HomeMy WebLinkAboutEngineer Plan - 2021Mop 74
Parcel 37
N 82-564()"
48—
Shed
8,Shed P1
\\ 23,
See Note #4
f^+
( l
See Excavation Notes Tree + '
— +1
14" 1
+ TreeTP
+'
�16�-
Al RI1+ST
T = 50.0
Topop sConcrete
(Assumed) sumed) '
Mop 74
Parmit valid: for REPAHMPSOTIC. SYST
ONLY, due to State and Local septic varian
Board of Health review and approval is required
any future additions/renovations/alterations
sewage facilities and/or structures/dwelling.
Yarmouth Health Department
APPROVED
+�
SASk
N 61'26'52 E
3 L t7 2 G 55 I 'lPB 258 PG 77
oLot 3
305± Sq. Ft. f
' �`` 17,390.1 Sq. Ft.
1
See Note g19+�,
f r
'Shed i
Total Lot Area
r o., �l� 40,695± Sq, Ft
4
52
I
`,–tel/M 1 11 House 3 Bedroom 6
1
Geroge (1 + TOF EI = 54.5
slab = 51.01,
' 52
5
�0
+ ' 85048
1
Mn, gar
± o/w Il •w� S-15
465A! W –
da `t �l'`-de Line
e
Gv1Gk b+�c Vo`)
(po
L---
NOTE:
LOCATION OF UTILITIES IS APPROXIMATE AND ALL
UNDERGROUND AND OVERHEAD UTILITIES MUST BE
DETERMINED IN THE FIELD PRIOR TO COMMENCEMENT
OF ANY WORK, THIS INCLUDES, BUT NOT LIMITED TO,
REQUESTS TO DIGSAFE, ANY PRIVATE UTILITY COMPANIES
AND THE LOCAL WATER DEPARTMENT.
GRAPHIC SCALE
30
( IN FEET )
1 inch = 30 ft.
Mop 74 '
Parcel 74
d
s
0
Locus
N
l4 eta p 0
6
Marguerite E. Small
Elementary School
West Yarmouth, MA
SITE LOCUS
NOT TO SCALE
1.) Assessor's Mop 74 Parcel 72
2.) Bk. 10311 Pg. 71
3.) Plan Book 237 Page 955
4.) This property is in the Zone 11
Water Protection District
5.) This property is in Flood Zone X
Firm Map 25001CO586J 7/16/14
Proposed Septic Plan
36 Chickadee Lane West Yarmouth, MA
Prepared by:
Prepared for: All Cape Septic and Survey
Jhonatan Silva 618 Route 28
West Yarmouth, MA 02673
(508) 771-4200
allcopesep ticogmoil. com
72/07/21 Sheet t of 2 By. MA Check: SM Dwg. #399
CONSTRUCTION NOTES
1.) ALL WCRK SMALL CONFORM To THE STATE ENVIRONMENTAL CODE, TITLE 5 (310 CMR 15.00:
STANDARD REOUIREMENTS FOR THE SITING, CONSTRUCTION, INSPECTION. UPGRADE, AND
EXPANSION OF Ort -SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS AND FOR THE TRANSPORT
AND DISPOSAL OF SEPTAGE, AND THE LOCAL BOARD OF HEALTH REGULATIONS,.
2.) ANY SEPTIC SYSTEM COMPONENT INSTALLED IN A LOCATION WHERE n1ERE IS POTENTIAL FOR
VEHICLES OR HEAVY EQUIPMENT TO PASS OVER IT SHALL BE DESIGNED TO WITHSTAND AN H-20
LOADING. IF UNDER AN IMPERVIOUS SURFACE, SYSTEM SHALL BE VENTED TO THE ATMOSPHERE.
3.) TO MINIMIZE UNEVEN SETTLING, SEPTIC TANKS AND D -BOX SHALL BE INSTALLED ON A STABLE
MECHANICALLY -COMPACTED BASE ON SIX INCHES OF CRUSHED STONE.
