Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2021 Sign off Transmittal - New 2 story Ggarage
GENERAL NO TES: 1. HOUSE NUMBER: 166 2. ASSESSORS INFORMA770N MAP 23, PARCEL 347, LOT 45 3. FLOOD ZONE.- X (0.29) (FEMA MAP 250015 0588 ✓, 7116114) 4. ZONING DISTRICT• R25 5. LOT COVERAGE BY - A. EXISTING S7RUCTURES 2,052 S.F.1 18,392 SF. = 11.2% B. EXIS77NG & PROPOSED STRUCTURES: 2,527 SF.1 18,392 S.F. = 13.7.8' 6. TOPOGRAPHIC INFORMATION COMPILED FROM AN ON THE GROUND SURVEY 7. ELEVATIONS SHOWN ARE BASED ON NORTH AMERICAN VERTICAL DATUM 70 O 5 10 20 SCALE 1 /NCH = 70 FEET "PLAN REVISIONS" 1 1 9122121 ADD PROPOSED ADDITION. L.A! NO, I DAZE DESCRIPTION BY PA/PR DRANN BY- LM., R.JW DA 7r. 5117121 CHECKED BY GSL SYEET 1 OF 1 P.kLond Projects 2004jSS21020dw91SS21020SP.dw9 SPRINGER Z P OF BOUND 12.74 CB/DH FOUND (40' WIDE) LANE EGEND ----12 - x 13.5 PP -0 /DH p UND LOCUS MAP Nor TO SCALE EXISTING 2' CONTOUR EXISTING SPOT ELEVATION EXIS77NG UTILITY POLE CONCRETE BOUND WITH DRILL HOLE SITE PLAN ncH III IJEPT FOR FRANK & MARY ELLEN ZAPPULLA #166 SPRINGER LANE WEST YARMOUTH, MA Scale: l "=10' Date: MAY 17, 2021 TYarwick & Associates Inc. 63 County Road Box 80> North Falmouth, Jfass 02556 (508) 563 - 7777 QS SMOKE DETECTOR UC CARBON MONOXIDE DETECTOR (3 HEAT DETECTOR FIRST FLOOR PLAN LEGEND: � EXISTING WALLS 17--� L.-- -i CONSTRUCTION TO BE REMOVED 1=1 NEW CONSTRUCTION N a) CD [ECC2018 RESIDENTIAL ENERGY EFFICIENCY DETAILS CLIMATE ZONE 51 (USE EITHER PRESCRIPTIVE VALUES OR RESCHECK CALCULATION TAB I LE 402.1 ,2 (MINIMUM PRESCRIPTIVE INSULATION & FENESTRATION REQUIREMENTS) FENESTRATION --FACTOR SKYLIGHT U-FACTQP CEILING R -VALUE IftOOD FP,AMED WALL R -VA -I -E FLOOR R -VALUE I BASEMENT WALL R -VALUE I BASEMENT SLAB R,VALUE 1 CRAWL SPACE WALL R -VALUE 0,30 N'A AIdSMSEND 1055 1 49 1 20o,13-5. 130 15/19 7014 FT. DEEP) 15/19 NOTES: 1. R -VALUES ARE MINIMUMS & U -FACTORS ARE MAXIMUMS, 2.16/19 MEANS R=15 CONTINUOUS INSULATED SHEATHING ON THE INTERIOR OR EXTERIOR OF THE HOME OR R=19 INSULATION CAVITY AT THE INTERIOR OF THE BASEMENT WALL 3. REFER TO JECC 2018 CHAPTER 4 FOR ALL INSULATION & ENERGY REQUIREMENTS 4,13 + 5 MEANS R5 CONTINUOUS INSULATED SHEATHING ON THE WALL EXTERIOR & R13 CAVITY INSULATION ry 0 H (D Z 0 W < 0 0 w ui w ry w z Z w z< 0 w w r Y (.0 < z n W CIL cfl Z to T- 1/411 DATE: 101612021 Al U _I 8 J ----------------------------� A8 Z' { ' jE LLI Q CO 4crq 1'-6' k 20._0,;.. -vT' l� ul 00 ROOF. I. 