Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Blde-21-005502
&25 62_ December 6,2021 Jimmie St.Pierre 25 Circuit Road North West Yarmouth, MA 02673 (508)685-1105 RECEIVED DEC 0 6 2021 Town of Yarmouth BUI�DING6DEpAR7MN7 By: 1146 Route 28 South Yarmouth, MA 02664 Building and Electrical Inspectors. Release of Permits...... Dear Sirs, I am requesting a release on a Building Permit and an Electrical Permit taken out by a solar company, (Vivant)???I have released this company and have the company Beacon Solar to install new solar panels.They will be in to secure new permits when the other permits are released. Thank You for your cooperate•n,Jimmie St.Pierre Commonwealth of Official Use Only Permit No. BLDE-21-005502 �. ,t Massachusetts BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:3/24/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to pertorm the electrical work described below. Location(Street&Number) 25 CIRCUIT RD NORTH Owner or Tenant ST PIERRE JIMMIE Telephone No. Owner's Address P 0 BOX 1232, SOUTH DENNIS, MA 02660-1232 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(17 Panels 5.5 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil B rs FI ALARMS No.of Zones No.of Switches No.of Gas Sur a o.of Detection and Initiatine Devices No.of Ranges No.of Air d. of No. ' • era • Devic . No.of Waste Disposers eat Pump Number o KW No M �f- �n • •i T e . = evices No.of Dishwashers \ S a:e/Area Heati o A r,$nne hon 0 Other: No.of Dryers eating Appliance KW •ec i `istems:* :.of "•vices or Equivalent No.of Water KW No.of No. f I at ` firing: Heaters Siens Ball s of Devices or Eau vale No.Hydromassage Bathtubs No.of Motors To elecommun ations fir' _No.of Devices r Equi ale OTHER: teach additional detail i it ,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When req • e. .y municipal policy.) Work to start: Inspection to be re s in accord. ce ith MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no pe 't for the p- formance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing .f tie. CHECK ONE:INSURANCE 0 BOND 0 OTHER • (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Lloyd R Smith Licensee: Lloyd R Smith Signature LIC.NO.: 15688 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:30 1ST ST, MELROSE MA 021764010 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 i Commonwealth,o//rJaisaci sel Official Use Only . _ cc�� Permit NF G3 J 2 . .- - 2epartment o/5ire Service6 CK- t Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),5 7 CMR 12 00 (PLEASE PRINT IN INK OR TYP ALL INFORM Nj Date: t li City or Town of: * ) To the Inspector o Wires: By this application the undersigne gi es notice of his or her intention to performmthe electrical work described below. Location(Street&Numbe ) Y , (1 t r C u( .,... 12,4 I.; . Owner or Tenant . . >) --r Telephone No.S O ' OgS. i(C`) Owner's Address r�/vJ �l Is this permit in conjunctio with a building permit? Yes No ri (Check Appropriate Box) Purpose of Building . Du.c,i 1 1 ,, Utili Authorization No. Existing Service jLiuAmps )a6 /age, Vo s Overhead Undgrd❑ No.of Meters 1 New Service Amps / Volts Overhead Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Ifl9{Q k 1 f! cc red 'moo led p:olantiote, O1ar s sif'' 15, S.c K1,3 (i i 5 Completion of the following table may be waived by thInspector of Wires. NoNo.of Recessed Luminaires No.of Ceil.