Loading...
HomeMy WebLinkAboutEngineer Plans - 2020-100- EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE 6?wllageBrook Road -W-EXISTING WATER SERVICE t�hilV U Fl ZOZ1 EXISTING LEACH PIT / oO'o xi - G - EXISTING GAS SERVICE 70 BE PUMPED, FILLED WITH V -OHW-OVERHEAD WIRES x n11i:�l'I LCP 3p6, SAND AND ABANDONED: e�oo TEST PIT se EXISTING SEPTIC TANK BENCHMARK TOP of TANK, EL.=101.02 LEGEND e' INV. (OUT)= 99.69_-(VER1FY) �y�' BENCHMARK�jo���� COR./CONC. STEP Wm09th Heafth A ` . _. 1 EL.=102.59 `DMaPtNCat ♦LD ` LOCUS MAP NOT TO SCALE IF FND - CB ate GENERAL NOTES: fent '00" E 104.87 Name 107.86 105,40 120 0' 0 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL ij 106. \ BOARD OF HEALTH AND THE DESIGN ENGINEER. SHED 12,g' J VENT " 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE 1 LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: /- 1. 1\ 10' m HE 106.24' V f-- :;'rte• YC.f 0 13 -310 CMR 15.405(1)(b): LOCAL UPGRADE APPROVAL 1) A 9' variance, S.A.S. to cellar wall, for on 11' setback. •°.' 107410 103.91 01.$9 X�� .� ~ y ..... � F-:': 0 ;':.1 10143' PROPOSED S.A.S. 2) A 2' variance to the 3' maximum cover requirement, for up to 5' of max. cover. S.A,S, shall be H-20 and vented. 102.01 -{= •, Ir•:" `'1""� 0. •.1,1.,. '.�'IN 2-500 GALLON CHAMBERS 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR 104�/,s 102.1 0 10,22' SURROUNDED W/4' STONE TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. %� 013e 101.81T 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING tf X FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN AT10 BM ' 101.48 ENGINEER BEFORE CONSTRUCTION CONTINUES. w rinse BH J02,19 2,59 Q') / 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. / 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF o'pO t 9981 / INSTALL 40 MIL POLY LINER VVV THE CONTRACTOR' OR OWNER TO NOTIFY THE LOCAL BOARD OF p OO FOR PROPER INSPECTIONS DURING CONSTRUCTION. .- 101.9 ,EXISTING ,,rr� TOP OF LINER, EL.POLY cn ! BOTT. OF LINER, EL.=96.0 `HEALTH Y/. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. Z GARAGE 103.Q7 i /NOUSE(1`54) �/ �� � THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. �" F.F.=103. ft 99989. Y� �/''`�}O O ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS. AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE / `t+-ry 0 C DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY 70 X OF Mass THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 101 /,..� 101.06 CyG✓' PETER T. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS McENTEE �, IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND Q LOT 2O o CIVIL REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 102 1 101 24 3 ,�// •� .� 12,000.±SF No. 35109 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE W L =' P X 99.47 / I E @ INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. p2'N 13, THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. .-9 120.00' " CB -� 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC ` ^ SYSTEM COMPONENTS NOT SHOWN ON THE PLAN ( N 12°10'00" W ,�-'" 97.18 `'`ZZ 15. SUBJECT SITE LIES WITHIN A STATE REGULATED ZONE II. -' 95.94 PARCEL ID: 68-09 101.27 100.42 98'88 97'86 9666 'PLAN REVISION 12/22/20 PROPOSED SEPTIC SYSTEM UPGRADE PLAN / ADDPOLY LEER, ADD NOTE 15 54 VILLAGE BROOK RD SOUTH YARMOUTH MA VILLAGE BROOK ROAD AND HANGE BEDROOM O OWNER OF RECORDUNT Prepared for: D.A. Brown, Inc., P.O. Box 145, Centerville, MA 02632 POOLE, JOHN B CAREY, NOREEN E Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. 