'I BELOW.: i Q13, m Q 60' x 2'0•`. MULLED AWNING. TEMPERED El o TUB/S OWER 4'x 6s TILED ❑ _ �, HW EXIST. NEW .D BATH EXIST. BATH BEDROOM r _ - I to LIN. � LIN, NEW r EXIST. 2'6"x4'5 W.I.C. BEDROOM 26 �6---- ---- — ---- HALL QQ µ. DOUBLEHUNG I _, DN. Y _ II EXIST: %0 II _. BEDROOM J N e M � 2'6 x45" 12'-5, �+ 1 1 1 DOUBLEHUNG - CLOS. LLQ iv 0. (VAULTED. CEILING) /+� ACCESS �-- PANEL V W. NEW W W OFFICE! W STUDY W Z 76 x 3 5... 2 6" x 3,5, IN DOUBLEHUNG DOUBLEHUNG `A �ryw 5. /00&7' q (✓ A8 A8 © J Z A8 Q o'_ 2'6,'.x 4'5' 1"1 co DOUBLEHUNG LL. ,t ;G Mss SCALE: 1/4 1'-0 l7 ERIC J. CEDENHDLMm 0 STRUCTURAL N DATE SECOND F LOO R PLAN 3a96� 10/612021 New f JUL 302020 IHEALTH DEPT, EXIST. BEDROOM �I 0 O EXIST. BEDROOM w :Ik EX15T. EXIST. C(C (EXISTING) 20- 10" 20'_2'+ N (ADDITION) (EXISTING) Z Lo 3,_4,. 3'_4" 3.4° 3,_4" G, ABOVE ABOVE UA151OVE©� 1 2 Q w G x G 2J 2J 2J 2J G x G 3JK W A PSL W/IJ PSL W/IJ 2 1 n '3K �IANDERSEN IJ FWG GOG8 w 31 2_ d ❑0 z 4'_2„� ;NEW o O o ° 4 2J GREAT I Q m 12 ROOM 21 I; I It PATIO o o v o A 'VAULTED f , CEILING) W CJ 41 8” 0 OO K Lo E�iPAN I ED z o PANTRYo EXIST. - _NEW W-1 2 x 87 S_ TEFL BEAM ABOVE (VERIFY LOCATION IN WALL IN. FI O IY1 FLD) - ', .- ;EXIST. EXIST. EXIST. Q . �� 1 j C] cv `I �� 4" x 1 /4" y jj�F HSS 4" x 4" x ! /4" Q . 7 STEEL COLUMN STEEL COLUMN X EXIST. z Q EXIST. i BATH i ROOM DINING ---- w pLU 10 Room o F- a oa ST '¢2 O 1 EXI T. EX15T. CLS. LIVING ROOM I I EXST. CI FI [QST FLOOD PLAN LEGEND D EXISTING WALL CONSTRUCTION TO REMAIN O NEW WALL CONSTRUCTION C-� EXISTING WALL CONSTRUCTION TO BE REMOVED Q NEW/EXIST. SMOKE/CARBON MONOXIDE DETECTORS ® NEW/EXIST. HEAT DETECTOR (DBYY THOMAS2A.. MOORE DESIGN CO. EX15T. GENERAL NOTES: EXIST. KITCHEN EXIST. ® EXIST. cj� DN. GARAGE � � N� � N� L) z EX15T. 1 EXIST. O 01 ILILNENI BATH Q '� Q (EXISTING) } EXIST. tl O - --- ox (� N W ^ IST. NOTE: T i'iE F -.5 SH6 Yie ARE THE SOLE PROPERTY OF THE DE5IGNER AND CAN NOT BE COPIED. REPRODUCED AND/OR :. ALTERED WITHOUT THE EXPRE55 WRI T I� EN CON5ENT OF THE DE51GNER (EXISTING) SCALE: 1/4" = 1'-0" DATE 1.) CONTRACTOR 15 TO VERIFY EXISTING CONDITIONS AND 5.) ANY