-Susp. Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- L-1 iro.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners 'No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons Heat Pump Number Tons KW No.of Self-Contained No.of Waste Disposers Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent _ No.of Water Kam, No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent Telecommunications Wiring: No.Hydromassage Bathtubs No.of Motors Total HP No.of Devices or Equivalent OTHER: ( C_cJ Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of lectri al Work:61 . (When required by municipal policy.) Work to Start: - Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE CO RA E: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ❑ BOND ❑ OTHER ❑ (Specify:) I certify,under th pains and penalties of per' ry,that the information on this ap 'cation is true and complete. FIRM NAME: V IV t 1 &9 �( I.Cydne--- LIC.NO.: Licensee: L, a "\ e Signature LIC.NO.: i (If applicable.enter "exempt"in the license number line.) Bus.Tel.No.: 4Address: f4S NeA S 1531 P I �t (2.71-( ) Alt.Tel.No.:3 •-Q5 `ril *Per M.G.L. c.,147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent PERMIT FEE:$ Signature Telephone No. GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES'. 2015 INTERNATIONAL RESIDENTIAL CODE 2020 NATIONAL ELECTRICAL CODE 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION SHEET INDEX PV 0.0-COVER SHEET PV 1.0-SITE PLAN S 1.0-MOUNT DETAILS E 1.0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES E 3.0-WARNING LABELS E 4.0-WARNING LABEL LOCATIONS- E 5.0-BONDING DETAILS GENERAL ELECTRICAL NOTES GENERAL STRUCTURAL NOTES 1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL 1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED SYSTEMS- ROCK-IT RAIL-LESS SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BE WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SPACED AS SHOWN IN THE DETAILS-AND MUST BE STAGGERED TO ADJACENT SURFACE. FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE 2.UNLESS NOTED OTHERWISE SEE S 1.0-MOUNTING ANCHORS SHALL BE 5/16"LAG CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2-1/2'MIN PENETRATION INTO ROOF FRAMING. 3.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE 3.THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM 4.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE 4.ROOF LIVE LOAD=20 psi TYPICAL-0 psi UNDER NEW PV SYSTEM. INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE 5.GROUND SNOW LOAD=30 psf VOLTAGE. 6.WIND SPEED=140 mph 5.SEE"E 1.0 AND"E 2.0 FOR DIAGRAMS-CALCULATIONS-SCHEDULE AND 7.EXPOSURE CATEGORY=B SPECIFICATIONS vivint.Solar A sunrun(.oMrAn.F 1800 ASHTON BLVD.LEHI,UT,84043 1.877.404.4129 MA LK::170848115688A PHOTOVOLTAIC SYSTEM SPECIFICATIONS SYSTEM SIZE-5.525KW DC I 3.8KW AC ST PIERRE RESIDENCE 25 CIRCUIT RD N MODULE TYPE&AMOUNT-(17) JINKO SOLAR JKM325M-60HBL WITH SOLAREDGE P370 OPTIMIZERS WEST YARMOUTH,MA 02673 ACCOUNT:1427 855 0091 UTILITY MODULE DIMENSIONS:(UVNIH)66.3139.5/1.4 METER:2291136 �2 aPd e64 INVERTER:(1)SOLAREDGE TECHNOLOGIES SE3800H-US INTERCONNECTION METHOD(GRID-TIED):SUPPLY