4.) COVERS OVER THE INLET AND OUTLET TEES OF THE -SEPTIC TANK, THE DISTRIBUTION BOX, AND
THE SOIL ABSORPTION SYSTEM SHALL BE RAND TO WITHIN 6'" OF FINAL GRADE LEACHING 46A
FIELDS, TRENCHES, AND OTHER SOIL ABSORPTION SYSTEMS WITHOUT -ACCESS MANHOLES SHALL
HAVE AT LEAST ONE (1) INSPECTION PORT CONSISTING OF PERFORATED 4' PVC PIPE PLACED
VERTICALLY TO THE BOTTOM OF THE SOL ABSORPTION SYSTEM WITH A CAP, TIED YWTH MAGNETIC
MARKING TAPE. ACCESSIBLE TO WITHIN 3' OF FINAL GRADE.
5.) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT. PIPE SHALL BE LAID ON A
MINIMUM CONTINUOUS GRADE OF NOT LESS THAN 2% FROM THE BUILDING TO THE SEPTIC TANK.
AND NOT LESS THAN 1% OTHERWISE.
6.) DISTRIBUTION LINES FOR THE SOL ABSORPTION SYSTEM SHALL BE 4" DIAMETER SCHEDULE 40
PVC (OR EQUIVALENT) LAID AT 0.005 FT/FT. UNLESS OTHERWISE NOTED. LINES SHALL BE CAPPED
AT END OR AS NOTED.
7.) LINES FROM THE DISTRIBUTION BOX TO BE LEVEL FOR THE FIRST TWO (2) FEET BEFORE
PITCHING TO THE SOL ABSORPTION SYSTEM. DISTRIBUTION BOX SHALL BE WATER TESTED TO
ASSURE EVEN DISTRIBUTION.
8.) GROUT TO BE USED AT ALL POINTS WHERE PIPES ENTER OR LEAVE ALL CONCRETE STRUCTURES "
IN ORDER TO PROVIDE A WATERTIGHT SEAL
9.) HEAVY EQUIPMENT S14ALL NOT BE ALLOWED TO OPERATE OVER THE LIMITS OF THE SEWAGE
DISPOSAL FIELD DURING THE COURSE OF CONSTRUCIM OF THE SYSTEM -
10.) IN
YSTEM.10.)IN ACCORDANCE WITH 310 CMR 15.221, ALL SYSTEM COMPONENTS SHALL BE MARKED WITH
MAGNETIC MARKING TAPE.
1t.) THERE ARE NO KNOWN WELLS OR WETLANDS WITHIN 15V OF THE PROPOSED SOL ABSORPTION SYSTEM.
12.) FROM THE DATE OF THE INSTALLATION OF THE SOIL ABSORPTION SYSTEM UNTIL RECEIPT OF
THE CERTIFICATE OF COMPLIANCE, THE PERIMETER SHALL BE STAKED AND FLAGGED TO PREVENT
USE OF THE AREA THAT MAY CAUSE DAMAGE TO THE SYSTEM.
13.) THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UNLESS
CONSTRUCTED AS SHOWN ON PLAN. ANY CHANGES SHALL BE APPROVED IN WRITING BY THE ENGINEER.
14.) THE BOARD OF HEALTH REQUIRES INSPECTION OF ALL CONSTRUCTION BY AN AGENT OF THE
BOARD OF HEALTH AND THE DESIGNER. THE DESIGNER SHALL CERTIFY IN VOTING THAT THE
SEWAGE DISPOSAL SYSTEM WAS INSTALLED IN ACCORDANCE WITH THE TERMS OF THE PERMIT
AND THE APPROVED PLANS. 48 HOURS ADVANCE NOTICE IS REQUESTED.
15.) LOCATION OF UTILITIES IS APPROXIMATE AND CONTRACTOR SHALL BE RESPONSIBLE FOR
DETERMINING THE LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO
COMMENCEMENT OF ANY WORK. THIS INCLUDES, BUT IS NOT LIMITED TO, REQUESTS TO DIGSAFE,
ANY PRIVATE UTILITY COMPANIES, AND THE LOCAL WATER DEPARTMENT.
1G) CONTRACTOR SHALL VERIFY THAT ALL WASTELINES ARE CONNECTED BY WATER TESTING
WTHIN THE DWELLING PRIOR TO INSTALLATION OF ANY SEPTIC COMPONENTS.
17.) CONTRACTOR SHALL VERIFY EXISTING INVERT ELEVATIONS PRIOR TO INSTALLATION OF ANY
SEPTIC SYSTEM COMPONENTS.
