HomeMy WebLinkAboutEngineer Plans - 2021peroit villid for REPAIR OF SEPTIC SYSTEM LEGEND
ONLY. d to Stats and Local septic variaacea.
P� r90 pc 7g Burd of iealtb review and approval is required for 67 EXISTING CONTOUR
aay future additionslrenovations/alteratiOu to x 100.98 EXISTING SPOT GRADE
sewage t#oi ities and/or structures/dwelling. OVERHEAD WIRES
EX/STING SEPTIC TANK Yarmouth HeaNh Department EXISTING GAS SERVICE e ; .• t.
TOP OF TANK, EL.=98.45 APPROVED W EXISTING WATER SERVICE
INV.(OUT)=97.10± TEST PIT
S 10°48'35" E
r f-lr4 Vit? ? ?� 2 BENCHMARK i
X_
104.04 ' i Q 11 NaeDate
@,SIsLl7 V I_ U
100,8 �--12.8'--{
LOT J8 f SHED '°` �'_-��-� SEP 28 2021
t PROPOSED S.A.S.
12,388±S.F. r
3
f'; ..` 1 3-500 GAL CHAMBERS HEALTH DEPT,
r----------------- x :':::� SURROUNDED W/4' STONE LOCUS MAP
100.44 I 100.51 I 1 NOT TO SCALE
I
X Ex. S.A.S. ,`" 99.2 O -'`�� GENERAL NOTES:
i
L-------------- -----J 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
TP t:: ": 1 APPROX. L OCA T/ON OF
EXIST/NG S.A.S. r r':` �` ''`I ORIGINAL LEACH PIT BOARD OF HEALTH AND THE DESIGN ENGINEER,
100 04` TO BE REMOVED 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
TO BE ABANDONED vpC�'- (.:.: N
j SEE NOTE 11 OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW:
100,06 '0 0 �-�-+�10' T -310 CMR 15.405(1)(b): LOCAL UPGRADE APPROVAL
BENCHMARK 1) A 5' variance, SAS to cellar wall(bulkhead), for a 15' setback. .%
w I 99,63 BULKHEAD CORNER 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
4 x x 99.26 EL.=100.29 TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
X 100.53 9,79 _ �J DESIGN ENGINEER.
N M 100,29 N
l BH 99,49 O 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
r
0) 9970 `_ 99,65 x x '�! OF Mq FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
p�QN�� SSq�� ENGINEER BEFORE CONSTRUCTION CONTINUES.
/� ` ' ` %/'✓� oPETER T. s 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM.
zfjEXISTNGy McENTEE C.11)
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
99,63 99,06 v v CIVIL THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HOUSE(1185) �' O, x `"' No. VIL HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
GARAGE
fT.O.F.=0./STEO 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 150' OF THE PROPOSED S.A.S.
99,57 ' 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
X ` „ y AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
x 99,9899.6 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
tis� THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
Fi
,r� �, Lll?IVEWAY 99,84 G2,�r�1H �ChG CONSTRUCTION.
o 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
0 -
�, IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
99.39 x''<�9.98 x 3
0�� REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
x 100,28 0�0. O6� 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
O INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
99 37 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
"a'39,071',: 102.48'ss/0 ASS NOT CONSIDERED TO BE A PROPERTY LINE SURVEY,
IRDNPIP N 10°48'35" W `1z?0...... 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC
SYSTEM COMPONENTS NOT SHOWN ON THE PLAN
4 -- -r 100.17 MAP ID: 78-257
98,54 98,86 99,40 edge 99.79 of Pavement 99,97 PROPOSED SEPTIC SYSTEM UPGRADE PLAN
85 WITCHWOOD ROAD, SOUTH YARMOUTH, MA
Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673
WITCHWOOD ROAD OWNER OF RECORD Engineers: Surveyors: SCALE DRAWN JOB. No.
PIERRE, YOLENE Engineering Works, Inc. JC Engineering, Inc. 1 "=20' P.T.M. 235-21
12 West Crossfield Road 2854 Cranberry Hwy.
85 WITCHWOOD ROAD Forestdole, MA 02644 E.Wareham, MA 02538 DATE CHECKED SHEET NO.
SOUTH YARMOUTH, MA 02664 (508) 477-5313 (508) 273-0377 8/31/21 P.T.M. 1 Of 2
.EXISTING SEPTIC TANK
PROVIDE RISERS WITH COVERS OVER INLET &
OUTLET MANHOLES SET TO 6" OG FINISH GRADE.
T.O.F.=100.4±
-F.G. EL.=99.6±
EXISTING
1
F.G. EL.=100.0±
1 14
48" LIQUID
LEVEL ADD GAS
I BAFFLE
EXISTING SEPTIC TANK
NOTES:
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE
INVERTS, PRIOR TO INSTALLATION.
2) D -BOX SHALL BE SET LEVEL AND TRUE TO
GRADE ON A MECHANICALLY COMPACTED STABLE
BASE OR 6" AGGREGATE BASE, AS SPECIFIED IN
310 CMR 15.221(2).
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.