TAP SAS.6587255 ROC:MA-03 PV 0.O DRAWN BY:DIN DATE:03/09/2021 = REVISION:0 �+ PV STRING: ROOF SECTIONS: SYSTEM LEGEND MI PV STRING 1=17 MODULES ROOF PLANE 1 SLOPE=26° PV SYSTEM SIZE: ROOF PLANE 1 AZIMUTH=28° (N)5.525kW DC 3.800kW AC ROOF 1 MAT=COMPOSITION SHINGLE ROOF PLANE 2 SLOPE=26° ROOF PLANE 2 AZIMUTH=208° POINT OF INTERCONNECTION IN ROOF 2 MAT=COMPOSITION SHINGLE M EXISTING INTERIOR MSP TED TO UTILITY METER 2291136. —(N)SMART METER.LOCATED WITHIN 10' P OF MSP. NIP 0 ®(N)PV SYSTEM AC DISCONNECT. M (N) STRINGUS INVERTER: 0 O (N)17 JINKO SOLAR JKM325M-60HBL O p MOLHILES WITH P370 OPTIMIZERS MOUNTED ON THE BACK OF EACH MODULE. - O (N)JUNCTION BOX. ���(MOUNTED WITH SOLADECK) El o ce ui I— ' O V ce O / v U o 0 / CV Lei O • vivint.Solar' A sunrun con,—A",, 1800 ASHTON BLVD.LEHI,UT,84043 1.877.404.4129 MA LIC:170848(15888A ST PIERRE RESIDENCE 25 CIRCUIT RD N WEST YARMOUTH,MA 02873 UTILITY ACCOUNT:1427 855 0091 ,� METER:2291138 SITE PLAN)IIII' SNS 7255 PV 1.0 ROC:MA-03 DRAWN BY:DIN SCALE:3/16"=1'-0" DATE:o309z021 REVISION:0 B • MOUNTING NOTES ROCK-IT COUPLING MID CLAIM ROCK-IT COUPLING AI MU CLAMPIV l 1® Mill 0 ROCK-IT 3.0 COUPLING MID CIMP ROCK4T ' ROCK-IT SLUE `' PEDESTAL � METAL ROCK{T WNW3 PUSHING ® CWPLNG SHELF HEX FLANGE BOLT MI / -� 3005ERIE5 SS "Y���� I ROCK-IT CWPLNG SHELF ISOMETRX:VIEW Al / / A / COMP SHINGLES ``f SS LAG SCREW TORQUE=131.2 FT-LBS. � ,\\\ - SUEVIEW 1 &I6k1 U2' TIE PLATE HEX FLANGE BOLT SIDE VIEW AM SERIES 55 8 ILSCO SGB-4 GROUNDING LUGS ROCK-IT 3.0 MOUNT DETAIL s 1 0 NOT To SCALE "m TO SCALE U.L.LISTING FORECOFASTEN.2103 2 ROCK-IT 3.0 COUPLING ASSEMBLY - WEIGHT,2.3n. 51.0 NOT TO SGNE TOP VIEW MAX MOUNT SPACING LANDSCAPE MOUNT SPACING=72" CLAMP A ATTACHMENT,TYP LANDSCAPE CANTILEVER=24" CLAMP A ATTACHMENT,TYP PORTRAIT MOUNT SPACING=48" cOPLING,TYP PERMITTED COUPLNG,TVP PORTRAIT CANTILEVER=16' CANTILEVER:SEE MOUNTING NOTES I I CLAMP SPACING MOUNT SPACING'.SEE MOUNTING NOTES ROCK-IT SLUE IMIM CLAMP FRAMING,TYP MODULE,TYP MODULE METAL MODULE,TYP FLASHING EPDM BONDED WASHER --FRAMING,TYP FRAMING,TYP FORMS WATERTIGHT SEAL II L=LANDSCAPE CLAMP SPACING 4 PV SYSTEM MOUNTING DETAIL 5 MODULES IN PORTRAIT/LANDSCAPE L. I L=PORTRAIT S 1.0 NOT TO scut S S.0 Nm m SCALE CLAMP SPACING COMP SHINGLES 2-112' 3'MIN MID 6'MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE ONE HOLE STEEL STRAP CONDUIT MIN LAG RIAM Ak SSSCREW PV MODULE,TYP.MOUNT TORQUE=13S2 FT-LBS. TO FRAMING OF EXISTNG ROOF TYPE,PARALLEL WITH PLANE OF ROOF - - _ CONDUIT MOUNT BRACKET vuvint.Solar 6'MAXI A sunrun CUN1'Ati'- 1800 ASHTON BLVD.LEHI,UT,84043 SECTION VIEW /'� 11R' 1.877.404.4129 FLASHING OR TILE STRAP MA LIC:170848 115688A ,el - - ST PIERRE RESIDENCE 25 CIRCUIT RDN 3 SECTION VIEW WEST YARMOUTH,MA 02673 s lo HOT TD3U.£ 6 PV ARRAY TYP.ELEVATION 7 CONDUIT MOUNTING DETAIL UTILITY ACCOUNT:14278550091 51.0 N0T TO SCALE 51.0 Npi To s<AIF METER:2291136 ry U MOUNT DETAILS ROC:MA-03 StB-" S 1.0/ DRAWN BY:DIN SCALE:NOT TO SCALE DATE:03/09/2021 REVISION:0 B Photovoltaic System Conduit Conductor Schedule(Unless Otherwise Specified Conductors Shall be Copper) DC System Size(Watts) 5525 Tag Description Wire Gauge X of Conductors/Color Conduit Type Conduit Size m AC System Size(Watts) 3800 1 DC-to-DC Converter Output(PV Wire) 10 AWG 