Loading...
HomeMy WebLinkAboutEngineer As-Built - 2022F.F.E.= 45.5± EXISTING SEP77C TANK (TO BE PUMPED, RUPTURED & FILLED WITH CLEAN SAND IN ACCORDANCE OATH MA 310 CMR 15.354) EXISTING LEACHING PIT (TO BE ABANDONED IN ACCORDANCE NTH MA 310 CMR 15.0354) 0 .a V tV N � 1,500 GALLON SEPTIC TANK PROPOSED 5 OVEDIG (SEE EXCAVATION NOTE) 33 KAYCEES WAY MAP 66 PARCEL 8 (TOWN WATER) I N' O EXISTING GRAVEL CIP OVERHEAD YWRES v/ APPROX EX. WATER SERVICE '413 EXIS77ry'G HOUSE -T OP?�@ (3) BQDROOMS F.F.E. _ 45.5t �I y T.O.F. �� 45.Oi _22!1 I it't (rj EX. \ WALL EXISTING (TYPO {Z STONE WALL 3 -TP �� BENCHMARK: CSS/INSPECITON PORr ELEV. = 41.64 (NAVD88) TOP OF CONCRETE BOUND OS63-(3) BEDROOM SOL ABSORPTION SYSTEM p (10' x 30') 403 W YARMOUTH ROAD MAP 66 PARCEL 2 (TOWN WATER) 10' MIN OXTI GRADE INV.= 42.2±"l ° CONTRACTOR TO CONFIRM INV.= 38.; EXISTING ELEVATION OF SEWER PRIOR TO START OF CONSTRUCTION. 6" COMPACTED STONE BASE ON COMPACTED NOTES SUBGRADE (TYP.) (1) ALL SYSTEM COMPONENTS TO BE MARKED WITH MAGNETIC MARKING TAPE. (2) ALL FINISHED SYSTEM COMPONENTS TO BE WITHIN 36" OF (3) BELINSTALLED BY AWITHIN LICENSED PLUMBER. THE ER FOUNDATION TO 5'VA"t.," 20' MIN. 24" DIA. RISER, TO WITHIN 6" OF GRADE (TYP.) F.G. = 42.4E 12 MIN. RISE 36" MAX. �10" MIN. f A100 ZABEL FILTER 4' MIN. W/SUPPORT LEG I (SEE MANF. {NST. ) PROPOSED 1500 GALLON PRE -CAST SEPTIC TANK (H-10 LOADING) TANK TO BE EMBOSSED WITH ASTM STANDARD C 1227-93 SEAL 24" DIA. {,SECURABLE ACCESSOVER TO GRADE. EMBOSSED "ZABEL". m '40" E 4 146.13' EXISTING LEACHING PIT ABE ABANDONED IN CCO DANCE WIN MA 310 CMR 15.0354) ///---D-BOX RISER J REQUIRED I (12" MAX. DEPTH) F.G.= 41.3± FIRST 2' SET LEVEL 4" SCH. 40 PROPOSED DISTRIBUTION BOX PRE -CAST WATERTIGHT (H-20 LOADINGS 12" MIN. INSIDE DIM. 6" MIN. SUMP 12" MAX. DEPTH SYSTEM PROFILE NOT TO SCALE MASS COORDINATE SYSTEM z 0: o m 0. 20" 12" MIN. C MAINLAND ZONE MERIDIAN 36" MAX. 1 3 7- .'L DETERMINED USING A TOP = 38.50 - � TOPCON HIPER GPS RTK UNIT 3 �{ ® o ® ® ® ° 0 0 WASHED STONE COLLECTION DATE 05/26/2020 pe•°e°O°600 °pao°e c' 3 W E ®®O C® I - I 4 4211 WEST YARMOUTH ROAD 10' 32;. 7 MAP 66 PARCEL 4 -3- H 'I (3) - 500 GALLON CONCRETE (TOWN WATER) LEACHING CHAMBERS (4.8'W x 8.51 x 24" INVERT) v i U 10.0' WIDE x 30.0' LONG x 2' DEEP S 85°12'48' W FENCE (H-20 LOAD RATED) _11 ESTIMATED HIGH G.W.: i 0.00' EXISTING STOCKADE CB/OH FND ! S MAP66 23 KAYCEES WAY PARCEL MAP 66 PARCEL 7 (TOWN WATER) j .J� 25095 S.F..± F.F.E.