Loading...
HomeMy WebLinkAboutEngineer Plan - 202112.0' SYSTEM PROFILE 2' CAST IRON COVERS TO GRADE OR CONCRETE (NOT TO SCALE) COVERS TO WITHIN 6" GRADE, COORDINATE W/ OWNER OF COVER OVER PRECAST 4"4SCH40 PVC PIPES LEVEL 1ST 2' U10 - **EXISTING 14" r�.w TEE SEPTIC TANK TEE *8.56'f 000gaaoo°oa WATERTEST D'BOX GAS BAFFLE::, FOR LEVELNESS 4' DQ. LEVEL (ACME OR EQUAL)'' 8.41' 8.24' oso�o�o�oe�oe00000" " " �_"_"_�o,0000 ` 6" CRUSHED STONE OR MECHANICAL L� COMPACTION. (15.221 [21) ( % SLOPE) (-L-% SLOPE) H-20 FOUNDATION- EXIST. - SEPTIC TANK 15' D' BOX 7' - *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEN D -- 99- EXISTING CONTOUR X 88.1 EXIST. SPOT ELEV. -[991-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYM60L5 MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: PHIL RENAUD DATE: 7/8/21 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 0„ 4 10YR 3/11 12' r//SL j/ �IkIOYR 5/4 16' ///// ;, / / 2.5Y 6/4 36" ///// C2 PERC M/CS 2.5Y 7/3 ELEV. 10.0' 7.0' mue; **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE UNSUITABLE SOIL G -W ADJ. DATA: WELL: MW 29 ZONE: A ADJ: 2.1' (JULY 2021) MARK CORNERS OF LEACHING FIELD W/ REBAR SET 4" BELOW GRADE 2% SLOPE INSPECTION PORT H-20 FILTER FABRIC / TOP8.52' FINISHED GRADE • - LEACHING FACILITY 1 CLEAN FILL 4' PERFORATED PVC 2.5' D.C. S=0.005 0 0 3/4"-1-1/2" DOUBLE WASHED 0 8" STONE LEACHING FIELD LEVEL BOTTOM 0 30.0' 7.54' ADJ. G.W. EL= 3.1 PROP. VENT WITH AND BUGSCREEN CONTRACTOR WTI CONSULTATION) DAL FILTER PLACEMENT BY NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-211 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED. 13. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. OF UNSUITABLE SOIL REQUIttD ETER OF LEACHING FACILIi, T LE SOIL LAYER. REPLACE -ti ME . SAND, TO MEET JS OF 310 CMR 15.255(3) t0_-20.11 LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 33 PARCEL 52 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO589J DATED 7/16/2014 DEC 0 2 2021 HEALTH DEPT SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED - - DESIGN FLOW: 2 BEDROOMS 0 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 **RE -USE EXISTING 1000 GAL. H-20 SEPTIC TANK LEACHING: 220 GPD (.74) = 298 SF REQUIRED 10'X30'=300 SF OK 300 SF X .74 = 222 GPD OK USE A 10' X 30' PIPE AND STONE LEACHING FIELD MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN Ar of Ayx OF sq� D,4AIEL 5�m SHOFMqssg0 9 BLISCOTT AVE OJALA �, o� DANIELA NO. 40980 DJAIA CIVIL Nm� OUTH YARMOUTH, MA r No. 46502 pSURV P CrSTE' ° �� PREPARED FOR STT ���ta� DANIEL A. OJAL4 No.409S0 OJALA CIVIL No. 46502 �6r.�TERi 120„ u 0_0' GW ENCOUNTERED AT 108" EL. = 1.0' _ 1 LICE #2'-223 0 10 20 30 40 50 FEET DATE DANIEL A. OJALA, P.E., P.L.S. EA W MARIA GUNUAL V CS DATE: AUGUST 25, 2021 REV. OCTOBER 20, 2021 (HEALTH DEPT. COMMENTS) I off 508-362-4541 fax 508-362-9880 downcape.com down cape engineering, inC. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 21-223 GONCALVES.DWG e o 4� ne s� of g pJI to 5 Cocus N S. S �N N � pkh A m P a 4 a m LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 33 PARCEL 52 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO589J DATED 7/16/2014 DEC 0 2 2021 HEALTH DEPT SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED - - DESIGN FLOW: 2 BEDROOMS 0 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 **RE -USE EXISTING 1000 GAL. H-20 SEPTIC TANK LEACHING: 220 GPD (.74) = 298 SF REQUIRED 10'X30'=300 SF OK 300 SF X .74 = 222 GPD OK USE A 10' X 30' PIPE AND STONE LEACHING FIELD MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN Ar of Ayx OF sq� D,4AIEL 5�m SHOFMqssg0 9 BLISCOTT AVE OJALA �, o� DANIELA NO. 40980 DJAIA CIVIL Nm� OUTH YARMOUTH, MA r No. 46502 pSURV P CrSTE' ° �� PREPARED FOR STT ���ta� DANIEL A. OJAL4 No.409S0 OJALA CIVIL No. 46502 �6r.�TERi 120„ u 0_0' GW ENCOUNTERED AT 108" EL. = 1.0' _ 1 LICE #2'-223 0 10 20 30 40 50 FEET DATE DANIEL A. OJALA, P.E., P.L.S. EA W MARIA GUNUAL V CS DATE: AUGUST 25, 2021 REV. OCTOBER 20, 2021 (HEALTH DEPT. COMMENTS) I off 508-362-4541 fax 508-362-9880 downcape.com down cape engineering, inC. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 21-223 GONCALVES.DWG