2(V+,V-)B/R Free Air N/A m 8 Total Module Count 17 1 EGC(Bare) 6AWG 1 BARE Free Air N/A o z ry Io 2 DC-to-DC Converter Output(THWN-2) 12 AWG 2(V+,V-)B/R FMC _1/2" - ¢ O n N 2 EGC(THWN-2) 12 AWG 1(GRN) FMC 1/2" ¢ l= f .7+ 3 DC-to-DC Converter Output(THWN-2) 12 AWG 2(V+,V-)B/R EMT 1/2" d ¢ .0 3 EGC(THWN-2) 12 AWG 1(GRN) EMT 1/2" d U p o 4 Inverter Output(THWN-2) 12 AWG 3(L1,L2,N)B/R/W EMT 1/2" N N A a A. 4 EGC(THWN-2) 12 AWG 1(GRN) EMT 1/2" Y A 5 Service Feeder(THWN-2) 6 AWG 3(11,L2,N)B/R/W EMT 3/4" f 5 GEC(THWN-2) 8AWG 1(GRN) EMT 3/4" L 0 vJ r, *. L_ C C rra`r• c.. r~ / C oT'1 ' y m V OI N '4'. 'crN r: • N SolarEdge SE3800H-US 5 IA "Conforms to ANSI p — C12.1-2008 inz PV System SMART Meter iu Side 705.11 j f Point of Interconnection,Supply Z m _ o 7 External Rapid MURRAYLCOGS > Z as OZ OOPEN TRANSITION Shutdown Disconnect; 240V/60A 2 POLE I�u w Square D DU221RB BREAKER BOX WITH 75'C J a N II NEMrminato sed. TERMINATIONS N`^—�— • O Z N 0 co o0 n NEMA3R,with 75'C w Z Z terminations /� No SHEET MRI I ^Ts Existing 240V/125A NAME: 1- -.. --.. 1.1Service Panel,Single .... C) ,�]RI.. I� LINE A Phase,minDiscon nett Main tad STRING 1:17 PV t 2 \ -�, MODULES I NEMA 3R Junction Bon t a _ LOA 1L A nit6 W/OPTIMIZERS """. 0 " tVt O 20A ! © SHEET NUMBER: 17 PV MODULES PER INVERTER=5525 WATTS ri 7" STC Visible/Lockabl e'Knife'AC Minimum GEC size 6 AWG copper ,I Disconnect W Inverter/Optimizer Specs PV Module Rating STc Conductor Calculations .-, Optimizer SolarEdge P370 Module Make/Model linko Solar JKM325M-6OHBL Wire ampacity calculated from 310.16&17 as appropriate with ambient temperature xi m or DC Input Power 370 Watts Max.Power-Point Current(Imp) 9.68 Amps calculations from Table 310.15(B)(1)&310.15(B)(2)and fill from 310.15 C Z ry m raceway adjustments ( ) DC Max.Input Voltage 60 Volts Max.Power-Point Voltage(Vmp) 33.6 Volts (1).Conduit on the roof shall be installed no less than 1"above the roof deck. v it a N DC Max.Input Current 13.75 Amps Open-Circuit Voltage(Voc) 41.1 Volts PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty r.. l DC Max.Output Current 15 Amps Short-Circuit Current(Isc) 10.2 Amps uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments 5 z « = 0 Max.string rating inverter dependent.See SE documents. Max.Series Fuse(OCPD) 20 Amps without the continuous duty uprating per 690.8(B),whichever results with a larger wire size. °' u 0 u Inverter Make/Model SolarEdge SE38 V 00H-US Nom.Max.Power at SIC(Pmax) 325 Watts Non-PV Circuit conductors use the ampacity in the 75°C column or the 90°C column with the r1 ' E• a CEC Efficiency 99 % Max.System Voltage SOW VDC(UL/IEC) relevant ambient temperature and raceway fill adjustments,whichever is less(110.14(C)& - AC Operating Voltage 240 Volts Voc Temperature Coefficient -0.28 I %/c 310.14(A)(2)).The rating of the conductor after adjustments shall be greater than,or equal to, j Cont.Max Output Current 16_Amps the continuous duty uprated current. DC Max Input Current 10.5 Amps ASHRAE 2017-BARNSTABLE MUNICIPAL More information about conductor calculations can be provided upon request. Input Short Circuit Current 45 Amps Highest Monthly 2%D.B.Design Temp.:29.5°C Calc.Ex:Wire Ampacity x Ambient Temp.Corr.Factor x Conduit Fill Adj.Factor>=Output