MAXi ®"SCH40 MIC) 4" DAM INSPECTION PORT, 12' x LEACHING FIELD W/3-4" PERFORATED IN S.A.S., SOLID ABOVE S.AnSiiNWITHO�CREWDE AP 0 S=1% (MIN.) TOP Ems.=6.1'7 pftOVIDE THRUST BLOCKS ALL BENDS 4"SCH40 PVC qT CAPPED ENDS STG. G.W. EL. -IA sCARVPvcE I SLOPE OF PERF. PIPE = 0.5x I INV. EL.=7.00(END) INVERT 4W I INV.=7.37 INV.=7.20 =5.08 ErNTJ ADJ D_BOx 25' EFFECTIVE LENGTH BEDROOM m BEDROOM G.W.PROPOSEa (v � M Eawq. G.W. EL -2.4 3 OUTLETS (MIN.) SOIL ABSORPTION SYSTEM OF1 o. INV.=4.83± H-10 INV.=7.13 _TING EL.-o.so DN DECK CONNECT TO EXISTING INV.=4.83SEWER INNVV.=5 80± EFFLUENT FILTER SHALL BE INSTALLED ON OUTLET EQUAL FILTER UV. RM. KIT./DIN. (verify) TEE AS MANUFACTURED BY ZABEL OR SHALL BE INSPECTED AND CLEANED ANNUALLY, OR AS REQUIRED TO AVOID SEWAGE BACK UP. ESTABLISH VEGETATIVE COVER (See Pump Detail, Sheet 3 of 3) GRADE FINISHE 1500/500 GALLON SEPTIC TANK/PUMP CHAMBER L=(RN j H-10 TANK ..,F „ �. :. ..:_ .. APPROVED NOTES: FILTER FABRIC 1) SEPTIC TANK/PUMP CHAMBER & D -BOX SHALL BE SET BREAKOUT ELEV.=7.48 - LEVEL & TRUE TO GRADE ON A MECHANICALLY COMPACTED BOTTOM ELEV.=6.50 STABLE BASE, PER 310 CMR 15.221(2). 3/4'-t 1/2" DOUBLE STONE FIRST & UPPER LEVELS 2) INSTALL INLET & OUTLET TEES AS REQUIRED. 4' MIN. SEPARATION TO G.W. 2' (WITH ASHE1 4 -4' 2' 3) MAX. COVER OVER TANK, D -BOX & S.A.S. SHALL BE 36". AN4' OF NATURALLY 12' EFFECTIVE WIDTH 4) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS OCCURRING PERVIOUS SOILS SOIL ABSORPTION SYSTEM (SECTION) PRIOR TO CONSTRUCTION. EST. HIGH G.W. EL: 2.4 _ BH SEPTIC SYSTEM PROFILE CELLAR P DECK LOG JSOIL LIV. RM. KIT./DIN. DATE: JULY 21, 2020 SOIL EVALUATOR: PETER NcENTEE PE, SE -1542 DESIGN CRITERIA WITNESS: MALLORY LANGLER, HEALTH AGENT ELEV. TP DEPTH NUMBER OF BEDROOMS: 2 a" 6.1 A FIRST & LOWER LEVELS SOIL TEXTURAL CLASS: CLASS I LOAMY SAND 4/2 DESIGN PERCOLATION RATE: <2 MIN/IN 55 B10YR 7 FLOOR PLAN DAILY FLOW: 220 GPD LOAMY SAND IOYR 5/8 DESIGN FLOW: 220 GPD PERC 7"/25" GARBAGE GRINDER: NO 3.6 30" LEACHING AREA REQUIRED: (220 GPD) = 297.3 SF C .74 GPD/SF MED. SAND 2.5Y 6/4 PROPOSED SEPTIC TANK/PUMP CHAMBER: 1500/500 GAL., H-10 SEPTIC SYSTEM UPGRADE PLAN PROPOSED D -BOX: 1 INLET, 3 OUTLET (MIN.), H-10 2.4 ADJ. G.W. 24 ANGUS AVENUE, SOUTH YARMOUTH, MA FIELD 4 -PROPOSED 1.1 6TG. G.W. 60" INSTALL AN 12' X 25' LEACH 0.1 72" Prepared for: Loren Montgomery, 9 Parkway Drive, Saugus, MA 01906 SIDEWALL AREA: NOT APPLICABLE PERC RATE <2 MIN/IN. ("B" HORIZON) Engineers: Surveyors: SCALE DRAWN JOB. N0. BOTTOM AREA: 12' X 25' = 300 S.F. STANDING G.W. 0 60" (EL.=1.1) S.F. INDEX WELL MIW-29, WATER LEVEL=7.7, JUNE 2020 Engineering WOTlG4, Inc. JC En meerzn ,Inc. N.TS. P.T.M. 220-20 TOTAL AREA: .....................................300 ZONE "A" ADJUSTMENT=1.3' (EST. HIGH GW=2.4) ✓ 12 West Crossfield Road 2854 Cranberry Hwy. LEACHING CAPACITY = 0,74 GPD/SF x 300 SF 222.0 GPD Forestdole, MA 02644 E.Woreham, MA 02538 DATE 7/29/20 CHECKED P.T.M. SHEET N0. 