HomeMy WebLinkAboutFoundation Plan-R112'-3"±
ti
N
- 30'-4" -
- 28'-0"± -
3'-6" DOOR
OPENING
/-err RV/�IIVI/'1 C Llfvll I
OF FLOWABLE FILL AT
LOWEST BOTTOM OF
FOOTING ELEVATION
A FOUNDATION PLAN
SCALE: 1/4" = V-0"
6-8"
9'-0"±
6-0"
- 6'-10" 6-10"
10" 0 SONOTUBE
ON 28" 0 BIGFOOT FOOTING (TYP.)
22'-10"
10'-6"
10" 0 SONOTUBE
ON THE STRIP FOOTING
GENERAL NOTES:
1. CODES:
MASSACHUSETTS STATE BUILDING CODE, NINTH EDITION (780 CMR)
2. DESIGN LOADS:
DEAD LIVE
10 psf 40 psf FIRST FLOOR
10 psf 30 psf BEDROOMS
10 psf 40 psf EXTERIOR DECKS
10 psf 20 psf ATTIC
10 psf 30 psf ROOF (GROUND SNOW)
3. DO NOT SCALE FROM PLANS. IF DIMENSION IS NOT GIVEN, REFERENCE ARCHITECTURAL FLOOR PLANS PRIOR TO
CONTACTING ENGINEER.
4. CONTRACTOR TO VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO CONSTRUCTION AND SHALL NOTIFY
THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES BETWEEN DOCUMENTS AND FIELD CONDITIONS.
5. THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS DURING CONSTRUCTION. THE ENGINEER IS
SPECIFYING THE FINISHED CONDITION ONLY, WITHOUT ASSUMING NEITHER KNOWLEDGE NOR RESPONSIBILITY
FOR HOW THE CONTRACTORS WILL ACHIEVE THIS RESULT.
6. DIMENSIONS FOR THE EXCAVATION PIT ARE BASED OFF THE RECOMMENDATIONS BY THE LICENCED SITE
PROFESSIONAL (LSP). THIS OFFICE DOES NOT DELINEATE THE EXTENT OF THE CONTAMINATION. THIS OFFICE IS
TO BE NOTIFIED IMMEDIATELY IF EXCAVATION BEYOND WHAT IS SHOWN ON THIS PLAN IS REQUIRED.
FOUNDATION NOTES:
1. THE STRUCTURE IS TO BEAR ON NATURAL UNDISTURBED SOILS CAPABLE OF SUPPORTING 1.5 TONS PER SQUARE
APPROXIMATE LIMIT FOOT, WITH A V LAYER OF CRUSHED STONE, OR FLOWABLE FILL. IF QUESTIONABLE BEARING IS ENCOUNTERED IT
OF FLOWABLE FILL AT IS TO BE REMOVED AND REPLACED WITH ADDITIONAL FLOWABLE FILL.
LOWEST BOTTOM OF
FOOTING ELEVATION 2. ALL EXTERIOR FOOTINGS TO HAVE A MINIMUM OF 4' OF FROST COVER.
3. 5/8" ANCHOR BOLTS ARE TO BE INSTALLED AT 4' ON CENTER AND HAVE A MINIMUM EMBEDMENT DEPTH OF 121,
UNLESS NOTED OTHERWISE. ADDITIONALLY ANCHOR BOLTS TO BE INSTALLED W/IN 121, OF ALL JOINTS AND
CORNERS.
4. ANCHOR BOLTS AND ALL REINFORCING IS TO BE POSITIONED AND SECURED IN PLACE PRIOR TO POURING
CONCRETE. NO WET STICKING IS ALLOWED.
5. WHERE ANCHOR RODS ARE EPDXIED TO CONCRETE, USE HILTI "HIT-HY 200" EPDXY, AND INSTALL ANCHORS PER
MANUFACTURES SPECIFICATIONS. ADHESIVE ANCHORS SHALL ONLY BE INSTALLED IN CONCRETE WITH A
MINIMUM AGE OF 21 DAYS AT THE TIME OF ANCHOR INSTALLATION.
6. CONTRACTOR TO INSTALL FOUNDATION DRAINAGE PER IBC, SECTION 1805.
7. NO BACKFILLING AGAINST THE FOUNDATION IS TO BE DONE UNTIL AFTER THE HOUSE IS CONNECTED TO THE
FOUNDATION.
CONCRETE NOTES:
1. ALL CONCRETE WORK SHALL CONFORM TO THE APPLICABLE VERSION OF BUILDING CODE REQUIREMENTS FOR
REINFORCED CONCRETE (ACI 318) AND SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301)
REFERENCED BY THE BASE CODE MENTIONED ABOVE.