Current Max Output Fault Current 17.5 A/20 ms Lowest Min.Mean Extreme D.B.:-19.2°C (Tag 1 Under Array): DC-to-DC Converter Output:10 AWG rated 30 A, 30 A>=18.75 A `s_ , (Tag 2 Attic): Q .1 Power Source(s)Output Calc:705.11 DC-to-DC Converter Output:12 AWG rated 20 A, 20 A>=18.75 A O (Tag 3 On Roof): Service Rating:100 Amps DC-to-DC Converter Output:12 AWG rated 20 A, 20 A>=18.75 A } `'�. (Tag 4 Exterior): PV Breaker Rating:20 Amps InverterOutput: >=12 AWG rated 20 A, 20 A 20 A 20A<=100A,OKmum r+ (Tag 5 Exterior): \ C Service Feeder:6 AWG rated 65 A, 65 A>=60 A •a`te 0 o -d as a rn ry .y a Other Notes g •Designed according to and all code citations are relevant to the 2020 National Electrical Code. s n •All interior raceways carrying DC current shall be metallic. 50 ,..° yr r[ Voltage and OCPD Calculations(690.7,690.9) 5 5 Z E iirr •-• PV Source Max Circuit Voltage:Module Voc a(1-(AT a Voc Coeff))[art.690.7(A)] -I CO ,'^,t JKM325M-6OHBL:41.1 V a(1-((25 C--19.2 C)a-0.28%))=46.19 V<=60 V < F a n 2 Z O N Inverter Output Circuit(s):Listed Output Current x 1.25[art.690.9(B)] SHEET Inverter 1:SE3S00H-US Max Output=16 A x 1.25=20 A<=20 A(OCPD) NAME: System output current w/continuous duty=20 A<=20 A(System OCPD) N 41 d 2 a SHEET NUMBER: N W All AC Disconnecting Means-AC Disconnect(s), Conduit,Raceways,and 1-Boxes(Labeled Every 10')and Installed within 3 ft of Rapid Shutdown Switch,Reflective,and shall be placed on Combiner Panels and Load Centers•er 690.54 rn Inverter 1 DC Disconnect per 690.53 both Panel Exterior&next to Main Disconnect per per 690.56(C)(2) PHOTOVOLTAIC AC DISCONNECT m g Reflective per 690.31(D)(2) c Z N. m MAXIMUM DC VOLTAGE PHOTOVOLTAIC POWER SOURCE RAPID SHUTDOWN SWITCH MAXIMUM AC OPERATING CURRENT- 16A 3. GI a N OF PV SYSTEM: aso v FOR SOLAR PV SYSTEM NOMINAL AC OPERATING VOLTAGE: Zoo V K j f ti PV System Disconnects per 690.13(B) PV with Rapid Shutdown Switch,Installed within 3 ft of Service Disconnecting b. m E Qu PV SYSTEM DISCONNECT Means with min.3/8"black capitalized text on yellow background&3/16" > black ca•italized text on white bac :round•er 690.56 C — wok•,aivlkw'rat�..A�x,.wa•. u4a , . L 0 TURN RAPID SHUTDOWN 0 ' SWITCH TO THE (n "OFF"POSITION TO • SHUTDOWN PV SYSTEM . c AND REDUCE _ S SHOCK HAZARD •; c IN ARRAY ! Ell •`� N o Plaque/Directory at Service Disconnecting Means per 690.56(B),&705.10 / 'I '' w m w CAUTION: MULTIPLE SOURCES OF POWER All Disconne'ct(s),Load Centes,a sconnecting Means-dCombiner u POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE Panels per 690.13(B)&690.15(C) ai a FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS ELECTRICAL SHOCK HAZARD SHOWNTERMINALS ON THE LINE AND o ri LOAD SIDES MAY BE ENERGIZED v, z IN THE OPEN POSITION Z m Q > g o0 _ Power Source Output Connection,Adjacent to &• cc ., Back-fed Breaker per 705.12(8)(3)(2) - N AT:� <• a ZZI7 METER AND MAIN POWER SOURCE OUTPUT CONNECTION SHEET -— EL � SERVICE DO NOT RELOCATE NAME: j�( r--r ,� THIS OVERCURRENT PROTECTION DEVICE ba / I Ijl 1 '\\ AC DISCONNECT Dual Power Sources in Main Service Panel y / / \ DC DISCONNECT and Sub Panel s •er 705.12 C) •SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER 3 a� LOCAL AHJ REQUIREMENTS•SIGNS/LABELS SHALL