DISCREPANCIES, ERRORS AND/OR OMI55ION5 IN THE NOTES, 6/29/2020 DIMENSIONS IN THE FIELD PRIOR TO THE START OF WORK DIMENSIONS, AND/OR DRAWINGS CONTAINED ON THESE DOCUMENTS PROD. NO.: 2.) CONTRACTOR TO REMOVE EXISTING DOORS, WINDOWS, SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER PRIOR TO WALLS, 4� ROOFING AS REQUIRED FOR NEW CONSTRUCTION. COMMENCEMENT OF CONSTRUCTION. PROCEEDING WITH CONSTRUCTION 2020-011 CONSTITUTES ACCEPTANCE OF THESE DOCUMENTS AND ANY DISCREPANCIES, 3,) ALL NEW CONSTRUCTION TO MATCH EXISTING IN MATERIAL, ERRORS AND/OR CM15510N5 BECOME THE RESPONSIBILITY OF THE STAMP: DWG. NO.: DETAIL, AND FINISH. BUILDING CONTRACTOR, 4.) ALL WORK SHALL CONFORM TO THE MA55ACHU5ETT5 STATE BUILDING CODE (LATEST EDITION) AND ALL OTHER APPLICABLE LOCAL CODES 0 5 10 15 20 NI 0� FOUNDATION PLAN NOTE: FOUNDATION CONTRACTOR TO PROVIDE 5/8" DIA. ANCHOR BOLT5 AT 39" o.c. ON UPPER WALL AND 25" o.c. ON LOWER WALL WITH MINIMUM EMBEDMENT OF 7" INTO CONCRETE. ALL SILL PLATE5 TO BE CONNECTED U5ING 3"x3"x 1/4" SQUARE PLATE WA5HER5. NEW/EXIST. SMOKE/CAR80N MONOXIDE DETECTORS ©BYY THOMA5 A. MOORE DE51GN CO. THE PLANS 5110MN ARE THE 50LE PROPERTY OF THE DESIGNER AND CAN NOT EE COPIED. REPRODUCED AND/OR ALTERED WITHOUT THE EXPRE55 WRITTEN CON5EN`-1 Of THE DE51GIIER SCALE: 1/4" = Y-0" DATE: 6/29/2020 2020-011 DWG. NO.: 11 CV Z — W N z W � C7 W U1 Q L_•1 Z C�3 ti Co CO m Q W Q ,C) 00 oo o ¢ Q zQx U N °� W 3 C/) c/�) QI . M�y� W THE PLANS 5110MN ARE THE 50LE PROPERTY OF THE DESIGNER AND CAN NOT EE COPIED. REPRODUCED AND/OR ALTERED WITHOUT THE EXPRE55 WRITTEN CON5EN`-1 Of THE DE51GIIER SCALE: 1/4" = Y-0" DATE: 6/29/2020 2020-011 DWG. NO.: 11 LEGEND $ SINGLE POLE SWITCH %,I -,,'CONCEALED CONDUIT (TYPICAL) DUPLEX RECEPTACLE (TYPICAL) ® FLOOR MOUNTED DUPLEX RECEPTACLE ©v CABLE TV RECEPTACLE (TYPICAL) 0 ETHERNET OUTLET (TYPICAL) Q -I WALL MOUNTED INCANDESCENT FIXTURE (TYPICAL) O RECESSED INCANDESCENT FIXTURE (TYPICAL) SURFACE MOUNTED FLOODLIGHT (TYPICAL) SURFACE OR PENDANT MOUNTED CEILING FAN NOTES : I .) THE ELECTRICAL PLANS SHOW NEW GENERAL PURPOSE LIGHTING, SWITCHING AND OUTLETS ONLY. THE ELECTRICAL CONTRACTOR 15 RESPONSIBLE FOR THE ENTIRE EXIST./NEW ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL STRICTLY ADHERE TO ALL STATE, FEDERAL AND LOCAL CODES THAT APPLY, 2.) THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL EXIST./NEW OUTLET, SWITCH AND LIGHT LOCATIONS IN THE FIELD W/ THE OWNER PRIOR TO WALLBOARD INSTALLATION. �. 