HomeMy WebLinkAboutBlde-21-006872 plans GOVERNING CODES .. ALL WORK SHALL CONFORM TO THE FOLLOWING CODES: 2015 INTERNATIONAL RESIDENTIAL CODE 2020 NATIONAL ELECTRICAL CODE 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION 0 /2) e'''' SHEET INDEX PV 0.0-COVER SHEET PV 1.0-SITE PLAN ,�j S 1.0-MOUNT DETAILS , E 1.0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES <95° E 3.0-WARNING LABELS E 4.0-WARNING LABEL LOCATIONS E 5.0-BONDING DETAILS GENERAL ELECTRICAL NOTES GENERAL STRUCTURAL NOTES 1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL 1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED SYSTEMS- ROCK-IT RAIL-LESS SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BE WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SPACED AS SHOWN IN THE DETAILS-AND MUST BE STAGGERED TO ADJACENT SURFACE. FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE 2.UNLESS NOTED OTHERWISE SEE S 1.0-MOUNTING ANCHORS SHALL BE 5/16"LAG CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2-112"MIN PENETRATION INTO ROOF FRAMING. 3.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE 3.THE PROPOSED PV SYSTEM ADDS 3.0 psl TO THE ROOF FRAMING SYSTEM dam 4.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE 4.ROOF LIVE LOAD=20 pal TYPICAL-0 pal UNDER NEW PV SYSTEM. INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE 5.GROUND SNOW LOAD=30 psl cP VOLTAGE. 6.WIND SPEED=140 mph 5.SEE*E 1.0 AND*E 2.0 FOR DIAGRAMS-CALCULATIONS-SCHEDULE AND 7.EXPOSURE CATEGORY•B SPECIFICATIONS l vwmt.Solar �' n sunrun c,_�r�1r'a;v 1 . teoDABHTO.8 BLVD.4044129 UT,84043 ten 4D4e12s µ� MA LIC:170848 1 15888A e,o°µ PHOTOVOLTAIC SYSTEM SPECIFICATIONS ., /* vFEo SYSTEM SIZE-5.525KW DC 13.8KW AC ESTEVEz RESIDENCE s ``� MODULE TYPE&AMOUNT-(17) JA SOLAR JAM80S17-325/MR WITH SOLAREDGE P370 OPTIMIZERS WESTYARMOUT MA0 MIRROR BROCK 022873 o ck MODULE DIMENSIONS:(L/W/H)0/0/0 UTILITY METER: 1; 0050 s °f o(° INVERTER:(1)SOLAREDGE TECHNOLOGIES SE3800H-US -P°' 4v06 INTERCONNECTION METHOD(GRID-TIED):LOAD BREAKER S i MI S-66428 • ROC:MA.03 PV 0.01 DRAWN BY:DIN DATE:05118V2021 REVISION:0 I SYSTEM LEGEND PV STRING: ROOF SECTIONS: PV SYSTEM SIZE: %%PV STRING 1=17 MODULES ROOF PLANE 1 SLOPE=30° (N)5.525kW DC 13.800kW AC ROOF PLANE 1 AZIMUTH=238° ROOF 1 MAT=COMPOSITION SHINGLE ROOF PLANE 2 SLOPE=26° ROOF PLANE 2 AZIMUTH=238° I—I POINT OF INTERCONNECTION IN ROOF 2 MAT=COMPOSITION SHINGLE I I EXISTING INTERIOR NSF TIED TO UTILITY METER 2291880. OP(N)SMART METER LOCATED WITHIN 10' OF NSF. ®(N)PV SYSTEM AC DISCONNECT. a((NI 1 PV STRING INVERTER: SE3800HdIS PJ IN)17 JA SOLAR JAN80311MIZE MODULES WITH P970OPT1MQERS MOUNTED ON THE BACK OF EACH O �I, MODULE r((MM)OD TO UNCTION BOX, -'1 UNTEV MODULE) o 0 EXISTING DETACHED UTILITY METER (2291880) ' / ' / " . A. •/ _,,_ 0 0 __ /4. N p vivint.Solar A sunrun c(,E. A 1800 ASHTON BLOM LEHI,UT,84043 1.877.404,4129 28 MIRROR BROOK RD MALIC 170848)1 NNIA FRONT OF HOUSE. ESTEVEZ RESIDENCE 28 MIRROR BROOK RD F WEST YARMOUTH,MA 02873 F UTILITY ACCOUNT:1428 852 0050 i METER:2281B80 SITEPLAN SICBB42873 DRAWN BY:DIN ROC:NA•03 PV 1.0; SCALE:3/16"=1'0" DATE:061912021 REVISION:0 MOUNTING NOTES -� ROCK4T COUPLING MO CLAMP ROCIFIT COUISO OPUNNG LAMP ® 11111 A 1per _'� Jt11■1IIII ., ROCK•IT 30 COUPLNG ROCK4f ' ROCK4 SLIDE MID CLAMP PEDESTAL ' '- - L RCOM Vir-lill".10....S111Mr FLASHING ® COIMNOHEX FWDESOLTIII ■300 SERIES SS ROCIFITCOUPl2D SHELF I .�• I COMP SHINGLES `� aeLAoac�w , T[ , TOROUE•1332 Eng& MOIL y106 ,a I. . TIE PLATE NE(FLANGENMI ANGE BOLT SOO 3 0.SCO SGB�GROUNDING LUGS SS =MY SERIESCIffaZsl ROCK.T 3.0 MOUNT DETAIL —��— NOT TO SCALE 91.0 NOT TO SCALE U.L.LMT W MIRECOFASTE N:2TW 0 ROCK-IT 3.0 COUPLING ASSEMBLY NFOM 29 IX NOT TO SCALE Bzyn MAX MOUNT SPACING LANDSCAPE MOUNT SPACING=72' CLAMP,ATTACHMENT,TYP LANDSCAPE CANTILEVER=24' CLAMP'ATTACHMENT,TYP PORTRAIT MOUNT SPACING=48" COUP NO,TYP COUPLING,TYP PORTRAIT CANTILEVER=18" EVER:SEE MOULTING NOTES I I CIAMP�NG MOUNT SPACING:SEE ROGFIf SLOE I. 4G JNT NOTES CLAMP FRAMING,TYP MODIILE,TYP MODULE METALisommarlemommr rGPMMDDIAE,TW FLASHFLASHINGGP BONDED WASHER ..—FRAMNO,TYP FRAMING,TIP . ./L FORMS WATERTIGHT SEAL II L.IANDBCAPECIAAP SPACING will„ 4 PV SYSTEM MOUNTING DETAIL 5 MODULES IN PORTRAIT ANDSCAPE I I L=PORTRAIT S 1,0 NOT TO SCALE S 1,0 NOT TO SCALE CLAMP BRACHIA COMP SHINGLES r MIN AND HM MAX BETWEEN TOP OF ROOF MD BOTTOM OF MODULE ONENOLE STEEL STRAP CONDUIT BLS IAO S REEWW PY MODULE,TYP.MOUNT Aft TOROUE•1332 FT•LBS. TO FRAMING OF EXISTING ROOF TYPE,PARALLEL IIIEF 1 WITH PLANE OF ROOF - CONDUIT MOUNT BRACKET 1 vivint.Solar r . sunrun c,�1.,,r. 1800 ASHTON BLVD.LEHI,UT,84043 $ECT!ON VIEW / FLAWING OR TLE STRAP I29 L:17064 1 15 Zillini- MA LIC:t70B/81 168BBA a wNv.R3uFItdN42trU AOA RARAa:NYmMP.LYYt574016110hRNx,Md RRWIteu" ESTEVEZ RESIDENCE 28 MIRROR BROOK RD X 3 SECTION VIEW WEST YARMOUTH,MA 02673 F S 1.0 NOT TO SCALE 8 PV ARRAY TYP.ELEVATION 7 CONDUIT MOUNTING DETAIL UTILITY ACCOUNT:1428 862 0050 i g 1,0 NOT TO SCALE S 1.0 NOT TO SCALE METER:2201080 MOUNT DETAILS 383-0812879 s ROC:MAO S 1.0 DRAWN BY:DIN J SCALE:NOT TO SCALE DATE:06/102021 REVISION:0 oS00 ZS8 8Z14:0100:0 r AVM TZ/6T/s:Pauaq I £182499 £L9ZOVYY'47nOWieA A?t:::Ac7 Uf1JUflS- V899S1 18480LT FAO °C as)IOO I9 IOHJWW sZ IA 6Zt Ol LL8•T:039wfN a3TIVJSNI wt 1 aun-E W 2 a3uaPlsaa mom aaI .�uI . aV105J.NWA 11371VJSNI N z 1.1 z a a a.T. r - §c2t 2 2 .4 1` n zsa S>:O W W W W V O o-- a , a J 3 : a ''> > > 2 > 0 ',' 0 c t� A._ 8 a E w e -g v I Z mom" dr as 11. 1 # , 11 o t' . u a g z 1 z mO-a > ggg € tE 1 iiWgW g t - n n M M 1 0 } 1 4 w a J J 2 N 8 1. 