Loading...
HomeMy WebLinkAboutEnigneer Plan - 2021Permit valid for REPAIR OF SEPTIC SYSTEM ONLY, due 14) State and l.ocni septicvariances. _ Board of Health hr%iew and approNW Is required for any future add Itiuns/renuv'atinuN.Iterations . to Sewage facilities ampor structures/dot thing. Yarmouth Ilcalth Dana' nncnl '.... APPROVED Name I Date LEGEND - —: 67.--- .EXISTING CONTOUR x 700.98 EXISTING SPOT GRADE. OVERHEAD WIRES — W— EXISTING WATER SERVICE TEST PIT :BENCHMARK ITN. MA0267- h O m LOCUS' MAP CATCH BASING ?% 98.8 100.05 100.54 : EXISTING S.A.S(INFILTRATORS TO BE REMOVED IF WITHIN 5 T. 98,93 "off F. OF PROPOSED S.A.S.-SEE NOTE 11 0 O F 101.13 EXISTING SEPTIC 1. 7 TP ,y`f�FNr TANK, E 10 TOP35. OF INV (OUT) 100.00± 99.54 101 1 3 ENCNMARK � � s39800� � �. I01:60 . WOODED 103 0 COR./GARAGE APRON EL.=102.79 x - p \ 03� \ LAM R 1'�S 10175 + ��. / 102 - / . 23. N of + 02.66 ( 110 O` Pq! r' VENT 108.47 l02 6� GARAGE; 100.17 SLAB E[:%8t "`� PROPOSED S.A.S. E 13' x 35' LEACH FIELD � 3 � PORCH W/ 2 DISTRIBUTION LINES 101.79 M. 7 / 0 �' f 'J PARTIAL STRIPOUT _-�" SEE NOTE 11 W 'a01.84 EXISTING W 'HOUSE(#4) e To.F=VAR/ESI / LOT 4 0 Q o c 102.73 � t ' x1 �� 13,825±S.F. •ti Z ('� 10313.x :0 10 .65 10420 105.40 3� W i / 1013.0 JOHN l . x ...... H L Jif �..\ I x 105:44 /V f n,� h0. 66 Yc ID .08 �`° 'pF 10 ;7 x .107.07 i. t dgT I 103.95 1F104 73 W (a prox.) \ I0 5 SPKW107.60 :. 10512 103 68x x ,58 �: o � N r S 7840'17" E �\ Z or PETER T- MCENTEE N .�. CIVIL . 35109 OWNER OF RECORD 3 NORTON, JOHNA -JR r: NORTON, WILLIAM PLAN REVISION 12/13/21' P.O. BOX 129 YARMOUTH PORT, MA 02675 REVISE & RELOCATE S.A.S. p/+ PARCEL ID: 106-88- 91nee�. Surveyor: 50A°RAWN J°B. N0 PROPOSED SEPTIC SYSTEM UPGRADE PLAN ngineering Works, Inc. KEngineering, Inc. 2854 Cranberry. Hwy. "=20' P.T:M. 270-2t 4 FREEMAN ROAD, YARMOUTH 'PORT, MA DATE - :CHECKED 10/2721 P:T. M. SHEEP N0. 1 of 2 2. West Crossfield Road orestdale, MA 02844 ' E.Wgreham, MA 02538 Prepored-for: Cape Bad Septic Services, 350 Main St., W. Yarmouth, MA 02673 508) 477-5313 (508) 273-0377 NOTE: TO PREVENT BREAKOUT, FINAL". GRADE SHALL .NOT BE AT, OR. BELOW, EL.=99.83 - FOR A DISTANCE OF 15' FROM THE EDGE SEPTIC TANK PROPOSED D-80OF THE PROPOSED S.A.S. INSTALL RISERS "& COVERS' OVER INLET & INSTALL RISER & COVER' OUTLET AND SET TO 6" OF FINISH GRADE SET'. T0. 6" OF: GRADE PROPOSED SA.S SLAB EL=102.81 INSTALL INSPECTION PORT OUTSIDE DRIVEWAY FOOTPRINT F.G. EL=:103.6± F.G. EL.= 103.0± F.G.. EL.=103.03 ao 104.03 MANIFOLD LINES. MAINTAIN 2% GRADE MIN. OVER S.A.S. ... .., i, 4" 01 M. INSPECTION PORT, L 39 L ®: e'(wx) +3' z 35' LEeCHING FIELD W/2-4" PERFORATED IN S:A.B.. SOLID ®. s_1% (MIN.) ®.S=t%.(MIN.) ABOVE S.AB WITH SCREW CAP ET ITHI J f G 4"SCH40 PVC. 4"SC640 PVC MANIFOLD LINES " to" to 6 6"EFF.DEPTH INV:=36.06 I SLOPE OF PERF. PIPE = 0.5% I INV, EL.-99.15(END) EXISTING 487. UOUID LEVELApp PROPOSED 35' EFFECTIVE LENGTH INV.=99.60 INV.=99.43 GAS BAFFLE D BOX SOIL ABSORPTION SYSTEM (PROFILE) .. ...... .. INV.=100.00 3OUTLETS (VERIFY) INV.=99.33 EXISTING SEPTIC TANK ESTABLISH VEGETATIVE COVER FINISHOF Ho to -1.... 1./8"LAYER t1 S ONE, OR, NOTES: APPROVED 1) CONTRACTOR. SHALL VERIFY ALL EXISTING PIPE FILTER FABRIC INVERTS, PRIOR TO INSTALLATION. BREAKOUT ELEV.=99.83 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE BOTTOM ELEV.=98.65 3/4"-1:1/2" DOUBLE ON A MECHANICALLY COMPACTED STABLE BASE OR. WASHED E 3'5 8 3.5' SIX INCH AGGREGATE BASE, AS SPECIFIED IN 310 5' MIN. SEPARATION TO G W. CMR 15.221(2). AND 4' OF NATURALLY 13' EFFECTIVE WIDTH. 