1"=20' P.T.M. 287-20 PLAN REFERENCE Nl/ 54 VILLAGE BROOK RD 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. CERTIFIED PLOT PLAN BY RYDER & WILCOX,, ORLEANS, MA, DATED 11/21/02 S. YARMOUTH, MA 02664 (508) 477-5313 11/1/20 P.T.M. 1 Of 2 VA L SEPTIC TANK INSTALL RISERS & COVERS OVER INLET AND SET TO 6" OF FINISH GRADE. T.O.F.=103.1 ± -E.G. EL.=101.5± � F.G. EL.=101.8± L= 24' ® S=1% (MIN.) 4'SCH40 PVC 48" LIQUID LEVEL ADD GAS BAFFLE INV.=98.17 INV.=99.69± EXISTING EXISTING SEPTIC TANK NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION. 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED STABLE BASE OR 6' CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) CONTRACTOR SHALL INSTALL A GAS BAFFLE ON THE OUTLET TEE. DESIGN CRITERIA NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:98.00 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED D -BOX / PROPOSED S.A.S. INSTALL WATERTIGHT RISER & / PROVIDE ONE ACCESS MANHOLE TO WITHIN 3" COVER SET TO 6" T GRADE VVV OF FINISH GRADE FOR INSPECTION PURPOS F.G. EL.=100,0± VENT F.G. EL.=101.5± to 103.0± MAINTAIN 2% GRADE (MIN.) OVER S.A.S. L = 5' ® S=1% (MIN.) 4"SCH40 PVC 16r) 2' EFF.DEPTH PROPSED7.x/-a1F` . D BOX INV.=97.50 - TOP CONC. ELEV.=98.6± BREAKOUT ELEV.=98.00 INV. ELEV.=97.50 BOTTOM ELEV.=95.50- 4' MIN. OF NATURALLY OCCURRIt PERVIOUS MATERIAL 5' MIN. ABOVE GROUNDWATER BOTT. OF TP, EL.=89.7 SEPTIC SYSTEM PROFILE NUMBER OF BEDROOMS: 2 SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN (0.74 GPD/SF LOADING RATE) DAILY FLOW: 220 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF 74 GPD/SF EXISTING SEPTIC TANK: 1000 GALLON CAPACITY PROPOSED DISTRIBUTION BOX: 1 INLET, 3 OUTLETS USE 2-500 GALLON LEACHING CHAMBERS IN SERIES SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F. BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. TOTAL AREA: ...................................... .. ... . ........... .471,2 S.F. DESIGN FLOW PROVIDED; 0.74 GPD/SF(471.2 SF)348.7 GPD 4.8 q'' EFFECTIVE WID' 4 TH = 12.8' -�1 2 x 8.5'=17.0' EFFECTIVE LENGTH = 25.0' LEACHING SYSTEM SECTION TO 1-1 WASHED SEPTIC LAYOUT �1�11 AIS til (� 1�1 �1 t'=111 � .. \ 1=11 1�1� L. 11�11�11 111 1=f 3" LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE (OR APPROVED FILTER FABRIC) SOIL LOG✓ DATE: OCTOBER 20, 2020 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) WITNESS: MALLORY LANGLER, R.S. HEALTH AGENT ELEV. TP DEPTH 100.7 A all 100.3 98.2 95.0 LOAMY SAND 10YR 4/2 B LOAMY SAND 10YR 5/8 C1 MEDIUM SAND 2.5Y 6/4 5" 500 GALLON CAPACITY, H-20 LOADING 3 CHAMBERS m cz FINE SAND 2,SY 7/4 89.7 132" NO GROUNDWATER, PERC RATE: <2 MIN./IN. 58" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 54 VILLAGE BROOK RD, SOUTH YARMOUTH, MA Prepared for: D.A. Brown, Inc., P.O. Box 145, Centerville, MA 02632 Engineering by: SCALE DRAWN JOB. N0. Engineering Works, Inc. NTS P.T.M. 287-20 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 11/1/20 P.T.M. 2 of 2 4" KNOCKOUT 20" DIA. COVER 4" KNOCKOUT 04" KNOCKOUT 4" KNOCKOUT 500 GALLON CAPACITY, H-20 LOADING 3 CHAMBERS m cz FINE SAND 2,SY 7/4 89.7 132" NO GROUNDWATER, PERC RATE: <2 MIN./IN. 58" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 54 VILLAGE BROOK RD, SOUTH YARMOUTH, MA Prepared for: D.A. Brown, Inc., P.O. Box 145, Centerville, MA 02632 Engineering by: SCALE DRAWN JOB. N0. Engineering Works, Inc. NTS P.T.M. 287-20 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 11/1/20 P.T.M. 2 of 2