HomeMy WebLinkAboutEngineer Plans - 2021Permit valid for REPAIK Ur a'r.r••.. •�-
oNLY, due to State and Local septic variances.
Board of Heaftb res iew and approval is required for
any future additions/renovations/aiterations to
sewage facilities and/or structures/dwelling.
Yarmouth Health Department
APPROVED
PROPOSED S.A.S.
2-500 GAL CHAMBERS
Xry i� /i 1 2Ozl SURROUNDED W/4' STONE
Date
EXISTING SEPTIC TANK i1
(TO REMAIN) 5 '14'p5 50 etockode fence �
TOP OF TANK, EL.=99.00t
INV.(OUT)=9765±
/� 00,
���" x
x 100.31
100.80
SHED — — — --�
100,93 FIRE
OPIT
PATIO
101.33
I ioL18
PATIO
EXISTING LEACH PIT
TO BE REMOVED
SEE NOTE 11
9983 U 1
UTILITY POLE
Y� /¢
loo 91 � t"
VENT x
l \ O
N
O a''
I�TP 1 1
a
101 ,,5 \ rt
'jp* O, 10100
`101,62 j `ik
DECK �' F
a
BHA H102.29
f
n
0 5*70 2.27
XISTING � PATIO x 101.76
l[ 44) 3 ELO
USE(#102,24 100
F'.=102.6±
/
;K x 101.73
C5
101.85x LOT 108 �/ '�
Q.'X
._4 13,228±S.F.
x 10063
X 101.40 �
101,42 x
X 100.91
9955 WSU- / t 100.36
5�' E 101.53 Overn6n ,�. '( �I1,
1,x•05 i -� f 10047 P U J/
edge � 1�j
N
100.81 I� V JJ
ADIs°
OWNER OF RECORD 10123
BABETTO, STEPHANIE L
44 MADISON AVENUE
SOUTH YARMOUTH, MA .02664
100.77
10064
I
98 -- EXISTING CONTOUR 1 .•, A 4'r
x 100.98 EXISTING SPOT GRADEL 3:T
r
—W— EXISTING WATER SVC.
— G -- EXISTING GAS SVC."
—$/-/•{— OVERHEAD WIRES'"' rv°
TEST PIT 43.x,
BENCHMARK
LEGEND
x
OCUS
tt14.v FoeP ry' y "�kvv' ��.
W, r
co
rt i� � P imp
LOCUS MAP-
a'
APa GENERAL NOTES:
ro
Y 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
m BOARD OF HEALTH AND THE DESIGN ENGINEER..
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW:
-310 CMR 15.405(1)(b):.LOCAL UPGRADE APPROVAL (if needed)
1) A 3' variance to the 3' maximum cover requirement, for up
to 5' of max. cover. S.A.S. shall be H-20 and vented.
�C���. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
NOVrt DESIGN ENGINEER.
O 0 12021 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
HEALTH DEPT. 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM:
6, THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION,
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
S. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S,
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
F61h5Sgg AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
hGs� DIRECTED BY THE APPROVING AUTHORITIES.
fpm 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
Qµ111.. a THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
N� Og6 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
QF ISS REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
'0 Al. 12, AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
MAP ID: 88-100
9�yG PROPOSED SEPTIC SYSTEM UPGRADE PLAN
PETER T.
44 MADISON
AVENUE, SOUTH YARMOUTH, MA
McENTEE —
Prepared for: Quinn's
Excavating, P.O. Box 599,
Forestdale,
MA 02544
CIVIL
No, 35109
O
GISfE
Engineers:
Engineering Works, Inc.
Surveyors:
JC Engineering, Inc.
SCALE
1 "=20'
DRAWN
P.T.M.
JOB. NO.
249-21
DATE
CHECKED
SHEET NO.
12 West Crossfield Road
Forestdale, MA 02644
2854 Cranberry Hwy.
E.Wareham, MA 02538.
,, f
a I' C.��Z�,
(508) 477-5313
(508) 273-0377
9/2/21.
P.T.M.
1 Of 2
NOTE: TO PREVENT BREAKOUT, FINAL GRADE
SEPTIC TANK SHALL NOT BE AT, OR BELOW, EL.=97.5 _
INSTALL RISERS &COVERS OVER INLET & FOR A DISTANCE OF 15' FROM THE EDGE I,.J,DECK
OF THE PROPOSED S.A.S.