= 45.5± EXISTING SEP77C TANK (TO BE PUMPED, RUPTURED & FILLED WITH CLEAN SAND IN ACCORDANCE OATH MA 310 CMR 15.354) EXISTING LEACHING PIT (TO BE ABANDONED IN ACCORDANCE NTH MA 310 CMR 15.0354) 0 .a V tV N � 1,500 GALLON SEPTIC TANK PROPOSED 5 OVEDIG (SEE EXCAVATION NOTE) 33 KAYCEES WAY MAP 66 PARCEL 8 (TOWN WATER) I N' O EXISTING GRAVEL CIP OVERHEAD YWRES v/ APPROX EX. WATER SERVICE '413 EXIS77ry'G HOUSE -T OP?�@ (3) BQDROOMS F.F.E. _ 45.5t �I y T.O.F. �� 45.Oi _22!1 I it't (rj EX. \ WALL EXISTING (TYPO {Z STONE WALL 3 -TP �� BENCHMARK: CSS/INSPECITON PORr ELEV. = 41.64 (NAVD88) TOP OF CONCRETE BOUND OS63-(3) BEDROOM SOL ABSORPTION SYSTEM p (10' x 30') 403 W YARMOUTH ROAD MAP 66 PARCEL 2 (TOWN WATER) 10' MIN OXTI GRADE INV.= 42.2±"l ° CONTRACTOR TO CONFIRM INV.= 38.; EXISTING ELEVATION OF SEWER PRIOR TO START OF CONSTRUCTION. 6" COMPACTED STONE BASE ON COMPACTED NOTES SUBGRADE (TYP.) (1) ALL SYSTEM COMPONENTS TO BE MARKED WITH MAGNETIC MARKING TAPE. (2) ALL FINISHED SYSTEM COMPONENTS TO BE WITHIN 36" OF (3) BELINSTALLED BY AWITHIN LICENSED PLUMBER. THE ER FOUNDATION TO 5'VA"t.," 20' MIN. 24" DIA. RISER, TO WITHIN 6" OF GRADE (TYP.) F.G. = 42.4E 12 MIN. RISE 36" MAX. �10" MIN. f A100 ZABEL FILTER 4' MIN. W/SUPPORT LEG I (SEE MANF. {NST. ) PROPOSED 1500 GALLON PRE -CAST SEPTIC TANK (H-10 LOADING) TANK TO BE EMBOSSED WITH ASTM STANDARD C 1227-93 SEAL 24" DIA. {,SECURABLE ACCESSOVER TO GRADE. EMBOSSED "ZABEL". m '40" E 4 146.13' EXISTING LEACHING PIT ABE ABANDONED IN CCO DANCE WIN MA 310 CMR 15.0354) ///---D-BOX RISER J REQUIRED I (12" MAX. DEPTH) F.G.= 41.3± FIRST 2' SET LEVEL 4" SCH. 40 PROPOSED DISTRIBUTION BOX PRE -CAST WATERTIGHT (H-20 LOADINGS 12" MIN. INSIDE DIM. 6" MIN. SUMP 12" MAX. DEPTH SYSTEM PROFILE NOT TO SCALE m EN N. 0 CB/DH FND PLAN SCALE 0 4 8 12 16 20 30 40 60 1 inch = 20 feet INSPECTION/ACCESS MANHOLE TO WITHIN 3" OF FINISHED GRADE MIN. 2% SLOPE VENT CHAMBERS OVER S.A.S. WITH CHARCOAL FILTER 10' MIN. F.G.= 41.51to 39.5: No z 0: o m 0. 20" 12" MIN. C D 36" MAX. 1 3 7- .'L FILTER FABRIC RISER TOP = 38.50 - � v 3 �{ ® o ® ® ® ° 0 0 m EN N. 0 CB/DH FND PLAN SCALE 0 4 8 12 16 20 30 40 60 1 inch = 20 feet INSPECTION/ACCESS MANHOLE TO WITHIN 3" OF FINISHED GRADE MIN. 2% SLOPE VENT CHAMBERS OVER S.A.S. WITH CHARCOAL FILTER 10' MIN. F.G.= 41.51to 39.5: No z 0: o m 0. 20" 12" MIN. C D 36" MAX. 1 3 7- .'L FILTER FABRIC RISER TOP = 38.50 - 0C3 U CS 0 3/4" TO 1 1/2" DOUBLE 3 �{ ® o ® ® ® ° 0 0 WASHED STONE - pe•°e°O°600 °pao°e c' 3 - ®®O C® Bor.= 35.40 - I 4 - 10' 32;. 