HomeMy WebLinkAboutEngineer Plans - 2021SOIL LOGS
DATE: MARCH 23, 2021
SOIL EVALUATOR: DARREN MEYER. RS, CES 1614
WITNESS: MALLORY LANGLER, YARMOUTH HEALTH
Elev.
TP -1
Doth
23.1
®
0"
-- 98 --
FILL
+ 96.52
21.43
—W—
20"
A, LOOMY �D
TEST PIT
¢
21.02
10YR
25"
6 SILT LOAM
18.43
10YR 5/6
56"
G
a
m
SANDY
10YR 33/2
16.43
80"
C2
Z
��
SAND
2 SY 6/e
12.43
128"
PERC RATE <2 MIN/N. ("Gr HORIZON!)
08S. GROUNDWATER AT W. ELEY. 16.43
WELL: SDN -252, ZONE A LEVEL 47.1• ADJUSTMENT: 12 FT
ADJUSTED GROUNDWATER ELEV. 17.63.
LOT 38c5
23,0963 S.F.
(0.531 AC.)
Permit valid for REPAIR OF SEPTIC SYSTEM
ONLY, due to State and Local septic variances.
Board of Health review and approval is required for
any future additions/renovations/alterations to
sewage facilities and/or structures/dwelling,
Yarmouth Health Department
APPROVED
Nome Date
\
5 FT. SOIL REMOVAL PROP. GEO(
(SEE NOTE 14) (SEE NOTE
PROPOSED 40 ml POLY
LINER (SEE NOTE 15)
N
ND GAy g5t ttt E
� N
n
-A
i
i
NW ��
i
TBM' = E
CATCH E
EXIST.
LEGEND
�—/
PROPOSED CONTOUR
®
PROPOSED SPOT GRADE
-- 98 --
EXISTING CONTOUR
+ 96.52
EXISTING SPOT GRADE
—W—
EXISTING WATER SERVICE
TEST PIT
TBM' = E
CATCH E
EXIST.
1,000G
5
>
SEPTIC
TANK II
PUCMP
C AMB.
E -e eet C'AC- Pct-� / r" 4 'O -
= 30'
I`IAY 2 0 2021
HEALTH DEPT
SURVEY BY: WELLER AND ASSOC.
YARMOUTHPORT
LOCUS
83 THATCHER
LOCUS MAP
LOCUS INFORMATION
PLAN REF: 144/093
TITLE REF: 31210/0127
PARCEL ID: MAP 122 PAR. 021
FLOOD ZONE: "X"
COMMUNITY PANEL: 25001C0559J DATED:07/16/14
SEPTIC SYSTEM
REPAIR PLAN
LOCATED AT:
83 THATCHER SHORE RD.
YARMPOUTHPORT, MA
PREPARED FOR
FRANK PUZIO
, A , A A MAY 18, 2021
rEVENti5CX% I
1140
MEYER & SONS INC.
P.O. Box 981
E. SANDWICH, MA 02537
PH. (508)360-3311
fax (774)413-9468
meyerandsonstitle5@gmail.com
SHEET 1 OF 2
697
5
>
3
�
3
¢
o
a
m
z
Z
4
LOCUS MAP
LOCUS INFORMATION
PLAN REF: 144/093
TITLE REF: 31210/0127
PARCEL ID: MAP 122 PAR. 021
FLOOD ZONE: "X"
COMMUNITY PANEL: 25001C0559J DATED:07/16/14
SEPTIC SYSTEM
REPAIR PLAN
LOCATED AT:
83 THATCHER SHORE RD.
YARMPOUTHPORT, MA
PREPARED FOR
FRANK PUZIO
, A , A A MAY 18, 2021
rEVENti5CX% I
1140
MEYER & SONS INC.
P.O. Box 981
E. SANDWICH, MA 02537
PH. (508)360-3311
fax (774)413-9468
meyerandsonstitle5@gmail.com
SHEET 1 OF 2
697
PROPOSED TANK
INSTALL RISERS W/IN 6. OF FINISH GRADE
TOP OF
FOUNDATION -
EL =25.5 T- EL24.80f r
(MIN.)BE
r SCH HTws 4 To4' b PC
NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS
PUMP CHAMBER o-eox
INSTALL RISERS to FINISH GRADE INSTALL RISERS TO GRADE W/ LOCKING COVER
EL24.8* r EL24.0t r EL24.0d: F.G. EL- 24.501
22.60
INV.- 22.85- EXIST. 1,000 GALLON SEPTIC TANK
NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING
PIPE INVERTS PRIOR TO CONSTRUCTION.
