Loading...
HomeMy WebLinkAboutEngineer Plan - 2020LEGEND ?° ° VN gR°°K e o Rono - EXISTING CONTOUR EP N °! VO,hEa ° x 100.98 EXISTING SPOT GRADE 9P AN s2 N FPSS 11 PROPOSED CONTOUR o °RPS oT'oo 0 PROPOSED SEPTIC TANK F11 PROPOSED SPOT GRADE INFILTRATOR IM1530(OR EQUAL) a o ---O.H.Kms--- OVERHEAD WIRES 2oy! PROPOSED S.A.S.peas - G - EXISTING GAS SERVICE o m°� cP�aes c4- 4 ROWS OF 5 HI -CAPACITY H-20 INFILTRATOR UNITS ,o P° o ti OJ O -Wi- EXISTING WATER SERVICE VENT TEST PIT N 31°48'20" W ® BENCHMARK 9909 - 94.00' !2 100.94 fe stockade nce X x 101.07 LOCUS 31.3' -j--{ 13' T -r-- 1 1 _ o Permit valid for REPAIR OF SEY'1IC SYSTEM + �* LOCUS MAP F/ _ '' TP i i lOL ONLY. doe to Stale and i.oral septic variances. NOT TO SCALE • Iv _ T - 7 -1 -= Ilea 4r I:gprd 0llh review unit apyruv»I is required for r --r-- z �--- 8 EXIS BYCE.E519�OA431itmns/renmauons/alterations to GENERAL NOTES: INSPECTION PORT !L_-�- 99 28 101.06 f'``�� TO BE F+tYMV�EI<1�i(f8EMY71l'HC7alructoreJJwellixg. C � 5 SEEN TE 71 - 7. ALL CHANGES THIS PLAN MUST BE APPROVED BY THE LOCAL LT � � K.�r7 BOARD OF HEALTH AND THE DESIGN ENGINEER. ro Yarmouth Hcalth Dcpartmenl S AB v 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS 0. \ OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE BENCHMARK O BM APPROVED 10.8 101.43 LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: COR./SLAB L B EL.=101.83 99,32 99.08 "� CK � -310 CMR 15.405(1)(b): LOCAL UPGRADE APPROVED w -7ZII'1/1 1) A 2' varaince to the maximum depth requirement of 3', for RIN up to 5' of cover over the S.A.S. Units are H-20 & vented. 97.10 EX. EWER o� : INv.=7oo.3t AC 4_ M1me Date 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR 0 9511 95 98, z ���1// ®; ai TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE rn EXISTING,/ f °0 DESIGN ENGINEER. .- t " HOUSE(1150) / 101.0 u'7 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING NIH OF �s FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN DRAIN Z Wi, ENGINEER BEFORE CONSTRUCTION CONTINUES. 7.O.f.=102.71 25� Inz 99 95 24 Cellar Fl -g6 J± �O GN 5. ALL ELEVATIONS BASED ON AN ASSIGNED DATUM. 10(0 z JOHNL to 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF 95 25 0 CHURCHILLJR. ' ,,. 0' THE CONTRACTOR OR OWNER TONOTIFYTHE LOCAL BOARD OF 9,5,6 2- 9 .91 NO. 8068 HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. is �. "` •-. 101.4 -o 'P R 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. ae�ssF /ST 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. ^ 101.46 + ORIVEwar , AL 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS �. 815. AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE - 10079 LOT 64 (0/ DIRECTED BY THE APPROVING AUTHORITIES. 95 66o 91390± SF a LAM 10 7 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY '+THE °x OS LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNI G 9583 CONSTRUCTION. CIS i 9889 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SIILS 100,1y� IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND 94.00' :REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). S 31°48'20" E 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE x98 49 OF '�qS INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 98'9 f'Cy �SN� 13. SUBJECT SITE DOES LIE WITHIN A STATE REGULATED ZONE II. edge of 't G 14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND p vement g 98.47 PETER T: SURVEY OR FLOOD ELEVATION CERTIFICATION. 