Loading...
HomeMy WebLinkAboutRevised Engineer Plan - 11/2021PRC AE 5 -s EXISTING LEACH PITS TO BE PUMPED & FILLED LEGENDS 7WATE �uvEs' OR REMOVED. REMOVE ALL ASSOCIATED SEPTIC COMPONENTS CONTAMINATED SOILS & -REPLACE WITH LINE -yT�- CLEAN MEDIUM SAND' PER TITLE 51:. EXISTING GATE C1 1000 O 0 F SEPTIC TANK INF THIS IS A YHim VIV tS-1/Y x 14 In PAPER FOR PROPER SCALE ROBB SYKES No. 35418 REVISED NOVEMBER 5. 2021 THI5 PLAN IS INTENDED SOLELY FOR INSTALLATION OF THE SEPTIC SYSTEM DEPICTED ON IT. FOR ANY OTHER CHANGES TO THE PROPERTY INCLUDING PLACEMENT OF ADDITIONS, SHEDS. FENCES OR SWIMMING POOLS. OWNER SHOULD CONSULT WITH A MASSACHUSETTS REGISTERED LAND SURVEYOR. SEWAGE DISPOSAL SYSTEM PLAN TO SERVE EXISTING DWELLING JAMES TSOUKALOS NNERrSI OF RECORD 52-54 IVANHOE AVENUE YARMOUTH, MA 155Geo Ryder Rd S PROPERTY ADDRESS Chothom, MA 02633 ,,,,., IDATE. OCTOBER 13.:2021 SOIL EVALUATOR: .DAVID D. COUGHANOWR. ASE #461 WITNESSED BY: PHIL RENAUD. HEALTH DEPT. 1 NO GROUNDWATER ENCOUNTERED TEST PIT PERC AT 50 In — 2 MIN/INCH IN C SOIL5 ELEVATIC 50.25 48.25 An nn N DEPTH SOIL USDA SOIL SOIL COLOR SOIL Of HE INCHES HOR20N TEXTURE (MUNSELL) MOTTLES PLACE END CAPS ON LINES 0-8 Ap SANDY LOAM 10 YR 313 NONE FRIABLE 8-24 Bw LOAMY SAND 10 YR 516 NONE LOOSE 24-123 { MEDIUM SAND 10 YR 613 NONE LOOSE 1000 GALLON SEP -HC -rANK EXISTING UNIT - DIMENSIONS & DETAIL TANK TO BE PUMPED DRY AT TIME OF INSTALLATION AND EXAMINED FOR STRUCTURAL INTEGRITY. INSTALL NEW PVC OUTLET TEE EQUIPPED WITH A GAS BAFFLE. REPLACE WITH A NEW I in 1500 GALLON TANK TAPER IF CRACKED, ROTTED OR OTHERWISE COMPROMISED. ti w NOT TO . � SCALE B ft --g_-_---------- C in INLET OUTLET COVER COVER .xc�,f7jF7 EFROM BUILDI14TO 1, D -BOX LE b. in STONE BASE IF NEW SEPARATION BETWEEN INLET & OUTLET TEES NO LESS THAN LIQUID DEPTH CROSS SECTION VIEW DOSTR#SV II §OIIV 130W ANDDIMENSIONS USE SHOREY DB -6 H-20 NOT TO )b in SCALE JOIN --I —f FROM =. c TANK y c TO 01 O SAS y AT .005 ftJft PLACE END CAPS ON LINES 6 to STONE BASE 24;� CROSS SECTION VIEW DESIGN CALCULATIC, DESIGN FLOW: 4 BEDROOMS X 110 GPD = 440 GPD SEPTIC TANK, 440 GPD X 2 DAYS = 880 GALLONS USE EXISTING 1000 GALLON SEPTIC TANK IF IN SOUND STRUCTURAL CONDITION AND INSTALL A SECOND NEW 1000 GALLON SEPTIC TANK IN SERIES. OTHERWISE REMOVE EXISTING SEPTIC TANK AND INSTALL A NEW 1500 GALLON TWO COMPARTMENT SEPTIC TANK. DISTRIBUTION