7 PROPOSED SOIL ABSORPTION SYSTEM -3- - (3) - 500 GALLON CONCRETE _ 5' MIN. LEACHING CHAMBERS (4.8'W x 8.51 x 24" INVERT) TOTAL EFFECTIVE LEACHING AREA: 10.0' WIDE x 30.0' LONG x 2' DEEP (H-20 LOAD RATED) _11 ESTIMATED HIGH G.W.: 30,4: AS -BUILT SEPTIC SYSTEM "TIES" No A B C D DESCRIPTION 1 3 7- .'L 22i, ° - - SEPTIC TANK INLET LID 2 3 �{ 3, 1 ' - - SEPTIC TANK OUTLET LID 3 - /A3 ' 3 �(, v ° - DISTRIBUTION BOX 4 - Z 4. S' 32;. 7 ACCESS/INSPECTION PORT -3- - - - SOIL LOGS TP NO. 1 TP NO. 2 GRD. EL. 40.5 GRD. EL. 40.1 GW. EL. 30.4 GW. EL. 30.0 M " 0 A O/E 40.5 0 LOAMY SAND 2.5Y 4/1 0 7" 39.9 7" BW a LOAMY SAND a IOYR 4/6 34" 7 34" - C MEDIUM SAND IOYR 5/6 ESTIMATED 30.4 HIOi G.W. 132" 295 132" A/O/E LOAMY SAND 2.5Y 4/1 ~ 0 Bw I IL LOAMY SAND 10YR 4/6 C MEDIUM SAND IOYR 5/6 ESTIMATED HIGH G.W. 40.1 39.5 37.3 30.0 NO MOTTLES NO MOTTLES 291 NO WATER NO WATER DATE PERFORMED: MAY 6, 2020 SOIL EVALUATOR: ROBERT E. DEWAR. E.I.T. WITNESSED BY: MALLORY LANGLER - ASS, DIR. of HEALTH PERC. RATE: <2 MINUTES/INCH SOIL CLASS: CLASS I MAX. GROUND WATER ELEV.: 30.4 (SEE BELOW) METHOD OF DETERMINATION: CAPE COD COMMISSION METHOD INDEX WELL: MIW-29 WATER -LEVEL RANGE ZONE: B CURRENT DEPTH TO LEVEL: 6,57 MONTH/YEAR: 04/2020 POTENTIAL WATER LEVEL RISE: 0.9 ESTIMATED DEPTH TO HIGH GROUNDWATER: 11.0 - 0.9 = 10.1 EXCAVATION NOTE THIS SYSTEM REQUIRES THE EXCAVATION OF ALL SPOILED SOIL WITHIN 5' OF THE SOIL ABSORPTION SYSTEM. SOIL SHALL BE EXCAVATED TO THE EXISTING SAND LAYER. ENGINEER TO CONFIRM SOIL DEPTH PRIOR TO INSTALLATION. THE EXCAVATION SHALL BE INSPECTED BY THE DESIGN ENGINEER PRIOR TO BACKFILLING. SOIL IS TO BE REPLACED WITH SAND CONFORMING TO 310 CMR SECTION 15.255, CONSTRUCTION IN FILL. CONTRACTOR IS RESPONSIBLE TO PROVIDE ENGINEER WITH SAND SAMPLE FOR SIEVE ANALYSIS, DESIGN CALCULATIONS SOIL TEXTURAL CLASS: CLASS I PERC. RATE: < 2 MINUTES/INCH NO. OF BEDROOMS: 3 (PER BOH RECORDS) DESIGN FLOW REQUIRED: 330 GPD (MIN.) SEPTIC TANK REQUIRED: 1500 GALLONS SEPTIC TANK PROVIDED: 1500 GALLONS LEACHING SYSTEM: (3) 500 GAL CONCRETE LEACHING CHAMBERS IN A (10') WIDE x (30') LONG x (2') DEEP STONE BED EFFECTIVE LEACHING: 10' WIDE x QL LONG x 2' DEEP BOTTOM AREA= 300 S.F. SIDEWALL AREA= 160 S.F. TOTAL= 460 S.F. LOADING RATE = 0.74 GPD/SF FLOW PROVIDED: 340 GPD > 330 GPD AS -BUILT CERTIFICATION TO THE TOWN OF YARMOUTH: "I CERTIFY THAT THE SEPTIC SYSTEM HAS BEEN CONSTRUCTED IN ACCORDANCE WITH THE TERMS OF THE PERMIT AND THE APPROVED DESIGN PLAN AND MEETS THE REQUIREMENTS OF THE TOWN AND STATE REGULATIONS, AS -BUILT". .a- cnj, H