9548 97.19 NOT ASA PROPERTY LINE McENTEE 0- LINK I_ v CIVIL y 49-173 LANE' Na. 35109 MAP ID: BOB- PROPOSED SEPTIC SYSTEM UPGRADE PLAN 50 BOB -O -LINK LANE, WEST YARMOUTH MA JUL 1 52020 Prepared for: Brian Tracy, 50 Bob -O -Link Lane, West Yarmouth, MA 02673 HEALTH DEPT. OWNER OF RECORD Engineers: Surveyors: SCALE DRAWN JOB. NO. TRACY, BRIAN J Engineering Works, Inc. JC Engineering, Inc. 1"=20' P.T.M. 209-20 TRACY, BRENDA & BRIAN 12 West Crossfield Road 2854 Cranberry Hwy. FLOOD ZONE DESIGNATION 50 BOB -O -LINK LANE Forestdole, MA 02644 E.Worehom, MA 02538 DATE CHECKED SHEET N0. NON -HAZARD WEST YARMOUTH, MA 02673 1 (508) 477-5313 (508) 273-0377 7/3/20 P.T.M. 1 Of 2 SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & OUTLET AND SET TO 6" OF FINISH GRADE .O.F.=102.7± E.G. EEL.=101 8± /- F.G. EL.=101.4± L = 31' =ux- �' .«A. ® S=1% (MIN.) 4"SCH40 PVC TOP OF TANK=99.84 44" LIQUID LEVEL ADD GAS BAFFLE BOTT. OF TANK=95.30 PROPOSED 1500 GALLON SEPTIC TANI INFILTRATOR IM1530 GALLON PLASTIC TANK INV.=99.25 ICONNECT TO NEW SEWER AT HOUSE, INV.=100.3± PROPOSED D -80X INSTALL RISER & WATERTIGHT COVER SET TO 6" OF GRADE F.G. EL.=101.0± L = 5. L= _ %8(MN®"(MIN.) PVC IF]i4SCH40 PVC 11" TO INVERT INV.=98.67 J PROPOSED \- INV.=98.50 - INV.=99.00 D -BOX INV.=96.94 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION. 2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED STABLE BASE OR SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED, 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. BREAKOUT=TOP TOP ELEV.= 97.33 INV.= 96.94 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL.=97.33 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL INSPECTION PORT OVER ONEH ROW(MIN.) F.G. EL.=99.3 to 101.2 INSPECTION PORT 4 ROWS OF 5 UNITS AT 6.25'/UNIT = 31.3' SOIL ABSORPTION SYSTEM (PROFILE) ABUSH VEGETATIVE COVER KFILL WITH CLEAN NATIVE OR C SAND TO TOP OF CHAMBERS BOTTOM ELEV.= 96.00 �IIII�IIIII 5' MIN. SEPARATION 2,83' 6" 6" TO GROUNDWATER 4' (MIN.) OF NATURALLY EFFECTIVE WIDTH=12.8' OCCURRING PERVIOUS SOILS SUITABLE SOILS NO G.W., EL=88.6 USE 4 ROWS OF 5 -HIGH CAPACITY H-20 INFILTRATOR UNITS WITH 6" SEPARATION BETWEEN EACH ROW & NO STONE TYPICAL SECTION SEPTIC SYSTEM PROFILE N.T.S. DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO - NOT PERMITTED FOR GARBAGE GRINDER PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .74 GPD/SF DISTRIBUTION BOX: 1 INLET, 4 OUTLETS (H-20) USE 4 ROWS OF 5. HIGH CAPACITY INFILTRATOR H-20 UNITS WITH NO STONE. SPACED 6" BETWEEN STONE. SPACED 6" BETWEEN ROWSFOR A 12.8' x 31.3' BED x 31.3' BED SIDEWALL AREA: NOT APPLICABLE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF) (INFILTRATORS) 4 ROWS x 31.3 LF x 4.73 SF/LF = 592.2 SF DESIGN FLOW PROVIDED: 0.74 GPD/SF(592.2 SF) = 438.3 GPD NOMINAL BED AREA: 12.8' x 31.3' = 400.6 SF (400 SF SOIL LOG DATE: JUNE 30, 2020 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) WITNESS: MALLORY LANGLER RS HEALTH AGENT ELEV. TP DEPTH 100.1 A 0" LOAMY SAND 0YR 4/2 99.3 1p" B LOAMY SAND 10YR 5/6 97.1 36" C F -M SAND 2.5Y 6/6 88.6 138" NO GROUNDWATER ENCOUNTERED S.A.S. LAYOUT 00a 000 00 00 0000000 0000000 000000001 Surveyors: I- 28"--i DRAWN II00000000I h" 28"-f Closed End Plate Open End Plate T_ N l I I -if^-- 75" I F-34 1.25" Side View End View HIGH CAPACITY INFILTRATORS, H-20 LOADING INFILTRATOR CHAMBERS N.T.S. I PROPOSED SEPTIC SYSTEM UPGRADE PLAN 1 50 BOB -O -LINK LANE, WEST YARMOUTH, MA Prepared for: Brian Tracy, 50 Bob -O -Link Lane, West Yarmouth, MA 02673 Engineers: Surveyors: SCALE DRAWN JOB. NO. Engineering Works, Inc. KEngineering, Inc. N.T.S. P.T.M. 209-20 12 West Crossfield Road 2854 Cranberry Hwy. Forestdole, MA 02644 E.Woreham, MA 02538 DATE CHECKED SHEET N0. (508) 477-5313 (508) 273-0377 7/3/20 P.T.M. 2 Of 2