BOX: INSTALL UNIT DEPICTED BELOW. THE LONG TERM ACCEPTANCE RATE FOR A CLASS ONE SOIL WITH A PERCOLATION RATE BELOW 5 MINUTES PER INCH = 0.74 GALLONS PER DAY PER SQUARE FOOT THE 38 ft x 16 LEACHING FIELD DEPICTED CAN LEACH: BOTTOM AREA = (38 x 16) = 608 sq. ft. SIDEWALL AREA =0 0 so ft. TOTAL AREA = 608 sq. tt. FLOW CAPACITY = C.74 x 608 = 449.9 gal/day .INSTALL A 38 ft x 16 ft x LEACH FIELD AS CONFIGURED BELOW. FLOW CAPACITY = 449.9 gallday WHICH EXCEEDS THE 440 gollday REQUIRED FOR A FOUR BEDROOM DESIGN. LEACHING STONE TO BE DOUBLE WASHED 8 ❑ D -BOX 3' y SE H-20 MAX CAP PIPE ENDS ���"�^Ma'��,,.� 46.31 b in 46.53 'TONEI LEACHING FIELD + BASE 46.50 � -REFER TO DETAIL BOX 3-7 ft O 45.81 "' BELOW NO GROUNDWATER FREE OF IRONS, FINES &DUST. FIELD DIMENSIONS VIAIL PIPE ENDS AND VENT. JOIN PIPE TO BE SCH. 40 PVC INSPECTION PORT WITHIN 3 in OF FINAL GRADE. PERF PIPE AND TO SLOPE i AT .005 ftJft PLACE END CAPS ON LINES WITHOUT VENT. p N ' P 38.0 ft N 40.00 MOTTLING OBSERVED DISCHARGE HOLES NOT SMALLER THAN 318 in. NOT GREATER THAN 5/8 In. ❑ D -BOX 3' y SE H-20 MAX CAP PIPE ENDS ���"�^Ma'��,,.� 46.31 b in 46.53 'TONEI LEACHING FIELD + BASE 46.50 � -REFER TO DETAIL BOX 3-7 ft O 45.81 "' BELOW NO GROUNDWATER IP 0 i N z ro s tP p 38.0 ft -INSTALLER TO OBTAIN DISPOSAL WORKS PERMIT BEFORE STARTING WORK. -ALL COMPONENTS INSTALLED SHALL MEET THE MINIMUM REQUIREMENTS OF MASSACHUSETTS TITLE 5 SEPTIC CODE (310 CMR 15). -INSTALLER TO VERIFY LOCATIONS OF ALL UNDERGROUND UTILITIES BEFORE EXCAVATING FOR SYSTEM. -ECO-TECH RAPID RESPONSE RECOMMENDS THE INSTALLATION OF LOW FLOW FIXTURES & APPLIANCES. AND PERIODIC PUMPING OF THE SEPTIC TANK. -SYSTEM IS NOT DESIGNED TO WITHSTAND VEHICULAR LOADING. DO NOT PARK OR DRIVE VEHICLES OVER SEPTIC SYSTEM. DINING KIT- KIT- DINING ROOM CHEN CHEN ROOM LIVING LIVING ROOM ROOM LOWER UNFINISHED BED BATH BATH BED BOOM ROOM BED BED ROOM ROOM UPFER BASEMENT IF L o W p R 0 F o �I ALL PIPE TO BE 4 in SCH. 40 PVC TOP OF FOUNDATION RAISE COVERS TO WITHIN AND TO PITCH AT 1/8 In/ft MIN EL = XX +— //�\6 in OF FINAL GRADE I y yy �� / W W V � L y J 49.75 EXISTING 1000 GALLON L TO DETAIL TO DETAIL 10 /t 14 ft II SEWAGE DISPOSAL SYSTEM PLAN 1152-54 IVANHOE AVENUE YARMOUTH. MA IIOCTOBER 13. 2� ET( E-460�L P 40.00 MOTTLING OBSERVED II SEWAGE DISPOSAL SYSTEM PLAN 1152-54 IVANHOE AVENUE YARMOUTH. MA IIOCTOBER 13. 2� ET( E-460�L P