Loading...
HomeMy WebLinkAboutEngineer Plans - 2021.� 9 LEGEND WEST YARMOUTH --� PROPOSED CONTOUR LOCUS RDU? ® PROPOSED SPOT GRADE 9 88 BERRY AVENUE -- gg -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE p/NF ST, —W— EXISTING WATER SERVICEgh¢ S TEST PIT w�N ST A. SCALE 1"=20' aR 0�"� Yarmouth Health Department ._Me45; 1 1 ELl iame Date STEVEN V1 RUMBA No: 35791 SURVEY BY: WELLER AND ASSOC. LEWIS BAy BLVD LOCUS MAP LOCUS INFORMATION PLAN REF: 106/151 TITLE REF: 32174/042 PARCEL ID: MAP 022 PAR. 098 FLOOD ZONE: NOT IN FLOOD ZONE SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 99 BERRY AVENUE WEST YARMOUTH, MA PREPARED FOR LEVEE BREAKS INV. GROUP LLC MARCH 25, 2021 OF MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5@gmail.com SHEET 1 OF 2 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS SEPTIC TANK T.O.F. EL.=20.0± INSTALL RISERS & COVERS OVER INLET & PROPOSED D -BOX OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & COVER INSTALL LOCKING COVERS IF AT FINISH GRADE SET TO 6" OF GRADE /-F.G. EL.=18.90± F.G. EL.=18.90± F.G. EL: 18.90± 9" MIN COVER/ tj 36MAX COVERL = 20' O S=1% (MIN.) EL -17.701 O S=1% (MIN.) 4"SCH40 PVC r PVC INV.=16.65_/ 1 -11111.3 48' LIQUID INV.=16.40 LEVEL \ ... .. GAS BAFFLE. INV.=16.20 PROP, 1.500 GALLON SEPTIC TANK EXIST. SEWER OUTLETS AQ INV. 17.25 ® INV. 18.17 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. 2) TANK AND D -BOX SHALL BE SET TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL PVC INLET/OUTLET TEES IN SEPTIC TANK AS REQUIRED. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. DESIGN CRITERIA O S=1%( 15'(MN.) 4"SCH40 PVC INV.=1 BREAKOUT=TOP ELEV.=15.89 INV. ELEV.= 15.50 BOTTOM ELEV.= 14.56 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:15.89 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL A 4" DIAMETER INSPECTION PORT OVER ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. /-F.G. EL: 18.80(MAX.) 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. (5.09' PROVIDED) ADJUSTED GROUNDWATER: EL:9.47- SEPTIC SYSTEM PROFILE N.T.S. NUMBER OF BEDROOMS: 3 BEDROOM DESIGN DESIGN FLOW: RESIDENTIAL: 3 BEDROOMS 0 110 GPD/BR - 330 GPD DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) GARBAGE GRINDER: NO (not designed for gorbage grinder) DISTRIBUTION BOX: USE DB -5 (1-120) SEPTIC TANK: 330 gpd x 450% = 1,485 gpd USE PROP. 1,50OG SEPTIC TANK LEACHING AREA REQUIRED: (330)/.74 = 445.94 S.F. PRIMARY S.A.S. USE 4 ROWS OF 6 - INFILTRAOR QUICK 4 HI -CAP UNITS -NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER) 24 UNITS x 4 LF x 4.73 SF/LF = 454.08 SF TOTAL AREA = 454.08 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(454SF) = 336 GPD > 330 GPD req'd INSTALL TWO INSPECTION PORTS (MIN.) 4 ROWS OF 6 UNITS AT 4'/UNIT = 24'/ROW SOIL ABSORPTION SYSTEM (PROFILE) RESTORE VEGETATIVE COVER SAND COVER UNITS W/ FILTER FABRIC PRIOR TO BACKFILL EXISTING SUITABLE MATERIAL EFFECTIVE WIDTH = 4 x 2.83' = 11.3 USE 4 ROWS OF 6 -HIGH CAPACITY INFILTRATOR (1-120) UNITS TYPICAL SECTION MTA SOIL LOGS DATE: MARCH 9, 2021 SOIL EVALUATOR: DARREN M. MEYER, RS, CSE WITNESS: MALLORY LANGLER, YARMOUTH HEALTH Elev. TP -1 Depth 19.0 A 0" LOAMYSAND IM 3/2 18.33 8" B LOAMY SAND 1oYR s/e 15,50 42" PERC TEST C MEDIUM SAND O EL 15.0 2.5Y 7/3 11.0 96" FINE SAND 2.5Y 6/4 71 PERC RATE <2 MIN/IN. ('C' HORIZON) GROUNDWATER OBS O 138' EL 7.67 WELL: MIW-29, ZONE 8, LEVEL 8.5, ADJ: 2.8' USE EL 1.8' AS ADJUSTMENT PER BOH ALLOWABLE 1 Fr. REDUCTION. USE ADJ GW EL 9.47 • I, Darren M. Meyer, R.S., CSE, hereby certify that I ant currently approved by MADEP pursuant to 310 CMR 15.017 to conduct will evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam in October, 1999. OF GENERAL NOTES: 1. ALL CHANGES TO THIS PUN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT USTED ON PAGE 1. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWEUJNG IS SERVICED BY MUNICIPAL WATER. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING CESSPOOLS TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND. 11. 48 HOUR NOTICE FOR ENGINEER CERITFICATION 12. THIS PUN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 O 1/8"/FT (UNLESS SPEC.) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. INSTALLER TO VERIFY ALL OUTLETS PRIOR TO INSTALLATION. SECTION 11.5" J INWEHT END CAP INFILTRATOR - QUICK 4 - HI CAPACITY (H20) CHAMBER PROPOSED SEPTIC SYSTEM UPGRADE PLAN 99 BERRY AVENUE, WEST YARMOUTH, MA Prepared for: Levee Breaks Investment Group, LLC System Design and Site Plan by: SCALE DRAWN DATE MEYER &SONS, INC. N.T.S. DMM 03/25/2 PO BOX 981 EASTSANOWICH, MA 02537 CHECKED SHEET NO. 5M -M22922 DMM 2 of 2 11