PROPOSED D -BOX
INSTALL RISER & COVER
SET TO 6" OF GRADE
L=37'
0 S=1% (MIN.)
4"SCH40 PVC
F.G. EL.=99.3±
L = 5'
S=1% (MIN.)
4"SCH40 PVC
' 2' EFF.
DEPTH
PROPOSED
INV.=96.40 D BOX INV.=96.23
-INV.=97.10 3 OUTLETS
(VERIFY) H_20 INV.= 96.00•
TOP CONC. ELEV.= 96.8± -
BREAKOUT ELEV.= 96.50 -
INV. ELEV.= 96.00-
BOTTOM ELEV.= 94.00-
4' OF NATURALLY OCCURRING
PERVIOUS MATERIAL
5' (MIN.) ABOVE G.W.
NO GW, EL.=88.2
NOTE: TO PREVENT BREAKOUT, THE PROPOSED
FINISH GRADE SHALL NOT BE < EL. 96.5
FOR A DISTANCE OF 15' AROUND THE
PERIMETER OF THE S.A.S.
PROPOSED S.A.S.
INSTALL RISER & COVER OVER ONE CHAMBER AND
SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT
r F.G. EL.=99.2±
MAINTAIN 2% SLOPE OVER S.A.S.
1
4' 4.8' 1 4'
EFFECTIVE WIDTH = 12.8'
2" LAYER OF 1/8" TO 1/2"
DOUBLE WASHED STONE
-3/4" TO 1-1/2" DOUBLE
WASHED STONE
3-500 GALLON LEACHING CHAMBERS
SURROUNDED WITH STONE AS SHOWN
H-10 RATED 3" LAYER OF 1/8- TO 1/,'
DOUBLE WASHED STONE
4' 1 3 x 8.5' = 25.5' 1 4'
EFFECTIVE LENGTH = 33.5'
SEPTIC SYSTEM PROFILE
DESIGN CRITERIA
NUMBER OF BEDROOMS: 4
SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF)
DESIGN PERCOLATION RATE: <2 MIN/IN
DAILY FLOW: 440 GPD
DESIGN FLOW: 440 GPD
GARBAGE GRINDER: NO -not allowed with design
LEACHING AREA REQUIRED: (440 GPD) = 594.6 SF
.74 GPD/SF
EXISTING SEPTIC TANK: 1500 GALLON CAPACITY
PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED
USE 3-500 GALLON LEACHING CHAMBERS IN SERIES
SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES
SIDEWALL AREA: 2(12.8' + 335) x 2 = 185.2 S.F.
BOTTOM AREA: 12.8' x 33.5' = 428.8 S.F.
TOTAL AREA:..............................................................614.0 S.F.
DESIGN FLOW PROVIDED: 0.74 GPD/SF(614.0 SF) = 454.4 GPD
LEACHING SYSTEM SECTION
3/4" TO 1-1/2" DOUBLE
WASHED STONE
SOIL LOG
DATE: JULY 29, 2021
SOIL EVALUATOR: PETER McENTEE PE, SE -1542
WITNESS: PHIL RENAUD HEALTH AGENT
ELEV. TP DEPTH
99.2 A 0"
98.4
96.4
LOAMY SAND
10YR 4/2
B
LOAMY SAND
10YR 5/8
C1
MED. SAND
10YR 5/6
C2
M -F SAND
10YR 5/3
1%
34"
PERC
26"/44"
88.2 132"
PERC RATE 2 MIN/IN. ("C' HORIZON)
NO GROUNDWATER ENCOUNTERED
SEPTIC LAYOUT
t -1t ►-� t-� ►-� ►- ►►=1 tt-t tt-1 t-� t-�
� t f t_i1 t_f 1 1_1 M I 1__1 M I t f t__1 1__f 1 f
� t_I t_I _� ►_I t_� ►_� t= t-1 t-1 t-1 t-�
58"
500 GALLON CAPACITY, H-10 LOADING
CHAMBERS
N.T.S.
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
85 WITCHWOOD ROAD, SOUTH YARMOUTH, MA
Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673
Engineers: Surveyors: SCALE DRAWN JOB. NO.
Engineering Works, Inc. JC Engineering, Inc. N.T.S. P.T.M. 235-21
12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET N0.
Forestdole, MA 02644 E.Woreham, MA 02538
(508) 477-5313 (508) 273-0377 8/31/21 P.T.M. 2 Of 2
4" KNOCKOUT
20" DIA. COVER
4" KNOCKOUT0 / 4" KNOCKOUT
4" KNOCKOUT
58"
500 GALLON CAPACITY, H-10 LOADING
CHAMBERS
N.T.S.
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
85 WITCHWOOD ROAD, SOUTH YARMOUTH, MA
Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673
Engineers: Surveyors: SCALE DRAWN JOB. NO.
Engineering Works, Inc. JC Engineering, Inc. N.T.S. P.T.M. 235-21
12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET N0.
Forestdole, MA 02644 E.Woreham, MA 02538
(508) 477-5313 (508) 273-0377 8/31/21 P.T.M. 2 Of 2