Loading...
HomeMy WebLinkAboutEngineer Plans - 2001OF FNDN EL71.5f �- ACCESS COVER WITHIN 6" TO FIN, GRADE ACCESS COVER (WATERTIGHT) EL69t WITHIN 6" TO FIN. GRADE MINIMUM .75' OF COVER OVER PRECAST PROPOSED 1,500 RUN PIPE LEVEL GALLON SEPTIC rr FOR FIRST 2' L.65 9,5 TANK (H- 10 ) �H-10 GAS BAFFLE E1.85.75 5.58 0 o FLOW LINE 1 \ 6_' CRUSHED STONE OR MECHANICAL EL65.5 2% 2" DOUBLE WASHED PEASTONE DEPTH OF FLOW = 4' COMPACTION, (15.221 (21) 3.5 O SIDES 10 3' O ENDS REQUIRED TEE SIZES: INLET DEPTH = 10" MIN. BELOW FLOW LINE OUTLET DEPTH = 14" MIN, BELOW THE FLOW LINE H-20 14 o (--2-7 MIN. SLOPE) (--1-7. MIN.. SLOPE)( --1 00 0 .7• MIN. SLOPE) 3/4" TO 1 1/2" DOUBLE WASHED STONE FOUNDATION 22' SEPTIC TANK 10' D' BOX 4' LEACHING FACILITY SEPTIC DESIGN (GARBAGE DISPOSER IS NOT ALLOWED) NUMBER OF BEDROOMS: 3 DESIGN FLOW: 3 BR x 110 G/D/BR = 330 G/D USE A 330 G/P REQUIRED DESIGN FLOW SEPTIC TANK 330 G/D (2) = 660 G/D USE PROPOSED 1,500 GALLON SEPTIC TANK LEACHING SIDE AREA: 2 x 2' x (9.83'+31') = 163.3 SF BOTTOM AREA: 9.83' x 31' = 304.7 SF SIDES: 163.3 SF + BOTTOM: 304.7 SF TOTAL: 468 SF PROPOSED CAPACITY: 468 SF x 0.74 G/D/SF = 346.3 G/D O.K. USE: (6) H-20 HIGH CAPACITY INFILTRATORS WITH 3.5' STONE AT SIDES, 3' AT ENDS, AND 14" BELOW. fipg�.. y�®1�® �+ USEM DrkSIG DATA 3' MAX. 3.5' O SIDES 3' O ENDS 18' 14" 4.9' 6.9' f30TT0 0 TH2 EI -58.6 .SEE SOIL LOGS BOTTOM OF THt EL56.6 SEE SOIL LOGS JANE A. RYER / 'EL. ENCHMARK: I/ / ONCRETE BOUND DOUGLAS A. ROBERTSON I Y / 71.33 I 11 I CERT# LCP 39085B "0 ro ro ro o o rn W 03 CB DH FND ISPL.) �\ 365.61 \ \ \ \ 74 �' 4/Z7// i 1 \ 73 -72- - - - - it 1� 70.6A \ ` \ 71 PROPOSED X 71.0- / �1 1l LOT 1 r/ DRIVEWAY �� i/ / 0 v v ) / / 42,330 s. f. / v 71.5_ X 70.6 o Ix I Q v A 0.97 ac. / / / / i v ` 0 / / / > \ r O PROPOSED 3 10� O ` o BEDROOM DWELLING rn / /O^ 11 / 1 LOT 3 I I l i i I I ri I I I i i 738// / ri l I� ry/ \ TOP OF FNDN=EL. 72.00 Np, §� 30' CIO) M U �/ I/ ✓1 ' p u �O QD DO 71 U _ q m 41 7 _ -65. Y T DENNIS R.R. POND f v o� SJ�S�R I LOCUS 0 MID CAPE EXIT i 7 / HIGHWAY RT.6 SCALE 1" 2000' ASSESSORS MAP 94, PARCEL 1, LOT 1 FLOODZONE: C - *ZONING DISTRICT: R-40 MINIMUM YARD SETBACKS: FRONT - 30 ft. SIDE/REAR - 20 ft. *TO BE CONFIRMED BY BUILDING COMMISSIONER DEPTH (in.) WATER SHUT OFF VALVE TO BE LOCATED W"' EDLAPROPOSOCLON �o GAS SHUT OFF VALVE YR 4 2 TO BE LOCATED g" EXISTING GAS LINE (24 GAL. < 15 MIN.) TO BE LOCATED y� EXISTING PHONE LINE TO BE LOCATED BOTTOM PERC: AT 66" EL.62.1 EXISTING ELECTRIC LINE 2.5 Y 5 6 TO BE LOCATED 36" EXISTING CABLE T.V. LINE NO WATER OBSERVED 