2) PUMP CHAMBER AND D -BOX SHALL
BE SET TRUE TO GRADE ON A MECHANICALLY
COMPACTED SIX INCH CRUSHED STONE BASE AS
SPECIFIED IN 310 CMR 15.221(2).
3) INSTALL INLET B OUTLET TEES AS REQUIRED.
4) GAS BAFFLE W/ FILTER TO BE INSTALLED ON OUTLET TEE
AS MANUFACTURED BY TUF-TITS, ZABEL OR EQUAL
5) INSTALL SANITARY TEE IN D -BOX
WITH WATERTIGHT JOINTS WARE HIGH WATER ALARM
FLOAT TO GP 2000 HIGH WATER ALARM PANAL ON
CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP.
s
HOISTING CABLE
i/8" DIAMETER.
PC INV.(OUT)=22.0
ALARM ON EL' 19.83
PUMP ON EL' 19.33
PUMP OFF EL' 19.0
BOTTOM OF INT. P.C. EL 18.0
AM s : s `-22.00
PROPOSED 1,000 GALLON PUMP CHAMBER
SEPTIC SYSTEM PROFILE
N.T.S.
INV.- 23.35/ D -BOX -""*-
TEE SHALL NOT EXTEND
BELOW FLOW UNE
(USE H-20 DB -5)
- PROVIDE WATERTIGHT CONCRETE RISER
WITH SECURED COVER TO GRADE
NEMA 4 JUNCTION BOX CORROSION RESISTANT
& UQUID-TIGHT CABLE CONNECTORS SUPPORTED
BY 1-1/4" PVC ODNDUIT. JOINTS TO BE MADE
WATERTIGHT
.2"BALL VALVE W/ UNIONS SCH. 80 PVC
GEORGE FISHER CO. MODEL NO. 560 OR EQUAL
2"SCH. 40 DISCHARGE TO D-BOX
-2"SCH. 40 TEE w/ CLEAN-OUT CAP
PROVIDE 1/4" WEEP HOLE IN DISCHARGE
PIPE FOR SELF -DRAINING FORCE MAIN
CHECK VALVE SCH. 80 PVC
. FLOWMATIC MODEL No. 208S
PROVIDE 2- WADE ANGLE FLOATS: 1\� 2" SCH. 40 PVC DISCHARGE PIPE
FLOAT NOA: PUMP ON/OFF (BARNES 073618 OR EQUAL)
FLOAT NO.2. ALARM ACTIVATION (BARNES 073612 OR EQUAL) BARNES SEV412 PUMP .5 H.P. 115 V
2" DISCHARGE PASSING 2" SOUDS OR EQUAL
NOTE: SEPTIC TANK/PUMP CHAMBER TO BE FACTORY WATERPROOFED AND SEALED WITH THOROSEAL OR EQUAL
PUMP & ACCESSORIES AVAILABLE AS A UNIT
THROUGH ACAE/S HORSY PRECAST., HARWICH MA (800) 560-9949
1.000 PUMP CHAMBER
A= 8.5' x 5' x 4 x 62.4 - 10608 ibs
around cover. 8.5' x 5' x .75 x 120 - 3,825 lbs
empty tank: B4ODO lbs
3,825 + 8,000 - 11,625 lbs > 10,608 lbs
SEPTIC TANK/PUMP CHAMBER BUOYANCY CHECK O.K.
DOSING & STORAGE REQUIREMENTS
DAILY FLOW: 330 GPD
DOSING REQUIRED: 4 CYCLES/DAY (SAND)
330 -°s- 4 - 82.50 GALLONS/CYCLE
DISTANCE REQUIRED BETWEEN PUMP
ON AND PUMP OFF FLOATS:
82.50 GAL/CYCLE - 250 GAL/FT = 0.33 FT/CYCLE (4'
STORAGE REQUIRED ABOVE WORKING LEVEL: 440 GALLONS
STORAGE PROVIDED:
INV. EL: 22.0 - ALARM ON EU 19.83 =2.17'
STORAGE PROVIDED - 2.17' X 250 GAL/FT = 542.0 GALLONS
PUMP DETAIL
N.T.S.
