HomeMy WebLinkAboutEngineer Plans - 2019FRONT YARD
30'
SIDE YARD
20'
REAR YARD
20'
LOT COVERAGE
25%
N
N/F
ARDEN
�R y PA/V
q �c�ST Ty E �/Tcy
0CT08
ER 2015
BENCH MARK --TOP & CENTER OF
CONIC, BOUND=11.51 NAVD88
N/F
ARDEN
LEGEND
" 1 TEST HOLE LOCATION, NUMBER
-W- WATER LINE MARKINGS
---E- OVERHEAD ELECTRIC WIRES (IF SHOWN)
9.5 x 8,7 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT)
EXISTING CONTOUR
-8- PROPOSED CONTOUR
0 UTILITY POLE (IF SHOWN)
® EXISTING DRAINAGE CATCH BASIN
- FENCE (IF SHOWN, NOT ALL SHOWN)
REV. 12/29/20 --FENCE & LIGHT POLE ADDED
REV. 11/04/20 --WORK LIMIT & SWALE
REV. 10/29/20 --GARDEN & LANDSCAPING ADDED
REV. 10/14/20 --BUYER, HOUSE, WETLAND LINE, GRADES
N/F
SNOWDEN
5
SOT 1 B
UPLAND- 40,025tS. F.
WETLAND=15,380±S.F.
TOTAL AREA=55,405tS. F.
ABANDONED BOG 4
,A�
0.1
i
Proposed
14'8
0
0
Proposed
5.4' 5'
TESTDOLE DATE:
Feb. 11, 2016 & March 27, 2019
12"
JOB NO. Y20-13
PERFORMED BY:
Ron Cadillac, Soil Evaluator
4/2
NOTES
McCarthy2.dwg
WITNESSED BY:
Amy Von Hone & Philip Renaud
layer 2.5y
1.
LOCUS IS A.M. 132, PARCEL 74.3. 1
FB 34/23 SB 14/5+56
<2'-00"/inch (C2 layer--TH 2)
observed water
22.0
2.
ELEVATIONS SHOWN ARE NAVD88 BASED UPON RM4 & VERTCON.
Eastchop loamy sand
24"
und.
SDW252 Zone A
3.
LOCUS IS IN FLOOD ZONES AE(EL 12); AND HOUSE IS X(OUTSIDE 0,2% RISK) ON FIRM DATED JULY 16, 2014,
PROPOSED TOP FOUNDATION IS 2' ABOVE
HIGH POINT IN ROAD
4.
ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED)
zLOCUS
AVERAGE NATURAL GRADE AT STREET SIDE
OF FOUNDATION=18.0
2--500 GALLON DRY WELLS
5.
MUNICIPAL WATER IS AVAILABLE. LOTS
WITHIN 100' ARE ON TOWN WATER.
cr
H-20
330 GPD
teptic
6.
COMPONENTS TO BE AASHTO H-10, ONLESS
NOTED.
h.
MAXIMUMI BUILDING HEIGHT= 18 +
35 =53
Proposed Top Conc.=17.8
7.
INLET TEE TO PROJECT DOWN 13", OUTLET
TEE DOWN 14".
A 13' x 25'
Top Peastone/Filter Cloth
BOTTOM: 25' X 13'=325 SF
8.
IF TWO OR MORE LINES, WATER TESTiD-BOX FOR EQUAL FLOW
ROTE
SIDE: (25' + 13')2 X 2'=152 SF
70
1500 Gal.
D -BOX EXIT PIPES TO BE LEVEL FOR'FIRST TWO FEET.
6
128"
353 PD
9.
DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED.
NOT TO
N S
COVERS: BUILD UP COVERS TO 6" BELOW GRADE -2 ON TANK, 1 ON D -BOX, 1 ON LEACHING
SCALE
• a38
10.
STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1 8 TO 1 2" PEA STONE ON TOP. / / /
LOCATION MAP
11.
IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND,
9s' ±
CONTACT THE BOARD OF HEALTH, OR R.J, CADILLAC.
12,
IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING
IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3).
TEST HOLE 1
13,
PUMP AND FILL ANY EXISTING CESSPOOLS. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN
LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT.
