Loading...
HomeMy WebLinkAboutEngineer Plan - 2022TBM = EL. 20.2 PORCH SLAB YARMOUTH LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE -- gg -- EXISTING CONTOUR EXISTING SPOT GRADE EXISTING WATER SERVICE JAIN 2 4 2022 HEALTH DEPT. 3, GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND REMOVED, REPLACE WITH CLEAN MEDIUM PERC SAND PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING 14. ALL PIPE TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. OTHERWISE) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. DESIGN SANITARIAN TO INSPECT AND CERTIFY INSTALLATION. PROPOSED YARMOUTH, NOTE: TO PREVENT BREAKOUT, THE PROPOSED NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS FINISH GRADE SHALL NOT BE < EL:16.14 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK PROPOSED D -BOX PROPOSED S.A.S. T.O.F. EL.=20.0 INSTALL RISERS & COVERS OVER INLET & OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & COVER INSTALL A 4" DIAMETER INSPECTION PORT OVER SET TO 6" OF GRADE liv. dindin sun ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. rm 1rm KIT F.G. EL.=19.01 F.G. EL.=19.01 F.G. EL: 19.01 F.G. EL: 19.0(MAX.) screen �- bath (siarrn b)j i 9" MIN COVER/ m, L bed rm bed bed ���_rm stor. L =40'1 36• MAX COVER L q6' ®S=1% (MIN.) L = 15(MAX) INSTALL TWO INSPECTION PORTS (MIN.) EL = 17.82 ®S=1& (MIN.) 4"SCH40 PVC 4•SCH40 PVC 0 S=1% (MIN.) 4"SCH40 PVC IA C 10' 14, 6 3.8" TO INV. =16.80 4S' LOuly LEVEc INV.=16.55 INVERT _ FLOOR PLAN GAS BAFFLE PROPOSED D BOINV.=15.90 J4 ROWS OF 4 UNITS AT 6.25'/UNIT WEDGE = 25.0'/ROW x AM M JM INV.=16.1 �� INV.= 15.75 SOIL ABSORPTION SYSTEM (PROFILE) EXISTING 1.500 GALLON SEPTIC TANK EXISTING SEWER OUTLETS RESTORE VEGETATIVE COVER BACKFILL WITH CLEAN PERC SAND TO TOP OF CHAMBERS �P�� pTss9 _ p � ONTRACTOR SHALL NOTES: 2) DPEO INVERTS PRIORCONSTRUCTION .:... ...: �..: .. �......:`•.. BREAK 4' .• ' , 'I'j„ INV. MEYER �� No., 11140 TOVERIFY SHALL LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX BOTTOM ELEV.= 14.85 EXISTING SUITABLE 2.83' MATERIAL �)� �NITARIP� 1 �Z INCH CRUSHED STONE BASE, AS SPECIFIED IN 5' MIN. ABOVE BOTTOM OF 310 CMR 15.221(2) 3) REPLACE EXISTING 1,500 GALLON SEPTIC TANK T.P. EXCAVATION OR G.W.. EFFECTIVE WIDTH = 4 x 2.83' = 11.32 (5.11' PROVIDED) 1\ USE 4 ROWS OF 4 -HIGH CAPACITY WITH 1500 GALLON SEPTIC TANK IF FAILED, ADJ. GROUNDWATER EL.=9.70 _ INFILTRATOR (H20) UNITS DAMAGED, NOT H2O LOADING, OR UNDERSIZED. ~ 75 �I 4) INSTALL INLET & OUTLET TEES W/ I GAS BAFFLE AS REQUIRED SEPTIC SYSTEM PROFILE TYPICAL SECTION N.T.S. WT.e .111 ul-I DESIGN CRITERIA **PROP IS NOT IN ZONE OF CONTRIBUTION** SOIL LOG NUMBER OF BEDROOMS: 3 BEDROOM DESIGN DATE: FEBRUARY 1, 2012(TP-1)/JANUARY 19. 2022(TP-2) SOIL TEXTURAL CLASS: CLASS I SOIL EVALUATOR: DARREN M. MEYER, R.S., CSE #1614 WITNESS: PHIL RENAUD, YARMOUTH BOH DESIGN PERCOLATION RATE: <2 MIN/IN Elev. TP -1 Depth Elev. TP -2 Depth DAILY FLOW: 330 G.P.D. 18.0 0" 19.0 0" 16` DESIGN FLOW: 330 G.P.D. A A GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) 1OYR LOAMY s4A/N2D LO1100YYR s4A/N2D PROPOSED SEPTIC TANK: 330gpd x 200% = 660 gpd (USE EXIST. 1,50OG CAPACITY) 17'17 10" 18'17 10" LEACHING AREA REQUIRED: (330) = 445.95 S.F. B LOAMr sAND B LOAMY SAND SECTION INVERT 74 1CYR 5/8 10YR 5/6 HEIGHT END CAP DISTRIBUTION BOX: (4 OUTLETS (MINIMUM)) 28" 16.25 33" 15.67 C C INFILTRATOR - HI CAPACITY (H20) CHAMBER PRIMARY S.A.S. MEDIUM SAND PERC Y 14,97 MEDIUM SAND USE 4 ROWS OF 4 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE PERC a 14.0 2.5Y 6/4 2.5Y 6/4 PROPOSED SEPTIC SYSTEM SITE PLAN BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) 7.50 126" 8.01 1 132" (CHAMBER) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473 SF PERC RATE <2 MIN/IN. (-Cl- HORIZON) PERC RATE <2 MIN/IN. (•C• HORIZON) GROUNDWATER OBSERVED AT 126` (EL 7.5) NO GROUNDWATER OBSERVED INDEX WELL: MFW -29 ZONE: B I 12 NORTH ROAD WEST YARMOUTH, MA TOTAL AREA = 473 SF LEVEL: 7.9 ADJUSTMENT: 2.2 Fr. Prepared for: C. Heath/Ready Rooter Exc. DESIGN FLOW PROVIDED: 0.74GPD/SF(473SF) = 350 GPD > 330 GPD req'd ADJUSTED HIGH GROUNDWATER AT EL 9.7 Engineering by: MEYER & SONS, INC. Surveying by: halter & Associates SCALE NTS DRAWN D.M.M. " 1, Darron M. Meyer, R.S., CSE, hereby certify that 1 am rumen a by MAOEP pursuant to 510 CMR 15.017 approved PoBOX881 506 375-0735 ( ) DATE: CHECKED SHEET N0. to conduct Boll evaluations and that the above anal has been by consistent with the yha EASTSANOWACH, MA 02537 requlromerde of 310 CMR 15.017. I further certify that I have passed the Sotl Ewl. Exam in October, 1999. passed the Ev in 503,W-292 01/20/22 1 D.M.M. 2 2 of