MEETTHE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS• SHEET DUAL POWER SOURCE SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING NUMBER: ------- REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS ' - ---- SOURCES:UTILITY GRID OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR AND PV SOLAR ELECTRIC SYSTEM WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO rtq WITHSTAND THE ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS W SITE PLACARD SHOWING ADDITIONAL POWER SOURCE WARNING MAXIMUM DC VOLTAGE RAPID SHUTDOWN SWITCH DUAL POWER SOURCE O1 4 c AND DISCONNECT LOCATIONS.PLACARD SHALL BE 10 OF PV SYSTEM "'V FOR SOLAR PV SYSTEM SOURCES:UTILITY GRID V n I MOUNTED ON EXTERIOR OF ELECTRICAL PANEL IA AND PV SOLAR ELECTRIC SYSTEM c '^ a rE Q o N WARNING MAIN BREAKER DE-RATED ¢ ® SOLAR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND q DUE TO SOLAR CIRCUITS �' C PHOTOVOLTAIC POWER SOURCE 11 r u WITH RAPID SHUTDOWN LOAD SIDES MAY BE ENERGIZED ***AMPS MAX ALLOWEDINTHEOPENPOSITION DONOTUPGRADE `�' a •, �� PHOTOVOLTAIC AC DISCONNECT ® WARNING C PV SYSTEM DISCONNECT ( (-1 , MAXIMUM AC OUTPUT CURRENT:*•*A POWER SOURCE OUTPUT CONNECTION �� NOMINAL AC OPERATING VOLTAGE:*••V DO NOT RELOCATE THIS OVERCURRENT PROTECTION DEVICE 0 .- ROOFTOP ARRAY O I • © �- C ti 0 e IF APPLICABLE ' . m d m a u 1 4 0 0 INSIDE 0 0 n G PANEL i v EVERY 1p�pNp 1.• ,y O ® CD ® ® V O CI 0 O © 5 °� .. 0 WITHIN 1'OF ELBOWS y'�,,r�r, I- W '. Z 00 m_ r�1' O i' ; Z 9Aq`, DC W W 0 m`, DISCONNECT O a ¢ 1 n �%`• INSIDE z z 0 SHEET COMBINER PANEL VISIBLE/LOCKABLE A/C VIVINT SOLAR METER VISIBLE/LOCKABLE A/C SUB PANEL MAIN SERVICE NAME: ROOFTOP SOLAR INVERTER JUNCTION BOX O (WHEN USED) DISCONNECT(WHERE (WHERE REQUIRED) DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL e REQUIRED) v, •••-value calculated for each a n 00 TYPICAL SOLAR GENERATION INSTALLATION account,for specific value see the 3 3 a (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page SHEET NUMBER: •SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY SIGNS AND LABELS•SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/B"WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE a ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS W • NOTES MODULE FRAME i=BONDING PATH ROCK-IT COUPLING .1 ,..ti. MID CLAMP ►„ � ...„ 4I --r ROCK-IT ROCK-IT SLIDE UL2703:2015 LISTED 1 PEDESTAL =- F 7 BONDING CLIP i BONDS SOLAR MODULEOil-... FRAME TO OPTIMIZER - i • OR MICRO-INVERTER '•'-' �" fj - OPTIMIZER MOUNTED Ij jI j I OROCK-IT INTEGRATED BONDING WITH UL2703 TO MODULE FRAME I' i! I• NOT TO SCALE , I� � I� �, ©OPTIMIZER BONDING DETAIL WITH UL2703 NOT TO SCALE PV MODULE TO ACT AS AN ACTIVE GROUNDING COMPONENT TO EGC im 11 ETIN = i imi IT im i • GROUNDING LUG(SEE S1.0 DETAIL#2) •--• E-W BONDING PATH. n_.._...IMJI. 1.1 I I I 1M I I I 11= _El_ l_ w_11 I Wilq Ili I N-S BONDING PATH,SEE DETAIL#1. ill.1-11- I E ROCK-IT COUPLING VIVIf1t.Solar 1111- 1800 ASHTON BLVD.LEHI,UT,84043 1.8 .1 ❑ ROCK IT COUPLING4129 77404 MA L7084 1515 8B8A ST PIERRE RESIDENCE II = „ =II II = 't 25 CIRCUIT RDN WEST YARMOUTH,MA 02673 UTILITY ACCOUNT 1427 855 0091 METER:2291136 U. ©SYSTEM BONDING LAYOUT WITH UL2703 BONDING DETAILS OC:MAA-03 E 5.0 NOT TO SCALE DRAWN BY:DIN SCALE:NOT TO SCALE DATE:03109/2021 REVISION:0 3