DEPTH (inches) ELEV.(feet)
14
ALL CONSTRUCTION TO MEET TITLE SAND LOCAL REGULATIONS
1 o4pR �Jei�� �
I151
wETLA
UPLAND ,�;,.m,
i� OR
�o 4/4#',
04� MIXED HYDRANGEA, HOSTA, PERENNIALS a. �` X11% j
`)00 r it /' LAWN
�8 x 137
J tea' NP�M\P� o?h2d1 SWA 12
~.
�'. 12.2 �,
"-- -
a WA �m
2'
P RENNIALS
s 1-7 • 13: �- - _y �,S'� ° ���'i - ROC / ,HOSTA, PERENNIALS
1 1071 LAWN 16 x 15,a-- I & ROCK GARDEN PLANTS
-- - I I / /
15.--"1 i g4 _7 2- _ a �� Pro ROP.
8 r 1 - i BLOCK x 1�.9 / / --PROVIDE SWALE 4' OFF
P• r 14j4 PATIO 1 / OT LINE TO KEEP
RUN DOWNSPOUTS + 179 ;.. • • ' " Deck " U
I LAWN /
TO PROP. DRY WELL �� q•; 225ts.t. Innn j ' N OFF ON PROPERTY
USE 4' DEEP PIT / 1 10- T - /
W/2' OF STONE ( TO PR
PLACE IN SAND `�� '- + <<,.i ��// � � 1s`'"' `•' /
BELOW SILTY CLAY / 10 PROPOSED + t RUN DOWNSPOUTS
`(( .• 3 BEDROOM DWELLING �;., 10 OP. DRY WELL
GARAGE +,., ( li - - -USE 4' DEEP PIT
1890±SF (Shaded) W/2' OF STONE
....... , // / PLACE, IN SAND
BENCH MARK --TOP OF SPIKE SET 1g
DOWN 1"-19.36 NAVD88 :, ..L 65tsA // ELOW SILTY CLAY
(NEAR WELL PIPE) 70v s., . ....3a •.• zj% 1 OFF LOT
u a REVEGET tE WITH PERENNIALS
LA �7' AND GROUND
COVERS TO 6'
l x 20.9
23"Maple
BENCH MARK --TOP & CENTER 10 2
CONC. BOUND=20.30 NAVD88
x 21.
3
x 21.3
C
�o = 17,R
19x3 •::•'.•' 19x2 /
I ,c
=149.38' r NYi�Sr 32.72'
A= 60.47'
Fenqe Light oe '6• S� 0"'W `
20 +. j 9
1 V)�
0.7Q.1i
t x 18,7
----�.
�E
�E 'T�T�4
HIGH POINT IN ROAD=20,0
N/F
SNOWDEN
I
I
FRONT PORCH MUST
BE ON PIERS
'_ PROVIDE SWALE TO
KEEP RUNOFF ON
PROPERTY,,
FOUNDATION DESIGN
BY OTHERS
14.5
silty clay loom r,
11.8-Sa----ndTH--- 1- 4
- _ 2A11
N/F
SNOWDEN
A layer 10yr 3/3
loam
B layer 10yr 4/4
loam
C1 layer 10yr 4/2
silty clay loam
C2 layer 2.5y 6/3
medium sand
observed water
16.8
15.8
8.8
18.3
24"TEST HOLE 2
Invert 16.80 1- DEPTH (inches) ELEV.(feet)
Invert 17.21
6"
Proposed
14'8
0
0
Proposed
5.4' 5'
TESTDOLE DATE:
Feb. 11, 2016 & March 27, 2019
12"
loam
PERFORMED BY:
Ron Cadillac, Soil Evaluator
4/2
r- 1 2- i High GW=9.8
WITNESSED BY:
Amy Von Hone & Philip Renaud
layer 2.5y
HGW=9.4
PERC RATE:
<2'-00"/inch (C2 layer--TH 2)
observed water
22.0
1' USGS Adjust.
February 2016
SOIL SURVEY(1993):
Eastchop loamy sand
24"
und.