18.) TEST HOES COMPLETED PER STATE ENVIRONMENTAL CODE, TITLE 5_ SOLS CAN BE
VARIABLE AND TEST HOLE DATA IS NO GUARANTEE OF SOIL CONDITIONS IN OTHER AREAS. IF
SOILS DIFFER FROM TI0SE SHOWN IN THE SOLS LOGS, DESIGN ENGINEER LS To INSPECT THE
SOLS PRIOR TO PROCEEDING WITH INSTALLATION OF ANY SEPTIC COMPONENTS.
19.) EXISTING SEPTIC COMPONENTS TO BE LOCATED, PUMPED DRY, FILLED VITH CLEAN SAND AND
ABANDONED IN PLACE OR REMOVED AS REQUIRED. AREA TO BE COMPACTED TO MINIMIZE SETTLING
EL=54.5±
EXCAVATION NOTES
i) HEOLEAVATE: ALL LOG) WHEREATERIAL ABOVEPOSSIBLE OR ALATERALHORIZON
DIS ANCE OF E5 OBSERVATION
IN ALL DIRECTIONS BEYOND THE OUTER PERIMETER OF THE LEACHING AREA,
2) FILL MATERIAL SHALL CONSIST OF CLEAN GRANULAR SAND, FREE FROM ORGANIC
MATTER AND OTHER DELETERIOUS SUBSTANCES, WHICH MEETS THE TEXTURAL
CRITERIA PUT FORTH IN SECTION 15.255(3) OF TITLE 5.
3) SCARIFY THE BOTTOM SURFACE OF THE EXCAVATION PRIOR TO PLACEMENT
OF FILL INTO THE RETAINING STRUCTURE.
4) PLACE FILL ONLY WHEN BOTTOM SURFACE IS DRY.
50.0
s J-�
o
GAS BAFFLE
D813 H-20
D -BOX
1,500
GALLON
SEPTIC TANK
FLOW PROFILE
NOT TO SCALE
Test Hole 1 (EL=47.5±)
l G3 I MULL LUV
Depth
Elev.
Layer
Soil Class
Soil Color
0 - 11"
49.1
A
Sandy Loam
10YR3/2
it" -42"
44.0
B
Loamy Sand
10YR4/4
42"-120"
37.5
C
Medium
Coarse Sand
t0YR5 4
DATE OF TESTING< 12/02/21
SOIL EVALUATOR: MARK POLSELI
WITNESS: PHILIP RENAUD YARMOUTH HEALTH
PERCOLATION RATE HOLE #1: <2 MIN/IN 0 63"
NO GROUNDWATER ENCOUNTERED
NO MOTTLWG ENCOUNTERED
v'�tW OF MOSS
r��. ss3a�a
Y
t�H v>,
7;�, r
EL - 47.51
GEOTEXTILE
FABRIC
I
M.5 3/4" to
f -1/Z" STOW
(Double wash
cj
TWO (2) 500 GALLON H-20 PRECAST
CONCRETE LEACH CHAMBERS WITH 4' OF
STONE ON ENDS AND 4' ON SIDES
LEACH CHAMBERS 5.0±
(END VIE
EL=37.5 Bottom Test Hole
�19}-
SYSTEM DESIGN CALCULATIONS
SEWAGE DESIGN FLOW., THREE BEDROOM DWELLING 0 110 GPD/BEDROOM = 330 GPD
(MINIMUM DESIGN REQUIRED 330 GPD)
SEWAGE DESIGN FLOW PROVIDED: TWO (2) 500 GALLON CHAMBERS
NTH 4' STONE ON THE ENDS AND 4' STONE ON THE SIDES
Vt = [(25.0 x 12.83) + 2(25.0 + 12.83) (2) x .74 = 349 GPD PROVIDED
349 GPD PROVIDED > 330 GPD REQUIRED
SEPTIC TANK CAPACITY REQUIRED: 330 GPD X 200 = 660 (MINIMUM)
SEPTIC TANK CAPACITY PROVIDED: 1,500 GALLON SEPTIC TANK (PROPOSED),,..
A GARBAGE DISPOSAL IS NOT PERMITTED WITH THIS DESIGN FLOW r7
Proposed Septic Plan ;
36 Chickadee Lane West Yarmouth, M
Prepared by.
Prepared for; All Cape Septic and Survey
Jhonatan Silva 618 Route 28
West Yarmouth, MA 02673
(508) 771-4200
Date: 12/07/21 allcopesepticogmail.com
Sheet 2 of 2