3) INSTALL INLET & OUTLET TEES AS REQUIRED. OCCURRING PERVIOUS SOILS SOIL ABSORPTION SYSTEM (SECTIONI 4)A GAS .BAFFLE SHALL BE INSTALLED ON. OUTLET TEE AS MANUFACTURED BY TUF-TITE, 2ABEL OR EQUAL EST. HIGH G.W. EL 93.60 SEPTIC SYSTEM PROFILE SOL LOCI GENERAL NOTES: 1, ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. DATE: OCTOBER 21, 2021 SOIL EVALUATOR: PETER McENTEE SE#1542 2, ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS WITNESS. PHIL RENAUD HEALTH AGENT. OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE ELEV. 'TP- I DEPTH LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: 0' -310 .CMR 15.405(1)(b): LOCAL UPGRADE APPROVAL 101.1 Ab 1) A 2' variance to depth of cover, for 5' of cover over S.A.S. LOAMY SAND 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR999 IOYR 4/2 14" : TO INSPECTION AND. APPROVAL.. BY THE BOARD OF HEALTH AND THE B DESIGN ENGINEER. ` LOAMY SAND 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING 10YR 5/6 FROM: THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN PERC ENGINEER BEFORE CONSTRUCTION CONTINUES. 98.0 O 37"29"/37". 5. ALL. ELEVATIONS. BASED ON AN ASSUMED. DATUM. 6.. THE DESIGN' ENGINEER ISNOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. F -M. SAND 2.5Y 5/3 7. WATER SUPPLY PROVIDED BY. TOWN WATER SERVICE.. 8. THERE ARE NO ABUTTING. WELLS WITHIN 100' OF THE PROPOSED S.A.S... 9. ALL AREAS CLEARED. FOR CONSTRUCTION SHALL BE RESTORED AS. 93:6 ADJ. GW' 90" REDOX 7.5YR 5/5 _ AGREED UPON BY: OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED- BY THE APPROVING AUTHORITIES. 90.3 STDG. GW _ 130" 10. IT: SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY S94 140 THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING PERC RATE G2 MIN/IN. "B" HORIZON CONSTRUCTION. STANDING GW AT 130", REDOX AT X90" 11. WHERE. REQUIRED, CONTRACTOR SHALL' REMOVE ALL UNSUITABLE SOILS IN THE AND SIDESOF THE S. AND REPLACE WIITTHBCLEANHSAND ASRSPECIFIED IN CMR 255(3), 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER. PRIOR TO BACKFILL of 13.. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND pA�'E.y NOT CONSIDERED TO BE A PROPERTY. LINE SURVEY. F 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON: THE PLAN.: �3s DESIGN CRITERIA '..NUMBER OF BEDROOMS: 3 :. \� �1 SOIL TEXTURAL CLASS: CLASS (LOADING RATE=0.74 GPD/SF) : h//1r� DESIGN PERCOLATION RATE: <2'MIN/INy 2' N Hj DAILY FLOW. 330 GPD 330 GPD. / J 46'( �� DESIGN FLOW: : ^M GARBAGE GRINDER: NO -not allowed with design ' 38.2' `c LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF GARAGE _74 GPD/SF 5[.48 EG. -707,8/ EXISTING SEPTIC TANK: '1500 GALLON CAPACITY PROPOSED D -BOX' 1 INLET, 3 OUTLET (MINIMUM), H-20 RATED ECH ,y6.`b PaR I INSTALL AN 13' x 35' LEACH FIELD i --_ PROPOSED. S.A.S. SIDEWALL AREA: NOT APPLICABLE '. /EXISTING 13'x 35' LEACH FIELD BOTTOM AREA:. 13' x 35' - 455 S.F. i /-/Q(J$E� F¢�W/ 2 DISTRIBHTION LINES TOTAL. AREA:....... '.......... ........455: S.F. SEPTIC. LAYOUT . LEACHING CAPACITY 0.74 GPD/SF x 455 SF: = 336.7 GPD ngtnae Survey.= _ SCALE DRAWN JOB. NO. PROPOSED SEPTIC SYSTEM UPGRADE PLAN e: nginling Works, Inc. JC Engineering, Inc. Hwy' N.T.S. P.T.M. 270-21 4 FREEMAN ROAD, YARMOUTH PORT, MA DATE 10/27/21 CHECKED SHEET NO. 2 of 2 2 West CrossSeld Rood orestdale, MA 02644 2654 Cranberry E.Wamham; MA 02538 Prepared for: Cape Cod Septic Services, 350 Main St.,. W. Yarmouth,MA 02673 506).477-5313 (506) 273-0377P.T.M.