411 CO 4-1 IAM E d o 33 s d V V V Et � N �y O E 2 2 N N w J S Wg7, II ,$ Vs" f Z O-E 3 4i 3 n Q 11111.1... p�pcc IS jl i■drO G yy� L C 1 Nfo N i= -H 3 Inverter/Optimizer specs PV Module Rating o STC Conductor Calculations optimizer SolarEdge P370 Module Make/Model JA Soler JAM60S17-32E/MR o m 1 DC input Power 370 Watts Max.Power Point Current(Imp) 9.57 Amps Wire ampacity calculated from 310.16&17 as appropriate with ambient temperature pI rc r DC Max.Input Voltage 60 Volts Max.Power-Point Voltage(Vmp) 33.97 Volts calculations from Table 310.15(8)(1)&310.15(B)(2)and raceway fill adjustments from 310.15(C) p o (1).Conduit on the roof shall be installed no less than 1"above the roof deck. 3? o A DC Max.Input Current 13.75 Amps Open-Circuit Voltage(Voc) 40.87 Volts N m 1 N PV Circuit conductor empathy is constrained using the 75'C column with the continuous duty DC Max.Output Current SS Amps Short-Circuit Current(Ix) 10.23 Amps uprating or the 90'C column with the relevant ambient temperature and raceway fill adjustments O t Max.string rating Inverter dependent.See SE documents. Max.Series Fuse(OCPD) 20 Amps without the continuous duty uprating per 690.8(B),whichever results with a larger wire size. 1 Inverter Wks/Model SolarEdge 5E3800H-US Nom.Max.Power at STC(Pmax) 325 Watts Non-PV Circuit conductors use the ampacity in the 75'C column or the 90'C column with the CEC Efficiency 99 % Max.System Voltage 1000V/1500V DC(UL) relevant ambient temperature and raceway fill adjustments,whichever Is less(110.14(C)& A r AC Operating Voltage 240 Volts Voc Temperature Coefficient -0.272 I %/C 310.14(A)(2)).The rating of the conductor after adjustments shall be greater than,or equal to, 3 Cont.Max Output Current 16 Amps the continuous duty uprated current. DC Max Input Current 10.5 Amps ASHRAE 2017-BARNSTABLE MUNICIPAL More information about conductor calculations can be provided upon request. Input Short Circuit Current 45 Amps Highest Monthly 2%D.B.Design Temp.:29.5'C Calc.Ex:Wire Ampacity x Ambient Temp.Corr,Factor x Conduit Fill Adj.Factor>=Output Current Max Output Fault Curcren 17.5 A/20 ms Lowest Min.Mean Extreme D.B.:-19.2'C (Tag 1 Under Array): entDC-to-DC Converter Output:10 AWG rated 30 A, 30 A>=18.75 A s_ ;_ Power Source(s)Output Calc:705.12(8)(3)(2) (Tag 2 On tRo-D): PDC-to-DC Converter Output:12 AWG rated 20 A, 20 A>=18.75 A O a (Tag 3 Exterior): Main Bus Rating;100Amps InverterOutpt:12 AWG rated20A, 20A>=20A • Main Service Breaker Rating:100 Amps C c PV Uprated Output Current:20 Amps •ism ,.