Loading...
HomeMy WebLinkAboutEngineer Plans - 2021m 97 98 o/ I a6o I j in 0 98.4 39 -Em tree x SAV e 4 5 i z 96.7. F s Q w 18" tree od 3 e� spike o, A 2 - _ SLP) ---_\ \ _ s'fi`_o 4 .PARCEL 51047,088 SF) ASSESSORS MAP: 51 PARCEL: 56 PLAN BOOK: 73, PAGE: 51 9 96.1 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: (10 ROOMS 12=5 BEDROOMS) 5 BEDROOMS AT 110 GAL / DAY = 550 GAL / DAY SEPTIC TANK: 550 GAL /DAY x 2 DAYS = 1100 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 4 - 500 GALLON CHAMBERS (8.5' x 4.8' x 7 EFF. DEPTH) WITH 4' OF STONE ALL AROUND (42'x 12.8'x 2' DEEP) SIDE AREA: (42'+ 12.8') x 2 x 2 = 219 SF (0.74) = 162 GAUDAY BOTTOM AREA: 42'x 12.8'= 538 SF (0.74) = 398 GAUDAY CAPACITY <RLAUDAY 42.0' LEACH AREA DETAIL ARKAT FINER OF FEP DN= 97.96 %cp ) Po — 97 \ 1oP) 72" tree _ �Sfone \ 96 Parking J m \98 r,�99 / O.H.W,_ �l-\ e'PS '.t�6�0 D�G9h° o. � O��E° Qoco✓ �j SEPTIC SYSTEM SECTION / FLOOR 99.49 COVERS WITHIN 6" VVV 0° a TOP OF OF FINISHED GRADE FOUNDATION 1/4"per ft t^ (3 bath. I bath. 1 JI bed room rbo�om F — bed bad room oom 2nd FLOOR 1500 GAL SEPTIC TANK M 6' OF STONE UNDER OR ECHANICALLY COMPACTED) a TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN PEASTONE OR FILTER FABRIC 31,V'- 1 1/2" DOUBLE WASHED STONE INSPECTION PORT �FLEV. 9.33 1/8" Per It ELEV.ELEV. It=l 4 ° ° I'Iftg6el D -BOX 4 (6" STONE UNDER) 42'x 12.8' 9 5 4 - 500 GALLON CHAMBERS WITH ELEV. ✓ (42' x 12.8' STONE FFECTIVEUDEPTH) - GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 7-11.19 PERCOLATION RATE: < 2 MIN/IN TH-1 O/A HORIZON LOAMYSAND 10YR 4/1 B HORIZON LOAMYSAND 10YR 5/8 C HORIZON FINE SAND 2.5Y 7/4 PERC AT 42" 97.0 Ems- NO GROUND WATER ENCOUNTERED TERRY ANN WARNER No. 38721 --jam "'►17 KEY: EXISTING CONTOUR: — — — PROPOSED CONTOUR: •------"----- EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLEY UTILITY POLE: FENCE UNE: - HYDRANT; .b. RETAINING WALL: REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING CESS POOL IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED.. ANY ADDITIONAL CESS POOLS FOUND DURING CONSTRUCTION ARE TO BE PUMEED AND FILLED OR REMOVED. EXISTING DWELLING WAS BUILT 170 YEARS AGO. ,✓ 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. CML NIL 30471 ,,. �,.r. _.... Q— II THOMAS J. McLELLAN, P.E. Permit valid for REPAIR OF S Fl -IC, SVST ONLY, due to... State and. Loral septiic'�variar Board of IleaHh review and approval is. required any falure add ikons/rcndrations/a Iterations sewage lardities and/or structures/dwelling;. Yarmouth Health De parfinenl A PPRO V P lY SITE PLAN LOCATION: 162 OLD MAIN ST., S. YARMOUTH, MA PREPARED FOR: REBECCA HOWES BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 02641 508-3649048 1"=30'/ kitchenNOTES: 1. VERTICAL DATUM: ASSUMED dining 2. MUNICAPAL WATER IS AVAILABLE. room 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. bath 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. - bath 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). livin room - / 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. s/ office 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL, 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL den CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. room 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. parch 10. GROUND COVER OVERALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 1st FLOOR 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE EXISTING FLOOR PLAN TERRY ANN WARNER No. 38721 --jam "'►17 KEY: EXISTING CONTOUR: — — — PROPOSED CONTOUR: •------"----- EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLEY UTILITY POLE: FENCE UNE: - HYDRANT; .b. RETAINING WALL: REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING CESS POOL IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED.. ANY ADDITIONAL CESS POOLS FOUND DURING CONSTRUCTION ARE TO BE PUMEED AND FILLED OR REMOVED. EXISTING DWELLING WAS BUILT 170 YEARS AGO. ,✓ 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. CML NIL 30471 ,,. �,.r. _.... Q— II THOMAS J. McLELLAN, P.E. Permit valid for REPAIR OF S Fl -IC, SVST ONLY, due to... State and. Loral septiic'�variar Board of IleaHh review and approval is. required any falure add ikons/rcndrations/a Iterations sewage lardities and/or structures/dwelling;. Yarmouth Health De parfinenl A PPRO V P lY SITE PLAN LOCATION: 162 OLD MAIN ST., S. YARMOUTH, MA PREPARED FOR: REBECCA HOWES BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 02641 508-3649048 1"=30'/