Loading...
HomeMy WebLinkAbout21-E097 415 Route 6A ApprovalTOWN OF YARMOUTH t ., _ ,x 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451 Telephone (508) 398-2231 Ext. 1292 -Fax (508) 398-0836 OLD KING'S HIGHWAY HISTORIC DISTRICT COMMI APPLICATION FOR CERTIFICATE OF EXEMPTION ECEIVED OCT 2 9 2021 YARMOUTH Application is hereby made for the issuance of a Certificate of Exemption under Sections 6 and 7 of Chapter 470 of Acts of 1973, as amended, for the proposed work as described below and on plans, drawings, or photographs accompanying this application. Tyne or print legibly: Address of proposed work: 415 Route 6A Map/Lot # 1231133 Owners): John E Grady and Lisa A Grady Phone #:8027607837 All applications must be submitted by owner or accompanied by letter from owner approving submittal of application. Mailing address: PO Box 822 Year built: 1810 +/- Email:'.qradyir@qmail.com Preferred notification method: Phone yeS Email Agent/Contractor: Self Mailing Address: Email Phone #: Preferred notification method: Ll Phone VJ Email Description of Pro osed Work Additional pages may be attached if necessary): Install Kohler Generator adjacent to the west side of the house behind the existing privacy fence. Signed (Owner or agent): APPROVED NOV 0 1 2021 YARMOUTH Date:Oct 26 2021 ➢ Owner/contractor/agent is aware that a permit may be required from the Building Department. (Check other departments, also.) ➢ This certificate is good for one year from approval date or upon date of expiration of Building Permit, whichever date shall be later. For Committee use only: Date: t ("12 )L Amount LM, 00 Cash/CK #: Rcvd by: b, ' Approved Reason for denial: Approved with changes Denied ' 1 I Date Signed: f Signed: APPLICATION #:LZ V5.2017 °F TOWN OF YARMOUTH RECEIVED a' 1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451 ` x Telephone (508) 398-2231 Ext. 1292 Fax (508) 398-0836 OCT 2 9 2021 OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEIF YARMOUTH' WAIVER OF 45 -DAY DETERMINATION The applicant/applicant's agent understands and agrees that due to the current declared National and State public health emergencies the determination of our Application for a Certificate of Appropriateness/Demolition/Exemption may not be made within 45 days of the filing of such application. The applicant agrees to extend the time frame within which a determination is to be made as required by the Old King's Highway Regional Historic District Act. SECTION 9 -Meetings, Hearings, Time for Making Determinations "As soon as convenient after such public hearing; but in any event within forty five (45) days after the filing of application, or within such further time as the applicant shall allow in writing, the Committee shall make a determination on the application. - Applicant understands that the review of this application will be scheduled as soon as the situation allows. Applicant/Agent Name {please Applicant/Agent signature: 3/2020 olin E Grady and Lisa A G rc te:Oct 26 APPROVE® NOV 0 1 2021 YARMOUTH Application #: _ �L I , t✓ A '7 7- , It V. « r� ,�prp � ��� _ T � � � � l '��, A ,�. � . --� --- j _� � t � �� ,��,vt� '� - ` � � �. i � _ � --. _ r ... /' _- � � � / _ li/ _ � .l. l �. KO H L E R. 7s, =-,, ,ri n-- .. `Mollis: 20RCA(L) 292021 09001 4 WHLER. NATIONALLY REGISTERED The Kohler' Advantage • High Quality Power Kohler home generators provide advanced voltage and frequency regulation along with ultra-low levels of harmonic distortion for excellent generator power quality to protect your valuable electronics. • Extraordinary Reliability Kohler is known for extraordinary reliability and performance and backs that up with a premium 5 -year or 2000 hour limited warranty. • Powerful Performance Exclusive Powerboost- technology provides excellent starting power. § • Aluminum Enclosure o Attractive aluminum enclosure allows installation as close as 18 inches from your home or small business. ; Enclosure panels can be removed without tools to allow easy access for maintenance and service. Generator Ratings Multi -Fuel LPG/Natural Gas Standgrd tum& 1 • RDC2 Controller o One digital controller manages both the generator set and transfer switch functions (with optional Model RXT). o Electronic speed control responds quickly to varying demand. o OnCueO Plus Generator Management System for remote monitoring is included with the generator. • Kohler Command PRO Engine Features o Kohler Command PRO® OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. • Designed for Easy Installation o Sturdy aluminum base can be mounted on gravel or a concrete mounting pad. o Fuel and electrical connections through the enclosure wall eliminate the need for stub -ups through the base. o Customer connection terminal block located near the controller allows easy access for field wiring. o Designed for outdoor installation only. Certifications o Meets emission regulations for U.S. Environmental Protection Agency (EPA) with both natural gas and LPG. o UL 2200/cUL listed (60 Hz model). o CSA certification available (60 Hz model). o Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters. o Meets 181 mph wind rating. • Approved for stationary standby applications in locations served by a reliable utility source. • 20RCAL models packaged with a Model RXT automatic transfer switch are available. See page 4 and the Model RXT ATS specification sheet. • Warranty o 5-year/2000 hour limited warranty for on -grid (standby) applications in locations served by a reliable utility source, Standby Ratings Line Circuit Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS: Standby ratings applyto installations served by areliable utility source. 4 single-phase unitsare rated at 1.0 powerfactor. The standby rating is applicable to variable loads with an average load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO- 304611, BS5514, AS2789, and DIN 6271. GENERAL GU IDERINES FOR DERATING: ALTITUDE: Derate 4% per 305 m (1000 ft.) elevation above 153 m (5048). TEMPERATURE: Derate2%per 5.5"C (14"F) temperature increase above 16°C (60°F). Availability issubjecttochange without notice. The generator setmanutacturerreserves therighttochange the design orspecificationswhhoul notice and without any obligation orliabilitywhatsoever. Contact your local Kohler Co. generator distributor for availability. R1' -EO T § Check the appliance manufacturer's specifications for actual power requirements- Consult a Kohler® Power Systems professional to calculate your exact residential power system requirements. Meets NFPA guidelines for 18 inch clearance to combustible materials. Check state and local codes for minimum distance required from a structure. 134-272 (20RCA) 5121d Natural Gas LPG Breaker Alternator Voltage Phase Hz kW/kVA Amps kW/kVA Amps Amps Pales 2F7 120/240 1 60 18/18 75 20/20 83 100 2 1201208 3 60 17/21 58 17/21 58 70 3 2G7 120/240 3 60 17/21 51 17/21 51 60 3 2771480 3 60 17/21 26 17/21 26 30 3 Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS: Standby ratings applyto installations served by areliable utility source. 4 single-phase unitsare rated at 1.0 powerfactor. The standby rating is applicable to variable loads with an average load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO- 304611, BS5514, AS2789, and DIN 6271. GENERAL GU IDERINES FOR DERATING: ALTITUDE: Derate 4% per 305 m (1000 ft.) elevation above 153 m (5048). TEMPERATURE: Derate2%per 5.5"C (14"F) temperature increase above 16°C (60°F). Availability issubjecttochange without notice. The generator setmanutacturerreserves therighttochange the design orspecificationswhhoul notice and without any obligation orliabilitywhatsoever. Contact your local Kohler Co. generator distributor for availability. R1' -EO T § Check the appliance manufacturer's specifications for actual power requirements- Consult a Kohler® Power Systems professional to calculate your exact residential power system requirements. Meets NFPA guidelines for 18 inch clearance to combustible materials. Check state and local codes for minimum distance required from a structure. 134-272 (20RCA) 5121d