HomeMy WebLinkAboutEngineer Plan - 2021SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2' PEASTONE OR GEOTEXTILE 28,7'FILTER FABRIC OVER STONE 2�r PRECAST H-10 RISERS (TYP.) 2'0 ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 25.0'-2� WATERIEST D'BOX FOR LEVELNESS BLOCKS OR MIN. 2" WALL THICKNESS PRECAST RISERS 4"OSCH40 PVC MORTAR ALL PIPES LEVEL 1ST 2' 4' COMPONENTS INVERT IN 232 ENDS (TYP.) DES 1500 GAL H-10 14" ;oS00000v: ,.,e.. ri SIDES 23.81' TEE SEPTIC TANK TEE ®®®® ®®®® ®®®® ®®® 3.56' ° 6" MIN. SUMP ®®®®®®®®®®® MM GAS RAFFLE:: °�o�o°a°o"°° 12" MIN. INT. DIM. 4' UD. LEVEL (ACME OR EQUAL),[ 23.47' 23.3' } 21 $°000°000.00$o$ooao°oo°°o°oeo°o 1 H-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUA I 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. ALL AROUND PRECAST STRUCTURES (2) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [21) (2_3 % SLOPE) (--!-% SLOPE) (!-% SLOPE) FOUNDATION- 17' SEPTIC TANK 9' D' BOX 12' LEACHING FACILITY ADJ. G.W. EL.= 16.2' G.W AT EL.= 15.0' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- EGEND99- 99- EXISTING CONTOUR X 88.1 EXIST. SPOT ELEV. -[99}-- PROPOSED CONTOUR (98.4] PROPOSED SPOT EL. TH1 Y TEST HOLE vlo SLOPE OF GROUND c° 0 UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING 0 22 � q TEST HOLE LOGS o ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: BRUCE MURPHY Z25 i DATE: 11/4/21 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0" 24.5' / 18" UNSUITABLESOIL B SOIL r110YR 5/4 26" i / / / / 2.5Y 6/4 48" 20.5' BED PERC C2 G -W ADJ. DATA: VN M/CS WELL: SDW 252 ZONE: A BED 2.5Y 7/3 ADJ: 1.2' 132" I 113_5' .W. FOUND AT 114" EL. 15.0' DICE #29-377 EA W 21 w� NOTES 1. DATUM IS yQW 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -]SI 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR L -1 AND IFYING ITHE CATION o Locus 0 VERLUNG LOGSAFE OF ALLUNDERGROUNDRGROUND & o� OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE � F c° 0 v d ASSESSORS MAP 149 PARCEL 61 BE REMOVED BENEATH AND 5' AROUND THE Rte 6A 10. CONTRACTOR SHALL BE RESPONSIBLE FOR AND IFYING ITHE CATION LOCUS MAP VERLUNG LOGSAFE OF ALLUNDERGROUNDRGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000'± WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 149 PARCEL 61 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FLOOD HAZARD) AS AND REMOVED OR PUMPED AND FILLED WITH CLEAN SHOWN ON COMMUNITY PANEL #25001CO576J SAND. DATED 7/16/2014 ,ate y�-7e O SYSTEM DESIGN: DOWN TO SUITABLE SOI REMOVAL UNSOITAB E SOIL REQUI D A 26 lj AROUND PERIMETER LEACHING FACILITYF y-� OIrLAYER. REPLACE WITH CLEAN MED. SAND, TO MEET GARBAGE DISPOSER IS NOT ALLOWED �' SPECIFICATIONS OF 310 MR 15.255(3) X22 EXISTING 2 BR DWELLING (SYSTEM DESIGNED FOR 3 BR) cD �A O --DESIGN FLOW: 3 BEDROOMS @ 110 GPD 330 GPD /i BENCHMARK: USE A 330 GPD DESIGN FLOW BOUND DH Hey TH1 =23.8' NAVD88 � SEPTIC TANK: 330 GPD (2) = 330 L Iu EXISTING C:2 USE 0 USE A 1500 GAL. SEPTIC TANK DLV ,I 2021 DWELLING PROVIDE 39' OF 40 MIL UN AT 5 TOF = 28.7' L®` OFF SAS IN AREA SHOWN. T AT LEACHING: HEALTH DEPT. r'� 1 ELEV. 24.03', BOTTOM AT EL. 2 03'1 SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD 2> / GARAGE >' / TOTAL: 472 S.F. 349 GPD � � / / i D k 22.3 / l •0' USE (2) 500 STONE L. LEACHING CHAMBERS (ACME OR EQUAL) W L v `30 16,067 d 0 46711 SUNROOM BATH 7KITCHENDINING BATH GARAGE LMNG DEN/OFFICE ROOM FLOOR PLAN (N.T.S.) i �0) / 29 c c L 24� ��- / ABUT DWELLING Yarmouth Health Department PROVED Name Date Scale: 1"= 20' 0 10 20 30 40 50 FEET M�S�>AJA{f 671.w= DATE DANIEL A. OJALA, P.E., P.L.S. MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 120 HOMERS DOCK RD YARMOUTH PORT, MA PREPARED FOR DOREEN DELMONACO DATE: NOVEMBER 8, 2021 I off 508-362-4541 fax 508-362-9880 downcape.com down cape engineering, kC. civil engineers land surveyors 939 Mcin Street ( Rte 6A) YARMOUTf-1PORT MA 02675 21-377 DELMONACO.DWG