Loading...
HomeMy WebLinkAboutAir Leakage Report - 51 Park Ave YarmouthAir Leakage Property Brad and Jessica Zelch 51 Park Ave West Yarmouth, MA 02673 Weather:Barnstable AP, MA 51 Park Ave W. Yarmouth 6397177.154.1ParkAveWYarmouth 16.0.6..MEB.blg Organization Cape Cod HERS Raters (508)737-8011 Chris Picariello Builder Mullen Building & Remodeling Whole House Infiltration ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. The 62.2-2013 rate incorporates any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v16.0.6 This information does not constitute any warranty of energy costs or savings. © 1985-2021 NORESCO, Boulder, Colorado. HERS Confirmed 2021-11-15 Rating No:154 Rater ID:6397177 Duct Leakage Ventilation Blower Door Test Heating Cooling Natural ACH 0.16 0.14 ACH @ 50 Pascals 2.21 2.21 CFM @ 25 Pascals 658 658 CFM @ 50 Pascals 1032 1032 Eff. Leakage Area (sq.in)56.7 56.7 Specific Leakage Area 0.00015 0.00015 ELA/100 sf shell (sq.in)0.83 0.83 CFM50/sf shell 0.15 0.15 Leakage to Outside Units duct 1 CFM @ 25 Pascals 2 CFM25 / CFMfan 0.0011 CFM25 / CFA 0.0008 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 3 Eff. Leakage Area (sq.in)0.17 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0260 Mechanical Balanced ASHRAE ASHRAE Adj. Sensible Recovery Eff. (%)67.0 62.2-2010 62.2-2013 Adj. Total Recovery Eff. (%)48.0 Rate (cfm)89 64 69 Hours/Day 18.6 24.0 24.0 Fan Watts 38.0 Cooling Ventilation Natural Ventilation