SDW252 Zone A
GEOLOGIC MAP(1986):
Harwich outwash plain deposits
TH 3=8.9 Test
Hole 1=8.8
BEDROOMS:
3
92
Invert 17.45
2--500 GALLON DRY WELLS
60"
LEACH AREA
Use Gas Baffle
H-20
330 GPD
teptic
H-10
!Proposed
Invert 17.04
1500 PAL,
/ft
9" min. Cover
Proposed Top Conc.=17.8
96
477 SIT
4' OF STONE ALL AROUND, TO MAKE
A 13' x 25'
Top Peastone/Filter Cloth
BOTTOM: 25' X 13'=325 SF
Proposed
S_'1 /4"/ft
S=1 /4"/ft -17r / s" Max.
SIDE: (25' + 13')2 X 2'=152 SF
70
1500 Gal.
"'d
128"
353 PD
Septic Tank
_ _
„
A layer 10yr 3/3
loam
B layer 10yr 4/4
loam
C1 layer 10yr 4/2
silty clay loam
C2 layer 2.5y 6/3
medium sand
observed water
16.8
15.8
8.8
18.3
24"TEST HOLE 2
Invert 16.80 1- DEPTH (inches) ELEV.(feet)
Invert 17.21
6"
Proposed
14'8
0
Stone or compact
Proposed
5.4' 5'
layer 10yr
4/4
loam
Bottom
12"
4/2
r- 1 2- i High GW=9.8
C2
layer 2.5y
HGW=9.4
medium sand
observed water
N 0.5' USGS Adjust.
1' USGS Adjust.
February 2016
DESIGN DATA
< March 2019
(D AlW 247 Zone A
SDW252 Zone A
34"
TH 3=8.9 Test
Hole 1=8.8
BEDROOMS:
3
GARBAGE GRINDER:
No
LEACH AREA
60"
REQUIRED CAPACITY:
330 GPD
PROPOSED SEPTIC TANK:
1500 PAL,
USE TWO 500 GALLON DRY WELLS WITH
APPROX.
140)
LEACHING AREA:
477 SIT
4' OF STONE ALL AROUND, TO MAKE
A 13' x 25'
78
BOTTOM: 25' X 13'=325 SF
BY 2' DEEP LEACH AREA.
122„
SIDE: (25' + 13')2 X 2'=152 SF
DESIGN CAPACITY:
353 PD
5' REMOVAL
„
[(477 SF) X .74 GPD/SF] 128
CALL RJ CADILLAC FOR INSPECTION OF SEPTIC
SYSTEM WHILE COVID19 RULES APPLY.
RUNOFF NOT TO BE INCREASED TO ADJACENT
PROPERTIES, ROADWAY, OR WETLAND.
THIS PLAN IS A VALID COPY ONLY IF IT BEARS
AN ORIGI ED STAMP D SIGNATURE.
RONALD
JAMES
CADILLAC
# 1060
RONALD
JAMES
CADILLAC
,# 35779
HEALTH AGENT APPROVAL DATE
A
layer 10yr
3/3
loam
B
layer 10yr
4/4
loam
C1
layer 10yr
4/2
loam
C2
layer 2.5y
6/3
medium sand
observed water
19.0
18.0
16.2
14.0
8.8
83
DO 5 ALL AROUND AND UNDER REMOVAL 78
DOWN 5' TO 8 1/2' TO MEDIUM SAND. TEST HOLE 3
DEPTH (inches) ELEV.(feet)
0
10"
32"
100"
134"
Yarmouth Health Department
OVED za--M148"
Name bate
A
layer 10yr
3/4
loam
B
layer 10yr
5/8
loam
C1
layer 10yr
5/4
silty clay
C2
layer 10ry
6/6
medium sand
observed water
SITE PLAN
FOR
PAUL J. & LINDA R. MCCARTHY
LOT 1131 65 WINTER STREET, YARMOUTHPORT, MA
MAY 24, 2019 SCALE: 1 "=20'
RONALD J. CADILLAC, PLS, RS
PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN
P.O. BOX 258
WEST YARMOUTH, MA 02673
(508) 775-9700
C)2020 BY R.J. CADILLAC
PAGE 1 OF 1