Loading...
HomeMy WebLinkAboutBlde-21-006563 PLANS • JURISDICTIONALNOTES: --.____ _._-._ -- _--_---- _--- ----__—._ --.--__-- _.__-_.__ _--.__-_-GOVERNINGCODES I ALL WORBR SHALL CONFORM TO THE FOLLOWING CODES 1. 2015 INTERNATIONAL RESIDENTIAL CODE' 2. 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION I a. 2020 NATIONAL ELECTRICAL CODE 1 b. ANY OTHER LOCAL AMENDMENTS ` ____,,, ,e, ( S 5 ! SHEET INDEX: 1 PV 0.0-COVER SHEET PV 1.0-SITE PLAN S 1.0-MOUNT DETAILS : E 1.0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES E 3.0-WARNING LABELS I E 4.0-WARNING LABEL LOCATIONS ' 1 i I GENERAL ELECTRICAL NOTES: GENERAL STRUCTURAL NOTES: a. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING 1 MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF MOUNTED THE ROCK-IT SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BE I SYSTEMS,WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF SPACED AS SHOWN IN THE DETAILS,AND MUST BE STAGGERED TO 1 THE ROOF SURFACE. ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. b. ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE b. UNLESS NOTED OTHERWISE,MOUNTING ANCHORS SHALL BE 416.LAG 4Q. CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2 J4"PENETRATION INTO ROOF FRAMING. C. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE c, THE PROPOSED PV SYSTEM ADDS 3.0 paf TO THE ROOF FRAMING SYSTEM. d. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE d. ROOF LIVE LOAD=20 pat TYPICAL,0 paf UNDER NEW PV SYSTEM. -`" INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE e. GROUND SNOW LOAD•30 pat VOLTAGE. f. WIND SPEED=140 mph —_-------- ' a. SEE'E 1.0 AND"E 2.0 FOR DIAGRAMS,CALCULATIONS,SCHEDULE AND g. EXPOSURE CATEGORY=B a�} SPECIFICATIONS. ; V I n`.S O h r 1 1800 .T- • 7.04.L ",5 T,84043 1.877. I 92 South Sea Avenue PHOTOVOLTAIC SYSTEM SPECIFICATIONS; ,. M - ME-15888A SS-00 2 SYSTEM SIZE-14.950kW DC 19.800kW AC SUAREZ RESIDENCE 1 I MODULE TYPE&AMOUNT-(48)Jlnko Solar JKM325M-60HBL WITH 50 SolarEdge P340 OPTIMIZERS WEST YARMOUTH,MA,021373.5032 I MODULE DIMENSIONS-(UW/H)66.3"/39.45"/1.38" I TILITY ACCOUNT#:142347 .. INVERTER-(2)SolarEdge Technologies SE6000H-US AND SE3800H-US I'SERVICE#S8102tt3 1 INTERCONNECTION METHOD(GRID-TIED)-SUPPLY TAP ;REGAL 1 rPP5RATt+GcEr{T5R MA. _ COVER ;y - FonrE eA12020 ,DRawtr BY:DIN -11 SHEET J -- — PV STRING(S): — OF --., 1 1 SLOPE-32 SYSTEM LEGEND 1 ® 91)18 MODULES LTH•304 PV SYSTEM SIZE: MATERIAL•COMPOSITION NEW 14,950XW DC 9.800KW AC i ® 012)18 MODULES SHINGLE aqg02 SLOPE•32 EXISTING INTERIOR MAIN SERVICE PANEL POINT R3)9 MODULES q�IMUTH•304 ❑M OF INTERCONNECTION TIED TO DETACHED UTILITY METER 42309284. ® #4)9 MODULES MATERIAL•COMPOSITION SHINGLE El NEW SMART METER.LOCATED WTTHN IG OF Mr. 'ZSLOPE•32 MOTH-124 ® NEW PV SYSTEM AC DISCONNECT.LOCATED � Ili j •:.