GENERAL NOTES:
NOTE: TO PREVENT BREAKOUT, THE PROPOSED
FINISH GRADE SHALL NOT BE < EL:. 36
FOR A DISTANCE OF 15' AROUND THE
PERIMETER OF THE S.A.S.
.G. EL: 24.50(MAX. ON CORNERS)
INV.ELEV.=22.97
BREAKOUT=TOP ELEV.-23.36
INV. ELEV.= 22.97
BOTTOM ELEV.= 22.68
5' MIN. ABOVE BOTTOM OF
T.P. EXCAVATION OR G.W.
(5.05' PROVIDED)
ADJ. GROUNDWATER EL.=17.63-
1. ALL CHANGES TO THIS PIAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK IREMENTS
OF THE STATE ENVIRONMENTAL MATERIALS LCODE. TITLE AND CONFORM TO THE� APPLICABLE
LOCAL RULES AND REGULATIONS EXCEPT AS USTFD ON PACE 1.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED WRING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED
TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR.
9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES. PRIOR TO BEGINNING
CONSTRUCTION.
10. ALL PIPING TO BE 4" SCH 40 O 1/8 -/Fr (UNLESS SPECIFIED)
11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION
12. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING.
13. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING.
14. REMOVE ALL UNSUITABLE SOILS 5FT MOUND PROPOSED
LEACHING TO EL 16.43 OR TOP OF "C2" LAYER AND REPLACE
WITH CLEAN MEDIUM SAND PER TITLE 5.
15. PLACE 40 ml POLY BARRIER MOUND ENTIRE EDGE OF SOIL
REMOVAL FROM EL 10.0 TO 6.0 TO PREVENT BREAKOUT
16. PLACE GEO-GRID UNDER D -BOX AND LEACHING TO SUPPORT
SYSTEM FROM DROPPING. (AS SHOWN)
4 ROWS OF 6 UNITS AT 4.0'/UNIT - 24.0'/ROW
SOIL ABSORPTION SYSTEM (PROFILE)
PERC SAND
L3
(PROP. GEOGRID)
EXISTING SUITABLE
MATERIAL
''ECTIVE WIDTH = 4 x 2.83' = 11.321
USE 4 ROWS OF 6 INFILTRATOR QUICK 4 PLUS
STD LP (3.3" INVERT) UNITS -NO STONE
TYPICAL SECTION
Ku
DESIGN CRITERIA
NUMBER OF BEDROOMS: 2 BEDROOM DWEWNG/3 BEDROOM DESIGN
SOIL TEXTURAL CLASS: CLASS I DESIGN PERC RATE: <2 MIN/IN
DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D.
GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER)
SEPTIC TANK/PUMP CHAMBER: 330 gpd x 200% = 660 gpd
USE EXIST. 1000G SEPTIC TANK W/ 1000G PUMP CRAM.
LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F.
DISTRIBUTION BOX: (3 OUTLETS (MINIMUM))
PRIMARY S.A.S.
USE 4 ROWS OF 6 - INFILTRATOR QUICK 4 STD LP (3.3" INVERT)
UNITS WITH NO STONE
BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER)
(CHAMBER UNITS) 24 UNITS x 4.00 LF x 4.73 SF/LF = 454.08 SF
DESIGN FLOW PROVIDED:
TOTAL AREA = 454.08 SF
08SF) = 336 GPD > 330 GPD req'd
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
83 THATCHER SHORE ROAD, YARMOUTH, MA
Prepared for: Frank Puzio
System Design and Topography Plan by: SCALE DRAWN DATE
MEYER& SONS, INC. N.T.S. DMM 05/18/e
PO BOX 961
E4ST54NDWICH, MA 02537 REV. DATE CHECKED SHEET NO.
59e-362-2922 DMM 2 Of 2