3.) ALL RECESSED LIGHTING SHALL BE ON DIMMER SWITCHES. VERIFY W/ OWNER IF OTHER LIGHTS ARE TO BE ON DIMMERS. Z 4.) THE ELECTRICAL CONTRACTOR 15 TO PROVIDE ALL RECESSED LIGHT FIXTURES_ THE OWNER SHALL PROVIDE ALL OTHER LIGHT FIXTURES TO BE INSTALLED BY THE ELECTRICAL CONTRACTOR. Q Q, C] -- C/) © SMOKE/CARBON MONOXIDE DETECTORS a z ® HEAT DETECTOR ~ O NEW I / �E G° ROOM N >- N w 0 d N w m o�W Q�Q Q � w EXPANDED PANTRY ------ NEW STEEL BEAM ABOVE - - - -- -- I EXIST.EXIST., CLO5 i; EXIST. EX15T. I BATT 1 ��TV/DEN I DINING ROOM ROOM BEDROOM moi,d o0 0 EXIST. BEDROOM 2020 A. MOORE DESIGN CO. ti EXI15T CL 5. EXIST. CLO. EX15T. LIVING ROOM EX15T. KIT('HFt\i ELECTRICAL PLAN co C) OZQ0 op Q O CD U -j W ...7 O 6' CV W O�w Q O NOTE: THE PLAN5 SHOWN ARE Tyt 50 1.__ PROPERT, n_,F THE DE51GNER AND CAN NOT BE COPIED, REPRODUCED AND/OR ALTERED WITHOUT THE EXPRE55 WRITTEN CONSENT OF THE 1/4" = F-0" TIATF . 6/29/2020 PROD. NO.: 2020-011 DWG. NO.: a z ~ O N >- N w 0 d N w m o�W Q�Q Q � w NOTE: THE PLAN5 SHOWN ARE Tyt 50 1.__ PROPERT, n_,F THE DE51GNER AND CAN NOT BE COPIED, REPRODUCED AND/OR ALTERED WITHOUT THE EXPRE55 WRITTEN CONSENT OF THE 1/4" = F-0" TIATF . 6/29/2020 PROD. NO.: 2020-011 DWG. NO.: L,or- F,cWT: 1P oo+ '10 w Fvv'X?ry 0 COMIGHT 2020 BY THOMA5 A. MOORE DE51GN CO. r ---ti Fir - r -1- Z j r -T-71 - 1 ! i r --1--C L _ t i! D;P"-i rim y L H# IV 1W.-49 .-Q n ARE z ~' � cb RECEIVE® ¢ o M MAY 18 202 ? A 7 cq YARMOUTH w U) >< W OLD KING'S HIGHWAY�i Z Q En 0 2 ao 3 APPROVED w $ o w JUN Q 8 2020 YARMOUTH Q OLD KING'S HIGHWAY E+ RECCIV o F-4 R JUN 17 p SOU 0 a �Uw CV SCALE: A5 NOTED DATE : 3!5/2020 PROD. NO. 2020-011 DWG. NO. Le- 544 - .►-^-- 10,3o(I 1 fATIP — I 0 COMIGHT 2020 BY THOMA5 A. MOORE DE51GN CO. r ---ti Fir - r -1- Z j r -T-71 - 1 ! i r --1--C L _ t i! D;P"-i rim y L H# IV 1W.-49 .-Q n ARE z ~' � cb RECEIVE® ¢ o M MAY 18 202 ? A 7 cq YARMOUTH w U) >< W OLD KING'S HIGHWAY�i Z Q En 0 2 ao 3 APPROVED w $ o w JUN Q 8 2020 YARMOUTH Q OLD KING'S HIGHWAY E+ RECCIV o F-4 R JUN 17 p SOU 0 a �Uw CV SCALE: A5 NOTED DATE : 3!5/2020 PROD. NO. 2020-011 DWG. NO.