• _ MATERIAL-COMPOSITION WRHN t0 OFMBP. �� SHINGLE El NEW DEDICATED PV SYSTEM COMBINER PANEL. " 21 NEW PV SYSTEM INVERTERS:SolnEApe Trnologlee A.j 9EB000IWS 8 9ESB3O1AU8(R8D EIXIIPPED) A/ � 48 NEW SOLAR OE SOtAR 0 OPTIMIZERS, MODULES. EW SOLAR EDGE P310 OPTIMIZERS,MOUNTED THE BACK OF EACH MOOULE. /AVA �� l NEW ARICTION BOX.(MOUNTED WITH souped() Q O 0 O 1 n ,.....x.:.:.:.::..........x.x. I O EXISTING DETACHED UTILITY METER:li l l N 230B2B/ 1 ,_ iro.„(<„:„.\\co 1cf) 6 C ::::„.„,..............!...:.: : . \\.\\ s.‘ `M WQ kklio ® \ \ i vivint.Solar 1.877.404.4129 32 Ir ILITYACCZOU RESIDENCE2347MA, 30�027._.__., SITE PLAN 1 R, N 2n3 OPERATNO_CEN E MA70..3 DATE 8RI2020 L__- SCALE 1/8 1'-0" J DRAWN BY:DIN ! MOUNTING LEGEND i i I I ROCK4T COUPLING MID CLAMP ROCKIT COUPLING Alk MID CLAMP A ■ ar i1111 1 PEDESTALIle " ^ ROCK•R SLIDEFLASHING ® MID CLAMP COUPLING SHELF ,,..1i, /0,lir \ I ! ROCKdT -.' HEX FLANGE BOLT MI 'sI SOD SERIES ES T, • K•R COUPLING SHELF \ _ `{ IS0MEMRICVIEW 1i Ir�' COMP SHINGLES . • 1 �� BB LAG SCREW �� TOROU S LAG FT.LSCREW slum 1 lir \ 71E PLATE HEX wino UNOE BOLT 300 SERIES SS OCK-IT 3.0 MOUNT DETAIL B LSCO SGB-4 GROUNDING LUGS = C. � 0 51.0 MOT NOT TO SCNe TO rALe U1.LWINO FORECOFMTEN:21W 2 -OCK-IT 3.0 COUPLING ASSEMBLY MONT,24 O. s10 NOT TO 9.1 IQP NEw CLAMP•ATTACHMENT CLAMP•ATTACHMENT COUPLING 1 COUPLING " .•.ul A 1 a: -: mis ..aq CAPE.MAX 7r(S-0") PORTRAT.MAX 4"(4'-0") -• K•R SLIDEICEN CLAMP 111111111! RAFTER MODULEII IIII MODULE iI fL METAL EPDM BONDED WASHER ' )TTT� (T=T( I"tl I„'I MULE ,I —/I FORMS WATER1NiHT SEAL 1 1 1 1 1 ► 1 RAFTER IIIIIIii DER RAFTER' 218"AT 24^O.C. 1 - SYSTEM MOUNTING DETAIL ®MODULES IN PORTRAIT/LANDSCAPE -•- RAT COMP SHINGLES ` 01.0 rarrorAM MOT TO 1GM r.-. r..aT% 21/2 MIN S•MIN ANDS"MAX BETWEEN TOP OF ROOF AND BOTTOM OF MOOULE :. MIN S/18'D41M ONE HOLE STEEL STRAP it �SS LAG SCREW .� PV MODULE,TYP.MOUNT •NDUR `, `,TOROUE•13f2 F•M1LBS. `� TO FRAMING OF E.EXMTINO I \I Y I i n t.S o I a r \i WITH PLANE OF ROOF PARALLEL ® J CONDOR MOUNT BRACKET ir MAXIM s' I 1 877.404.4129 SECTION VIEW / I FLASHING OR TILE STRAP —__.-----_. - SUAREZ RESIDENCE .V'/l' :/•I,fV".Y .\\V'+.•L'•YAf[WYt'f.' IN'..\\V'ML:•:I.itTv+Y t'ti..\• - C[J OCTATC 3 SECTION VIEW — ! UTILITY ACCOUNT M.A4234730027 s 1.0 NOT TO SG. . PV ARRAY TYP.ELEVATION CONDUIT MOUNTING DETAIL NOTro Wu1 NOT roewl _.._r.-. -\ SERVICE B:B•8102773 1 {{� MOUNT DETAILS AEAATMO2020 :MA03 ! S 1.0 _— SCALE:NOT TO SCALE_._. - ____.- ---- .__-_-.--- --.__---...--- DRAWN BY:DIN LZooELVEzvt'-wno v461f1 tz/zWv=aawan I £LLZ0v9 EL9Z0vw'N111nOWWWAJS3M ,`,,.!.