HomeMy WebLinkAboutEngineer Plans - 2020*1 3.3±' MIN. 18.2' � ACCESS COVER AT FIN. GRADE MINIMUM 1' OF OVER POLY TAN PROPOSED 1,500 GALLON POLYETHYLENE SEPTIC TANK ✓ GAS (H-10) BAFFLE °°oo°°°°°°°o WATERTEST D'SOX °°�° �° FOR LEVELNESS 12. 12.37' MEC 6" CRUSHED STONE OR MECHANICAL 2" MIN. WALL DEPTH OF FLOW = 4" - COMPACTION. (75.221 (2]) NOTE: THICKNESS REQUIRED REQUIRED TEE SIZES: INLET DEPTH = 10" MIN. BELOW FLOW LINE OUTLET DEPTH = 14" MIN. BELOW THE FLOW LINE NOTE: STANDARD TEES ARE TO BE USED. DO NOT USE MANUFACTURER'S TEES THAT COME WITH THE TANK ( .5X SLOPE) (2,5-% SLOPE) W. FOUNDATION— 13' SEPTIC TANK 7' SYSTEM PROFILE — (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVER TO WITHIN 6" OF FIN. GRADE /nu MINIMUM.75' OF COVER OVER PRECAST 4"4SCH40 PVC PIPES LEVEL 1ST 2' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- EGEND99-- 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. --1991-- PROPOSED CONTOUR 198.4] PROPOSED SPOT EL. TH1 SIDE SETBACK Roufe TEST HOLE 2� SLOPE OF GROUND MAX. UTILITY POLE �e FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: MALLORY LA LER DATE: 10/26/20 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0" 16.2' A LS 6" 1OYR 4/1 B LS 1OYR 5/8 30' 13.7' C PERC MS 2.5Y 7/4 120" I 16.2' NO GROUNDWATER ENCOUNTERED DCE ¢#20-217 Scale:1 "= 20' 0 10 20 30 40 50 FEET (-Z-_5% SLOPE) 91 MARE. CORNERS OF LEACHING FIELD W/ / REBAR SET 4" BELOW PROVIDE INSPECTION PORTS TO V/ GRADE WITHIN 3" OF FINISH GRADE 2% SLOPE FILTER FABRIC SEE PAVEMENT SECTION TOP .12.5' FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ. CLEAN FILL 18" STONEILEACHING FDOUBLD WASHED r0 i LEVEL BOTTOM I o 22.0' 11.56' 6.2' BOTTOM TH-1 NO GROUNDWATER FOUND - 6"DEPTHI MIN BELOW INV. 12.06' LEACHING LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 22 PARCEL 367 LOCUS IS WITHIN FEMA FLOOD ZONE X NOTES (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO588J 1. DATUM IS NANNNN 8 DATED 7/16/2014 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT 4. DESIGN LOADING FOR ALL PROPOSED PRECAST -UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO .SCM. 40-4" PVC, 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROMBOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING; FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED. Yarmouth Health DMarpnent OVER V � S 21 Name Date w „W. ,-,0ofA„-,- UP.NIELA. ojALA CIVIL NO 46502 DANIEL A. OJALA CIVIL No.46502 &TE% ZONING SUMMARY ZONING DISTRICT: R-25 DISTRICT MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. 0 a 30' Z SIDE SETBACK Roufe MIN. e�. 20' MAX. BUILDING COVERAGE �e MAX. e sf 35' -- - PROPOSED BUILDING COVERAGE 20.6% SYSTEM DESIGN: Iocus �A e omPs °� �° ,o O�or• Lewis ° Bay n LEACHING LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 22 PARCEL 367 LOCUS IS WITHIN FEMA FLOOD ZONE X NOTES (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO588J 1. DATUM IS NANNNN 8 DATED 7/16/2014 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT 4. DESIGN LOADING FOR ALL PROPOSED PRECAST -UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO .SCM. 40-4" PVC, 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROMBOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING; FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED. Yarmouth Health DMarpnent OVER V � S 21 Name Date w „W. ,-,0ofA„-,- UP.NIELA. ojALA CIVIL NO 46502 DANIEL A. OJALA CIVIL No.46502 &TE% ZONING SUMMARY ZONING DISTRICT: R-25 DISTRICT MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. BUILDING COVERAGE 25% MAX. BUILDING HEIGHT 35' -- - PROPOSED BUILDING COVERAGE 20.6% SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 :GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. H-10 POLY SEPTIC TANK LEACHING: 330 GPD / (.74) = 446 SF REQUIRED DEC C L02 20.5'X22'=4�-��. �CK 451 SF X .74 334 G®D OK USE A 20.5' XIPE AND STONE LEACHING FIELD DATE DANIEL A. OJALA, P.E., P.L.S. SITE PLAN OF #39 MAINE AVENUE WEST YARMOUTH. MA PREPARED FOR MICHAEL PARGOLI DATE: NOVEMBER 12, 2020 I 0" 508-362-4541 fax 508-362-9880 downc< com down cape engiWeeri� 01 civil engineers land surveyors 939 Mcin Street ( Rte 6A) YARMOUTHPORT MA 02675 20-217