HomeMy WebLinkAboutEngineer Plan - 2021SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 11.0' I. EL. 11.2' MINIMUM .75' OF COVER OVER PRECAST PRECaT H-10 WATERTEST D'BOX RtSERS 2'0 �P'1 9.81 FOR LEVELNESS 4"6SCH40 PVC PIPES LEVEL 1ST 2' "*EXISTING 1000 GAL.. 10" SEPTIC TANK 14' 8.73' TEE TEE *8.48' GAS 8.34' 8.17' 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) M MARK CORNERS OF + �� �e v CD NOTES LEACHING FIELD W/ ENGINEER: DANIEL E. GONSALVES, SE #13587 C m � REBAR SET 4" BELOW INSPECTION PORT (SEE DETAIL) WITNESS: PHIL RENAUD 1. DATUM IS NAVD 88 GRADE � A Ait Rd a DATE: 9/1/21 CD el w 50Jth < 2 MIN INCH PERC. RATE _ _ / 2% SLOPE \ LOT 77 0 2. MUNICIPAL WATER IS EXISTING O FILTER FABRIC \\ CLASS SOILS coo TOP 8.33' o i 4 ELEV. 1 3. MINIMUM PIPE PITCH TO BE 1/8- PER FOOT. 10' 1. FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ, l � 1 r AVSD DRIVE 4. DESIGN LOADING FOR ALL PROPOSED PRECAST -7'T FT_Ejj:jE'1�fi!� ! UNITS TO BE AASHO H -1L, CLEAN FILL - �! 5. PIPE JOINTS TO BE MADE WATERTIGHT. 4' PERFORATED PVC 5' O.C. S-+•- =G.OD5 ° - - 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE 3/4"-1-1/2" DOUBLE WASHED 0 WITH 310 CMR 15.000 (TITLE 5.) 8" STONE LEACHING FIELD o - 6"DEPTH MIN BELOW INV. 07. 7'85 THIS PLAN IS FOR PROPOSED WORK ONLY AND LEVEL BOTTOM o NOT TO BE USED FOR LOT LINE STAKING OR ANY ✓J- i ����� ��/� ����ii , �_ _ OTHER PURPOSE. ( R SLOPE) (-!-% SLOPE) FOUNDATION- EXIST. - SEPTIC TANK 14' D' BOX 19' LEACHING FACILITY *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- --- 99- EXISTING CONTOUR %- 99.7 EXIST. SPOT ELEV. -[99}-- PROPOSED CONTOUR 198.4) PROPOSED SPOT EL. TH1 TEST HOLE SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE' NOT ALL SYMBOLS MAY APPEAR IN DRAWING 0 0 � BENCHMARK: BOUND DISC =9.5' NAVD88 U 29.6' **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE JN R,0 ND t4 0J � \ 90.29 CIV __j a _� 1' TEST HOLE LOGS �� �e v CD Wow \ ENGINEER: DANIEL E. GONSALVES, SE #13587 C m � O 0lh A 4 _ WITNESS: PHIL RENAUD P a r� � A Ait Rd a DATE: 9/1/21 CD el w 50Jth < 2 MIN INCH PERC. RATE _ _ / Locus LOT 77 0 Sound O I� 10,361± S.F. CLASS SOILS coo o i 4 ELEV. 1 0„ 10.5' l � 1 r AVSD DRIVE FILL 16" A LS 1OYR 4/2 20" 8:83' B LS OYR 4/6 26" 8.33' C PERC MS 2.5Y 7/3 GROUNDWATER ADJ. DATA: WELL: MIW 29 ZONE: A ADJUSTMENT: 2.4' (AUGUST '21) VARIANCE REQUESTED (SEE NOTE) 120" I 10.5' GROUNDWATER ENCOUNTERED AT 108" EL.= 1.5' DICE #21-289 PA TAT 5. � TH1 Vim' S I � L f✓ � L� _ J In I EXISTING _ DWELLING TOF=11.2' DECK GARAGE _8416'30 W 29 6 Scale: 1"= 20' 0 10 20 30 40 50 FEET 0 _ 7.35' 5.0' ADJ. G.W. EL.= 2.3 0.5' BOT170M TH-1 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10 �e f orcin Wow c � � s - m � O 0lh A 4 _ � w P a a � A Ait Rd a � �' � Shore DI - el w 50Jth Locus Nantucket Sound 10. CONTRACTOR SHALL BE RESPONSIBLE FOR 33) AND VE FIYINGITHEFLOCATION F4ALL 2UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1"=2000'± Permit valid for REPAIR OF SEPTIC SYSTEM 11 ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ONLY, due to State and Local septic variances. BE REMOVED BENEATH AND 5' AROUND THE ASSESSORS MAP 26 PARCEL 56 Board of Health review and approval is required for. PROPOSED LEACHING FACILITY. any future additions/renovations/alterations to LOCUS IS WITHIN FEMA FLOOD ZONE AE sewage facilities and/or structure0dwelling. 12• EXISTING LEACHING FACILITY SHALL BE PUMPED (EL. 11') AS SHOWN ON COMMUNITY PANEL Yarmouth Health Department AND REMOVED OR PUMPED AND FILLED WITH CLEAN #25001 C0589J DATED 7%16/2014 SAND. APPROVED 13. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE FINAL INSTALLATION. MINIMUM OF 24 HOURS Zoz) NOTICE REQUIRED. (Viae Date cn LEACHING DETAIL (N.T.S.) BATH BR KITCHEN/DINING TIL. BR LIVING ROOM 1 ST FLOOR PLAN (N.T.S.) 2ND FLOOR PLAN (N.T.S.) e4 hr,47 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 **RE -USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: 440 GPD (.74) = 595 SF REQUIRED 597 SF X .74 = 442 GPD OK USE A 597 SF PIPE AND STONE LEACHING FIELD IN CONFIGURATION SHOWN. (SEE LEACHING DETAIL) VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1a): REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 5.0') & UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: REDUCTION IN GROUNDWATER ADJUSTMENT: USE 1.85' OF THE AUGUST 2.4' ADJUSTMENT TITLE 5 SITE PLAN OF 26 BURCH RD SOUTH YARMOUTH ' 2 a� h�isse HI PREPARED FOR cy ;�, ` : i ' CAN'EL STANLEY KOWALSKI DANIEL A. OJALA, P.E., P.L.S. DATE: SEPT. 20, 2021 I off508-362-4541 fax 508-362-9880 downcape.com down cape engineering, int. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 21-289 KOWALSKI.DWG