-,';V;.)uniunS 1/999St I SPSOLt 2UVAMICI °C j'3 3AVV3SSZ6 ADP 6ZtVVOYLLSt:a39WfNa3tA11SNl W 2 aufl-g W f aauaplsaaens tlV1OSINIAJA: 3TVJSNl viz . z i zai i< co 111 eo Ca m o�5. %m ono? 1!1 S. r.e O H p Q Q O p4-gg � � ��m 2 8 S S a s JLJ L w sum > z z z z O� N Wa o m .n .w .n tag€.g E� 0 6 E 3 3 3 3 3 31.91i1919 ¢�__ }� x 3 o i < < < o < < i o < i fng° •i Ll A EYor c 3 > i $',o"do • e€ ~ v N W = € a r n _ 2c.z� 3 n n c L ?", fy; 5 5 z z i 1 g8n23 o 3 o O x _ _ oo•�n - fi Y - _ s _ n}_ s t W u P u 0 3 0 3 0 3 l 3 o g b t, c t• c I t r Y t. f o W o . W I ., I W 5t. ~ 5 f .. .. .. .n n o e .n .n .e . E r ii u w 0 0 E ; 'f l tJgEv 03 ' g V 0 M w W E E O Q QfL N y L W 7 N "1 h V.« a a X V 2� 42 s_ W6ry 3 m og $off Rs W" V i .,"'-10 .s � _ I I /a 1r` .a* ro g `Ij� z J G < � lIoOs 8 L a 0 of .;fog gg e3e i�a Zoe IN 3 r, 3 F.fo 3 Inverter/Optimiser Specs PV Module Rating 0 STC Conductor Calculations ,„ „ Optimizer Solara P370 Module Make/Model linko SolarJKM325M-60HB1 N DC Input Power 370 Watts Max.Power-Point Current(Imp) 9,68 Amps Wire ampacity calculated from 310.16&17 as appropriate with ambient temperature of DC Max.Input Voltage 60 Volts Max.Power-Point Voltage(Vmp) 33.6 Volts calculations from Table 310.15(B)(1)&310.15(B)(2)and raceway fill adjustments from 310.15(C) . 1 DC Max.Input Currentoge 13.75 AmpsOpen-Circuit (1).Conduit on the roof shall be Installed no less than 1"above the roof deck. . .4 • iJ DVoltage(Voc) 41.1 Volts PV Circuit conductor anpaclty is constrained using the 75'C column with the continuous duty s t DC Max.Output Current 15 Amps Short-Circuit Current(Isc) 10.2 Amps uprating or the 90'C column with the relevant ambient temperature and raceway fill adjustments ur Max.string rating Inverter dependent.See SE documents. Max.Series Fuse(OCPD) 20 Amps without the continuous duty uprating per 690.8(B),whichever results with a larger wire size. a RI 1 Inverter Make/Model Solarldge 386000H-US - Nom.Max.Power at STC(Pmax) 325 Watts Non-PV Circuit conductors use the ampacity in the 75'C column or the 90'C column with the 3i a �, CEC Efficiency 99 % Max.System Voltage 1000 VDC(UL/IEC) relevant ambient temperature and raceway fill adjustments,whichever is less(110.14(C)& AC Operating Voltage 240 Volts Voc Temperature Coefficient -0.28 I %/C 310.14(A)(2)).The rating of the conductor after adjustments shall be greater than,or equal to, i 8 Cont.Max Output Current 25 Amps the continuous duty uprated current DC Max Input Current 16.5 Amps ASHRAE 2017-BARNSTABLE MUNICIPAL More Information about conductor calculations can be provided upon request. Input Short Circuit Current 45 Amps Highest Monthly 2%D.B.Design Temp.:29.5'C _ Calc.Ex:Wire Ampacity x Ambient Temp.Corr.Factor x Conduit Fill Adj.Factor>-Output Current Max Output Fault Current 27.5 A/20 ms Lowest Mln.Mean Extreme D.B.:-19.2'C (Tag 1 Under Array): Inverter 2 Make/Model SolarEdge S!S8001-US DC-to-DC Converter Output:10 AWG