2. CONCRETE SHALL BE PROPORTIONED, MIXED AND PLACED IN CONFORMANCE WITH ACI 318 TO THE FOLLOWING
REQUIREMENTS;
* 3/4" MAXIMUM AGGREGATE SIZE
* FTG.: 3,000 PSI MIN. 28 DAY COMPRESSIVE STRENGTH W/ 4" MAX. SLUMP.
* FND.: 3,000 PSI MIN. 28 DAY COMPRESSIVE STRENGTH W/ 4-1/2" MAX. SLUMP.
* SLAB: 4,000 PSI MIN. 28 DAY COMPRESSIVE STRENGTH W/ 3" MAX. SLUMP.
4. CONCRETE SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL NOT BE
LESS THAN 5% OR MORE THAN 7%.
5. FLOWABLE FILL SHALL BE PROPORTIONED, MIXED AND PLACED IN CONFORMANCE WITH ACI 318 - MINIMUM STRENGTH
150 PSI AT 28 DAYS.
6. FLOWABLE FILL SHALL BE A LOW FLY ASH MIX THAT IS AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF
CONCRETE) SHALL NOT BE LESS THAN 15% OR MORE THAN 30%.
5. STEEL REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60. WELDED WIRE FABRIC SHALL CONFORM TO
ASTM A1064 GRADE 60, FOR DEFORMED AND PLAIN WIRE.
6. MINIMUM CONCRETE COVER OVER STEEL REINFORCING TO BE ACCORDING TO ACI CODE
* 3" IF CONCRETE IS POURED IN DIRECT CONTACT WITH THE GROUND.
* 2" IF CONCRETE IS EXPOSED TO THE EARTH OR WEATHER.
* 1-1/2" IF CONCRETE IS NOT EXPOSED TO THE EARTH OR WEATHER.
7. ALL SPLICES IN THE REINFORCING STEEL ARE TO BE TIED WITH WIRE, AND LAPPED AS FOLLOWS;
* #6 BARS AND SMALLER, LAP 35 BAR DIAMETERS.
* #7 BARS AND LARGER, LAP 45 BAR DIAMETERS.
8. AT NO TIME IS THE REINFORCING STEEL TO BE WELDED.
9. WHERE REINFORCING STEEL IS BENT IT IS TO BE DONE SO THE END RESULT IS A GRADUAL ARC WITH A MINIMUM OF A
THREE INCH RADIUS.
7. FORMS SHALL NOT BE REMOVED UNTIL THE FOLLING HAVE BEEN ATTAINED;
* BEAMS & SLABS - 500 DEGREE-DAYS HAVE PASSED OR CONCRETE HAS REACHED 30% OF THE REQUIRED
STRENGTH.
* WALLS & VERTICAL SURFACES - 200 DEGREE-DAYS HAVE PASSED OR CONCRETE HAS REACHED 30% OF THE
REQUIRED STRENGTH.
"DEGREE-DAY" = (TOTAL NUMBER OF DAYS)x(AVERAGE DAILY TEMPERATURE)
TEMPERATURES BELOW 50 DEGREES ARE NOT TO CONTRIBUTE TO DEGREE-DAYS
8. SLAB ON GRADE TO BE 4" THICK WITH ONE (1) LAYER OF 6x6 W4.OxW4.0 WELDED WIRE FABRIC LOCATED IN THE UPPER
THIRD OF THE SLAB.
9. TOLERANCE FOR FLATNESS OF THE SLAB IS NOT TO EXCEED 1/4" DIFFERENCE ACROSS 8', & 1/2" DIFFERENCE ACROSS
THE ENTIRE SLAB, UNLESS NOTED OTHERWISE.
10. DETAILS NOT SHOWN ON DRAWINGS SHALL BE IN ACCORDANCE WITH THE ACI DETAILING MANUAL 315
11. CONSTRUCTION OR CONTROL JOINTS IN THE SLAB TO BE AS SHOWN ON PLANS. WHERE NOT SHOWN, LIMIT CONTROL
JOINT SPACING TO NO GREATER THAN 15 FEET ON ANY SIDE FOR 5 INCH SLABS AND 12 FEET FOR 4 INCH SLABS ON
GRADE. THE SECTIONS BOUNDED BY CONTROL OR CONSTRUCTION JOINTS SHALL BE APPROXIMATELY SQUARE,
WITH THE LENGTH TO WIDTH RATIO LESS THAN 1.5.
