LEGEND
-- 99-
EXISTING CONTOUR
X 99.1
EXIST. SPOT ELEV.
-[99}-^-
PROPOSED CONTOUR
[98.4]
PROPOSED. SPOT EL.
TTH11
0"
+�}
TEST HOLE
2�
SLOPE OF GROUND
0r
UTILITY POLE
FIRE HYDRANT
Ni NOT ALL SYMBOLS MAY APPEAR IN. DRAWING
Yarmouth Conservation Conditions:
1. A hard copy of the plan shall be provided to the Conservation
Administrator for review. An electronic copyof the final plan shall
be provided to kgrant@yarmouth:ma.us.
2. The proposed sewage disposal system shall meet the applicable
Title 5 wetlands setbacks as set forth by the Health Department.
3. A'work limit' line shall be established with Erosion Controls (i.e _
straw bales, staked filter fabric, bark mulch, 'silt sacks,' products
made with rice straw, and other weed -free products or approved by
the. Commission.) Hay bales are not allowed. It is the applicant's
responsibility to implement and maintainappropriateand adequate
erosion controls measures throughout the construction process.
4. No work of any kind shall occur on the. Resource Area side of the
work .limit line. This line shall be established prior to any
construction or work.
5. All imported fill shall be clean and not contain any foreign debris
such as cement, bituminous concrete, rubber, metal, trash,
boulders, etc.
6. Debris, including litter, shall be picked up immediately. Any excess
material that is excavated fromthejob site shall be disposed of at
a location approved by the Conservation Administrator or in a
covered dumpster, No debris shall be allowed in a Wetland or
Waterway.
7. Washing of equipment/tools shall be done OFF-SITE or handled in
a manner approved by the Conservation Administrator.
8. No equipment shall be refueled, nor shall fuel be stored within 100
feet of a resource area.
9. The cesspool is to be pumped dry, the connection broken, and
- filled with clean sand.
10. Any area that is disturbed during. construction shall be revegetated
immediately or as soon after as the growing season commences.
Permanent stabilization shall be carded out in order to minimize erosion.
TEST HOLE LOGS
ENGINEER: DAVE MASON
WITNESS: MALLORY LANGLER
DATE:
2/24/21
PERC.
RATE _ _:�_ 2 MIN INCH
CLASS
- SOILS
4 ELEV.
1
0"
6_5
-A
F-111
0r
LS
sf
1 CYR 3/1
45"
LOCUS IS WITHIN FEMA FLOOD ZONE
SYSTEM DESIGN:
GARBAGE DISPOSER IS NOT ALLOWED
DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD
USE A 330 GPD DESIGN FLOW
TIGHT TANK: 330 GPD (5) = 1650
MIN. 2000 GAL TIGHT TANK CAPACITY REQUIRED
USE A H-20 3000 GAL TIGHT TANK
APPROVED I DATE
NOTE: CONTRACTOR TO PROVIDE CONSERVATION
AGENT WITH A DE -WATERING PLAN (UTILIZING SILT
CONTAINMENT BAGS) PRIOR TO THE START OF
CONSTRUCTION.
C
MS
GROUNDWATER ADJ. DATA:
PERC WELL: MW 29
ICYR 7/4 ZONE: B
ADJUSTMENT: 2.8' (FEB. '21)
120" I -3.5'
G.W. ENCOUNTERED AT EL. 4.5'
DEC
DCE #21-208
MA
BOARD OF HEALTH
TEST HOLE LOGS
ENGINEER: RON CADILLAC
WITNESS: BRUCE
MURPHY
DATE: 7/6/05
Raufe
PERC. RATE _
< 2 MIN/INCH
CLASS I
SOILS
ELEV.
F-111
0r
8.0'
FILL
62"
E
LS
76" 5Y 3/1 1.67'
P EAT
102"1 11-0.5'
C
PERC
LS
5YR 4/5
150" 1 -4.5'
G.W. ENCOUNTERED AT EL. 3.42'
BUOYANCY CALCS:
H-20 3000 GAL. ST WEIGHS 37,000 LBS
6.0' x 17.0 x 7.0 X 52.4 = 44,554 LBS UPLIFT
ADDITIONAL POURED CONCRETE BALLAST IS REQUIRED
(44,554 LBS 37,000 LBS=7554 LBS 0150LBS/CF =
50.4 CF REQUIRED)
ADD 51 CF CONCRETE BALLAST
SYSTEM PROFILE
(NOT TO SCALE)
ADD A MINIMUM OF 51 CF
POURED CONCRETE FOR
BALLAST OVER THE TOP
EXISTING TOF EL 8.T AND SIDES; MAINTAIN ALL
ACCESS COVERS
MINIMUM .75' OF
COVER OVER PRECAST -
INV. IN 6.3
3000 GAL.. H-20 S/T
3/5 TOTAL CAPACITY
ALARM ON
31"
EL. 1.3'
NOTES
NORMAL HIGH WATER LEVEL ALARM 1: DATUM IS NAVD 88
(AUDIBLE AND VISUAL) TO BE SET FOR 2. MUNICIPAL WATER IS EXISTING
3/5 OF SYSTEM. CAPACITY, ALARM AND
PRESS TO SILENCE SWITCH ON PANEL
INSIDE BUILDING.LOW VOLTAGE FLOATS, 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT.
.
SIMPLEX PANELS, MEYERS OR EQUAL. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST
PROP. 24" 0 CAST UNITS TO BE AASHO H-ZQ
IRON WATERTIGHT 5. PIPE JOINTS TO BE MADE WATERTIGHT.
