Loading...
HomeMy WebLinkAboutEngineer Plans - 2021retail valid for REPAIR OF SEPTIC SYSTEM ONLY, due to State mad Local septic variance& 100.84 LEGEND �v - 67 -- EXISTING CONTOUR Heard of Health review and approval is required additions/renovations/atterationa for to t x 100.98 EXISTING SPOT GRADE -8.11 {tF- OVERHEAD WIRESIlls any future stractoresldwetling. I' sewage facilities andlor G - EXISTING GAS SERVICE' CB - Yarmouth HealthDeparlmeut 10112 -1/il- EXISTING WATER SERVICE Y APPROVED .. " TEST PIT D BENCHMARK OOJB rn100.48� \ /d Z t 10159 �^ LOCUS MAP _ GENERAL NOTES: NOT To SCALE �` 6 � ... 101.41 -e 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL \\ S 10009 �" ddd... BOARD. OF HEALTH. AND THE DESIGN ENGINEER. 100.40 70 101.6 x� 2 UREENTS WK MATERIALS SHALL ON TO THE �k0 ^ryh• TORE V, AND ANM Y AIPPLICABLE OF HOER STATED ENVIRONMENTAL COD /10379 103,118 // l LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: 'r } /\ -310 CMR 15.405(1)(b)&(h): LOCAL UPGRADE APPROVAL / C) / LOT 41 99.69 1) A 1' variance to the 3' maximum cover requirement, for up to/ 1 2.58 4' of max. cover. S.A.S. shall be H-20 and vented. 12,195 Bf 2) A 1' reduction to the 5' separation requirement between estimated CB high groundwater and bottom of S.A.S., for 4' of separation. J \ 102.0'1 'X GARAGE - �Q x 100 76 ( 9.60 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR f� TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THEIN J DESIGN ENGINEER. �A' �.' / 0 \ 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN iB x ti0 I / �(�y - ENGINEER BEFORE CONSTRUCTION CONTINUES. 71AL 10099 x 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. ` 102,53 VENT CO '� \ '` HOUSE(7f9) 9 �#� 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF \N- 7.0. F.=103.8/ ,_ HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. X 100.664LwGLs��/LU BY TOWN WATER SERVICE. 100.89 101.25 �` � O,p Y2�� `�`e, DECK 7. WATER SUPPLY PROVIDED s OCTrt 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. C 19 mi 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE �p HEALTH DEPT. DIRECTED BY THE APPROVING AUTHORITIES. 1.6 104 Bh,. 00ro 10057 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY O THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING 01'.32 N BM p• .O OF ,4 CONSTRUCTION. S'r94, 1OL01 i 4 4 x x °� ��`� 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS yG PROPOSED S.A.S. x S �S �� 100.63 Mry 'ts`' IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND } : PETER T. �, REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 6' x 30' LEACH FIELD Oss 00' McENTEE H \ WITH 3 DISTRIBUTION LINES �O' v x v CIVIL 2. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE 100,62 Na. 35tos INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. ENCHMARK V COR. ULKHEAD13. THIS PLAN IS TO BE USED FOR SEPTIC PURPOSES ONLY AND � NOT CONSIDERED TO BE A PROPERLY LINEE SUR SURVEY. EL.