12. CONTROL JOINTS ARE TO BE 1/4 OF THE TOTAL SLAB DEPTH AND ARE TO BE CUT USING A DRY SAW WITHIN 1 HOUR
AFTER FINISHING IN HOT WEATHER AND WITHIN 4 HOURS AFTER FINISHING IN COLD WEATHER
13. CONTROL JOINTS ARE TO BE FILLED WITH A SEMIRIGID EPDXY. CONTRACTOR IS TO DELAY FILLING THE JOINTS TO
THE MAXIMUM EXTENT POSSIBLE.
14. CONTRACTOR TO AVOID INTERSECTING FULL DEPTH CONSTRUCTION JOINTS WITH PARTIAL DEPTH CONTROL JOINTS.
15. CONTRACTOR TO DESIGN, ERECT, SUPPORT, BRACE, AND MAINTAIN FORMWORK TO SUPPORT VERTICAL AND
LATERAL LOADS TO CONFORM WITH THE APPLICABLE EDITION OF GUIDE TO FORMWORK FOR CONCRETE (ACI 347)
REFERENCED BY THE BASE CODE MENTIONED ABOVE.
16. CONTRACTOR TO PLACE CONCRETE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF GUIDE FOR MEASURING,
MIXING, TRANSPORTING, AND PLACING CONCRETE (ACI 304) REFERENCED BY THE BASE CODE MENTIONED ABOVE.
17. CONTRACTOR TO PROTECT CONCRETE WORK FROM PHYSICAL DAMAGE OR REDUCED STRENGTH WHICH COULD BE
CAUSED BY BOTH EXCESSIVE HEAT IN COMPLIANCE WITH THE APPLICABLE EDITION OF HOT WEATHER
CONCRETING (ACI 305), AS WELL AS FROST, FREEZING ACTIONS, OR LOW TEMPERATURES, IN COMPLIANCE WITH
THE APPLICABLE EDITION OF COLD WEATHER CONCRETING (ACI 306) REFERENCED BY THE BASE CODE MENTIONED
ABOVE.
V, Q
Q
• Q
E
(� \ w �
O
U
�.I
Q Q
V�J
Mcm
co
W �
cn
X
� a
U)ujQ
Q =
SEAL
REdWOms-
1
ADDED ROUGH CONTOURS
FOR EXCAVATION
11/30/2021
ZL
ISSUED FOR PERMITTING
11/29/2021
MSUEF FOR -
PERMITTING
RAVE. NOV. 29, 2021
SCALE. AS NOTED
DRAW Y- SRO
DEMGHED BY: SRO
I..L
LLI
O
LL
z W
Q
OU 0-
0
=
cl ~
~O
z `��
Uc
i'�
Z) �V
Oz
w
_>-
I-
-
3:U) U=j
Q =
W %� Q
O
z W
�
c*14 cn
BRAMONG VffLEo
PLAN &
NOTES
Dmmma NUMBER.
ST1
PAGE NUMBER:
1 OF
2
JOB NUMBER:
20-061 b
NEW (2) 2x8 SILL PLATES
(2) #5 REBAR TOP & BOTTOM I "
ANCHOR ROD (SEE NOTES)
d I a
PROPOSED 8" CONCRETE WALL
FOUNDATION WALL a
REINFORCING (SEE SCHEDULE)
ASPHALT EXPANSION JOINT
2x4 KEY WAY a
a
ATTACHEMT TO HOUSE
TO BE DESIGNED
- 8" MIN.
DO NOT BACKFILL THE
FOUNDATION UNTIL THE SLAB IS
CURED AND HOUSE IS ATTACHED.
4' (MINIMUM) FROST COVER
TO BOTTOM OF FOOTING
OR FLOWABLE FILL
8" WALL REINFORCING SCHEDULE
H U REINFORCING
8' <6' NONE REQUIRED
8' <8' #5 BAR @ 24" O.C.
STRIP FOOTING
as
2" MINI UM a a ° FLOWABLE FILL
a a / SEE NOTES
CLEAN SAND OR a \o/\\ \
:CRUSHED STONE... //�
DSEE PLAN /\/\/
p D FOOTING
L OUNDISTURBED O BED SOIL,
\\\\\\\
ILOR \\
(3) #5 REBAR BOTTOM OF FOOTING
1 FOUNDATION WALL DETAIL
ST1 SCALE: N.T.S.
REMOVE FLOWABLE FILL AT A 1:1
SLOPE TO PERMIT STRIP FOOTING
PROPOSED COLUMN
TO BE DESIGNED
4" CONCRETE SLAB
(SEE NOTES)
D Da.