COVER TO GRADE
6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE
WITH 310 CMR 15.000 (TITLE 5.)
7.55' 7. THTO FOR
RTE
BE USED LINED
WORK ONLY AND
NOSTAKING OR ANY
7.3' ADJUSTED OTHER PURPOSE.
GROUNDWATER
8, PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC:
9. COMPONENTS NOT TO BE BACKFILLED OR
CONCEALED WITHOUT INSPECTION BY BOARD OF
HEALTH AND PERMISSION OBTAINED FROM BOARD
OF HEALTH.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR
*NOTE: INTERIOR PLUMBING TO BE RAISEDANDRE-ROUTED _ TIGHT TANK
TO EXIT THE DWELLING IN LOCATION SHOWN ON PLAN VIEW:
PLUMBER TO CONFIRM FEASIBILITY PRIOR TO INSTALLING ANY 2 (NOT TO SCALP)
PORTION OF THE SEPTIC SYSTEM (_% SLOPE)MIN.
WATERPROOF/WATERTIGHT
FOUNDATION 10' TIGHT TANK
CALLING DIGSAFE (1-888-344-7233) AND
6" CRUSHED STONE OR MECHANICAL VERIFYING THE LOCATION OF ALL UNDERGROUND &
OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF
Raufe
COMPACTION. (75.227 [2]) WORK.
F�
c o°'
I
11. EXISTING LEACHING FACILITY SHALL BE PUMPED
AND REMOVED OR PUMPED AND FILLED WITH CLEAN
ASSESSORS MAP 22 PARCEL 180
sf
12. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM
LOCUS IS WITHIN FEMA FLOOD ZONE
IS SUITABLE FOR ALARM CONNECTION. ELECTRICAL
AE (EL. 11) AS SHOWN ON
�� Dy
C C9Gtn e
aces
Locu
P
�;
TIGHT TANK. PROVIDE SILT CONTAINMENT AS
e
NECESSARY.
C
Lewis
O Ol
Bay
TIGHT TANK NOTE S:
/"� t7
TANK SYSTEM SHALL BE ABANDONED/REMOVED.
A'odia
AN OPERATIONS AND MAINTENANCE PLAN WILL
CALLING DIGSAFE (1-888-344-7233) AND
6" CRUSHED STONE OR MECHANICAL VERIFYING THE LOCATION OF ALL UNDERGROUND &
OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF
LOCUS MAP
COMPACTION. (75.227 [2]) WORK.
SCALE 1"=2000'±
11. EXISTING LEACHING FACILITY SHALL BE PUMPED
AND REMOVED OR PUMPED AND FILLED WITH CLEAN
ASSESSORS MAP 22 PARCEL 180
SAND.
12. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM
LOCUS IS WITHIN FEMA FLOOD ZONE
IS SUITABLE FOR ALARM CONNECTION. ELECTRICAL
AE (EL. 11) AS SHOWN ON
PERMIT REQUIRED.
COMMUNITY PANEL#25001C0588J
13. DEWATERING REQUIRED FOR INSTALLATION OF
DATED 7/16/2014
TIGHT TANK. PROVIDE SILT CONTAINMENT AS
NECESSARY.
14. WHEN SEWER SYSTEM BECOMES AVAILABLE, THE
OWNER SHALL CONNECT A SEWER AND TIGHT
TIGHT TANK NOTE S:
/"� t7
TANK SYSTEM SHALL BE ABANDONED/REMOVED.
AN OPERATIONS AND MAINTENANCE PLAN WILL
BE REQUIRED FOR THE LIFE OF THE SYSTEM.
ALARM TO ACTIVATE AT 3/5 HOLDING
CAPACITY. TANKS TO BE PUMPED AS
REQUIRED AND ALARM TO BE INSPECTED 1
TIME PER YEAR.
TIGHT TANK SHALL BE DESIGNED AND
INSTALLED IN ACCORDANCE WITH 310 CMR
15.260, AS AMENDED.
SUNROOM
DIN/NG KITCHEN BATH
BEDROOM ROOM
LIVING
BEDROOM ROOM BEDROOM
OF
T�
/<�JANIELq �.
CIVIL �'
46502
EXIST -ING
FLOOR PLAN
I, o/F-L_,tr` -7.
VARIANCES REQUESTED:
UNDER MAX. FEASIBLE COMPLIANCE 15.405:
(1j) REDUCTION OF THE REQUIREMENT OF A 12 INCH
SEPARATION BETWEEN THE INLET AND OUTLET TEES
AND HIGH GROUNDWATER. (12" to 0")
(PROVIDE WATERTIGHT BOOTS)
Permitvalid for REPAIR Or SEPTIC SYSTEM
ONLY, due to State and Local septic variances.
Board of Health re, lew and approval is required for
any future additionstrenoval iunsla Iterations. to
sewage facilities and/or structuresfdsveiling:
Yarmouth health Department
APPROVED
6TZ:3110< 44-3 N /o ?®z/
Name Date
TITLE 5 SITE PLAN
OF
31 BAYBERRY RD.
WEST YARMOUTH, MA
PREPARED FOR
77177-]YANA VILENCHIK
UL,I LH LUL!
DATE: SEPTEMBER 7, 2021
HEALTH Deft EV: OCTOBER 12, 2021 (DE -WATERING NOTE)
Scale:1 "= 20'
A 0 10 20 30 40 50 FEET
I off 508-362-4541
fax 508-362-9880
downcape.com
down cape engineeting, iac.
civil engineers
_ land surveyors
939 Moin Street ( Rte 6A)
DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 0257.5
21-208 VILENCHIK.DWG