- ,., 100A+20A<=100 x 1.2;120<=120A,OK ' C Z' • , or I ., r. I o+ e Other Notes f •Designed according to and all code citations are relevant to the 2020 National Electrical Code. •All Interior raceways carrying DC current shall be metallic. ,°4•, a m — Voltage and OCPD Calculations(690.7,690.9) Z a[ e: PV Source Max Circuit Voltage:Module Voc x(1-(AT x Voc Coeff))[art.690.7(A)] 2 I JAM60S17-325/MR:40.87 V x(1-((25 C—-19.2 C)x-0.272%))=45.78 V<=60 V z „ i Inverter Output Circult(s):Listed Output Current x 1.25[art.690.9(B)] SHEET Inverter 1:SE3800H-US Max Output=16 A x 1.25=20 A<=20 A(OCPD) NAME: System output current w/continuous duty=20 A on 20 A(System OCPD) I SHEET NUMBER: N W All AC Disconnecting Means•AC Disconnect(s), Conduit,Raceways,and t-Boxes(Labeled Every 10')and Installed within 3 ft of Rapid Shutdown Switch,Reflective,and shall be placed on Combiner Panels and Load Centers•er 690.54 inverter 1 DC Disconnect•er 690.53 both Panel Exterior&next to Main Disconnect•er•er 690.56 C 2 PHOTOVOLTAIC AC DISCONNECT o MAXIMUM DC VOLTAGE Reflective per690.31(D)(2) RAPID SHUTDOWN SWITCH MAXIMUM AC OPERATING CURRENT: SGA i " o i OF PV SYSTEM: af3o V PHOTOVOLTAIC POWER SOURCE FOR SOLAR PV SYSTEM NOMINAL AC OPERATING VOLTAGE: 240 V 8 PV S tern Disconnects• r 690.13(B) PV with Rapid Shutdown Switch,Installed within 3 ft of Service Disconnecting 1 1 1 PV SYSTEM DISCONNECT Means with min.3/8"black capitalized text on yellow background&3/16" A } A• black ca•italized text on white bac :round."r 690.56 C 0 TURN RAPID SHUTDOWN 0 SWITCH TO THE "OFF"POSITION TO AL_ ; SHUTDOWN PV SYSTEM AND REDUCE _ S SHOCK HAZARD •21. " C IN ARRAY Plaque/Directory at Service Equipment Location and Power Production System Disconnecting N e= c T. a C ai 'I CAUTION: MULTIPLE`SOURCES OF POWER All Disconnecting . Disconnects►,Load Centers,and Combiner POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE Panels•er690.13 B &690.15 C a FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS ELECTRICAL SHOCK HAZARD SHOWN TERMINALS ON THE LINE AND S LOAD SIDES MAY BE ENERGIZED 9 de IN THE OPEN POSITION W m —1 S r _-1` Power Source Output Connection,Adjacent to d m T- Back-fed Breaker• r 705.12 B 3 2 1 i AT.: 4 C ,___-_•_:. I METER AND MAIN POWER SOURCE OUTPUT CONNECTION SHEET +. SERVICE DO NOT RELOCATE NAME: ,..+ THIS OVERCURRENT PROTECTION DEVICE } l ; ' AC DISCONNECT Dual Power Sources in Main Service Panel ‘1 and Sub Panels er 705.12 C •SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER D C DISCONNECT LOCAL AHJ REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED 3 9 PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY SIGNS AND LABELS• SHEET DUAL POWER SOURCE SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING NUMBER: l. REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS SOURCES:UTILITY GRID OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR AND PV SOLAR ELECTRIC SYSTEM WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO fy) WITHSTAND THE ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS tit SITE PLACARD SHOWING ADDITIONAL POWER SOURCE WARNING MAXIMUM DC VOLTAGE �\ RAPID SHUTDOWN SWITCH DUAL POWER SOURCE //� •�• { a ' 7 AND DISCONNECT LOCATIONS.PLACARD SHALL BE g 0 1 OF PV SYSTEM V �� FOR SOLAR PV SYSTEM SOURCES:UTILITY GRID N MOUNTED ON EXTERIOR OF ELECTRICAL PANEL AND PV SOLAR ELECTRIC SYSTEM Y O 00 A8 u / WARNING MAIN BREAKER DE-RATED c c 1 / SOLAR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND DUE TO SOLAR CIRCUITS a e PHOTOVOLTAIC POWER SOURCE ® WITH RAPID SHUTDOWN LOAD SIDES MAY BE ENERGIZED 11 "'AMPS MAX ALLOWED i p J IN THE OPEN POSITION DO NOT UPGRADE Y a /� PHOTOVOLTAIC AC DISCONNECT WARNING 3 PV SYSTEM DISCONNECT O MAXIMUM AC OUTPUT CURRENT:•• A POWER SOURCE OUTPUT DONOT RELOCATENECTION NOMINAL AC OPERATING VOLTAGE:"'V THIS OVERCURRENT PROTECTION DEVICE Lv v = ROOFTOP ARRAY n: C CZ •— � P 0 ®IF APPLICABLE ' in I 1 4 INSIDE O PANEL e, 0 0 © 3 O8 OO 6 O8 6 cl'i •,3. EVERY 10'AND WITHIN 1'OF ELBOWS q4 m f Z DC O z des DISCONNECT MEl; 0 >'. INSIDE R i SHEET COMBINER PANEL VISIBLE/LOCKABLE A/C VIVINT SOLAR METER VISIBLE/LOCKABLE A/C SUB PANEL MAIN SERVICE NAME: ROOFTOP SOLAR INVERTER DISCONNECT(WHERE (WHERE REQUIRED) DISCONNECT JUNCTION BOX 2 (WHEN USED) (WHEN REQUIRED) DISCONNECT PANEL a21 REQUIRED) E •••-value calculated for each 3 9 I) TYPICAL SOLAR GENERATION INSTALLATION account,for specific value see the (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page SHEET NUMBER: •SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110,21(B)AS REQUIRED PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS•SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ft ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS W BONDING NOTES �=BONDING PATH MODULE FRAME ROCK-IT COUPLING MID CLAMP '� ,• 0 0 111511111111.111 4 - 0 , If^ , 1 ROCK-IT ROCK-IT SLIDE UL2703:2015 LISTED i PEDESTAL r 7 BONDING CLIP `� BONDS SOLAR MODULE "1 ..1_: FRAME TO OPTIMIZER ;' OR MICRO-INVERTER �•"` p � OPTIMIZER MOUNTED i 1! ' 'i l (I )ROCK-IT I T RAT F TO MODULE FRAME !1 !„ EG ED BONDING WITH UL2703 I li !I I! ONOT T SCAL I 33 OPTIMIZER BONDING DETAIL WITH UL2703 O SCALE PV MODULE TO ACT AS AN ACTIVE GROUNDING COMPONENT TO EGC re mid in aim mime • GROUNDING LUG(SEE S1.0 DETAIL#2) .-+ E-W BONDING PATH. 11 = .H - -11 - An IN-S BONDING PATH,SEE DETAIL#1. o ROCK-IT COUPLING vivint.Solar 11 ion- ili.1111-11- iliiNIIII-II Asunrunr(Pr•^ar,r 1800 ASHTON BLVD. TU LEHI, T,84043 El0 ROCK-IT COUPLING MA j�liE •11•! 11 ESTEVEZ RESIDENCE 28 MIRROR BROOK RD k WEST YARMOUTH,MA 02673 R UTLRY ACCOUNT:14288520050 4 METER 2291800 (j)NOTTOCALDLAYOUT WITH UL2703 BONDING DETAILS St 03 E5.0 ROC:MA-03 DRAWN BY.DIN j SCALE:NOT TO SCALE DATE:05n812021 REASON:0