OUTLET AND SET TO 6" OF FINISH GRADE PROPOSED D -BOX
INSTALL RISER & COVER PROPOSED S.A.S. x PA Flo f!' 1 r/
SET TO 6" OF GRADE INSTALL RISER & COVER OVER ONE CHAMBER AND 11�1�1J.18ECOW� / f/ i�f /��/ /
T.O.F=102.6± SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT Ifl'a jr / /r% EX/5 G / r
�l F.G. EL.=101.6± A F.G. EL.=101.01 F.G. EL.=10L.Ot F.G. EL.=101.01 ^^ANT #„ y ���/r /f HOUSE(#44)' %, r
r 44)-
p
I - oI / ! ! �f /T.Q.F.=102.6.±/ r /
EXISTING
48" LIQUID
LEVEL
I GAS
NOTES:
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE
INVERTS, PRIOR TO INSTALLATION.
2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE
ON A MECHANICALLY COMPACTED STABLE BASE OR
SIX INCH AGGREGATE BASE, AS SPECIFIED IN 310
CMR 15.221(2).
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.
DESIGN CRITERIA
L=22'
® S=1% (MIN.)
4"SCH40 PVC
® S=1% (MIN.)
4"SCH40 PVC
2' EFF.
DEPTH
INV.=97.27 PROPOSED INV.=97.10
V.=97.65± D BOX
VERIFY) 3 OUTLETS INV.=97.00-
TOP CONC. ELEV.=98.1 t -
BREAKOUT ELEV.=97.50 -
INV. ELEV.=97.00 -
BOTTOM ELEV.=95.00 -
4' OF NATURALLY OCCURRING
PERVIOUS MATERIAL
5' (MIN.) ABOVE G.W.
BOTTOM OF TEST PIT, EL.=89.9
MAINTAIN 2% SLOPE I I OVER S.A.S.
2" LAYER OF 1/8 TO 1/2"
DOUBLE WASHED STONE
/ EFFECTIVE WIDTH = 12.8' I
SEPTIC SYSTEM PROFILE
NUMBER OF BEDROOMS: 3
SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF)
DESIGN PERCOLATION RATE: <2 MIN/IN
DAILY FLOW: 330 GPD
DESIGN FLOW: 330 GPD
GARBAGE GRINDER: NO -not allowed with design
LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF
.74 GPD/SF
EXISTING SEPTIC TANK: 1500 GALLON CAPACITY
PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED
USE 2-500 GALLON LEACHING CHAMBERS IN SERIES
SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES
SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F.
BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F.
TOTAL AREA: ... ............. ....... ...... ....................... 471.2 S.F.
DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD
DOD = 1 /.
LENGTH =
LEACHING SYSTEM SECTION
SOIL LOG
DATE: SEPTEMBER 1, 2021
SOIL EVALUATOR: PETER McENTEE SE#1542
WITNESS: PHIL RENAUD RS R.S.HEALTH AGENT
ELEV. TP DEPTH
101.4n( j 0"
LOAMY SAND
10YR 4/2
100.7 B 8"
LOAMY SAND
10YR 5/8
98.930"
C 26"/42
PERC
MED. SAND
2.5Y 6/6
89.9 1 138"
PERC RATE <2 MIN/IN. "C" HORIZON
NO GROUNDWATER ENCOUNTERED
TO 1-1/2" DOUBLE
WASHED STONE
C' f f /�a
�_... ,...>
i DECK I
CD
DECK
NNO
ro
---- -- -
PROPOSED S.A.S.
2-500 GAL CHAMBERS
I I
CI
SURROUNDED W/4' STONE
1
I --25'---I
SEPTIC
LAYOUT
11.9mmll,
�i =1 =1 1�1 t�1
�=1
1 f 1=1 I=f =1 I0m1-f 1�I til 1�( 1_=1 Int 1=1 til
500 GALLON CAPACITY, H-20 LOADING
CHAMBERS
N.T.S.
58"
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
44 MADISON AVENUE, SOUTH YARMOUTH, MA
Prepared for: Quinn's Excavating, P.O. Box 599, Forestdale, MA 02644
Engineers: Surveyors: SCALE DRAWN JOB. NO.
Engineering Works, Inc. JCEngineering, Inc. N.T.S. P.T.M. 249-21
12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET N0.
Forestdale, MA 02644 E.Wareham, MA 02538
(508) 477-5313 (508) 273-0377 9/2/21 P.T.M. 2 Of 2
4" KNOCKOUT
20" DIA. COVER
4" KNOCKOUT 04" KNOCKOUT
4" KNOCKOUT
500 GALLON CAPACITY, H-20 LOADING
CHAMBERS
N.T.S.
58"
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
44 MADISON AVENUE, SOUTH YARMOUTH, MA
Prepared for: Quinn's Excavating, P.O. Box 599, Forestdale, MA 02644
Engineers: Surveyors: SCALE DRAWN JOB. NO.
Engineering Works, Inc. JCEngineering, Inc. N.T.S. P.T.M. 249-21
12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET N0.
Forestdale, MA 02644 E.Wareham, MA 02538
(508) 477-5313 (508) 273-0377 9/2/21 P.T.M. 2 Of 2