rated 30 A, 30 A>=18.75 A >.,. CEC Efficiency 99 % (Tag 2 On Roof): C5 Power Source(s)Output Cak:705.11 DC-to-DC Converter Output:12 AWG rated 20 A, 20 A>.18.75 A Q AC Operating Voltage 240 Volts (Tag 3 Exterior): Cont.Max Output Current 16 Amps Service Rating:200 Amps Inverter Output:8 AWG rated 50 A, 50 A>=31.25 A DC Max Input Current 10.5 Amps PV Breaker Rating:60 Amps (Tag 4 Exterior): C C Input Short Circuit Current 45 Amps 60A<=200A,OK Inverter Output:12 AWG rated 20 A, 20 A>=20 A e ` .-1 Max.Output Fault Current 17.5 A/20 ms (Tag 5 Exterior): > C Inverter Output:6 AWG rated 65 A, 65 A>-51.25 A ==:. (Tag 6 Exterior): , Service Feeder.6 AWG rated 65 A, 65 A>-60 A $ Other Notes•Designed according to and all code citations are relevant to the 2020 National Electrical Code. •All Interior raceways carrying DC current shall be metallic. cc c 1 Voltage and OCPD Calculations(690.7,690.9) Z PV Source Max Circuit Voltage:Module Voc a(1-(AT a Voc Coeff))(art.690.7(A)] JKM325M-60HBL:41.1 V x(1-((25 C--19.2 C)x-0.28%))=46.19 V<=60 V Ur z z Inverter Output Circult(s):Listed Output Current a 1.25(art 690.9(5)] SHEET Inverter 1:SE6000H-US Max Output=25 A a 1.25=31.25 A<=35 A(OCPD) NAME: inverter 2:SE3800H-US Max Output=16 A a 1.25=20 A<=20 A(OCPD) System output current w/continuous duty=51.25 A<=60 A(System OCPD) let SHEET NUMBER: N IA All AC Disconnecting Means-AC Disconnect(s), Inverter 1 DC Disconnect per 690.53 Conduit,Raceways,and 1-Boxes(Labeled Every 10')and Q Installed within 3 ft of Rapid Shutdown Switch,Reflective,and shall be placed on Combiner Panels and Load Centers•-r 690.54 n n Reflective per690.31(D)(2) both Panel Exterior&next to Main Disconnect per per 690.56(C)(2) PHOTOVOLTAIC AC DISCONNECT c rN MAXIMUM DC VOLTAGE RAPID SHUTDOWN SWITCH MAXIMUM AC OPERATING CURRENT: 41 A g > § R OF PV SYSTEM: aeo V PHOTOVOLTAIC POWER SOURCE FOR SOLAR PV SYSTEM NOMINAL AC OPERATING VOLTAGE: 240 V 1 < g �N4 Inverter 2 DC Disconnect per 690.53 PV System Disconnects per 690.13(B) PV with Rapid Shutdown Switch,installed within 3 ft of Service Disconnecting a MAXIMUM DC VOLTAGE PV SYSTEM DISCONNECT Means with min.3/8"black capitalized text on yellow background&3/16" black a•talized text on white bac round•er690.56C OF PV SYSTEM: 480v r ` s_ a AL.TURN RAPIDSHUTDOWN ' p f SWITCH TO THE "OFF"POSITION TO A--__, } SHUTDOWN PV SYSTEM AND REDUCE • "• SHOCK HAZARD . IN ARRAY • N Plaque/Directo at Service Disconnecting Means per 690.56 B,&705.10 ' <, a CAUTION: MULTIPLE SOURCES OF POWER All Disconnecting Means-AC&DC 1 Disconnect(s),Load Centers,and Combiner POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE. Panels per 690.13(B)&690.15(C) FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS ELECTRICAL SHOCK HAZARD f SHOWNTERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED 9 od IN THE OPEN POSITION 1 -M Power Source Output Connection,Adjacent to Back-fed Breaker•er 705.12 B,3 2 II: E -�- t _ AT : L_ __.... ...