D
D
D
p
p
a
2" MINI UM
a
CLEAN SAND OR
a
° a
9
CRUSHED STONE
SEE PLAN
FOOTING TO BEAR ON FLOWABLED
(3) #5 REBAR
FILL OR UNDISTURBED SOIL
BOTTOM OF
Q
FOOTING
EACH WAY
a
1D
a D
PREVIOUSLY PLACED
D
a
D
35d TYPICAL
D / °
/ a
FLOWABLE FILL BEYOND
D
a
/
FOOTING TO REMAIN
°D
p
—D— — —
a
/ a
Q 4
°
O
O\\\
°
/
a �.
/\\\
/
° PREVIOUSLY PLACED a
° °
p D
DD
D FLOWABLE FILL
UNDER FOOTING
g
REINFORCING TO a a a.
oD ° D
/ p
a TO REMAIN °tea
z
MATCH HORIZONTAL
WALL FOOTING
°�
a a °
a
D
Q as 4
a
o
/
°
g
a
a
D
°
°
5
BEARING TRANSITION DETAIL
UNDISTURBED SOIL
1D MIN.
SCALE: N.T.S.
a V a D D V /� a
\ \ D OPENING IN WALL D p/ D
D \ D o AS REQUIRED
\ a / D
\ 2'-0"
D D
D D
D D \ D D
D"D
D
FOUNDATION OPENING REINFORCEMENT DETAIL
SCALE: 1" = 1'-0"
(2) #5 BARS
ABOVE OPENING
(2) #5 BARS
DIAGONAL BARS
EACH CORNER
(2) #5 BARS
UNDER OPENING
2 STRIP FOOTING DETAIL
ST1 SCALE: N.T.S.
FOOTING TO BEAR ON PLOWABLE\\\\\\\\\/\\\\ (3) #5 REBAR
FILL OR UNDISTURBED SOIL \ \\\\\\\\\\\ BOTTOM OF
FOOTING
EACH WAY
3 STRIP FOOTING DETAIL
ST1 SCALE: N.T.S.
z
0
0
PITCH SLAB 1/8" PER FOOT
PROP. SLAB
(SEE NOTES)
FINAL GRADE
a—----�---
U
6"± BELOW T.O.S.
z
•
(2) #5 REBAR
TOP & BOTTOM
Q
#4 DOWELS @ 24" O.C.
24
FIELD BEND DOWELS
\
FND. WALL
AFTER WALL IS CURED
24
SEE PLAN
°
SEE DETAIL 1/ST2
FOR ADDITIONAL WALL
A A
REINFORCING
SEE PLAN
4 GARAGE SLAB DETAIL
ST1 SCALE: N.T.S.
D D D v
35d TYPICAL °
a
D ° D D
a a / )> p
° D a D °—
D D D
aD a
/
4'-0" MINIMUM
D p
D ° D
BOTTOM OF STRIP FOOTING
a
a D/ D // D 1 (WALL ABOVE NOT
p D ° ° / / / 2 SHOWN FOR CLARITY)
a /
X
� p
° Q
O
D
(V D a / a
° 1D MIN. d=BAR DIAMETER
a /
D D p 2D MINIMUM
a / / D=DEPTH OF FOOTING
D ° D
D D
D a 2
° 6 REINFORCING TO MATCH FOOTING STEP DETAIL
HORIZONTAL WALL FOOTING SCALE: N.T.S.
1 D MIN.
2x4 KEYWAY
(3) #5 REBAR TOP,
AT ALL GARAGE DOORS
(3) #5 REBAR BOTTOM
V, Q
Q
• Q
E
(� \ w �
O
U
�.I
Q Q
L
�U ��(� ��04
V�J
Mcm
��
Lwcn
X
c
U)wQq
I
SEAL
REWWOms-
\
NO CHANGES TO THIS SHEET
11/30/2021
\
ISSUED FOR PERMITTING
11/29/2021
MWED FOR -
PERMITTING
BAYS. NOV. 29, 2021
SCALE. AS NOTED
DRAW Y- SRO
DEMGHED Y- SRO
I..L
w
O
LL
z LIJ
Q
OU 0-
0
Q�
=
0 ~
z vu�
o
Z) CD
Oz
w
_>-
I- -Q=
3: U) U=j
W %� Q
O
z Lu
�
cal cn
BRAMONG VffLE:
DETAILS
Dmmma NUMBER:
ST2
PAGE NUMBER:
2 OF
2
JOB NUMBER:
20-061 b