=102.81 \ EXISTING S.A.S. TP _ 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC TO BE ABANDONED SYSTEM COMPONENTS NOT SHOWN ON THE PLAN.. eV "100.98 PROPOSED SEPTIC SYSTEM UPGRADE PLAN EXISTING SEPTIC TANK 9 DEERFIELD ROAD, WEST YARMOUTH, MA TOP OF TANK, EL.=99.36 INV.(OUT)=98.001 Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 CBOWNER Engineering by: SCALE DRAWN JOB. NO. MAP 1D: 23-297 OF RECORD 01.62 COLEMAN GLORIA P Engineering Works, Inc. 1"=20' P.T.M. 247-21 NOTE: HOUSE LOCATION TAKEN FROM CERTIFIED PLOT PLAN BY 745 WACHUSETT STREET 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. DOWN CAPE ENGINEERING, INC., YARMOUTHPORT, MA, DATED 2/14/1977 HOLDEN, MA 01520-2508 (508) 477-5313 8/31/21 P.T.M. 1 Of 2 SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & OUTLET AND SET TO 6" OF FINISH GRADE T.O.F EL.=103.8± -E.G. EL.=101.7± EXISTING F.G. EL.=101.3± 48" LIQUID LEVEL ADD GAS RAI PROPOSED D -BOX INSTALL RISER & WATERTIGHT COVER SET TO 6" OF GRADE L=20' *S=1% (MIN.) 4"SCH40 PVC NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION. 2) D—BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED STABLE BASE OR SIX INCH AGGREGATE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF—HTE, ZABEL OR EQUAL, DESIGN CRITERIA F.G. EL.=101.0± L = 7'(MAX) @S—I% (MIN. 4"SCH40 PVC INV. =97.62) PROPOSED `INV.=97.45 V.=98.00± D -BOX Vic-nnir_ INV.=97.35 r BREAKOUT ELEV.=97.50 BOTTOM ELEV.=96.70✓ 4MIN. SEPARATION TO G.W. AND 4' OF NATURALLY OCCURRING PERVIOUS SOILS LN:ti EST. HIGH G.W. EL: 92.5` NOTE: TO PREVENT BREAKOUT, FINAL GRADE SHALL NOT BE AT, OR BELOW, EL.=97.5 FOR A DISTANCE OF 15' FROM THE EDGE OF THE PROPOSED S.A.S. PROPOSED S.A.S. INSTALL INSPECTION PORT OUTSIDE DRIVEWAY FOOTPRINT VEN T 11 /MAINTAIN EL.=101.0f CONNECT ALL ROWS / MAINTAIN 2% GRADE (MIN.) OVER S.A.S. CAP )PE OF PERF. PIPE = 0.5% `INV. EL.=97.20(END) 30' EFFECTIVE LENGTH ESTABLISH VEGETATIVE COVER FINISH GRADE EL.=101.0± --I APPROVED FILTER FABRIC 16' EFFECTIVE WIDTH SOIL ABSORPTION SYSTEM (SECTION) SEPTIC SYSTEM PROFILE NUMBER OF BEDROOMS: 3 SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: 8 MIN/IN (0.66 GPD/SF) DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF ./4 GF'U/JF EXISTING SEPTIC TANK: 1000 GALLON CAPACITY PROPOSED D -BOX: 1 INLET, 3 OUTLET (MIN.), H-20✓ INSTALL AN 4- x 30' LEACH FIELD SIDEWALL AREA: NOT APPLICABLE BOTTOM AREA: 16' x 30' = 4AU S.F. TOTAL AREA: .................................... 415D S. F. LEACHING CAPACITY = 0.74 GPD/SF x `ego SF = X93..6 GPD SOIL LOG DATE: JULY 29, 2021 SOIL EVALUATOR: PETER McENTEE PE, SE -1542 WITNESS: PHIL RENAUD HEALTH AGENT ELEV. TP DEPTH 100.6 -A - LOAMY SAND OYR 5/2 99.7 B LOAMY SAND 10YR 5/6 97.6 C1 MED. SAND 10YR 6/4 92.7 C2 COARSE SAND IOYR 7/2 92.5 ADJ. G.W. 92.1 o" 11" 36" PERC 26"/44" 95" 97" REDOX 7.5YR 5/8 102" 90.6 120" PERC RATE 2 MIN/IN. ("C" HORIZONS) GROUNDWATER ENCOUNTERED AS NOTED 1/2' DOUBLE STONE S.A.S. LAYOUT PROPOSED SEPTIC SYSTEM UPGRADE PLAN 9 DEERFIELD ROAD, WEST YARMOUTH, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. N.T.S. P.T.M. 247-21 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 8/31/21 P.T.M. 2 Of 2