-1 F Kit RAND MAIN POWER SOURCE OUTPUT CONNECTION SHEET ..— - DO NOT RELOCATE NAME: ---" SER VICE Y ICE, THIS DO PROTECTION DEVICE _ / \,.AC DISCONNECT Dual Power Sources In Main Service Panel [Al . J DC DISCONNECT and Sub Panels 'Cr 705.12 • ICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER SIGNS/LABELS oICAL AHJ REQUIREMENTS•S GNS/LABELS SHALL REQUIREMENTS MEET OF 7THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED J PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI Z535.4.2011,PRODUCT SAFETY SIGNS AND LABELS• SHEET tSIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING NUMBER: DUAL POWER SOURCE SOURCES:UTILITY GRID REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR AND PV SOLAR ELECTRIC SYSTEM WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO m WITHSTAND THE ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS W C. SITE PLACARD SHOWING ADDITIONAL POWER SOURCE WARNING . MAXIMUM DC VOLTAGE RAPID SHUTDOWN SWITCH DUAL POWER SOURCE m N OF PV SYSTEM •"V 4 FOR SOLAR PV SYSTEM 7 , AND DISCONNECT LOCATIONS.PLACARD SHALL BE 10 0 MOUNTED ON EXTERIOR OF ELECTRICAL PANEL SOURCES:UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM i u, § gg C WARNING MAIN BREAKER DE-RATED N , .a 2 PHOTOVOLTAIC POWER SOURCE ( Q ' SOLAR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND DUE TO SOLAR CIRCUITS vv+ ✓J WITH RAPID SHUTDOWN C LOAD SIDES MAY BE ENERGIZED 11 ***AMPS MAX ALLOWED ^ oNi IN THE OPEN POSITION DO NOT UPGRADE PHOTOVOLTAIC AC DISCONNECT /� WARNING PV SYSTEM DISCONNECT �� • ® POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE 3 ( (� , MAXIMUM AC OUTPUT CURRENT: A `7J \_/ NOMINAL AC OPERATING VOLTAGE:'••V THIS OVERCURRENT PROTECTION DEVICE ROOFTOP ARRAY d `+ © } /` c C •> Q• O ®IF APPLICABLE ' 1 O © INSIDE O O D p C p C C De PANEL ivEVERY 1© 8686 • • °CO ® ® ® ® 0 O O i1 WITHIN 1'OF ELBOWS IN - DC 0 z — DISCONNECT O - INSIDE O i z E _ _--� ---. ---- SHEET ROOFTOP s COMBINER PANEL VISIBLE/LOCKABLE A/C VIVINT SOLAR METER VISIBLE/LOCKABLE A/C SUB PANEL MAIN SERVICE NAME: JUNCTION BOX 2 SOLAR INVERTER (WHEN USED) DISCONNECT(WHERE (WHERE REQUIRED) DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL REQUIRED) •'•-value calculated for each E3 1 ep TYPICAL SOLAR GENERATION INSTALLATION account,for speclflc value see the SHEET (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page NUMBER: •SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI Z535.4.2011,PRODUCT SAFETY SIGNS AND LABELS•SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE er ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS I I