r, -� ZACHARY L. BASINSKI, P.E. INSTALLER SCHEMATIC FLOOR PLANS (EXISTING) BASEMEN T SECOND FLOOR I LOCUS Map Scale: 1" = 500' JiLLS PATH y .y b x: a WAY; p �* D A m N1 D 0 N KAYCEES i W E YARMOUTH. UMIT OF WATER ZONE lI SUPPLY LAND S Notes 1. BENCHMARK: ELEVATION = 41.64 VD88) TOP OF CONCRETE BOUND 2. ALL CONSTRUCTION METHODS AND MATERIALS TO CONFORM TO TITLE V AND THE TOWN OF YARMOUTH BOARD OF HEALTH REGULATIONS. 3. ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. 4. NO FIELD MODIFICATION TO THE SYSTEM SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE DESIGN ENGINEER AND BOARD OF HEALTH, 5. ALL JOINTS AND COVERS TO BE WATERTIGHT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION OF ANY EXISTING UTILITIES. 7. A CERTIFICATE OF COMPLIANCE MUST BE OBTAINED PRIOR TO BACKFILLING SYSTEM. 8. OWNER/APPLICANT: DUFF 2017 DECLARATION OF TRUST STEPHEN A. DUFF, Trustee 1586 HYANNIS ROAD BARNSTABLE, MA 02630 10. DEED REFERENCE: Deed Cert: #220969 11. PLAN REFERENCE: L.C. Plan: #37609-A (LOT 9) 12, THE DESIGN IS INTENDED TO MEET TITLE V AND OTHER APPLICABLE REQUIREMENTS, THIS PLAN DOES NOT GUARANTEE THAT THE SYSTEM WILL BE INSTALLED AS DESIGNED, NOR DOES THIS PLAN GUARANTEE THE OPERATION OF THE SYSTEM. 13. THIS SYSTEM IS NOT DESIGNED NOR INTENDED FOR USE WITH A GARBAGE GRINDER. 15. LOCUS PARTIALLY FALLS WITHIN A ZONE 11 WELLHEAD PROTECTION AREA. 16. LOCUS FALLS WITHIN THE THE YARMOUTH AQUIFER PROTECTION DISTRICT. 17. LOCUS DOES NOT FALL WITHIN AN NHESP ESTIMATED HABITAT OF RARE WILDLIFE OR PRIORITY HABITAT OF RARE SPECIES. 18. LOCUS DOES NOT FALL WITHIN A SPECIAL FLOOD HAZARD ZONES AS SHOWN ON FEMA FLOOD ZONE MAP No: 25001C -0586-J dated 07/16/2014. 19. SOIL CONDITIONS ENCOUNTERED DURING EXCAVATION MAY DIFFER FROM THE PREVIOUSLY OBSERVED CONDITIONS AT THE TEST PITS. ADDITIONAL REMOVAL AND REPLACEMENT OF SOIL MAY BE REQUIRED. IF UNDESIRABLE CONDITIONS ARE ENCOUNTERED, THE DESIGN ENGINEER SHALL BE CONSULTED. 20. NO KNOWN WELLS WITHIN 100' OF THE PROPOSED SOIL ABSORPTION SYSTEM. JAN 0 3 2022 HEATH DEPT. Prepared By: e Mir CAL IN Z I 49 HERRING POND ROAD 19 OLD SOUTH ROAD BUZZARDS BAY, MA 02532 NANTUCKET, MA 02684 (tel) 608.833.0070 (tel) 608.326.0044 (fax) 608.833.2282 www.brackenong.com AS - Jl L_j SEPTIC UPGRADE PLAN IN YARMOUTH, MASSACHUSETTS Prepared For: DUFF 2017 DECLARATION OF TRUST #413 WEST YARMOUTH ROAD MAP 66 PARCEL 3 No.', Date Revision Description By Date: JW(YVST" IZ1 Z d Drown: Checked: Sheet: -.UNE-T6; 294@ RED/BEI ZLB/AMG 1 of 1