2 3 (508) 477-5313 (508) 273-0377 Of 20" DIA. COVERS NEMA 4 JUNCTION BOX CORROSION RESISTANT (TYP ) 12 -2 PROVIDE WATERTIGHT CONCRETE RISER WITH & LIQUID -TIGHT CABLE CONNECTORS SUPPORTED BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE SECURED FRAME &COVER TO GRADE WATERTIGHT. AN SJE RHOMBUS -JB PLUGGER OR EQUAL IS RECOMMENDED. PROVIDE ENOUGH WIRE __FF REMOVE PUMP TO HOISTING CABLE 7x19 STAINLESS STEEL INSTALL 1' PVC CONDUIT TO HOUSE FOR WIRING I I I I 1/8" DIAMETER. / 1,760 LB. STRENGTH. WITH WATERTIGHT JOINTS. WIRE HIGH WATER ALARM A I I A (TO BE INSTALLED IF QUICK DISCONNECT IS NOT INSTALLED) FLOAT TO SJE RHOMBUS TANK ALERT XT ALARM PANEL ON CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. 6' -8 I i �� INV.(IN)=4.83 2" BALL VALVE (FIELD ADJUST FOR 20 GPM RATE) I O O (INSTALL QUICK DISCONNECT FOR EASY REMOVAL) 40 DISCHARGE (THROUGH RISER -SEE PROFILE) ALARM ON EL: 2.332"SCH. 2" 90' ELBOW W/ WEEP HOLE PUMP ON EL: 2.00 FOR SELF -DRAINING FORCE MAIN L- J - PUMP OFF EL: 1.50 18 14" 2" SWING CHECK VALVE BOTTOM OF PUMP CHAMBER 1 8" 2" SCH. 40 PVC DISCHARGE PIPE 4" KNOCKOUTS PLAN VIEW ELEV.= 0.50 ADDITIONAL 3/16" VENT HOLE (MIN.) ABOVE PUMP FLANGE (TYP.) PROVIDE 2 FLOATS: 4" (TO PREVENT PREMATURE PUMP BURNOUT) FLOAT N0.1: PUMP ON/OFF-SJ RHOMBUS (PROVIDED WITH PUMP) LIBERTY LE40 SERIES PUMP H.P. 115 V 4" 20" DIA. COVERS .4 FLOAT N0.2: ALARM ACTIVATION FLOAT -PROVIDED WITH ALARM PANEL VVlm 2" DISCHARGE, OR EQUAL (TYP ) (ON SEPARATE CIRCUIT FROM PUMP SPECIFIED) 5" PUMP CHAMBER, PUMP & ACCESSORIES AVAILABLE AS A UNIT "'" ``� ��'" CAPE WINWATER WORKS CO., HYANNIS, MA. (508) 862-0166 NOTE: APPROVED ALTERNATE MAY BE SUBSTITUTED. _ 4" INLET KNOCKOUTS ' 5'-8" C 4' OUTLET ;., 3" q!, PUMP DETAIL 4" KNOCKOUTS ): 4,7„ N.T.S. 4'-3" / SuPPORT LIQUID (SEE NOTE 3) 'i COMPARTMENT ` ALL AVAILAB :`, BT)S LEVEL% YF 5 4" BUOYANCY CALCULATIONS CROSS SECTION A -A H-10 SEPTIC TANK/PUMP CHAMBER WT of H-10: 18,852 LBS. BOTTOM OF UNIT EL.= 0.50 HIGH GROUNDWATER EL.=2.40 BUOYANCY FORCE PER FOOT OF DEPTH: SPECIFICATIONS 12.2' x 6.7' x 1' x 62.4 Ibs./cu.ft. = 5100.6 Ibs. 1.) CONCRETE 4,000 PSI AFTER 28 DAYS. MAX. DISPLACEMENT = 2.4' - 0.5' = 1.4' MAX. UPLIFT PRESSURE = 1.4' x 5100.6 Ibs/ft = 7140 Ibs. EXIST/NG, 2.) CONSTRUCTION CONFORMS TO DEP TITLE V REGS. WEIGHT OF UNIT EMPTY = 18,852 s. DECK HOUSE(124) 310 CMR SECTION 15.226. 3.) TONGUE &GROOVE JOINT SEALED WBUTYL RESIN 18,852 Ibs > 7140 Ibs O.K. \�\\ 4.) REINFORCEMENT PER ASTM C1227-966 . back Of house 5.) ALSO AVAILABLE IN H-20 LOADING. 23.0' 6) PRVIDE POLYMER WATERPROOF COATING shr DOSING & STORAGE REQUIREMENTS ?��' 345. H-10 SEPTIC TANK/PUMP CHAMBER 1500/500 WIGGIN PRECAST CORP., BOURNE MA. (800) 564-6774 DESIGN FLOW: 220 GPD (DAILY FLOW -220 GPD) DOSING REQUIRED: 4 CYCLES/DAY (SAND) u O rp TN 9 3>1 - 220 _ 4 = 55.0 GALLONS/CYCLE CV DISTANCE REQUIRED BETWEEN PUMP j PROPOSEINN PROPOSED SEPTIC SYSTEM UPGRADE PLAN ON AND PUMP OFF FLOATS:�- 55.0 GAL/CYCLE _ 125 GAL/FT = 0.44 FT/CYCLE (SAY 6") S.A_S. - =25� 24 ANGUS AVENUE, SOUTH YARMOUTH, MA Prepared for: Loren Montgomery, 9 Parkway Drive, Saugus, MA 01906 STORAGE REQUIRED ABOVE WORKING LEVEL: 220 GALLONS STORAGE PROVIDED: WV.(IN) EL: 4.83 - PUMP ON EL: 2.00 = 2.83' Engineers: Surveyors: SCALE DRAWN JOB. NO. STORAGE PROVIDED = 2.83' x 125 GAL/FT = 353.8 GALLONS SEPTIC LAYOUT Engineering Works, Inc. 12 West Crossfield Road JC Engineering, Inc, 2854 Cranberry Hwy. N.TS. P.T.M. 220-20 DATE CHECKED SHEET NO. Forestdale, MA 02644 E.Wareham, MA 02538 (508) 477-5313 (508) 273-0377 7/29/20 P.T.M. 3 Of 3