64.6 TO BE LOCATED -70- EXISTING CONTOUR 4- 70.6 EXISTING SPOT GRADE -PROPOSED CONTOUR x PROPOSED SPOT GRADE TH1 SOIL TEST HOLE SEE TEST HOLE LOG(S) Y T DENNIS R.R. POND f v o� SJ�S�R I LOCUS 0 MID CAPE EXIT i 7 / HIGHWAY RT.6 SCALE 1" 2000' ASSESSORS MAP 94, PARCEL 1, LOT 1 FLOODZONE: C - *ZONING DISTRICT: R-40 MINIMUM YARD SETBACKS: FRONT - 30 ft. SIDE/REAR - 20 ft. *TO BE CONFIRMED BY BUILDING COMMISSIONER DEPTH (in.) TH1 ELEVATION 0" 67 6 SOIL CLASS: 1 (SANDS, LOAMY SANDS) A SAND ALOAM PERC RATE: < 2 MPI (5 MPI DESIGN) YR 4 2 . PRESOAK: 0:00:00-0:09:45 g" N UTA (24 GAL. < 15 MIN.) 66.9 9": 0:09:45 LOAMY SA D BOTTOM PERC: AT 66" EL.62.1 2.5 Y 5 6 36" ITA NO WATER OBSERVED 64.6 GSANDDATE: FINE 1/10/00 -0 '' 6%4 rrMANE'Erc wiwnAGL a FARIA SE 132"'----56.6 (DOWN CAPE ENGINEERING) TEST HOLE LOGS WITNESS AMY VON HONE, RS EXCAVATOR: OWNER'S EXCAVATOR NOT TO SCALE DEPTH (in.) TH2 ELEVATION 0" A 70'8. SOIL CLASS: I (SANDS, LOAMY SANDS) So DOR LOAM PERC RATE: < 2 MPI (5 MPI DESIGN) 6" IT 899 (ASSIGNED 0 Cl) \ 6 /�----64---� i /ice o =HEALTHDEPT. 65 64 I I0pn I ? / 194.06 \ s I 1 LOT 2- 0 48-11 UNS �TA1 1166.151 NO WATER OBSERVED .5 Y 11. THE LOCATION OF EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN IS APPROXIMATE. PRIOR TO ANY EXCAVATION ON THIS SITE, THE EXCAVATING CONTRACTOR SHALL MAKE THE REQUIRED 72 HOUR NOTIFICATION TO DIG SAFE (1-888-344-7233) AND ANY OTHER UTILITIES WHICH MAY HAVE CABLE, PIPE OR EQUIPMENT IN THE CONSTRUCTION AREA FOR VERIFICATION OF LOCATIONS. 2. ALL SEPTIC WORK AND MATERIALS TO CONFORM TO 310 CMR 15.00 TITLE 5 AND YARMOUTH HEALTH REGULATIONS, 3, VERTICAL DATUM ASSUMED FROM QUAD. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHTO-H10. 5. THIS PLAN IS FOR A PROPOSED SEWAGE DISPOSAL SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 6. ALL SEPTIC PIPING SCH-40-4" FVC UNLESS NOTED. 7. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 8. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 9. PIPE JOINTS TO BE MADE WATERTIGHT. 10. WATER TEST D -BOX FOR LEVELNESS. SCALE: 330' off. 508-362-4541 fax 508-362-9880 down cape engineering, Inc. Of 0CIVIL ENGINEERS �P ClK Of MA, ARNE H. 4yN Ar�t,P ARNEx I�xy, OJAL APPROVED DATE BOARD OF HEALTH A LAND SURVEYORS � civ y )9-403 z-/�-p/ �� �{/� 0 A9�rE Q rs s34a or 939 main St. yarmouth, ma 02675 -'�r�d���/ MA DATE � N��� n.IAI ��o ...:..a c TITLE 5 SITE PLAN OF LAND IN YARMOUTHPORT, MA PREPARED FOR SID SIDDHARDTH LOCATED AT LOT 1 OLD HYANNIS ROAD YARMOLITHPORT, MA 02675 SCALE: 1 "=30' DATE: 9-25-00 REVISED: 2-9-01 30 0 30 60 90 Ft.